Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC ATAL JI KI GALI SHINDE KI CHHAWANI LASHKAR GWALIOR MADHYA PRADESH 474009 | GWALIOR | MADHYA PRADESH | 474009 | L1 | Accepted-AOC AWARD | |
| 2 | L2₹27.8 L+₹1.2 L (4.38%)Rejected-Finance 1ST FLOOR 100 FT ROAD NEAR HERO HONDA AGENCY OPP NARANG CHILDREN HOSPITAL BIBIWALA ROAD NORTH ESTATE | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹28.6 L+₹2.0 L (7.39%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹28.7 L+₹2.1 L (7.74%)Rejected-Finance 15 EMERSON ROAD DANAPUR CANTT PATNA 801101 | PATNA | PATNA | BIHAR | 801101 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹28.8 L+₹2.1 L (7.96%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE
GARRISON ENGINEER DANAPUR CANTT PIN 801503
REPAIR MAINT OF LT OH LINE POLES LT CABLES AND OTHER ALLIED WORKS IN AGE EM UNDER GE DANAPUR
2023_MES_598000_1
GE/DNR/T-01 OF 2023-24 / 8677/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
DANAPUR CANTT
AS PER NIT
8 documents required · 8 mandatory
₹500
GE DANAPUR
₹50,000
Yes
17 Jul 2023
24 May 2023
15 Jun 2023
24 May 2023
13 Jun 2023
8 Jun 2023
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables & foundation of poles , stay assembly and getting out in any type of soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and exc. 1.50 m in depth but not exc 3.0 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cable etc. not exc. 10 Sqm on plan and getting out in any type of soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm each layer ,complete all as specified and directed.
Removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point ,complete all as specified and directed.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable and gentally hand ramming and consolidation etc. complete all as specified and directed. Note :- Thickness of sand shall be measured 18 cm thick after punning.
M & L for old size sub class ‘B’ bricks, laid in trenches as cable covers / protection complete all as specified and directed.
M & L for horizontal boring mechanically across the existing road without disturbing the road surface for inserting 80/40 mm bore GI pipe all complete all as specified and as directed by EIC. ( Note :- GI pipe will be measured and paid respective item of sch'A').
Supply and fixing in repair of GI tubing, light grade, 40 mm bore with all fitting lais in trenches / pole / wall for protection of cables complete all as specified and directed.
Supply and fixing in repair of GI tubing, light grade, 80 mm bore with all fitting laid in trenches / pole / wall for protection of cables complete all as specified and directed.
M & L for plain cement concrete, 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
Supply and erecting steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-31 (9 meter long) complete, Including disconnecting and taking out old damage PCC pole all as directed. Note Excavation & Earth work and PCC foundation/base shall be measured and paid separately under relevant items of this BoQ.
S&F Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for LT size 20 X 15 Cm fix in repairs complete all as specified and directed.
Material and labour LT Cable rout indicator made out of PCC Post of 1:2:4 using 20mm graded stone aggregate of size not less than 20 x 15 cm and one meter height with making embossing the following letters of size 100 mm in the PCC Post " LT CABLE with ARROW" including necessary excavation and PCC 1:2:4 (30 X 30 x 30 CM ) for embeding in the ground complete all as specified and directed.
Dismantling and taking out servicable insulators of any size and any type from existing poles / dismantled poles / pole structures complete all as specified and directed.
Fixing only insulator of any size and any type to LT over head line as directe including fixing accessories complete with suitable sizecomplete all as specified and directed. NOTE :- Insulators are obtained under item No. 15 shall be re-used
M & L Pin type, porcelain, vitreous, white, brown or green insulator, 100mm height, 65 mm dia for 1100 volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut complete all as specified and directed.
M&L for Shackle type insulator from LT overhead line and S&F new Shackle type, porcelain, vitreous, white, brown or green insulators 100mm dia and 115 mm height for working pressure 1100 volts including galvanised mild steel strap 31 x 3mm size, washers, 14mm dia insulator bolts, washers & nuts complete all as specified and directed.
Cutting of grass, at sub stations / EM Istallations and surrounding areas etc complete or when and where directed and removing the same from site to a distance not exceeding 50 mtr complete and spreading of bleaching powdeer at the rate 1 kg/10 sq metre for stop the abnomal grouth of grass complete all as specified and directed.
S & F in repair for LT line PVC Spacers spiral type for the following :-
Spacer for three wire
Spacer for four wire
Supply and fixing four pole changeover switch disconector with advance neutral 415 volt 50 Hz 200 amps in sheet steel enclosure and Conforming to IS / IEC : 60947 - 3 including dismantling old u/s changeover switch disconnector complete all as directed. Make - L & T /Siemens/Schneider.
Removing of old Un used /Damage LT PCC / Steel pole PCC including excavation retureing filling & breaking of PCC foundation & deposited to store or removing from site complete all as directed as directed.
M & L for Earthing to OH/Sub stn with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 32 x 6 mm galvanised iron strip dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 of MES Schedule pt-I 2009, GI earth strip 32 x 6 mm protected by GI pipe 40mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete.
Supply and fixing in repair for Earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip, buried in ground or fixed to wall complete all as specified and directed.
Taking up underground unservicable cable of any size from existing trench including bricks, etc and removing of materials from work site complete all as specified and directed. Note : Excavation, returning filling & removing shall be measured & paid separately under relevant item of BOQ
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 150 sqmm 3.5 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (NOTE: Earthwork GI pipe, brick protection etc shall be measured and paid separately under relevant items of BOQ).
All as per ser item No 26 above but of cross sectional area 120 sqmm 3.50 core
All as per ser item No 26 above but of cross sectional area 95 sqmm 3.50 core
All as per ser item No 26 above but of cross sectional area 25 sqmm 4 core
All as per ser item No 26 above but of cross sectional area 16 sqmm 4 core
All as per ser item No 26 above but of cross sectional area 10 sqmm 2 core
M & L for PVC insulated, stranded aluminium conductor served with inner sheathing PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm dia GI suspension wire of wire 10 Sqmm 2 core,complete all as specified and directed .
Supply and fixing MCCB adjustable thermal magnetic release type, 4 poles, 415 Volts, Lcu = 100% Ics, 36 KA breaking capacity of rating 320-400 Amps including all fixing accessories with both ends spreader links and disconnecting and taking out old U/S MCCB complete all as directed. Make -Seiman / Legrand / L&T.
Supply and fixing MCCB adjustable thermal magnetic release type, 4 poles, 415 Volts, Lcu = 100% Ics, 36 KA breaking capacity of rating 160-200 Amps including all fixing accessories with both ends spreader links and disconnecting and taking out old U/S MCCB complete all as directed. Make -Simence / Legrand / L&T.
Supply and fixing MCCB adjustable thermal magnetic release type, 4 poles, 415 Volts, Lcu = 100% Ics, 36 KA breaking capacity of rating 100-125 Amps including all fixing accessories with both ends spreader links and disconnecting and taking out old U/S MCCB complete all as directed. Make -Simence / Legrand / L&T. NOTE FOR ITEM NO -32 TO 35 :- MCCB shall be replaced as per existing frame size and model as per requirement of site.
Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 120 to 70 sqmm 3.5 core cable complete all as specified and as directed Make : Raychem / 3M / Denson.
Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 50 to 25 sqmm sqmm 3.5 core cable complete all as specified and as directed Make : Raychem / 3M / Denson.
Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 16 to 10 sqmm 4 core cable complete all as specified and as directed Make : Raychem / 3M / Denson.
Supply and fixing in repair for PVC Sleeves heat shrink type of 16 Sqmm to 70 Sqmm size single core of for providing underground cable/bus bar insulation as per colour required at site complete all as specified and as directed by EIC.
Supply and fixing in repair for PVC Sleeves heat shrink type of 95 Sqmm to 185 Sqmm size single core of for providing underground cable/bus bar insulation as per colour required at site complete all as specified and as directed by EIC.
S & F in repair for three phase Amp meter Size 96 mm x 96mm square flush type and analog type capacity including taking out defective existing Amp meter complete all as directed.
S & F in repair Indication lamp (RYB) LED type with toggle switch & control fuses complete all as directed.
S & F in repair Volt meter digital type of range 0- 500V complete all as directed by EIC.
S & F in repair Ammeter with seletor switch for (0- 100 Amps) complete all as directed by EIC.
Supply and fixing in repair current transformer (CT) 240 volts 50 Hz of ratio 50/5A,100/5A, 200/5A as per existing size and model complete all as specified and as directed.
M/S Priya Trading Agency
M/S SHATRUGHAN SINGH CHAUHAN
M/S SAROJ KUMAR SINGH
HARINANDAN RAI SONS
VAISHNAVI CONSTRUCTION
jaglalchoudharyandsons
SINHA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .