Executive Engineer, TLMD-II JKPTCL Jammu
Office of the Executive Engineer TLMD-II JKPTCL Jammu
Augmentation of Grid Station Gladnii from 200 MVA to 230 MVA at 132/33 KV Level by way of Replacement of 50MVA EMCO Power Transformer by 80 MVA Power Transformer along with allied works
2026_PDD_313752_1
TLMD-II/08 of 2026-27 dated 25-06-2026
Open Tender
Electrical Works
365 days
Gladni Narwal Jammu
As per SBD
3 documents required · 3 mandatory
₹10,000
Executive Engineer TLMD-II JKPTCL Jammu
₹24 L
Office of the SE O and M Circle I Jammu
26 Jun 2026
26 Jun 2026
18 Jul 2026
26 Jun 2026
17 Jul 2026
26 Jun 2026
26 Jun 2026 - 30 Jun 2026
30 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply of Main Equipments/Material for installation of 80MVA Power Transformer as per specifications of SBD | |||||
| 1.01 | Cost of 80 MVA (ONAN/ONAF), 132/33 kV Three Phase Power Transformers with OLTC, SCADA Compatible RTCC and other required accessories and fittings as required. | - | No | - | - |
| 2Galvanised Structures | |||||
| 3Galvanised Nuts and Bolts | |||||
| 43.5 Core, 25 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete | |||||
| 516 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete | |||||
| 619 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete | |||||
| 7500mm2 ACSR Moose Conductor (a)Aluminium =54/3.53 mm (b) Steel= 7/3.53 mm overall diameter =31.77mm Approx. Wt. =1998 kg/km ultimate strength = 159.60 KN | |||||
| 8Single Tension Fittings For Single 500mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN. | |||||
| 9Single Tension Fittings For Twin 500 mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN. | |||||