Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹34.3 L+₹1.7 L (5.26%)Rejected-Finance NOT AVAILABLE | NEW DELHI | DELHI | 110001 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹35.5 L+₹2.9 L (8.86%)Rejected-Finance NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹36.8 L+₹4.2 L (12.9%)Rejected-Finance DINJAN P O DINJAN DIST DIBRUGARH ASSAM 786 183 E 4 CWE DINJAN | DIBRUGARH | ASSAM | 786183 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹37.7 L+₹5.1 L (15.8%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
22 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMANDER WORKS ENGINEER, DINJAN
COMMANDER WORKS ENGINEER, DINJAN
PROVN OF SECURITY LIGHT AND ALIED INFRA AT GANESHBARI
2022_MES_554277_1
84132E8
Open Tender
Civil Works
Item Rate
150 days
GE DINJAN
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE DINJAN
₹86,000
Yes
18 Nov 2022
26 Sept 2022
29 Oct 2022
26 Sept 2022
22 Oct 2022
17 Oct 2022
26 Sept 2022 - 7 Oct 2022
60 days
Amount
S and F Hot dip galvanized internally and externally throughout octagonal poles as per IS-2629/ESEN 250 1461 having 9 metre lengh, sheet thickness 3mm top dia 70mm bottom dia 155 mm base plate dimension 260x 260x 16mm bolt size 4 x M24 and length of foundation bolt 750mm complete all as specified and as directed (Make Crompton Cat No-HM 1109P or equivalent make as given in Appx B)
S & F LED street lights nominal power 100 Watt LED, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyster powder coated, life span of minimum 50000 working hours as per catalogue No. ENDURAPEARLMAGNUMSL100WLED757PASYTOTGAST of Havells or equivalent of Make including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S & F in repairs Integral compact wide beam high performance LED flood light luminiatre with IP 66 protection, tampered protective toughened glass cover, thermal shock impact resistance cover, epoxy black powder coated finish, high purity , 200W LED of luminous efficiancy greater than >120 Lm/watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 10%, CW available CCT of 6500K, power factor of minimum 0.95, integral high pressure die-cast aluminium housing with sealed toughened glass cover, life span of minimum 50000 working hours with built in control gear including connecting up with 2.5 Sqmm multistranded Aluminium conductor cables of suitable length with fixed to pole/wall, etc and testing complete all as specified and directed.(Make Havell cat No JETA VALOURFL200WLED757PINTNBLT or eqv make as given in Appx B) Note : Fixing arrangements such as clamp, nut & bolt shall be included in unit rate.
S & F in repairs Integral compact wide beam high performance LED flood light luminiatre with IP 66 protection, tampered protective toughened glass cover, thermal shock impact resistance cover, epoxy black powder coated finish, high purity , 100W LED of luminous efficiancy greater than >120 Lm/watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 10%, CW available CCT of 6500K, power factor of minimum 0.95, integral high pressure die-cast aluminium housing with sealed toughened glass cover, life span of minimum 50000 working hours with built in control gear including connecting up with 2.5 Sqmm multistranded Aluminium conductor cables of suitable length with fixed to pole/wall, etc and testing complete all as specified and directed.(Make Havell cat No JETA VALOURFL100WLED757PINTNBLT or eqv make as given in Appx B) Note : Fixing arrangements such as clamp, nut & bolt shall be included in unit rate.
S&F Street light bracket single arm of length not less than 1.2 m suitably fixed to octagonal pole as per site requirement and OEM recommendations including nut bolt and clamping arrangement complete all as specified and directed
Supplying & laying in trenches 32 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Supply & spreading in trenches sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete M10 (Nominal Mix) using 20 mm nominal size coarse aggregate in pole coping or roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
S&F in repairs modular junction box made of SMC/FRP of size 250x250x155mm with provision of MCB SPN 6A, and connector terminal bus bar 4 pole indicating RYB Phase Colour and Neutral colour complete fixed to street light pole with suitable size of mild steel/ flat iron clamps, nuts and bolts complete all as specified and as directed. Make : Cat No. GSJB525 of Sintex equivale as given in Appx B
S & F medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983, nominal size 25 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed.
S & F in repair Post top light fitting any type/capacity and supply and fix LED Post Top LED light fitting 45/50 watt, includinng proving connection with 1.5 Sqmm copper conductor, multi stranded copper conductor cable of required length Make- Havells Model-RUBYMAXIPT50WLED757PSYMTOPC or equivalent make given in Appx B
Supply and fix time switch digital type 415 volt three phase of 20 amps rating with contactor fitted inside steel enclosure complete including connecting items complete all as specified and directed.Make-Havells/Philips or equivalent make given in APPX B
Supply and fix time switch digital type 250 volt three phase of 20 amps rating with contactor fitted inside steel enclosure complete including connecting items complete all as specified and directed.Make-Havells/Philips or equivalent make given in APPX B
S&F in repairs, PVC insulated and sheathed, multi standard aluminium conductor cable 2.5 Sqmm Weather proof flat twin core cable to connect from junction to light etc complete all as specified and as directed
M/S KESHAVECONSTRUCTIONS
M/S SINGH TRADERS
JANATA CONSTRUCTION
satyabhama and co
M/s HALDER ENTERPRISE
TOTCO
Garg Brothers
R D Enterprises
R.D.CONSTRUCTION
M/S Praduman Kumar Sharma
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .