Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-Finance 620 DIAMOND HARBOUR ROAD BEHALA INDUSTRIAL ESTATE PLOT NO F A KOLKATA 34 | KOLKATA | WEST BENGAL | L1 | Accepted-Finance Lowest Bidder | |
| 2 | L2₹9.0 L+₹1.5 L (20.0%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L2 | Rejected-Finance 2nd Lowest Bidder | |
| 3 | L3₹9.7 L+₹2.2 L (29.3%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L3 | Rejected-Finance 3rd Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹25,317
Closing Date
29 Jan 2021, 2:00 pmClosed
Office of SE,SWEC,PWD, MIDNAPORE
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Augmentation of District Drug Reserve Store, Purba Medinipur(in the premises of Tamluk District Hospital) --- SITC of Air-Conditioning System.
2020_WBPWD_291274_4
WBPWD/SE/SWEC/NIQ06/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
TAMLUK
Please refer Tender documents.
3 documents required · 3 mandatory
₹25,317
Office of SE / SWEC, PWD, Midnapore
4 Mar 2021
12 Jan 2021
1 Feb 2021
12 Jan 2021
29 Jan 2021
20 Jan 2021
19 Jan 2021
Amount
AIR CONDITIONING SYSTEM
Supply, Installation, Testing & Commissioning of Microprocessor based air cooled 11TR ceiling suspended ductable type Split Air conditioner having nominal cooling capacity of 132000 BTU/hr.with 1 nos. Scroll Compressor Having High CFM of 4400 Sound Level 54 & R410A Refrigarent ISI condition suitable for operation on 415V, + 5% - 50 Hz. - 3Ph AC supply. Make: Daikin or Equivalent make of Mitsubishi Electric / Hitachi / Carrier / Bluestar / Panasonic) [1 working + 1 standby]
REFRIGERANT PIPING : Installation and commissioning of hard copper refrigerant piping, complete with fittings, elbows, supporting arrangements .
Liquid Line (1/2")
Suction Line (11/8")
REFRIGERANT PIPE INSULATION : Supply & Fixing of Nitrile Rubber tube insulation of 13 mm thick on Copper Pipe. Make -Armacell /K-Flex / A-Flex
DUCT WORK (AIR-DISTRIBUTION SYSTEM)
Factory fabricated pre-insulated PUF duct 20mm thick, including suppy, installation of all duct joints, sealants, supports, Gl turning vanes, accessories to connect grilles & diffusers, matching flanges to metail ducts and internal stiffners. The price shall include the cost of supports which shall be of gripple make wire ropes. Make -PAL / Aaswa
20SWG thick
AIR TERMINAL
Supply & fixing of extruded Aluminium Square Diffusers/ Grille with VCD for Supply Air. Make -(Systemaire/ Caryairel Air master/Dynacraft/Premier/Air enterprise)
Supply & fixing extruded Aluminium Square Diffusers / Grille without VCD for Return Air. Make -(Systemaire/ Caryair el Air master/Dynacraft/Premier/Air enterprise)
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Make -(Systemaire/ Caryair el Air master/Dynacraft/Premier/Air enterprise)
Fire damper
Actuator
Supply and fixing of Fresh air louver with bird screen Make -(Systemaire/ Caryair el Air master/Dynacraft/Premier/Air enterprise)
DRAIN PIPING
Drain Water piping work out of PVC / HDPE hared pipes, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors with insulation
32 mm Dia
Supply,Installation,Testing and Commissioning of split type fixed speed, Non-Inverter Air conditioning machine having the following specification :Maximum EER: 3.59,Compressor Type: Rotary, Rated Cooling Capacity (Watts): 5200, Rated Power Input (Watts) : 1450, Air Volume indoor unit(CFM.): 777, Nano Platium filter, powerful cool and wide & long airflow Air Sleep Cooling Technology, LCD remote control, Electronic metal housing box, 12 hour on and off timer, auto restart, auto swing, fan speed option (low/medium/high) etc. Refrigerant-R410A/R32. Min. BEE Star rating : 3 star,Min.capacity 1.5 Tr. [Make- Mitshubishi Electric, model no- MS/MU GK18VA or eqv. make of O' General / Daikin / Hitachi / Carrier / Bluestar / Panasonic]
Supply,Installation,Testing and Commissioning of (I) Electric cable (3core 2.5sq.mm) (II) Copper pipe 3/8"/1/2" for liquid as required. (III) Copper pipe 5/8" / 1/4"for suction as required (IV) Insulation Foam 3/8" / 1/2" for liquid as required. (V) 5/8" / 1/4"for suction as required. (VI) Drain pipe of PVC for drainage connections for installation of Split A.C. both indoor and outdoor unit.
POWER & CONTROL CABLING
SITC of Wall Mounted Electrical Panel Board consisting of 1 No Main Incoming MCB of suitable rating (ABB/Siemens/L&T), ammeter,on/off indication lamp and 2 nos Outgoing feeder suitable for 11 TR Ductable units. Make - Genpower/ Dynamic control/ Eap/ CPRI approved vendor
Supply & Laying of 1.1 KV Gr. PVC/XLPE insulated, PVC- Sheathed cable, Aluminium armoured for Power cables incl. to laid on wall surface by suitable clamping,proper glanding & finishing the cable ends with solderless sockets for following cables & Copper armoured for Control cable Make - Havells /RR / Gloster / Polycab
4 X 10 sq mm Cu cable
7 Core 1.5sqmm armoured CU.Cable
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size 8 SWG on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Lyric International
SKY DECORATIONS PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .