| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 00 DUDHEBHAVI KAVTHEMAHANKAL SANGLI SANGLI MAHARASHTRA 416403 | SANGLI | MAHARASHTRA | 416403 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical As per technical evaluation sheet attached |
Tender Value
₹68.0 L
EMD Value
₹1.4 L
Closing Date
19 Jun 2023, 3:00 pmClosed
PIC
IDO office,Ground Floor,Abhinandan Bhawan, IIT Indore, Simrol, MP 453554
Waterproofing of balance area of HVAC tunnel at IIT Indore
2023_IITI_757434_1
IITI/ IDO/ PR/ Bal. HVAC Tunnel/NIT/2023-24/12
Open Tender
Civil Works
Works
90 days
IIT Indore
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.4 L
20 Jul 2023
13 Jun 2023
20 Jun 2023
13 Jun 2023
19 Jun 2023
13 Jun 2023
Amount
water proofing of balance area of HVAC Tunnel at IIT Indore
Earth work in excavation by mechanical means( Hydraulic Excavator)/ manual means in foundation trenches or drains(exceeding 1.5 m in width or 10 sqm well as 10 sqm on plan) including dressing of sides and remming of bottoms,lift upto1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead as per in charge.All kind of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: water thinable cement primer inside of tunnel.
Providing and laying in position specified grade of reinforced cement concrete, including water proofing compound of approved make @200 ml per bag of cement excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : 22.2.1 Using rough Kota stone ( Note: An amount of 10% will be kept on hold against this item for a time period of 10 year. which may be release on submission of Bank guranttee or FDR for the period of 10 year.)
Clearing of site by removal of debris,from the HVAC tunnel compleate.including disposal of unserviceable material at an un objectionable place,stacking of serviceable material as per instruction tasking all necessary precautions for saftey of existing structures,service lines etc all necessary tools tackles and saftey barricades shall be arranged by the contractor.
Prepration of existing surfaces like chipping of unsound weak / loose concrete/cover of reinforcement and removal of debries to a designated location (upto full height) block to support the structure provisionally during repair work and maintaining them in positioin till required, complete all specified and directed by the Engineer-in-charge.
Injection Grouting : Providing & applying injection sockets up to 40%-50% (of the concrete thickness) deep inside at an inclination ( < 60 degree). Now inject it with the IE 6692 ( a non ionic emulsion having alkoxysilanes which induce the hydrophobicity and significantly decrese the water ingress of cementiti-ous materials ) Dilution of the 6692 is to accord the required pH and all other parameters as per the expert formulator / site incharge . Make sure the consumption 2lt per socket. It can be achieved with static head tactics and pressure pump ( 4-8 kg pressure ). Subsequently leave for 48 hours .Now create the cementitious grout slurry modified with non shrink expansive grout admixture, IE 6692, Corrosion inhibitor all with water. The dilution ratio must as per the site and hole need . The grouting slurry must be lean to stiff in each hole . Stiff slurry to be admixed with Tamseal SBR to keep log record for all sockets and finally cutting of nipples and patch it up . Ultra rapid setting mortar to plug active water to be used ( Note: An amount of 10% will be kept on hold against this item for a time period of 10 year. which may be release on submission of Bank guranttee or FDR for the period of 10 year.)
Supply & Apply Crystalline coating MS 501 2 coats @ 2 KG/ Sqm. Each coat must be in perpendicular direction to previous one at an interval of 10 hours .thoroughly saturate the surface with water before and after of each coat Including plaster is to be done on surface and to be admixed & modified per bag of cement @ Recron 3S @ 90 gms, SBR @ 1 Kg & IE6692 @ 0.5Lt. etc. complete in all respect as per direction of Engineer-In-Charge ( Note: An amount of 10% will be kept on hold against this item for a time period of 10 year. which may be release on submission of Bank guranttee or FDR for the period of 10 year.)
SFMC : Providing and laying super fluid micro concrete with PPF ( RECRON 3S) : for concrete repairs ME S 466 etc. complete in all respect as per direction of Engineer-In-Charge
Shivkrupa Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .