Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1.9 Cr
EMD Value
₹3.8 L
Closing Date
9 Jan 2025, 5:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Facilities Management Division, Bangalore
HINDUSTAN AERONAUTICS LIMITED Facilities Management Division, Bangalore
Renovation of LCA Hangar at ACD, HAL DC.
17934
TENDER NOTICE/NCP/42/24-25/02
Works
Contract Section Civil-FMD-Bangalore
₹0
₹3.8 L
9 Jan 2025
29 Nov 2024
29 Nov 2024
9 Jan 2025
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Year of Estblishment of Company/Business
If Other, please specify
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, etc.,
Address for correspondence:
TIN number
PAN no and Name of Holder
PF number (If any)
ESI number
Service Tax Registration No
Goods and Service Tax ID No.
SAC Code
Contact details
Registered Contractor
Pls Enter
Need to Fill Column 19
Maximum value of works excuted during the followinf 5 years. . (In Lakhs)
Pls enter Finiancial Turnover in Rupees for all the years
DETAIL OF WORK ON HAND UPTO N-Months (N-contract period) [For Bid capacity calculation] NOTE : PROVISION for 10 works are given. If more, a separate similar sheet to be made showing all the works with all details as per this FORMAT and same to Uploaded. However, 9 works details to be provided and balance work value of other works to be added and to be provided in 10th row as OTHER works.
Name of Organization with address
Balance Work On Hand
Work Schedule for completion of works with in stipulated time [Please enclose action plan / bar chart as to indicate the completion of work, within the scheduled time (contract period)]
Quantity of work Excuted during the last three years
Bank(s) details: [Copy of the cheque leaf to be uploaded]
Bank Account No.
Bank Statement for past three month
Latest Over draft Facilties with Bank enter Name of Bank, Date of Issue and Value of Over Draft
Latest Bankers Solvency Certificate from Nationalized/ scheduled Bank issued NOT before 12 months from the date of Tender Notice.
#VALUE!
Experience of having successfully completed similar works during last 7 years ending last day of previous month. [Work experience certificates / Completion certificates should be uploaded for verification]. [Latest work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of the estimated cost. [Amount put to the Tender]
You are Not Eligible
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
work done
Type of Work and Organisation name [ Incase of private works the same shall be supported with TDS certificate]
#VALUE!
Related Document to be Uploaded to eProcurement Portal
DEAILS OF TECHNICAL PERSONNEL AVAILABLE( if space provided is insufficant separate sheet to be uploaded with the same format as below)
Name of members or technical personllel avalable in the organization
DETAILS OF MACHINERY AVAILABLE
Name of Mechinery
Concrete Mixers - Type etc
Vibrators - Diesel - Electrical
Weiding equipment's
a) Rectifiers
b) Welding Generators
Erection equipment's
Cranes-
Hoists-
Lifts-
Water Lifting motor pumps
a) Diesel
b) electric
Drilling Equipment's
Compressors
Trucks
Stone crushers
Bitumen hot mixture plant
Bitume boiler
Rollers
Batching plants
Vibratory rollers
Generators
Cranes-Details
Concrete pumps
Road Pavers
Rock breakers
Transit mixers
Excavators
Weight batches
Others
Details of person holding the power of Attorney (If different from contact person)
Related Document to be Uploaded to eProcurement Portal
DECLARATION
Pls enter
Tender Document Cost and EMD details
Enclosed / Not enclosed
Enclosed
Enclosed
Average annual financial turn over during the last 3 years, ending 31st March 2024 [ should not be less than 30% of amount put to tender] and details for last 5 years to be provided to assess the bid capacity. The values provided to be supported by uploading Balance Sheet along with Profit & loss account statement. . (In Lakhs)
Specification
Disposal of surplus earth / moorum / building rubbish / malba (debriswaste) / similar unserviceable, dismantled or waste material of partitions, ceiling boards, tiles, frames, etc., by mechanical transport including loading, transporting, unloading in all lifts / loads upt 10km distance from HAL, etc., all complete as directed by Engineer-in-Charge.
Supplying, mixing and placing plain cement concrete (1:2:4) of required thickness using 20mm nominal size down graded hard stone / granite aggregate in accordance with IS 456 in posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, plinth protection, drain base, etc., including formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions, etc., but excluding the cost of centering, shuttering and finishing, etc., all complete as directed by Engineer-in-Charge.
Supplying and laying Brick work with common burnt clay machine moulded modular bricks of class designation 7.5 for walls, chambers, ducts, drains, etc., with CM (1:6) at all levels & heights including hoisting and setting in position and along with necessary formwork, curing, finishing, making or leaving holes & chases and making making horizontal and vertical grooves 10mm wide 12mm deep before plastering, etc., all complete as directed by the Engineer-in-Charge.
Supplying and laying Half Brick work with common burnt clay machine moulded modular bricks of class designation 7.5 for walls,chambers,ducts etc with CM (1:4) at all levels & heights including hoisting and setting in position and along with necessary formwork, steel rod placement between every 4th course, curing, finishing, making or leaving holes & chases and making making horizontal and vertical grooves 10mm wide 12mm deep before plastering, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing Second Class Teak wood for frames of doors, windows, hand rails, frame work for partitions, etc., cut to shape and required curvature and preparing the surfaces to receive the polishing fixed in position with hold fast lugs / with dash fasteners of required dia & length / SS Screws at all heights, with necessary moisture content test, etc., all complete as per direction of Engineer-in-Charge. (Fastners / hold fasts / SS Screws to be paid separately)
Providing and fixing panelling minimum 4.0mm thick glass panes for glazing in panelled or glazed shutters for doors, windows, ventilators and clerestory windows at all heights (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), etc., all complete as directed by Engineer-in-Charge.
Providing and fixing 18mm thick Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer, etc., all complete as directed by Engineer-in-Charge.
Supply and plastering (Pebble dash plaster) upto 15m height above ground level with a mixture of washed pebble or crushed stone 6mm to 12.50mm nominal size, dashed over and including fresh plaster in two layers under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement, etc., all complete as directed by Engineer-in-Charge.
Plastering to internal brick / block wall with 15mm thick on the rough side of single or half brick wall of cement mortor (1:6) including leveling, curing and making the level smooth and at all heights, plaster drip course / groove in plastered surface or moulding to R.C.C. projections and execute the work, etc., all complete as directed by Engineer-in-Charge.
Plastering to external brick / block wall with 18mm cement plaster in two coats under layer 12mm thick cement plaster on the rough side with cement mortor 1:5 (1 cement : 5 coarse sand) finished with a top layer 6mm thick cement plaster 1:6 (1 cement : 6 fine sand) including leveling, curing and making the level smooth and at all heights, plaster drip course / groove in plastered surface or moulding to R.C.C. projections, etc., all complete as directed by Engineer-in-Charge.
Providing and applying internal wall and ceiling painting at all heights with two coats of premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50grams / litre after applying white cement based putty of average thickness 1mm over the plastered wall surface including preparation of the surfces, with a coat of low VOC primer with emery paper to bring to smooth and even including applying additional coats wherever required to achieve even shade and colour of approved brand, etc., all complete as directed by Engineer-in-Charge.
Providing and Finishing walls with Acrylic Smooth exterior paint at all heights of required shade for New work (Two or more coat applied @ 1.67 ltr/10 Sq m over and including priming coat of exterior primer applied @ 2.20 kg/10 Sq m) including scrapping, preparationof surface, etc., all complete as directed by Engineer-in-Charge.
Providing and applying synthetic enamel paint for pipes, grills, chequered plate, etc., in Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture, filling joints, metal patti, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing double scaffolding system (cup lock type) on the exterior / internal side, up to seven story height made with 40mm dia M.S. tube 1.50m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S.clamps and M.S. staircase system in the scaffolding for working platform, etc., and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building, etc., wherever required for inspection of work at required locations with essential safety features for the workmen, etc., complete as per directions and approval of Engineer-in-Charge. The elevational area of the scaffolding shall be measured for payment purpose.
Demolishing Nominal concrete (1:3:6 / 1:4:8) work manually / by mechanical means including disposal of demolished concrete or waste material to a distance of 10km outside the HAL or to a contractor own yard outside HAL including loading and unloading lead, etc., all complete as directed by Engineer-in-Charge.
Demolishing brick work in cement mortar manually / by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 metres lead, etc., all complete as directed by Engineer-in-Charge.
Dismantling old plaster at all heights and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres, etc., all complete as directed by Engineer-in-Charge.
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling grid / tiles at all heights including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead or handing over to user department, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing mineral fibre false ceiling tiles at all heights of minimum size [595 X 595]mm of approved texture, design and pattern with 16mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.60. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance asper (BS 476 pt - 6 &7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33mm thick(galvanized @120 gsm) comprising of main T runners of [15 x 32]mm oflength 3000mm, cross T of size [15 x 32]mm of length 1200mm and secondary intermediate cross T of size [15 x 32]mm of length 600mm to form grid module of size [600 x 600]mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50mm long 8mm outer diameter M-6 dash fasteners, 6mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size [85 x 25 x 2]mm, spaced at 1200mm centre to centre along main ‘T’. The system should rest on periphery walls / partitions with the help of GI perimeter wall angle of size [24 x 24 X 3000]mm made of 0.40mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450mm centre to centre & 40mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-Charge.
Providing and injecting Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound into cracks / honey-comb area of concrete / masonry area by suitable gun / pump at required pressure including cutting of nipples after curing, etc., complete as per directions of Engineer-in Charge. (The payment shall be made on the basis of actual weight of approved grout injected.)
Supplying of ANTI BIRD NET TRANSPARENT 0.8MM/30MM and fixing the same at any height of the Hangars/shops etc. complete as directed by EIC. Note: A)Supply of Anti- bird net with following specification Material: UV stabilized made up by polymer, flame resistance(upto 50 degree Centigrade) and nonconductive stable. Border fixing with 5mm garware rope or SS Harware hooks based on site condition, Mesh size 0.8MM/30MM, Anti-corrosive. (Zip or other mean should be provided in nets for maintenance of Light fixtures etc.) B) Vendor has to provide Warranty certificate for minimum 04 years of Anti Bird Transparent Net including setup. C)Vendor has to be bring all required, Accessories, tools, equipment for installation of bird net. D)Safety Measures for height work and Personal protective equipment required for height work shall be brought by Vendor. E) Vendor may visit the site analysis before submitting the quote. F)Vendor shall obtained the Height work permit on daily basis from the safety Department before start of work.eafs and at the centre to make door airtight and dust free. G)Cleats: Cleats made of MS section shall be fixed on top guide to protect door leafs from falling down in case top wheel fails.
Supplying and fixing minimum 10mm thick multi-cell / wall polycarbonate sheet to existing MS framework profile including, suitable corrosion resistence fasteners, washers, sealant drilling, etc., all complete as directed by the Engineer-in-Charge.
Supplying and applying minimum 4mm thick epoxy flooring of approved make as detailed below: (i) Surface preparation - The surface shall be prepared by removing the existing epoxy coating / rubberized paint, grinding the concrete surface and removing any dust, laitance or any other deleterious materials to form the required anchor profile with concrete surface. The existing filling in the joints shall be removed and filled with suitable comaptible material. Any cracks in the base concrete shall be filled with epoxy repair mortar. (ii) Primer - Epoxy resin primer with a bond strength not less than 1.50 MPa shall be applied on the prepared surface. (iii) Underlay - 2mm thick self levelling epoxy underlay screed conforming to the below specifications shall be laid. Product specifications:Compressive strength @ 28 days not less than 41 Mpa Flexural strength @ 28 days not less than 10 Mpa (iv) Top coat - The surface shall be topped with 2mm thick self levelling, smooth epoxy resin topping of approved colour conforming to the below specifications. Product specifications: Compressive strength @ 28 days not less than 51 Mpa Flexural strength @ 28 days not less than 12 Mpa
Supply, fixing to/suspending from existing MS perlins/ ceiling at approx. 10-12 mtr height, including using suitable MS angle frame work with required fixing hardwares etc., as per site requirement, testing & commissioning of industrial type highbay LED lighting fixture of wattage not exceeding 150watts made out of high pressure diecast aluminium housing, diffuser made of high grade toughened glass, integral control gear, eye hook etc., (as per OEM standards). The technical parameters of lighting fixtures are as below: The luminaire should have Lumen efficacy ≥ 125lm/watt and lumen output not less than 18750lumens, PF>0.90 and Colour temprature shall be ≥5700K, THD <10%, operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures and other standard accessories complete in all respects and as directed by Engineer in-charge. The fitting shall be of Crompton model no: LHB11-150-CDL/60-HPM/ Equivalent model in other approved makes. LED used in the lighting fixtures should be one of the approved make. LM79 certification for luminares & LM80 certificate for LED shall be produced.
Supply and fixing on existing wall / ceiling, testing & commissioning of surface mounting, Batten LED light fittings (four feet) of wattage not exceeding 40W made out of aluminium extruded Housing integrated LED batten, equipped with 4kv in-built surge protection, IP20 Protection rating including control gear. The luminaire should have Lumen efficacy ≥110/120 lm/watt and lumen output not less than 4400/4800lumens with PF >0.9 and Colour temperature shall be ≥5700K, operating on single phase 240V voltage 50 Hz AC supply with voltage range 150-275V including necessary interconnections and other standard accessories complete in all respects and as directed by Engineer incharge, offered model shall of Crompton model no:CIS-305-40-57-SL-DP-NWH/equivalent model of other approved makes. LED used in the lighting fixtures should be one of the approved make. LM79 certification for luminaires & LM80 certificate for LED shall be produced.
Supply, installation, testing & commissioning of heavy duty oscillating type Air-circulator along with three speed regulator of any approved make with all connected accessories and interconnections, including power cord with 6A, 3 pin plug top and complete in all respects and as directed by Engineer-in-charge
Supply, fixing, testing & commissioning of the following factory built powder coated Double door MCB/MCCB DB of any approved make fabricated out of M.S. sheet steel enclosure & necessary cutouts for operating the MCB knobs & comprising of 200 amps tinned copper busbars & earthing bus with tapped holes including internal wiring with stranded copper PVC wires or suitable size copper strips etc. & fixing the DB in flush with wall/ on wall as per site requirement with necessary M.S. angle supports, chipping the wall and replastering to smooth finish etc., wherever required as per site condition, complete in all respects, as directed by Engineer-in-charge and comprising the following as detailed below:
12 way (4 + 36), Vertical type Double door MCCB DB
8 way (4 + 24), Vertical type Double door MCCB DB
4way (4 + 12), Horizontal type Double door MCB DB
125A 415V gr. 36KA 4P MCCB
63 amps. ratings, 4P MCB, "C" curve, 10 KA breaking capacity.
32 amps. ratings, TP MCB, "C" curve, 10 KA breaking capacity.
63 amps. ratings, TP MCB, "C" curve, 10 KA breaking capacity.
6-32 amps. ratings, SP MCB, "C" curve, 10 KA breaking capacity.
Wiring for light point / fan point / exhaust fan point/call bell point from nearest switch box with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, fan regulator, modular plate, suitable GI box/PVC box as per site requirement and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (as per detailed CPWD specifications for Group C wiring)
Wiring to single light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to Aircirculator fan point using 6A, 250V gr. flush type modular SP switch housed along with other lighting switches/separate switch box if required and 3pin 6A, 250V gr. modular type socket housed near the Aircirculator fan complete in all respects.
Power Point Wiring (6/16A Socket)
Supplying and fixing of suitable size GI Box with modular plate and cover on front on surface or in recess, including providing and fixing 2X6 pin 5/6A & 15/16A modular socket outlet and 2X15/16 A modular switch, connections etc., as required.
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
3 x 2.5 sq. mm (For lighting ckt from DB to Switch box)
3 x 4 sq. mm(For 16A power points )
Supplying and fixing of 16A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required
Supplying and fixing of 6 Module, GI box alongwith modular base & cover plate for modular switches in recess etc. as required and covering empty space with blank plate, complete in all respecte.
Supplying and fixing 30/32 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30/32A "C" curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply, Installation, Testing & commissioning of LT Panel 1&2.(TTA)
Incomer
1No - 800A, 415V gr. 50KA, 4P MDO Type ACB
Lot - 800A TP + 400A N, 415V, short circuit rated 50KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM)suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1,RS 485 Port Digital MFM/MDM of power logic PM2230 of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set of - 800/5A current transformers of suitable class and VA burden for metering.
1No 13A 415V gr TP 100KA MPCB of for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A SP MCB.
1Set- 6A, MCB for the protection of measuring instruments.
Outgoings
1No - 400A 415V gr. 36KA TPN MCCB
2Nos - 250A 415V gr. 36KA TPN MCCB
10Nos - 125A 415V gr. 25KA TPN MCCB
Design, fabrication, Supply, erection, testing & commissioning of Indoor Type LT Panel-3 (PTA)
Incoming
1No- 400A, 415V gr. 50KA, 4P MCCB.
Lot-600A, 3Phase and 300A neutral 415V, short circuit rated 36KA for 1sec, TPN Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
Earth fault relay with suitable CTs
1Set-400/5A current transformers of suitable class and VA burden for metering.
1No- 32A 415V gr TP 36KA MPCB of for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A, 230V, 10KA, SP MCB.
1Set- 6A, 230V, 10KA SP MCB for the protection of measuring instruments.
Outgoings:
1No - 250A, 415V gr. 36KA breaking capacity, TPN MCCB
6Nos - 125A, 415V gr. 25KA breaking capacity, TPN MCCB
Supply, laying, testing & commissioning of following size LT armoured power cable
3.5 CX 400 Sqmm Aluminium armoured conductor.
3.5 CX 300 Sqmm Aluminium armoured conductor.
3.5 CX 240 Sqmm Aluminium armoured conductor.
3.5 CX 185 Sqmm Aluminium armoured conductor.
3.5CX 95 Sqmm Aluminium armoured conductor
3.5 CX 70 Sqmm Aluminium armoured conductor.
3.5 CX 50 Sqmm Aluminium armoured conductor.
3.5CX 35 Sqmm Aluminium armoured conductor
3.5 CX 25 Sqmm Aluminium armoured conductor.
4C X 16 Sqmm Aluminium armoured conductor.
4C X 10 Sqmm Aluminium armoured conductor.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 CX 400 Sqmm Al Arm LT Cable End Joint
3.5 CX 300 Sqmm Al Arm LT Cable End Joint
3.5 CX 240 Sqmm Al Arm LT Cable End Joint
3.5 CX 185 Sqmm Al Arm LT Cable End Joint
3.5 CX 95 SqmmAl Arm LT Cable End Joint
3.5C X70 Sqmm Al Arm LT Cable End Joint
3.5 CX 50 Sqmm Al Arm LT Cable End Joint
3.5 CX 35 Sqmm Al Arm LT Cable End Joint
3.5CX 25 Sqmm Al Arm LT Cable End Joint
4C X 16 Sqmm Al Arm LT Cable End Joint
4C X 10 Sqmm Al Arm LT Cable End Joint
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 CX 400 Sqmm Al Arm LT Cable straight through Joint
3.5 CX 300 Sqmm Al Arm LT Cable straight through Joint
3.5 CX 240 Sqmm Al Arm LT Cable straight through Join
3.5 CX 185 Sqmm Al Arm LT Cable straight through Joint
3.5 CX 95 SqmmAl Arm LT Cable straight through Joint
3.5C X70 Sqmm Al Arm LT Cable straight through Joint
3.5 CX 50 Sqmm Al Arm LT Cable straight through Joint
3.5 CX 35 Sqmm Al Arm LT Cable straight through Joint
3.5CX 25 Sqmm Al Arm LT Cable straight through Joint
4C X 16 Sqmm Al Arm LT Cable straight through Joint
Supplying and fixing of 150 x 50 x 1.6mm size Hot dip galvanised Perforated type cable tray, steel: As per IS:2062 / 1079, Galvanising : As per IS: 2629 / 4759 including all accessories like base slotted angle , horizontal elbow, horizontal tee, horizontal cross, horizontal reducer, vertical elbow up, inside, vertical elbow down, outside, coupler plate, fasteners etc.
Design, Fabrication, Supply and fixing/grouting in wall/ceiling of suitable size MS angle iron supports/ flat/ brackets for cable tray supports, as per site requirement and painting the same with two coats of synthetic enamel paint over a coat of zinc chromite primer complete in all respects and as directed by EIC/OIC.
Earthing
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying & laying 25 mm X 5 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm)
Earth work in excavation all kinds of soil by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan). Including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, with in a lead of 50m.
Concrete cutting/Chipping/Bitumen Road the existing 1:2:4 cement concrete road /pavements / flooring / rock/stone etc., including removing debris from the work site and taking out of the division and depositing in the place as directed by EIC.
Brick Work for Cable duct
Providing p.c.c of of approved thickness in propotion of 1:4:8 cement concrete bed using 40mm graded aggregate including curing, etc., complete as directed by the Engineer-in-charge.
Construction of Brick masonary with 1:6 cement mortar including curing etc., as directed by Engineer In Charge.
Providing 1:2:4 Cement Concreter using 20mm graded aggregate including curing etc., complete as directed by the Engineer-in-charge.
Rendering 12mm thick 1:6 cement plaster on fair faces of the above Brick masonry including curing as directed by Engineer In Charge.
Removing & re-routing of existing LT cables
Up to 35 Sqmm
Above 35 sq. mm and upto 95 sq. mm
Above 95 Sq.mm and upto 185 Sq.mm
Above 185 sq. mm and upto 400 sq. mm
Disconnecting/dismantling & removal of the following items as-is-basis without any damage and handing over the same to the place as shown by Engineer-in-charge/Plant maintenance dept of ACD (not more than 1 KM) including loading, transportation, unloading etc., complete in all respects. The scope also includes disconnecting the existing cables from panel, complete in all respects and as directed by the engineer-in-charge.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
TN42.pdf
TENDER_DOCUMENT • 1.11 MB
92TB.pdf
TENDER_DOCUMENT • 4.59 MB
92PQ.pdf
TENDER_DOCUMENT • 0.20 MB
92PB.pdf
TENDER_DOCUMENT • 0.42 MB
Tenderdrawing2.pdf
TENDER_DOCUMENT • 0.03 MB
Tenderdrawing1.pdf
TENDER_DOCUMENT • 0.18 MB
Tenderdrawing3.pdf
TENDER_DOCUMENT • 0.14 MB
92Undertaking.pdf
TENDER_DOCUMENT • 0.57 MB
92Amd.pdf
TENDER_DOCUMENT • 0.20 MB
92PQF.xlsm
TENDER_DOCUMENT • 0.04 MB
92PBF.xlsm
TENDER_DOCUMENT • 0.06 MB
92Checklist.pdf
TENDER_DOCUMENT • 0.19 MB
92ECSForm.pdf
TENDER_DOCUMENT • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .