Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC | ₹30.8 L Quoted ₹32.4 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹33.7 L+₹1.3 L (4.16%)Rejected-Finance | ₹33.7 L+₹1.3 L (4.16%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹34.8 L+₹2.4 L (7.40%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹34.8 L+₹2.4 L (7.40%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹35.7 L+₹3.3 L (10.3%)Rejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | ₹35.7 L+₹3.3 L (10.3%) | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹35.8 L+₹3.4 L (10.4%)Rejected-Finance | ₹35.8 L+₹3.4 L (10.4%) | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 May 2025, 6:00 pmClosed
GE NAMS
GE NAMS AMRITSAR
REPAIR/ REPLACEMENT OF LT PANEL, APFC PANEL AND ALLIED WORKS OF ELECTRICAL INSTALLATIONS AT NAMS
2025_MES_705012_1
GE NAMS-11/2025-26
Open Tender
Civil Works
Item Rate
270 days
GE NAMS
CLASS D CATEGORY b(i)
8 documents required · 8 mandatory
₹500
GE NAMS
₹90,000
2 Jul 2025
22 Apr 2025
28 May 2025
22 Apr 2025
21 May 2025
7 May 2025
Amount
Dismantling & Taking down existing panel & Supply, installation, fabrication, testing and commissioning of new LT Panel board, (CPRI approved) Factory made cubical type, Outdoor type, floor mounted, factory made out of 50mm x 50mmx5mm angle iron frame and 3.15mm inner CRCA steel sheet side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated including suitable rated aluminium bus bar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of 800 amps (03 Nos 800 Amps for Phase and 01 No 400 Amps for neutral) rated aluminium bus bar complete powder coated paint with and providing necessary foundation/plateform of the feeder pillar and provision for incoming and outgoing cable, cable gland, replacement of lugs for existing cables as per site requirement and proper finshing as per existing surface complete all as specified and directed by Engr- in- Charge. Note : (i) The quoted rate shall be of all inclusive.(ii) Drawing for LT feeder piller box shall be got approved by GE before fabrication.(iii) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 40 cm below ground level and 60Cm height above ground level . Rate for Platform shall be included in the quoted rate.
Dismantling & Taking down existing panel & Supply, installation, fabrication, testing and commissioning of new LT Panel board, (CPRI approved) Factory made cubical type, Outdoor type, floor mounted, factory made out of 50mm x 50mmx5mm angle iron frame and 3.15mm inner CRCA steel sheet side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated including suitable rated aluminium bus bar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of 600 amps (03 Nos 600 Amps for Phase and 01 No 300 Amps for neutral) rated aluminium bus bar complete powder coated paint with and providing necessary foundation/plateform of the feeder pillar and provision for incoming and outgoing cable, cable gland, replacement of lugs for existing cables as per site requirement and proper finshing as per existing surface complete all as specified and directed by Engr- in- Charge. Note : (i) The quoted rate shall be of all inclusive.(ii) Drawing for LT feeder piller box shall be got approved by GE before fabrication.(iii) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 40 cm below ground level and 60Cm height above ground level . Rate for Platform shall be included in the quoted rate.
Dismantling & Taking down existing panel & Supply, installation, fabrication, testing and commissioning of new LT Panel board, (CPRI approved) Factory made cubical type, Outdoor type, floor mounted, factory made out of 50mm x 50mmx5mm angle iron frame and 3.15mm inner CRCA steel sheet side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated including suitable rated aluminium bus bar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of 500 amps (03 Nos 500 Amps for Phase and 01 No 250 Amps for neutral) rated aluminium bus bar complete powder coated paint with and providing necessary foundation/plateform of the feeder pillar and provision for incoming and outgoing cable, cable gland, replacement of lugs for existing cables as per site requirement and proper finshing as per existing surface complete all as specified and directed by Engr- in- Charge. Note : (i) The quoted rate shall be of all inclusive.(ii) Drawing for LT feeder piller box shall be got approved by GE before fabrication.(iii) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 40 cm below ground level and 60Cm height above ground level . Rate for Platform shall be included in the quoted rate.
M&L for in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 volts with stranded aluminium conductor of size 185 Sqmm 3.5 core including rate of Lugs/Thimble as per cable size laid in trenches or under road complete all as specified and as directed. (Note: Excavation, cable protection work will be measure & paid separately)
All as per serial item No 4.00 here-in- before but of size 120 Sqmm 3.5 core.
All as per serial item No 4.00 here-in- before but of size 70 Sqmm 3.5 core.
All as per serial item No 4.00 here-in- before but of size 25 Sqmm 4 core.
Supply,laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps as size of DWC pipe is 63mm O/D and 50 mm Inner dia all as specified and directed by Engr in Charge.
All as per serial item No 08.00 here-in-before but of size 76mm outer dia and 63mm inner dia.
All as per serial item No 08.00 here-in-before but of size 90mm outer dia and 76mm inner dia.
S&F in repair for heat shrinkable straight through joint for LT PVC/XLPE insulated armoured cable of size 50 Sqmm 3.5/4 core complete all as specified and as directed.
All as per serial item No 11.00 above but LT cable size of 95 to 120 Sqmm
All as per serial item No 11.00 above but LT cable size of 150 to 185 sqmm
All as per serial item No 11.00 above but LT cable size of 240 to 300 sqmm
M&L in replacement for earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth strip protect0ed by galvanized steel pipe 40 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR-2010 Part I and including necessary excavation and earth work in any type of soil, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, MS cover of thickness 5mm openable type and having suitable locking arrangement and MS frame of suitable size made of angle iron 50 x 50 x 60 mm, complete all as specified. Note: (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
S & F in replacement of MCCB four pole 100 Amps with breaking capacity 16KA , 415 Volts, fixed thermal & magnetic release including making all incoming/ outgoing connections fixed & MCCB matching with the existing slots complete all as specified and directed by Engineer in Charge.
All as per item No 16.00 but 125 Amps with breaking capacity 25 KA.
All as per item No 16.00 but 160 Amps with breaking capacity 25 KA.
S & F in replacement of MCCB four pole 200 Amps with breaking capacity 36 KA , 415 Volts, adjustable thermal & fixed magnetic release Ics=100% including making all incoming/ outgoing connections fixed & MCCB matching with the existing slots complete all as specified and directed by Engineer in Charge.
All as per item No 19.00 but 250 Amps with breaking capacity 36 KA.
All as per item No 19.00 but 315 Amps with breaking capacity 36 KA.
S & F in replacement of MCCB four pole 400 Amps with breaking capacity 35/36 KA , 415 Volts, Microprocessor release Ics=100% inbuilt adjustable overload, short circuit, ground fault including, spreader terminal including all incoming/ outgoing connections fixed & MCCB matching with the existing slots complete all as specified and directed by Engineer in Charge.
All as per item No 22.00 but 500 Amps with breaking capacity 36 KA.
All as per item No 22.00 but 600 Amps with breaking capacity 36 KA.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white , with numeric, letters in \hindi ,English and including local language and conventional skull and bones in signal red and fixed with MS Clamps , bolts and nuts of approved size for LT , 20x 15 cm complete all as specified and as directed.
Supply and laying GI steel tubing, 80mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wall for protection of Cable / GI wire / GI strip etc complete all as specified and directed.
All as per item No26.00 above but 50 mm dia.
M & L for cleaning of installation/ substation including clearing of vegitation, wild growth and trimming of grass etc around the installation compound and removing rubbish off the premises complete all as specified and as directed.
Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr in depth for foundation etc or for laying pipe lines and cables and getting out as in looses/soft soil complete all as specified.
Returning filling in including spreading leveling, watering and well ramming in layer not exe. 25 cm in soft/ loose soil, complete all as specified and directed.
Removing excavated material to a distance not exc 50m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified.
M & L for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundation of pole/Lt Panel/stay assembly etc including necessary form work all as specified and directed.
Taking out carefully manually by excavation / Pulling of cable with rope of existing LT cable of size 70 Sqmm to 240 Sqmm with loops and relaying with existing DWC pipe repair/ cutting the damages / burnt parts of cable and reconnecting into original positions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i) LT Cable Joint will be measured and paid sepearetly. (ii) Unit rate shall include for excavation and returning filling.
M&L for loose filling with aggregates of guage 40mm filling in panel sarrounding 1 to 3 mtr as per ground availability of area, cleaning the area, making level, and filling the aggregate complete all as directed by Engr-in-charge.
M & L for scraping old paint from LT panel/ feeder piller, cleaning the inner and outer surface of panel/ feeder piller box with the help of emery paper, preparing old surface for painting and applying two coats of synthetic enamel paint with spraying by air compressor (smoke Grey) over a coat of red oxide zinc chrome primer including marking name of incomming and outging connection on LT panel complete all as specified and directed. Note: The rate of synthetic enamel paint & Red oxide deemed to be included in teh item rate.
Material and labour in replacement for ACSR conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators on existing/ new cross arms, weight of conductor shall be measured straight horizontal distance between centre of two adjacent HT/LT poles and calculating weight of conductor of size length by adding 3% extra for sag jointing jumpers etc complete all as specified and directed.
M & L in replacement of cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of aluminium paint complete all as specified and directed.
M &L in replacement of pin type porcelain white, brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers & one galvanised nut 100mm height, 65mm dia for working pressure 1100 volts grade.all as specified and directed by Engr-in charge
Supply & fixing in replacement of stay assembly comprising of 7/2.50mm galvanized MS stay wire (appx 9 metre), fixed to poles with and including of FI clamps made out of FI 40x6mm and nuts bolts washers of suitable size MS stay bow 14mm dia galvanized 40cm long MS galvanised stay rod threaded with nut 16mm dia 21 Cm long with washers, MS stay plate galvanized 230x230x6mm incl necessary Excavation and PCC all as specified and directed by Engr-in charge
M & L in replacement Pre stressed concerete pole 9 mtr long of cross section of 102mm x 172mm at top and 102mm x 279 mm at bottom class 10 complying with requirement of IS-1678-1978 including painting of poles with two coats of synthetic paint in black & white strip of 30cm width upto 1.5 mtr high from coping over a coat of primer including numbering of poles as directed. Note:- Exavation and foundation will be paid and measure separetly.
M & L in replacement Steel tubular pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 9 mtr long complying with requirement of IS-1678-1978 including painting of poles with two coats of synthetic aluminium paint and black & white strip of 30cm width upto 1.5 mtr high from coping over a coat of primer including numbering of poles as directed. Note:- Exavation and foundation will be paid and measure separetly.
Pruning of tree branches of over head lines by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by Engr in Charge.
Material & labour for restrainging LT OH ACSR conductor (4 to 5 conductors per span) providing suitable proper sag all as specified and directed.
M&L for PCC ( 1:2:4) type B1 using 20mm graded stone aggregate for coping pedestal of poles. Including necessary form work fair finished to exposed surface.
Material and labour for PCC 1:3:6 type C-2 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays and poles complete all as soecified.
Supply and laying or fixing in replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed in service connections , one twin core 16 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge.
M&L for in replacement of aluminium cable lugs/thimbles long barrel type of suitable for XLPE armoured heavy duty electric power cable 1100 volts aluminium conductor of size 35 Sqmm 3.5/4 core bolt dia M14 including jointing/crimping and testing complete all as specified and as directed.
All as per serial item No 48.00 here-in- before but of size 50 Sqmm 3.5 core.
All as per serial item No 48.00 here-in- before but of size 120 Sqmm 3.5 core and bolt dia M16.
All as per serial item No 48.00 here-in- before but of size 185 Sqmm 3.5 core and bolt dia M20.
All as per serial item No 48.00 here-in- before but of size 240 Sqmm 3.5 core and bolt dia M20.
All as per serial item No 48.00 here-in- before but of size 300 Sqmm 3.5 core and bolt dia M20.
M&L for replacement of Existing Unserviceable LT feeder pillar box out door type with new supply, installation, commisioning and testing LT feeder pillar box out door type double door and single shutter front open including locking arrangement system made out of MS sheet of 3.15 mm CRCA sheet of size 0.6x0.6x0.3 mtr and double door,canopy,dust proof, bottom cable entry plate and gland for cable size150/120/95/70/50/25/16/10 sqmm 3.5 core suitable MS angle iron 50x50x6 mm with aluminium busbar size 400Amps with Incoming MCCB 250 Amp 4 pole system mounted on hygroscopic insulators bus bar including suitable nut, Bolt and Washer(16 Nos) , & including powder coated paint with and providing necessary foundation/plateform of the feeder pillar legs size 40cm below the ground and 60 cm above the ground complete from groundwith PCC 1:2:4 type B2 including provision of for incomong and outgoing cable gland, thimbling for old / new cables as per site requirement and proper finshing as per existing surface complete all as specified and directed by Engr- in- Charge. Note: Drawing for LT feeder piller box shall be got approved by GE before fabrication.
Supply & Fixing in replacement of Capacitor round super Heavy duty 440 Volt of 5 KVAR capacity complete.
Supply & Fixing in replacement of Capacitor round super Heavy duty 440 Volt of 10 KVAR capacity complete.
Supply & Fixing in replacement of Capacitor round super Heavy duty 440 Volt of 25 KVAR capacity complete.
Supply & Fixing in replacement of Capacitor duty contactor Heavy duty 440 Volt of 5 KVAR capacity complete.
Supply & Fixing in replacement of Capacitor duty contactor Heavy duty 440 Volt of 10 KVAR capacity complete.
Supply & Fixing in replacement of Capacitor duty contactor Heavy duty 440 Volt of 25 KVAR capacity complete.
Supply & Fixing in replacement of APFC Relay of 12 steps asper existing capacity 160 KVAR of APFC panel of 230 Volt complete.
Supply & Fixing in replacement of APFC contactor 9 Amp 3 pole of asper existing capacity 160 KVAR of APFC panel of 230 Volt complete.
Supply & Fixing in replacement of Push button of RED/GREEN of asper existing capacity 160 KVAR of APFC panel of 440 Volt complete.
Supply & Fixing in replacement of Indicator RYB of asper existing capacity 160 KVAR of APFC panel of 440 Volt complete.
Supply & Fixing in replacement of Digital Amp meter of asper existing capacity 160 KVAR of APFC panel of 440 Volt complete.
Supply & Fixing in replacement of Digital Volt meter of asper existing capacity 160 KVAR of APFC panel of 440 Volt complete.
Material and labour for locating the fault in Servo voltage stablizer of Capacity 400 to 500 KVA any make of 440 Volts, repair/ replacement of defected items, drying moisture from Voltage stablizer and top up of Oil complete of system and restand the elect supply complete all as specified and as directed.(FCAB Sub Stn) Note :- (i) All tools and plant including blower/ gas cylinder, spray for cleaning bus bar , spray for bus bar insulation , cleaning clothes , emergency lighting arrange in power house for repair work and other equipment/Transport/Hydra for lifting will be arranged by the contractor with no extra cost paid to contractor. (ii) One Voltage stablizer will be catered as one Job (iii) Contractor shall deposit / Procure all the material in advance to avoid any late night fault/ after market hours / non availability of material in market. The elect supply shall be restore within 8-12 hours from the time of tripping / fault in day or night in the FCAB Sub/stn, failing this a panelty of Rs 2000/- per complaint / fault will be imposed on the contractor from contractor dues. (iv) Minimun one Voltage stablizer shall be produce to contractor for restand/ repair for one visit. Contractor will not demand all stablizer repair in one visit. Visit and Repair charges of electrician and helper are included in the quoted rate. no extra charges paid to contractor.(V) Volt meter,Amp meter,DC/AC wiring kit,Control card and any type indicator replace measure and paid in quoted rate no extra charge paid to contractor. (vi) Voltage stablizer Oil replace measure and paid saperately
Supply & fixing earth strip continuity conductor on main earthing lead fixed toPanel/pole or buried in ground or at any other situation for loop earthing extra as required (beyond 7.5 M) of GI Strip 25x3 mm all as specified
Boring of holes under road, pavement, hard standing by trenchless ultra sound technology/mannual all as per site requirment complete all as specified & directed.
CHINAR ENGINEERS AND BUULDERS (BID ID -3302017)
kailu construction co (BID ID -3297111)
HARPAL ENGINEERS AND BUILDERS (BID ID -3300562)
M/S BALWINDER SINGH (BID ID -3299749)
Raman Electric Trading Co (BID ID -3296380)
ss enterprises (BID ID -3301683)
diamond electrical (BID ID -3296738)
BHARAT ENGINEERS (BID ID -3302299)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .