Shri Niranjan Lal, GE(S)BTD
GE(S) BATHINDA BATHINDA MIL STN
REPAIR TO CEILING FANS EXHAUST FANS WALL MOUNTING FANS AND PEDESTAL FAN AND OTHER CONNECTED EM WORKS IN MD ACCN AND CERTAIN EM REPAIRS IN CENTRAL AMENITIES UNDER AGE EM IV OF GE SOUTH BATHINDA MIL STN
2020_MES_319566_1
GE (S) BTD-52/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BATHINDA MIL STN
AS PER NIT
7 documents required · 7 mandatory
₹500
GE(S) BATHINDA
₹61,800
Yes
9 Mar 2020
29 Jan 2020
18 Feb 2020
29 Jan 2020
15 Feb 2020
10 Feb 2020
30 Jan 2020 - 6 Feb 2020
Amount
M&L for collecting unserviceable ceiling fans 1200mm sweep 230 V, AC, single phase from store yard of AGE E/M, opening the ceiling fan and taking out complete burnt winding from fan motor and rewinding the same with super enameled copper winding wire of existing gauge & size including thoroughly cleaning all the components of fan, oiling varnishing the fan with and including replacement of rusted/unserviceable nuts, bolts, split pin, rubber reel, flexible twin core copper cable of size 23/.00076 approximate one metre long for each fan, machine screws etc, depositing the repaired fan to store yard complete all as specified and directed by Engineer-in-charge.
All as per item No.1 here-in-before but 1400mm sweep fan of any make & type/model complete all as specified and directed by Engineer-in-charge.
All as per item No.1 here-in-before but exhaust fan of size 450 mm sweep of any make & type / model complete all as specified and directed by Engineer-in-charge.
All as per item No.1 here-in-before but exhaust fan of size 380 mm sweep of any make & type/model complete all as specified and directed by Engineer-in-charge.
All as per item No.1 here-in-before but exhaust fan of size 350 mm sweep of any make & type/model complete all as specified and directed by Engineer-in-charge.
All as per item No.1 here-in-before but exhaust fan of size 225 mm sweep of any make & type/model complete all as specified and directed by Engineer-in-charge.
All as per item No.1 here-in-before but wall mounting fan of any sweep / make & type/ model complete all as specified and directed by Engineer-in-charge.
All as per item No.1 here-in-before but for Air Circulator, Pedestal fan of size 600mm sweep complete of any type/model. Note For Srl No.1 to 8:- The rewinding shall be carried out in the AGE E/M Store Yard for which rent as per Clause No.16 of PSS-II will be deducted from contracator's payment complete all as specified and directed by Engineer-in-charge.
Taking out defective capacitor and supply & fixing dry type capacitor of capacity 2.5 MFD suitable for any make and type of fan complete all as specified and directed by Engineer-in-charge.
All as per item No.9 here-in-before but of capacity 4 MFD complete all as specified and directed by Engineer-in-charge. Note For item No.9 & 10:- Capacitor shall be replaced in workshop as well as at site as per requirement.
Taking out the defected ball bearing of ceiling fans/ exhaust fans/ air circulator fans / cabin fans/ table fans/ pedestal fans and supply & fixing new ball bearing suitable for existing housing of No.6201, 6202 complete all as specified and directed by Engineer-in-charge.
All as per item No.11.00 (here-in-before) but of No. 6203 complete all as specified and directed by Engineer-in-charge.
Taking out the worn out Gun Metal Bush and supply and fixing new Gun metal bush of suitable size for any sweep and make of ceilingl fan/ exhaust fan/ pedestal fan / table fan / air circulator / cabin fan complete all as specified and directed by Engineer-in-charge.
Supply and fixing resistance type regulator with five stepping for ceiling fan 1200mm/1400mm sweep type 230V complete including taking down defective/unserviceable regulator complete all as specified and directed by Engineer-in-charge.
S & F fan Regulator stepped type electronic suitable watt, flush type 230/240 volt for 1200 / 1400 mm sweep ceiling fan & connecting up complete on body & base of laminated top sheet cover complete all as specified and directed by Engineer-in-charge.
Taking out the worn out / defective blades of ceiling fan of 1200 mm sweep and supply & fixing new aluminium blade of same size in set of three alongwith fixing screws and spring washers complete all as specified and directed by Engineer-in-charge.
All as per item No.16.00 (here-in-before) but ceiling fan of size 1400mm sweep complete acomplete all as specified and directed by Engineer-in-charge.
Taking out the old defective rod and supply and fixing new down rod 300mm long for any make and of any type of ceiling fan complete having two Nos holes ccomplete all as specified and directed by Engineer-in-charge.
Supply and fixing 'U' clamp and rubber reel, nut, bolt and spit pin of superior quality for ceiling fan complete all as specified and directed by Engineer-in-charge.
Taking out old worn out / broken canopy set and supply and fixing new canopy set suitable for any make/ size ceiling fan complete all as specified and directed by Engineer-in-charge.
Painting of ceiling fan of size 1200/1400mm of any make including preparation surface and making smooth the surface of body, blade, down rod etc even and smooth/fair for painting one coat of white synthetic enamel paint with spray gun complete all as specified and directed by Engineer-in-charge.
Writing MES Nos on fan with black synthetic enamel paint complete all as specified and directed by Engineer-in-charge.
Taking out old broken bottom cover and supply and fixing new bottom cover with screw suitable for 1200/1400mm sweep of ceiling fan as per sample / size / make of fan complete all as specified and directed by Engineer-in-charge.
Provn of machine work for fitting/fixing to bearing / bushes of ceiling fan/ exhaust fan of any make & size with grinding of shaft or sheets after brazing work with suitable size of metal rods for proper fixing / fitting and avoid to un wanted noise alcomplete all as specified and directed by Engineer-in-charge.
Blade screw suitable for various sizes / make ceiling fan ccomplete all as specified and directed by Engineer-in-charge.
M&L for servicing & checking for safety of ceiling fanat Bldgs of various locations, taking down checking of rubber bush, nut, bolt and locking pin of ceiling hook of fan, down rod etc for safety to avoid fall down the ceiling fan and rectify by replacing new spare / componets complete all as specified and directed by Engineer-in-charge. Note : (1). Spares reqd to be replaced will be measured separatly. (2). Record of checking/serviceability of ceiling fan reqd to be maintained with user's signature.
Attending complaint of ceiling fan/exhaust fan/wall fan at various locations by replacing spare parts/complaints etc complete all as specified and directed by Engineer-in-Charge. Note :(i) The contractor or his representative will attand the office of the Engineer-in-Charge daily (working day) at 0930 hours to collect the complaint slip and will provide two mechnics for repair the fans and cost of the same is included in the quoted rate.The complaint will be completed/done within 24 hours from the time of issue of complaint slip, failing which a panel recovery of Rs 50/- per complaint per daywill be recovered from contractor due's and contractor will not have any claim on this account complete all as specified and directed by Engineer-in-charge. (ii) Spare parts required against rectification/repair will be measured and paid for saperately)
S&F fan hook size of 15 mm dia MS bars, fixed to RCC roof for hanging of ceiling fan complete all as specified and directed by Engineer-in-charge.
Taking down carefully existing unserviceable copper / aluminum point wiring (light, fan, socket) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, etc and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and directed by Engineer-in-Charge.
M&L point wiring for one light point / bell point /ceiling fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FR-LSH in and including concealed PVC conduit 20 mm dia, medium duty, ISI marked including new, steel terminal sunken boxes suitable of modular switch/socket flush to surface for one light point, fan point , controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable FR-LSH connected to common earth dolly complete including cutting, chasing the surface and then making good the same in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed by Engineer-in-charge. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of Sch 'A' ).
All as per item No 30 but for socket outlet 5 pin, 6 Amp on same board complete all as specified and directed by Engineer-in-charge.
All as per item No 30 but for socket outlet 5 pin, 6 Amp on independent board complete all as specified and directed by Engineer-in-charge.
All as per srl item No. 30 (here-in-before) but for one socket outlet 6 pin, 6/16 Amp with cable of 2.5 Sq mm, multi stranded copper conductor FRLSH cable on the independent board including provision of 2.5 Sq mm PVC insulated unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 30 here in before but for one light point controlled by two way switch complete all as specified and directed by Engineer-in-Charge.
All as per item No 30 here in before but for call bell point complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing modular switch piano, flush type, one way, 5/6 Amps 230 Volts AC (ISI marked) including decorative frame cover etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Switch piano, Modular flush type, two way, 5/6 Amps 230 V AC (ISI marked) including decorative frame cover etc complete all as specified and as directed by Engineer-in-Charge.
S&F 6 Amps bell push switch, modular type, 250 volts, AC ISI marked complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing modular, One switch and one socket outlet, 5 Pin, 6 Amps 230 Volts AC (ISI marked) including decorative frame cover etc complete all as specified and as directed by Engineer-in-Charge. Note:- Switch and socket shall be of same make
Supply and fixing modular, One switch and one socket outlet, multipurpose 3 Pin, 5 Amp and 6 pin 15 Amp, 230 Volts AC (ISI marked) including decorative frame cover etc complete all as specified and as directed by Engineer-in-Charge. Note:- Switch and socket shall be of same make
Supply and fixing modular fan regulator electronic step type (1-4), socket type 230-240 Volt AC supply with frame complete all as specified and as directed by Engineer-in-Charge
Material and Labour for point wiring with multi stranded copper conductor FRLSH cable, 1100 volts grade PVC insulated and unsheathed of size 1.5 Sqmm single core in and including PVC concealed conduit not less than 20mm dia ( medium quality ISI marked) and conduit fittings and MS sunken box of suitable size covered with and including 3 mm thick bakelite laminated sheet top cover for one fan / light controlled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly including cutting chasing of wall and making good disturbed surface in CM (1:3) and finishig the surface to match complete all as specified and directed by Engineer-in-Charge.Note:- ( Switch and socket etc shall be measured and paid separately under approriate items of BOQ).
All as per item No 42 but for socket outlet 5 pin, 6 Amp on same board complete all as specified and directed by Engineer-in-charge.
All as per item No 42 but for socket outlet 5 pin, 6 Amp on independent board complete all as specified and directed by Engineer-in-charge.
All as per srl item No. 42 (here-in-before) but for one socket outlet 6 pin, 6/16 Amp with cable of 2.5 Sq mm, multi stranded copper conductor FRLSH cable on the independent board including provision of 2.5 Sq mm PVC insulated unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 42 here in before but for one light point controlled by two way switch complete all as specified and directed by Engineer-in-Charge.
All as per item No 42 here in before but for call bell point complete all as specified and as directed by Engineer-in-Charge.
M & L for point wiring for one light / fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FR-LSH in existing conduit, and existing sunken boxes but including 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FR-LSH connected to common earth dolly complete including cutting, chasing the surface and then making good the same in CM (1:3) complete all as specified and directed by Engineer-in-charge.(Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of Sch 'A' ).
All as per item No 48 but for socket outlet 5 pin, 6 Amp on same board complete all as specified and directed by Engineer-in-charge.
All as per item No 48 but for socket outlet 5 pin, 6 Amp on independent board complete all as specified and directed by Engineer-in-charge.
All as per srl item No. 48 (here-in-before) but for one socket outlet 6 pin, 6/16 Amp with cable of 2.5 Sq mm, multi stranded copper conductor FRLSH cable on the independent board including provision of 2.5 Sq mm PVC insulated unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 48 here in before but for one light point controlled by two way switch complete all as specified and directed by Engineer-in-Charge.
All as per item No 48 here in before but for call bell point complete all as specified and as directed by Engineer-in-Charge.
S& F semi modular type switch piano flush type, 6 Amp 240 Volt, AC (ISI Marked) one way etc complete all as specified and directed by Engineer-in-charge.
S& F semi modular type switch piano flush type, 6 Amp 240 Volt, AC (ISI Marked) two way etc complete all as specified and directed by Engineer-in-charge.
S&F semi modular one switch & one socket outlet 5 Pin 5 Amp 230 volts AC including decorative frame cover etc complete all as specified and directed by Engineer-in-charge. Note:- Switch and socket shall be of same make.
S&F semi modular one switch and one socket outlet multipurpose 3 Pin 5 Amp and 6 Pin 15 Amp 230 volts AC ncluding decorative frame cover etc complete all as specified and directed by Engineer-in-charge. Note:- Switch and socket shall be of same make.
S&F 6 Amps bell push switch, modular type, 250 volts, AC ISI marked complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing call bell Ding-dong, 230 Volts AC supply complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing semi modular type regulator for ceiling fan electronic step type suitable for 1200/1400 ceiling fan complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing lamp holder angle/straight, including LED bulb 9/10W polycarbonate cased body with back plate suitable for batten fittings for landing T & wind shock complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing sheet metal enclosures double door made out of CRCA mild steel sheet, flush mounted, acrylic door, 8 way, DB SPN 230 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old DB of any type and capacity alongwith MCB etc complete all as specified and as directed by Engineer-in-Charge.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, flush mounted, acrylic door, 4 way, DB TPN 415 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old DB of any type and capacity alongwith MCB etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 12 way VTPN with MCCB 125A double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting 230 Volt, with 200 Amp etc including taking down old VTPN of any type and capacity complete all as specified and directed by Engineer-in-charge.
Supply and fixing single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 Volt complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB, SP, 6 to 32 Amps, 'C' curve, 230 Volts, breaking capacity not less than 10 KA with over load and short circuit protection complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB, SPN, 40 to 63 Amp, 230 Volts, 'C' curve breaking capacity not less than 10 KA with over load and short circuit protection,50 Hz including necessary attachment complete all as specified and as directed by Engineer-in-Charge
Supply and fixing MCB, TPN, 100 Amp, 230 Volts, 'C' curve breaking capacity not less than 10 KA with over load and short circuit protection,50 Hz including necessary attachment complete all as specified and as directed by Engineer-in-Charge
Material and Labour for sub main wiring with 2 single core cable 6 sqmm, 1100 votls grade PVC insulated unsheathed of copper multi strandard conductor FRLSH cable with continuous copper earth conductor of size 6 sqmm, 1100 votls grade drawing through in & including PVC concealed conduit medium grade of size 20mm along with accessories such as Tee, elbow, bend etc including taking down old sum in wiring of any type and capacity complete all as specified and as directed by Engineer-in-Charge. Note :- Two runs of cable and one run of earthing wire shall be measured as one unit.
Material and Labour for sub main wiring with 2 single core cable 6 sqmm, 1100 votls grade PVC insulated unsheathed of copper multi strandard conductor FRLSH cable with continuous copper earth conductor of size 6 sqmm, 1100 votls grade drawing through existing PVC concealed conduit medium grade of size 20mm along with accessories such as Tee, elbow, bend etc including taking down old sum in wiring of any type and capacity complete all as specified and as directed by Engineer-in-Charge. Note :- Two runs of cable and one run of earthing wire shall be measured as one unit.
S & F in repair energy efficient LED street light of 25 Watt with PDC aluminium body and clear glass with lens for wide beam distribution, top maintainable type with IP 66 degree of protection, PF>0.95 with voltage range 140 to 170 Volt, fitting should be provided with inbuilt 5KV minimum surge protection, short circuit and over voltage protection facility for driver and fitting including 25 watt LED lamp with GI bracket-01 No, MS clamp-02 Nos suitable for walls/columns metre long twin core round copper conductor cable of 1.50 metre long twin core round copper conductor cable of suitable size and testing complete all as specified and directed by Engineer-in-charge. Make:- SYSKA cat part No. SSK-SLF-CF-25W-WL or equivalent model of any make given in Appendix 'B' of tender documents, Cat Part No. as approved by GE.
S & F in repair surface mounted, LED ceiling light 230 Volt, 12 watt the system wattage of fitting should not be more than 5 watt ± 10%, surge protection of minimum 2KV, power factor should be more than 0.90, cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 540 lumens, total input voltage range 140-280V AC, colour rendering Index should not be less than 80 complete fitting and all other accessories including electric connection connecting with using flexible copper wire twin core complete all as specified and directed by Engineer-in-charge. Make:- Crompon cat part No. LCSR-12-CDL or equivalent model of any make given in Appendix 'B' of tender documents, Cat Part No. as approved by GE. Note:- The rate of LED lamp of 12 watt base is deemed to be included in the quoted rate.Nothing extra shall be paid on this account.
S & F in repair surface mounted, decorative round bulk head luminaire comprising of high brightness LED lamp 10/12 Watt, 6000K polycarbonate with IP65 protection, the system wattage of fitting should not be more than 5 watt ± 10%, surge protection of minimum 2KV, power factor should be more than 0.90, cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 900 lumens, total input voltage range 140-280V AC, colour rendering Index should not be less than 80 complete including all other accessories and fitting arrangement including electric connection connecting with using flexible copper wire twin core upto ceiling rose/conector. Make:- Crompon cat part No. LBHE-10-CDL or equivalent model of any make given in Appendix 'B' of tender documents, Cat Part No. as approved by GE.
Supply and fixing in repair LED mirror light of 07 watt, 6000K, linear & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete including 07 watt tube rod make all as Model No LCL-7 od Crompton or equivalent model of any make given in Appendix 'B' of tender documents, Cat Part No. as approved by GE, complete connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing SITC high bay LED150 W IP66 with excellent heat dissipation, light in weight and small in size with system high lumen efficacy including fixing with suitable size clamps, nuts, bolts etc. at a height of about 12 m complete all as specified and as directed by Engineer-in-Charge. Note:- (i) The point wiring with 2.5sqmm under the conduit is approximate 15mtr height from switches ( Poles of street light). (ii) The contractor should deploy experience labour with proper arrangement like ladder, tools etc as per site requirement. (iii) The contractor sholud provide all safety precaution to the labour during work. No extra payment is to be given on this account. (iv) The contractor should provide original purchase voucher, test certificate, lm-79 report from the manufacturer of LED light (v) There should be unconditional guarantee/warranty of LED fittings for minimum guarantee period of two years for which the contractor is liable. (vi) The contractor should visit the site before quoting the rate. (vii) Taking down of old retrieved fittings shall be included in the quoted rate. All fittings shall be deposted to AGE E/M-IV store yard.
Supplying fixing, testing and commissioning AC 240 volt single phase tamper proof electronic whole current energy meter (Polycarbonate body LCD display), accuracy class 1.0 rating, range 10 Amp to 60 Amp, with pilfer proof meter box and sealing screw. The meter shall comply with the latest version of line load reversal and earth loading indication and shall work satisfactory with guarantee accuracy as per limit of IS-13779. The meter shall be fixed in existing sheet box on wall including cable connection (inlet and outlet) and proper sealing with KWH lead sealing tablets & wire including takng down old meter and deposited to AGE E/M-IV office with details such as building No, older meter No, New meter No, initial reading, date of installation etc complete all as specified and directed by Engr-in-charge.
Supplying fixing, testing and commissioning AC 240 volt single phase tamper proof electronic whole current energy meter (Polycarbonate body LCD display), accuracy class 1.0 rating, range 10 Amp to 40 Amp, with pilfer proof meter box and sealing screw. The meter shall comply with the latest version of line load reversal and earth loading indication and shall work satisfactory with guarantee accuracy as per limit of IS-13779. The meter shall be fixed in existing sheet box on wall including cable connection (inlet and outlet) and proper sealing with KWH lead sealing tablets & wire including takng down old meter and deposited to AGE E/M-IV office with details such as building No, older meter No, New meter No, initial reading, date of installation etc complete all as specified and directed by Engr-in-charge.
S & F in repair LED Tube rod 18W/ 20W/ 21W/ 22W, Polycarbonate body, 1.2m length, LED T8 (Tubular lamp), 6500K, G13 Lamp holders, 230V, 50Hz with & including precoated CRCA frame/ fitting suitable for holding T8 LED tubular Lamps, 1.2m length, 230V, 50Hz. The frame should be compatible with LED. The total fitting should be complete including LED driver, other accessories and rest complete all as specified and directed by Engineer-in-charge. Note: (i) The LED tube rod and CRCA frame should be of same make and they should be compatible with each other. (ii) The LED Tube shall be warranted for two years from the date of completion of work.
S/F in repair LED Tube rod ecofriendly, 20W/22W polycarbonate body, 1.20m length, LED T8 (tubular lamp), 6500K, G13, 230V, 50Hz complete all as specified and directed by Engineer-in-charge.
S/F in repair LED Tube rod ecofriendly, 8W/9W polycarbonate body, 0.60m length, LED T8 (tubular lamp), 6500K, G13, 230V, 50Hz with and including CRCA fitting/batten suitable for holdinhg T8 LED tubular Lamps, 0.6m length, , 230V, 50Hz. The frame should be compatible with LED. The total fitting should be complete including LED driver, other accessories and rest all as directed by Engr-in-Charge. Note :- The LED tube rod and CRCA frame should be of same make and they should be compatible with each other complete all as specified and directed by Engr--in-Charge
S&F in repair Intergal post top lanterns Moulded plastic capsul which houses lamp holder for x11 w led bulb including 1x11w LED bulb and connection of light complete all as specified and as directed by Engr-in-charge.
S&F in repair decorative wall mounting light fixture made up of poly carbonate with 7 watt LED bulb ( B-22 base) complete all as specified and directed by Engineer-in-charge.
S & F in repair LED Post Top fitting of 25W, energy saving, environmental friendly, powder coated aluminium die cast and spun aluminum with clear/opal diffuser and suitable for landscape lighting complete all as specified and directed by Engr-in-charge. Make:- Polycab cat part No PGR0201007 (PRODUCT CODE) or equivalent model of any make given in Appendix 'B' of tender documents, Cat Part No. as approved by GE.
S&F in repair GI tubing light grade 40 mm dia cut into suitable length including all fittings and fixtures for base of post top lantern etc complete all as specified and directed by Engr-in charge.
Material and labour for cement concrete (1:4:8), type D-2 using 40 mm graded stone aggregate as in pole foundation etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for cement concrete (1:3:6), type C-1 using 20 mm graded stone aggregate as in coping etc complete all as specified and as directed by Engineer-in-charge.
Supplying and fixing in repair 1100 volts grade heavy duty cable 10 Sqmm solid conductor PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular including taking down old service wire of any type and section complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair 18/20 watt Retro LED tube light fitting, wall/surface mounted, IP 20 protection, conforming to IS16106/IS16107, minimum 6000K batten decorative type 4 feet long polycarbonate body, white , in built LED driver, power factor >0.95, Make all as per Compton cat part No. DMLN1LT8-16( for batten) and Cat Paert No. LT8-20-865-2( for tube light) including 18/20 watt tube rod or equivalent model of any make given in Appendix 'B' of tender documents, Cat Part No. as approved by GE complete connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair rigid non-metallic PVC conduit 25mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as plers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (PCC 1:2:4 B-1 using 20 mm graded stone aggregates for concrete pit including 10 mm thick PCC slab cover frame) depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including GI pipe 20 mm dia light grade for watering and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point, all as specified as shown in electrical plate No 3 SSR Part-I and testing on completion including taking down old earthing complete all as specified and as directed by Engineer-in-Charge. Note :- PCC chamber shall be constructed at least 1.5 m away from earth pit pipe for watering shall be provided in slanting manner.
S&F in repair GI tubing light grade 32 mm dia cut into suitable length including all fittings and fixtures for base of post top lantern etc complete all as specified and directed.
S & F in repair LED Post Top fitting of 15W, energy saving, environmental friendly, powder coated aluminium die cast and spun aluminum with clear/opal diffuser and suitable for landscape lighting complete all as specified and directed. Note:- Sample will be approved by GE from list of make attached in tender documents before bulk procurement.Nothing extra shall be paid on this account.
S & F in repair decorative garden light of height 2 to 3 feet which houses lamp holder for 1x11 W including LED bulb of 11W, energy saving, environmental friendly suitable for landscape lighting complete all as specified and directed. Note:- Sample will be approved by GE from list of make attached in tender documents before bulk procurement.Nothing extra shall be paid on this account.
SWARN SINGH AND CO.
Aman Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .