| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC | ₹2.7 Cr | L1 | Accepted-AOC As L1 Bidder the contract is awarded |
| 2 | Rejected-Technical 4458 B WAKAL WADI KARANJA ROAD KAIJ TAL BEED | KAIJ | BEED | MAHARASHTRA | - | - | Rejected-Technical Fitness Certificate for Machinery by ACE (Mech) Not Attached |
| 3 | Rejected-Technical 1551 SUBHASH NAGAR BARSHI TAL BARSHI DIST SOLAPUR | BARSHI | SOLAPUR | MAHARASHTRA | - | - | Rejected-Technical Similar nature work is less than required |
| 4 | Rejected-Technical MU PO LONHIVAR TA BHOOM JI DHARASHIV | DHARASHIV | MAHARASHTRA | - | - | Rejected-Technical Insufficient Machinery |
| Sl No | Description | Qty | Unit | Sunil Kailas Patil L1 |
|---|---|---|---|---|
| 1.00 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. SR.NO 11.1 P.NO 46 | 1,474.39 | Cubic Meter | 703.71 ₹10.4 L |
| 2.00 | Dewatering including diversion of stream,providing cofferdams,bunds,etc.as may be necessary for foundation and other parts of the work and balling out water during and after excavation s required.SR.NO 11.1 A P.NO 46
I) For Abutment | 466.65 | Cubic Meter | 153.97 ₹71,850.10 |
| 3.00 | II)For returns | 14.1 | Cubic Meter | 71.26 ₹1,004.77 |
| 4.00 | Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 SR.NO 11.2 P.NO 46
I.Sand Filling | 218.94 | Cubic Meter | 3,095.05 ₹6.8 L |
| 5.00 | II .Rubble Filling For BC soil | 152.82 | Cubic Meter | 1,140.19 ₹1.7 L |
| 6.00 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 SR.NO 11.4 P.NO 47
(PCC GRADE M-15) | 120.94 | Cubic Meter | 6,719.7 ₹8.1 L |
| 7.00 | Providing and laying in situ/ ready mix concrete controlled reinforcedcement concrete of trap metal for raft slab including "V" haunches, formwork, scaffolding, compaction by vibrating, finishing curing etc. complete. concrete batch mix plant/ pan mixer with fine agreegates of required specifications etc. complete. (excluding reinforcement). a)RCC Grade with reversible drum type mixer/ concrete batch mix plant (pan mixer)
Specifications: MoRT&H (5 th Rev ) 1700,2304
SR.NO 16.6 P.NO 61 FOR RAFT SLAB
( RCC GRADE M-30) | 158.13 | Cubic Meter | 6,641.27 ₹10.5 L |
| 8.00 | Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301 SR.NO 14.1 P.NO 56 | 216 | Cubic Meter | 2,390.85 ₹5.2 L |
| 9.00 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204,For height upto 5 m SR.NO 13.1 III P.NO 49 (RCC GRADE M-30) | 811.02 | Cubic Meter | 9,072.39 ₹73.6 L |
| 10.00 | Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202SR.NO 12.7 P.NO 49 | 44.92 | MT | 83,523.07 ₹37.5 L |
Tender Value
₹2.6 Cr
EMD Value
₹2.7 L
Closing Date
18 Nov 2025, 5:30 pmClosed
Superintending Engineer PMGSY Chh. Sambhajinagar
Plot No.3, Block No.107, Galaxy Corner, First Floor, Satara Area, Near Renuka Mata Mandir, Beed Bye Pass Road, Chhatrapati Sambhajinagar 431010
Construction of bridge on road District Border to Sirsav Bhandgaon at Ch.2/150 Tq- Paranda Dist- Dharashiv
2025_MRRDA_1243627_1
ADB-(II)-OSM-BR-05
Open Tender
Civil Works - Bridges
548 days
PARANDA
Please refer Tender Documents
2 documents required · 2 mandatory
₹11,800
₹2.7 L
16 Apr 2026
11 Nov 2025
20 Nov 2025
11 Nov 2025
18 Nov 2025
11 Nov 2025
11 Nov 2025 - 14 Nov 2025
Amount
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. SR.NO 11.1 P.NO 46
Dewatering including diversion of stream,providing cofferdams,bunds,etc.as may be necessary for foundation and other parts of the work and balling out water during and after excavation s required.SR.NO 11.1 A P.NO 46 I) For Abutment
II)For returns
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 SR.NO 11.2 P.NO 46 I.Sand Filling
II .Rubble Filling For BC soil
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 SR.NO 11.4 P.NO 47 (PCC GRADE M-15)
Providing and laying in situ/ ready mix concrete controlled reinforcedcement concrete of trap metal for raft slab including "V" haunches, formwork, scaffolding, compaction by vibrating, finishing curing etc. complete. concrete batch mix plant/ pan mixer with fine agreegates of required specifications etc. complete. (excluding reinforcement). a)RCC Grade with reversible drum type mixer/ concrete batch mix plant (pan mixer) Specifications: MoRT&H (5 th Rev ) 1700,2304 SR.NO 16.6 P.NO 61 FOR RAFT SLAB ( RCC GRADE M-30)
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301 SR.NO 14.1 P.NO 56
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204,For height upto 5 m SR.NO 13.1 III P.NO 49 (RCC GRADE M-30)
Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202SR.NO 12.7 P.NO 49
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 SR.NO 12.11 P.NO 48
Providing and laying 0.90 meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete. SR.NO 16.7
II) Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 SR.NO 12.9 P.NO 50
Providing pressure relief pipes 100 mm dia in bottom slab of box cell on a filter media base of 500 mm x 500 mm as per drawing and technical specification Clause 1205.5.7 SR.NO 12.14 P.NO 50
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 SR.NO 13.1 P.NO 52 (RCC GRADE M-30)
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 SR.NO 13.1 P.NO 52 (RCC GRADE M-30)
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 SR.NO 13.3 P.NO 52
Providing and laying cement concrete wearing course M 30 grade excluding reinforcement @ 38kg/Cumcomplete as per drawing and technical specifications Clauses 800 and 1206.3 SR.NO 13.5 P.NO 52
III) Expansion joint with 25 mm thick bituminous pad ( Compressible Rubber Pad 2018-19) SR.NO 13.16 P.NO 54 II A
Providing and fixing in position pipe railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x50) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 SR.NO 13.8 P.NO 53
Providing and fixing Granite/Marble tablet of 15 mm to 18 mm thickness ,including making groove in wall / concrate surface filling joints with slurry,curing,polishing,rounding edges,as required cleaning etc complete of size and description as per detailed drawings including embosseing and fitting in 1:2 cm border SR.NO 12.15 P.NO 50
Boundary Pillar,Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704 SR.NO 10.11 P.NO 41
Clearing and Grubbing Road Land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201SR.NO.2.2 P.NO.8 (A) In area of non-thorny jungle
(B) In area of Thornly jungle
(iii) Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3 SR.NO.3.5 P.NO 14 (III)
Construction of Embankment with Material Obtained from Roadway Cutting,Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 SR.NO.3.3 P.NO 13
Construction of Embankment with Material Obtained from Borrow Pits,Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 SR.NO.3.4 P.NO 13
Construction of Subgrade and Earthen Shoulders,Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.SR.NO.3.14 P.NO 16
(A) By Mix in Place Method,Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401.SR.NO.4.1 P.NO 19
2)WBM Grading 2,Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening binding meterials to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405.SR.NO.4.8 2 P.NO 22
Providing and fixing a typical MMGSY Citizen information board as per specification provided on detailed drawing of NRRDA having frame size of 2500x1150mmwith75mm square or round steel tube for support fixed in a concrete block of 60x60x75cm size.Information as provided in drawing of NRRDA shall be displayed on a CR/GI sheet of appropriate thickness and fixed at steel frame with 5mm steelplate.All lettering and painting arrows border etc.will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloured as mentioned in detailed drawing. All sections of framed posts and steel tube shall be painted with primer and two coat of epoxy paint as per drawings.(Rate as per RD&WC Deptt.No.CMGSY-2007/CR/145/Yojana-9 dt. 4.4.2007) SR.NO 10.16 P.NO 42
Providing and Fixing 'Logo' of MMGSY Project,Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 SR.NO 10.16 P.NO 42
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 SR.NO 14.5 P.NO 56
Providing and Laying Reinforced Cement Concrete Pipe NP2 for culverts on first class bedding of granular material in Single Row , including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. SR.NO 9.4 P.NO 34
Semi Reflective Traffic Signs: Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.SR.NO.10.2 (B) P.NO.39 i) 600 x 450 mm rectangular
ii) 900 x 600 mm rectangular
Painting Two Coats on New Concrete Surfaces Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701 SR.NO 10.50 P. NO.40
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Objectmarkers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the roundand confirming to I.R.C. 79 and the drawingsMORTH 806 Number 1047 21 PWD SSR 2022-23 I.NO 6.15 P.NO 50
MMGSY / PMGSY Maintenance Information Board- Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor. I.NO 10.23 P.NO 41
stage.html
html • 0.05 MB
technical_2145121.pdf
techsummary_2145121.pdf
finance_2145121.pdf
BOQ Comparative Chart
xlsx
finsummary_2145121.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
OtherDocsADBBR05.pdf
Other Document • 2.50 MB
BOQ_2145121.xls
BOQ • 0.35 MB
SBD_ADB_II_OSM_BR_05.pdf
Tender Documents • 2.27 MB
Download all tender documents and submit your bid