Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 CrAdmitted-Finance | ₹6.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹7.1 Cr+₹68.0 L (10.5%)Admitted-Finance | ₹7.1 Cr+₹68.0 L (10.5%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical REJECT |
| Sl No | Description | Qty | Unit | Bee Pee Electricals L2 | REW Constructions Private Limited L1 |
|---|---|---|---|---|---|
| 1.00Cartage of following material from Store centre, Mathura to work site. | |||||
| 1.01 | ST Pole (11 mtr. Long)
(Bottom Portion Galvanized) | 248 | No | - | - |
| 1.02 | PCC Pole (8.5 mtr. Long) | 144 | No | - | - |
| 1.03 | ST Pole Pole (13 mtr. Long)
(Bottom Portion Galvanized) | 39 | No | - | - |
| 1.04 | 11/0.43 KV 400 KVA T/F | 8 | No | - | - |
| 1.05 | 11/0.43 KV 250 KVA T/F. | 16 | No | - | - |
| 1.06 | 11/0.43 KV 100 KVA T/F. | 17 | No | - | - |
| 1.07 | 11/0.43 KV 63 KVA T/F. | 20 | No | - | - |
| 1.08 | LT Aerial Bunch conductor. 3x120 Sq.mm. | 998 | Mtr. | - | - |
| 1.09 | LT XLPE cable AL 1X400 sq.mm. | 120 | Mtr. | - | - |
Tender Value
₹6.2 Cr
EMD Value
₹7 L
Closing Date
8 Nov 2023, 12:00 pmClosed
SE, EUDC, MATHURA
SE, EUDC OFFICE, NEAR TANK CHAURAHA, MATHURA
Carrying out various electric works on Semi Turn Key basis for system strengthening in Municipal area in the area of EE, EUDD II, Mathura under the jurisdiction of SE, EUDC, Mathura
2023_DVVNL_843345_1
39/EUDC(M)/2023-24
Open Tender
Electrical Works
Turn-key
90 days
EE, EUDD II
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
dvvnl.org
₹7 L
29 Nov 2023
26 Sept 2023
8 Nov 2023
26 Sept 2023
8 Nov 2023
26 Sept 2023
Cartage of following material from Store centre, Mathura to work site.
ST Pole (11 mtr. Long) (Bottom Portion Galvanized)
PCC Pole (8.5 mtr. Long)
ST Pole Pole (13 mtr. Long) (Bottom Portion Galvanized)
11/0.43 KV 400 KVA T/F
11/0.43 KV 250 KVA T/F.
11/0.43 KV 100 KVA T/F.
11/0.43 KV 63 KVA T/F.
LT Aerial Bunch conductor. 3x120 Sq.mm.
LT XLPE cable AL 1X400 sq.mm.
LT PVC cable 1x630 sq.mm.
LT PVC cable 1x400 sq.mm.
AL XLPE cable 1x630 sq.mm.
AL. XLPE 1X400 sqmm. Cable
AL. XLPE 1X240 sqmm. Cable
LT PVC cable 3.5x150sq.mm.
LT PVC cable 3.5x240sq.mm.
LT PVC cable 3.5x70sq.mm.
33 KV XLPE Cable 3x300 Sq.mm.
11 KV XLPE Cable 3x185 Sq.mm.
11 KV XLPE Cable 3x70 Sq.mm.
2Cx10 Sq.mm. armoured cable
4x10 Sq.mm. armoured cable with catenary arrangement
Indoor Cable Jointing Kit I/D 11 KV 3x185 Sq.mm.
Outdoor Cable Jointing Kit O/D 11 KV 3x185 Sq.mm.
Straight Through for 11 KV 3x185 Sq.mm.
Outdoor Cable Jointing Kit O/D 11 KV 3x70 Sq.mm.
Outdoor Cable Jointing Kit O/D 33 KV 3x300 Sq.mm.
ACSR Ins. Weasel conductor
ACSR Weasel conductor
ACSR Dog conductor
D.O. Fuse Set for 11 KV
Cartage of above material like various size 33 KV, 11 kv cable, dog/weasel conductor, Jointing kit, vaccume interrupter, distribution transformers, ST/PCC Pole, VCB, insulator, Disc. fitting, control panel, pin insulator, bus isolator, Line isolator, Bus coupler, brass glands, channel, clamps etc. from Store Center, Mathura to work site and dismentled material from site to dvvnl store.
Digging of pit & erection of new single support ST Pole (13/11 mtr. long) including grouting of pole and fixing of all clamps, cross arm, pin/disc insulator & other accessories with providing stone pad as per relevant drawings. Any fabrication if required for above support.
Digging of pit & erection of new Double Pole Structure ST Pole (13/11 mtr. long) including grouting of pole and fixing of all Sturucture accessories, clamps, cross arm, pin/disc insulator & other accessories with providing stone pad as per relevant drawings. Any fabrication if required for above support.
Earthing of ST/PCC pole/Body earthing of T/F. by M.S earth rod.
Providing & fixing of MS Nut, Bolt and Washer's
Providing & Painting of ST pole with aluminum paint and Red oxide.
Digging of pit & erection of Stay rod with grouting cement sand and brick ballast including Nuzzling, binding Complete. (Stay Insulator providing by contractor)
Filling & Fixing of 11 KV Indoor type cable Jointing Kit for 11 KV 3x185 sqmm.XLPE cable
Filling & Fixing of 11 KV Outdoor type cable Jointing Kit for 11 KV 3x185 sqmm.XLPE cable
Filling & Fixing of 11 KV cable Jointing Kit (Straoght Through) for 11 KV 3x185 sqmm.XLPE cable
Filling & Fixing of 11 KV Outdoor type cable Jointing Kit for 11 KV 3x70 sqmm.XLPE cable
Filling & Fixing of 33 KV Indoor type cable Jointing Kit for 33 KV 3x300 sqmm.XLPE cable
Sagging of Weasel/Dog conductor on erected poles.
Sagging/Jumpering of Ins. Weasel/Dog conductor
Digging of trench by Making pits/open trench method/HDD method after due survey with the help of utility detector of existing electrical/telephonic cable/and other utilites of public utilites department and laying , Testing, Commisiong & energization of cables of 33 KV/11 kv XLPE double ckt. Cable by manual drill (by making moles) /HDD method/ open trench Including all material Like brick & sand and Back filling and restoring the road to make as original.
Sagging & Laying of 33/11 KV XLPE cable in Double Pole structure/Loop etc.
Laying of Laying of 2c/10 sq.mm. armoured Cable
Laying of 4X10 XLPE armoured Cable With Catenary arrange ment
Digging of trench by Making pits/open trench method/HDD method after due survey with the help of utility detector of existing electrical/telephonic cable/and other utilites of public utilites department and laying , Testing, Commisiong & energization of cables of LT XLPE/PVC/Al. double ckt. Cable by manual drill (by making moles) /HDD method/ open trench Including all material Like brick & sand and Back filling and restoring the road to make as original.
Sagging & Laying of LT cable 3.5x150/240sq.mm.
Laying of LT ABC 3X120 sq.mm. Cable
Laying LT XLPE cable AL 1X400 sq.mm.
Laying LT PVC cable 1x630 sq.mm.
Laying LT PVC cable 1x400 sq.mm.
Laying AL XLPE cable 1x630 sq.mm.
Laying AL. XLPE 1X400 sqmm. Cable
Laying AL. XLPE 1X240 sqmm. Cable
Guarding of 33KV/11 KV line. (including G.I. Wire and other related items)
Providing and Fixing of 11 KV Holding Clamp For ST Pole
Providing & fixing of G.I. Pipe 4"/6" dia
Providing & fixing of Clamp For G.I. Pipe
Providing & fixing of Guarding Angle for 33/11 KV
Providing & fixing of I Bolt for Guarding
Providing & fixing of Aluminium Biding Wire for Guarding
Providing & fixing of clamp for guarding angle for 11 KV line
Providing & Fixing of Cable end termination using total double compression brass glands for 3.5x70 sq.mm. XLPE Cable
Providing & Fixing of Cable end termination using total double compression brass glands for 3.5x150 sq.mm. XLPE Cable
Providing & Fixing of Cable end termination using total double compression brass glands for 3.5x240 sq.mm. XLPE Cable
C Panel Disconeccting and dismentling of existing C panel and Supply, installation testing commisioning of factory fabricated & wired metal clad dust and vermin proof double door type outdoor application stand mounting, M.S. Channel Base incliding channel stand with bottom cable entreis The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on nonhygroscopic supports such as CMC/BMC support. panel shall be complete with suitable cable end boxes, double compression glands. panel comparment having special provision for internal locking system for stop the electricity theft The panel board shall be fabricated with gelvnized prime sheet with a minimum thickness of 1.6mm/2mm. with seven tank process powder coated. panel haveing proper space for connecting incomming and outgoing cable terminations MAKE: APC/SCHEINDER/ABB/SIEMENS/C&S & Complete with insulation of bakelite strip (08 mm/10 mm) thickness.
Earthing Complete for C Type Panels by earth rod
Providing & fixing of Lt ACB 800 Amp Nos. 250 Amp. Output MCCB and suitable covering & mounting strucuture
Providing & fixing of Lt ACB 630 Amp Nos. 250 Amp. Output MCCB and suitable covering & mounting strucuture
Providing & fixing of Foundation of RMU 3 Cubic Meter
Pipe and Pipe gel Earthing for R.M.U
Providing & fixing of Danger Board
Providing & fixing of Barbed Wire
Sagging of Guarding G.I. Wire
Providing & fixing of Stone Pad
Providing & fixing of Boot Protection For T/F Monkey Fault
Providing & fixing 16 sqmm. Alumimum thimble
Providing & Fixing of PVC Pipe 3" of diameter
Providing and Instllation of 24 Volt Battery with Charger.
Providing & Fixing of 33 KV V type Steel Cross Arm
Provoding & Fixing of 11 KV V type Steel Cross Arm
Providing & Fixing of 11 KV Pin Insulator with pin
Providing & Fixing of 33 KV V type Steel Cross Arm Holding Clamp
Providing & Fixing of 11 KV V type Steel Cross Arm Holding Clamp
Providing & Fixing of 33 KV Pin Insulator with pin
Providing & Fixing of Disc Insulator 45 KN & 70 KN (T&C/B&S) with fitting
Providing & fixing of 33 KV F Bracket
Providing & fixing of 11 KV F Bracket
Providing & fixing of Packing Piece Clamp for 33 KV/11 KV with nut & bolts
Providing & fixing of Aluminium Lug 25 sqmm.
Providing & fixing of Aluminium Lug 70 sqmm.
Providing & fixing of Aluminium Lug 150 sqmm.
Providing & fixing of Aluminium Lug 240 sqmm.
Providing & fixing of Aluminium Lug 400 sqmm.
Providing & fixing of Aluminium Lug 630 sqmm.
Providing & fixing of Aluminium Lug 1000 sqmm.
Providing & Sagging/Fixing of Al. XLPE 1x1000 Sq.mm. Cable
Installation of 11/0.4 KV, 400 KVA T/F Mobile Trolley
Providng Trolley Structure for 400 KVA T/F with vehicle tyre,rim,coupling,trolly hook,earthing, painting and related accessories with complete job
Supply of G.I. Pipe Chemical earthing electrode 3 mtr. long 80 mm inner dia along with chemical powder and 50x6 mm G.I. Strip with Nut, Bolt and Washer.
Earthing of Power Transformer (Urban) by digging of pit up to water level depth Approx. 90 feet. into the boring 1-1/4" dia GI pipe of "B" grade,conforming to the requirement of IS specification and then connecting the top of the inserted pipe and Power Transformer body earthing through M.S. strip of size 50x6mm with the help of Electric welding Lum Sum Rate. It includes the cost of all material, labour, Carrier etc. required for proper completion of work.
Installation of D.O. Fuse Set of 11 KV
Supply, install, testing and commisioning of 11 KV 630 Amps 21 KA for 3 Sec. SF6 insulated, one side extesible, outdoor duty 3 way R.M.U. manual operate, in combination of 01 nos. VCB modules (O/G) & 2 Nos. Load Breaker Switch modules (I/C), CONSITIING OF COPPER BUSBAR in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5 mm with manometer fixed on the tank. the breaker shall have mechanical ON/OFF indicator with hand Trip device and spring charging, spring relase coil, auxiliary switch of 02 NO +2NC. The HV switchgerar and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU gas tank should be internal arc tested for 21 KA for 1Second with IAC-AFL classification for gas tank. The complete RMU Should have ingress protection of minimum IP54. The RMU design should support site replaceable HT cable bushing. All the type test certified as per IEC from Third party lab to be submitted. RMU should have :- 01 Nos. micorprocessor based self powered numerical relay with over Current/earth fault & short circuit protection wiht each VCB feeder. - 3Nos. Protection CT Shall be of Burden 2.5 VA, ratio 200/1A, Class of Accuracy class 5P10 for O/C and E/F Protection for each VCB. (CT ration is indicative and may vary during detailed engineering) -1 No. Manometer for each tank-1 Nos. Voltage passage indicator for each feeder. -1 Nos. Fault Passage Indicator for each LBS Module.- Right angle boots for all the feeder Modules- Basic insulation level of complete system shall be 28KV(RMS)/75KV(Peak)- Vacuum Interrupter & RMU Should be of same make for better life cycle optimization.
Supply, install, testing and commisioning of 11 KV 630 Amps 21 KA for 3 Sec. SF6 insulated, one side extesible, outdoor duty 4 way R.M.U. manual operate, in combination of 02 nos. VCB modules (O/G) & 2 Nos. Load Breaker Switch modules (I/C), CONSITIING OF COPPER BUSBAR in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5 mm with manometer fixed on the tank. the breaker shall have mechanical ON/OFF indicator with hand Trip device and spring charging, spring relase coil, auxiliary switch of 02 NO +2NC. The HV switchgerar and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU gas tank should be internal arc tested for 21 KA for 1Second with IAC-AFL classification for gas tank. The complete RMU Should have ingress protection of minimum IP54. The RMU design should support site replaceable HT cable bushing. All the type test certified as per IEC from Third party lab to be submitted. RMU should have :- 01 Nos. micorprocessor based self powered numerical relay with over Current/earth fault & short circuit protection wiht each VCB feeder. - 3Nos. Protection CT Shall be of Burden 2.5 VA, ratio 500/1A, Class of Accuracy class 5P10 for O/C and E/F Protection for each VCB. (CT ration is indicative and may vary during detailed engineering) -1 No. Manometer for each tank-1 Nos. Voltage passage indicator for each feeder. -1 Nos. Fault Passage Indicator for each LBS Module.- Right angle boots for all the feeder Modules- Basic insulation level of complete system shall be 28KV(RMS)/75KV(Peak)- Vacuum Interrupter & RMU Should be of same make for better life cycle optimization.
Supply, install, testing and commisioning of 11 KV 630 Amps 21 KA for 3 Sec. SF6 insulated, one side extesible, outdoor duty 5 way R.M.U. manual operate, in combination of 03 nos. VCB modules (O/G) & 2 Nos. Load Breaker Switch modules (I/C), CONSITIING OF COPPER BUSBAR in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5 mm with manometer fixed on the tank. the breaker shall have mechanical ON/OFF indicator with hand Trip device and spring charging, spring relase coil, auxiliary switch of 02 NO +2NC. The HV switchgerar and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU gas tank should be internal arc tested for 21 KA for 1Second with IAC-AFL classification for gas tank. The complete RMU Should have ingress protection of minimum IP54. The RMU design should support site replaceable HT cable bushing. All the type test certified as per IEC from Third party lab to be submitted. RMU should have :- 01 Nos. micorprocessor based self powered numerical relay with over Current/earth fault & short circuit protection wiht each VCB feeder. - 3Nos. Protection CT Shall be of Burden 2.5 VA, ratio 500/1A, Class of Accuracy class 5P10 for O/C and E/F Protection for each VCB. (CT ration is indicative and may vary during detailed engineering) -1 No. Manometer for each tank-1 Nos. Voltage passage indicator for each feeder. -1 Nos. Fault Passage Indicator for each LBS Module.- Right angle boots for all the feeder Modules- Basic insulation level of complete system shall be 28KV(RMS)/75KV(Peak)- Vacuum Interrupter & RMU Should be of same make for better life cycle optimization.
Providing & Fixing of Dead end clamp With I-Hook
Providing & Fixing of Suspension Clamp With I- Hook
Providing & Fixing of piercing Clamp
Installation of LT Distribution Box
Providing & Fixing of PVC Pipe 2" of diameter
Providing & Fixing of Clamp For Distribution Box
Concreting of Pole (ST 13 Mtr./11 Mtr.) PCC Pole
Providing and Fixing/Installation of Compact Substation T/F of 400 KVA including all relevant and required accessories.
Removal of old transformer(250 KVA) with all connected accessories from existing double pole.
Removal of old transformer(100 KVA) with all connected accessories from existing double pole.
Removal of old transformer(63KVA) with all connected accessories from existing double pole.
Removal of old transformer(25KVA) with all connected accessories from existing double pole.
Construction of Plinth 6x6x4 Height from ground as per sc (as per approved GTP)
Installation of following transformer on Plinth/Double pole with all connecting accessories jumering etc. including carriage of transformers from store centre, Mathura to work site.
400 KVA Transformer on Plinth
250 KVA Transformer on Plinth
100 KVA Transformer on Double Pole
63 KVA Transformer on Double Pole
Providing and Installation of Tail less unit complete
Mash/FRP Fencing of Sub-Station with civil works (as per approved GTP)
Complete Pipe in Pipe Gel earthing of 11/0.4 KV 250/400 Distribution Transformer by digging pits 6” dia upto 3 mtr. deep including chemical filled pipe in between (pipe-in-pipe) ISI mark B Grade & connecting with G.I strip of size 50mm X 6mm with neutral/body of 11/0.4 KV distribution transformer to above pipe-in-pipe (PIP) and filling of chemical crystalline conductive mixture containing highly conductive material around the (pipe-in-pipe) up to 3 Mtr. including making of chamber at the top of the earthing. Other details are as below:- 1.Earth pipe material – mild steel, Galvanised. 2-Main Electrode diameter – 42.4mm. 3-Auxiliary Electrode pipe, Diameter – 76mm. 4-Wall Thickness of main Electrode :- 2.6mm. 5-Wall thickness of auxiliary Ist whole:- 3.2mm. 6- Length of earthing electrode (PIP):- 3 Meter.
Dismantling of damaged & used items i.e. Distribution Transformer, ST/PCC Pole, HT/LT cable, Conductor (Scrap) & other accessories at work site and carriage dismantled material from Site to Store Center, Mathura.
Proper Road Restoration Kaccha/Pakka (If required) Rates shall be acceptable, if not given above for the same work.
Bee Pee Electricals
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .