Executive Engineer(E), BSNL ED, Cuttack
15 Cantonment Road, SSPO Building, 2nd Floor, Cuttack-753001
Repairing and maintenance of BSNL transformer substation
2023_BSNL_151433_1
NIT No- 02/BSNL/ED/CTC/2023-24
Open Tender
Electrical Works
Item Rate
365 days
CUTTACK SSA OF BSNL
3 documents required · 3 mandatory
₹0
₹11,581
Yes
27 Apr 2023
11 Apr 2023
24 Apr 2023
11 Apr 2023
21 Apr 2023
11 Apr 2023
11 Apr 2023 - 18 Apr 2023
Amount
Attending to break down calls, physical inspection of Substation accessories, overhead lines, feeder panels, meter box etc. to find out the faults and taking corrective measures for restoration of power supply i/c minor repairing works i/c replacement of insulators, LAs, jumpers, lugs/sockets etc. in coordination with supply authority etc. as required.
Liaison with different units of the supply authority i.e. Field units, MRT units, Division office etc. for obtaining shut down of 11KV line, breaking of meter seal if required to carry out the major repairing and maintenance works of the Transformer substation/replacement/rewinding and re-installation of the repaired Transformer, re-energisation, testing and re-commissioning etc. as required.
Thorough servicing of AB Switch, adjustment of bearings, male/female contacts, lubricating of moving items i/c replacement of minor defective parts like nuts, bolts, clamps, wire braided copper strips and checking the functional operation, etc. as required.
Replacement of the following defective spare parts of the transformer substation by new one i/c fitting, connection etc. as reqd.
Male contact and Female contacts made of hard drawn copper for 200 Amps air break switch with wire braided strip etc. comprising of 3nos per set.
Rotor mechanism for 200 Amps air break switch.
Square/round bar for AB switch (Horizontal unit)
11KV Post Insulator for 200Amps AB switch/ HG fuse unit
Operating Handle made of 25/32mm Medium class GI pipe with wire braided copper strip
Heavy duty operating pipe for air break switch i/c fabrication etc. as required.
Replacement of damaged breather for 25 KVA 11KV/0.415KV transformer by a new one with dry silica gel etc. as required.
Replacement of faulty/damaged pin insulators by new one of 11 KV grade pin type insulator with large steel head G.I. pin, nuts, washers on existing HT pole/ DP structure etc. complete as required.
Replacement of faulty/damaged disc insulators by new one of 11 KV, 45 KN porcelain disc insulator with galvanized insulator fittings, ball and socket type and complete with galvanized strain clamps, bolts, nuts, washers etc. as required.
Replacement of faulty Lightening arrestors by new ones of nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanized clamping arrangement, G.I. bolts, nuts, washers etc. as required, comprising of 3nos per set.
Replacement of damaged and unserviceable AB switch by new one of 11 KV, off load, single break, triple pole, horizontal type, gang operated air break switch having 2 nos. 11 KV post type insulator per phase complete with galvanized channel iron base, arcing horns, 25 mm dia. 6mtr. long GI pipe, tinned copper wire braided flexible earthing wire & operating handle with locking arrangement etc. complete as required.
Replacement of damaged and unserviceable DO/HG fuse units by new one of 3 phase, 11 KV outdoor type Horn Gap Fuse unit having 2 nos. 11 KV post type insulator per phase complete with channel, cu-wire etc. as required. (one set comprising 3 units).
Supply & drawing of 55 sqmm. AAA conductor for overhead line and DP structures i/c binding with insulators etc. complete as required.
Rewiring of the DP structure of Transformer Sub Station with 55sqmm AAA /50sqmm insulated Al.conductor stranded cable with al. Lugs/sockets, binding with post insulators etc. complete as required.
Replacement of the defective parts/components by new ones of following sizes & ratings aluminium/copper sockets/lugs for PVC sheathed / XLPE aluminium/copper conductor cable of 1.1 KV grade i/c fixing/crimping etc. as required.
16/25 sqmm Al socket.
35 sqmm Al socket.
55 sqmm Al socket.
Dismantling the following ratings faulty transformer from the existing D.P. structure/Plinth & installation of standby/repaired transformer i/c testing and commissioning, recording the required parameters etc. by qualified staff, arranging required tools & plant with proper precautionary measures etc. as required.
25 KVA, 11KV/0.415KV, 50 Hz Aluminium wound oil cooled Transformer
63 KVA, 11KV/0.415KV, 50 Hz Aluminium wound oil cooled Transformer
Repairing of 25/63 KVA Aluminium/copper wounded transformer at factory/workshop by dismantling the faulty transformer, re-insulating the windings, heating, reassembling i/c replacement of gaskets, nuts & bolts, washers, carry out factory tests etc. complete as required. (Rewinding of Transformer is not in the scope of this item)
Repairing of 25 /63 KVA Aluminium/ copper wounded transformer at site i/c opening top cover, checking the bush, inter connections wires/strips from bushings to transformer windings, tightening the connections, etc. as required. (Rewinding of Transformer is not in the scope of this item)
Rewinding of the HT windings of the following ratings Oil immersed Distribution class Transformer with superior grade and suitable size Double paper covered Transformer winding conductor , providing re-insulation of LT winding etc. including dismantling the transformer parts i.e. conservator tank, terminal boxes, bushings, removing the core and windings from the tank, draining of transformer oil, cleaning of tank, reassembling the core & windings and all the aforesaid parts after rewinding/repairing, replacement of gaskets, worn out nuts, bolts and washers/cork washers etc, heating in heat chamber, carry out factory tests and submission of test reports etc. complete as required. (The dismantled aluminium winding and other materials can be retained by the agency and credit for the same to be given in the quoted rate of this item)
25 KVA, 11KV/0.415KV, 50 Hz Aluminium wound oil cooled Transformer
25 KVA, 11KV/0.415KV, 50 Hz Copper wound oil cooled Transformer
63 KVA, 11KV/0.415KV, 50 Hz Aluminium wound oil cooled Transformer
63 KVA, 11KV/0.415KV, 50 Hz Copper wound oil cooled Transformer
Supplying and pouring of transformer oil (IS:325) of suitable make & grade for topping up/replacement of old deteriorated oil etc. complete as required.
Filtration and de-hydration of existing Transformer oil at factory / work shop ( In case of rewinding/repairing of Transformer at factory / workshop), testing of BDV and submission of oil testing report etc. as required.
Replacement of the following defective spare parts of the transformer by new one i/c fitting, connection etc. as reqd.
HV Bushings
LV Bushings
Painting of the transformer body with primer & two coats of weather proof synthetic enamel paints after scrapping the rust etc complete as reqd.
Providing 25 KVA/63 KVA 11KV/0.415 KV Distribution class star rated Transformer on hiring basis as a stop gap arrangement etc. as required. (BSNL will not be held responsible for occurrence of any faults in the hired Transformer while working at site or any damage or loss occurred to the said Transformer during transportation, loading, unloading and negligence of the agency etc.). (Commencement date shall be the date of energisation and commissioning at site)
Making arrangements for inspection and testing of the re-winded transformer by the designated inspector of supply company at factory / workshop and obtaining test certificates and clearance for re-installation and energisation of the said transformer etc. complete as required.
Transportation of spare/new/repaired/standby 25/63 KVA transformer from BSNL office /factory /workshop to respective sites and faulty Transformer from sites to back by using suitable transportation medium including loading and unloading at both ends etc. complete as required. (The rate should be inclusive of toll gate fee/charges wherever applicable, nothing extra will be paid. Distance will be on shortest route only).
Distance up to and including 50 KMs (Up and Down)
Distance above 50 KM and up to and including 100 KMs (Up and Down)
Distance above 100 KM and up to and including 150 KMs (Up and Down)
Distance above 150 KM and up to and including 200 KMs (Up and Down)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .