Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC 94 BIRHATA KALITALA PO PURBA BARDHAMAN 01 | PURBA BARDHAMAN | PURBA BARDHAMAN | WEST BENGAL | 713101 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹8.6 L+₹61,397 (7.70%)Rejected-AOC KAMAL SAGAR NEAR UIT COLLEGE BURDWAN RAJBATI PURBA BARDHAMAN WEST BENGAL 713104 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713104 | L2 | Rejected-AOC Being L2 | |
| 3 | L3₹9.0 L+₹1.1 L (13.4%)Rejected-Finance KRISHNAPUR RAJBARI PURBA BARDHAMAN PIN 713104 | PURBA BARDHAMAN | PURBA BARDHAMAN | WEST BENGAL | 713104 | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
1 Oct 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Bardhaman Electrical Division,
Purta Bhavan, 1st Floor, Purba Bardhaman
New E.I. Work at proposed single storied building adjacent to the B.Ed. department at Katwa College, Katwa in the district of Purba Barddhaman.
2020_WBPWD_297143_1
WBPWD/EEBED/NIQ-15/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
20 days
Purba Bardhaman
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
4 Nov 2020
21 Sept 2020
5 Oct 2020
21 Sept 2020
1 Oct 2020
21 Sept 2020
90 days
Amount
S&F 3 nos. 100 A. porcelain type kit kat fuses with 1 no. neutral link on wooden board incl. S&F suitable size of wooden board fixed on wall. (Havells)
S&F 415V, TPN SFU main switch of following current rating with sheet steel enclosure on angle iron frame on wall incl. S & F 3 nos. DIN type HRC fuse as per GS. (L&T / Siemens) a)125 A.
Supplying and fixing double door VTPN MCB DB with IP-42/43 protection, concealed in wall as per GS incl. necy. connection as per GS. 6 way- 1 no. 415 V 100 A. FP MCCB & 2 no. 63 A. TP MCB, 3 nos. 415 V. 40 A. TP MCBs & 3 nos. 6-32 A. SP MCBs as required (Legrand/ Siemens)
Supplying and fixing double door VTPN MCB DB with IP-42/43 protection, concealed in wall as per GS incl. necy. connection as per GS. 6 way- 1 no. 415 V 125 A. FP MCCB & 2 nos. 63 A. TP MCB, 3 nos. 415 V. 40 A. TP MCBs & 3 nos. 6-32 A. SP MCBs as required (Legrand/ Siemens)
S&F 415V. 100A. TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall incl. necy. connection as per GS. (L&T)
415 V,63 A front operated changeover ( L&T)
Supplying and fixing double door Horizontal TPN MCB DB with IP-42/43 protection, concealed in wall as per GS incl. necy. connection as per GS. (Legrand) 4 way- 1 no. 415 V 32 A. FP MCB & 12 nos. 240 V 6-32 A. SP MCBs as required (Legrand/ Siemens)
Supplying and fixing double-door SPN MCB DB with IP-42/43 protection, concealed in wall as per GS incl. necy. connection as per GS. 2+12 way Enclosure (607712) (Legrand)- 1 no. 240 V, 32 A DPMCB & 10 nos. 240 V, 6-32 A SPMCBs as required (Legrand/ Siemens/ L&T)
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish a) Average run 8 mtr
Do-do-do- on Board 5A. Modular type socket & switch as per GS.
S&F PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required as per GS. A) 20 mm dia
25 mm dia
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F 19 mm dia 3 mm thick heavy gauge polythene pipe as per GS. incl. mending good damages to building works.
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire as per GS. (synchronizing with roof/beam casting work of building construction) a)19mm dia 3mm thick Polythene Pipe
Supplying and Laying 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid Polythene pipe and making necy. connection as required i) 2x2.5 sqmm + 1x1.5 sqmm as ECC (For P.P. & computer Board point, projector)
3 x 1.5 sqmm
2x 10 sqmm + 1x 4 sqmm as ECC (from TPNBDB to SPNBDB)
2x 4 sqmm + 1x 2.5 sqmm as ECC (for Timer)
4x 10 sqmm + 2x4 sq.mm. (for TPN DB)
4x 25 sq.mm.+ 2x10 sq.mm. (for E. VTPN DB connection)
4x 25 sq.mm (from Meter to cut out & cut out Main switch and from N. VTPN DB to Change over)
4x 50 sq.mm. + 2x 10 sq.mm (from Main switch to N. VTPN DB)
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with switch - 2 set, on S&F 6 Module GI Modular type switch board with top cover plate flushed in wall incl. making necy. connections as per GS.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with switch - 2 sets on S&F 6 Module GI Modular type switch board with top cover plate flushed in wall incl. making necy. connections as per GS.
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket with switch (Brand approved by EIC) - 3 set with 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with switch - 1 set, with Indicator without plug top & 1 no. 16 A. Modular type SP MCB on S&F 16 Module GI Modular type switch board flushed in wall with top cover plate flushed in wall incl. making necy. connections as per GS.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) on S&F 2 Module GI Modular type switch board with top cover plate flushed in wall incl. making necy. connections as per GS. (Projector)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug switch (Brand approved by EIC) on S&F 1 Module GI Modular type switch board with top cover plate flushed in wall incl. making necy. connections as per GS. (Projector)
S&F GI Modular Switch Board of following sizes complete flushed in wall as per GS. A)2 module
Supply & Fixing Telephone socket (RJ11) Modular type (Brand approved by EIC) on existing GI Modular board having top cover plate and making necessary connections as required
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall as per GS. A) 240 mm x 200 mm x 65 mm
200 mm x 150 mm x 65 mm
150 mm x 100 mm x 65 mm
100 mm x 100 mm x 65 mm
300 mm x 200 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws a) 240 mm x 200 mm x 65 mm
200 mm x 150 mm x 65 mm
150 mm x 100 mm x 65 mm
100 mm x 100 mm x 65 mm
300 mm x 200 mm x 65 mm
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. a) 4 sq. mm.
Supplying of twin LED Tube light of 4' long with fitting complete with all accessories & 230V. 20 W. T-LED Tubes of PC body. (Philips /magik/CG)
Supplying of single LED Tube light of 4' long with fitting complete with all accessories & 230 V. 20W. T-LED Tube of PC Body. (Philips /Magik/CG)
Fixing only single/ twin Tube light with fitting complete with all accessories directly on wall and suitable size of MS fastener as per G.S.
Fixing only Single/ twin Tube light with fitting complete with all accessories suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp as per G.S.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification as per GS.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc as per G.S.
Supplying of ceiling fan of 1200 mm with complete accessories like blades, canopy, fork, rubber bush etc. (Orient(PSPO) /Usha stricker/ Crompton)
Fixing only ceiling fan incl. necy. connection as per G.S.
S&F 230 V. 9 W LED bulb (Philips /magik/CG-Make)
S&F outdoor type LED bulkhead light fittings on wall incl. necy. Connection as per GS. (PHILIPS - WT202W LED 6S CW PSU S2 PC)
Excavation of soil for installation of Earth Electrode and filling & ramming. - Soft soil.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long as per GS. By TATA-Medium GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar as per GS.
Connecting the equipments to earth busbar incl. S & F 10 SWG GI (Hot Dip) wire on wall/floor as per GS. A) 10 SWG
S&Delivery of the following sizes 1.1 kv grade XLPE/PVC armoured Al cable (Make: Havells/ Gloster/Nicco/equivalent) a) 2 core x 10 sqmm.
4 core x 35 sqmm.
Laying of cable of following cables on wall/surface incl. S & F MS saddles with earthing attachment,as per GS. A) 2 core x 10 sqmm. with 1 no. 10 SWG GI wire
4 core x 35 sqmm.
Laying of cable of following cables in UG trench with proper brick protection as per GS. A) 4 core x 35 sqmm.
Supplying and fixing compression type gland complete of following XLPE/PVC armoured cables as below a) 2 core x 10 sqmm.
4 core x 35 sqmm.
Finishing the end of following XLPE/PVC armoured cables as per GS incl. supplying and fixing solderless socket (Dowels make) etc. A) 2 core x 10 sqmm.
4 core x 35 sqmm.
S&F timer box consisting with 1 no. 230 V. 16 A. DP MCB, 1 no. 25 A. 3pole Power contactor, 1 no. toggle switch, 1 no. timer clock, 1 no. starter for mannual operation, 2 nos. Inditating lamps, 1 no. connector etc. incl. suitable size of interconnecting wire (power line by 4 sq.mm. wire, control circuit by 1.5 sq.mm., indicating circuit by 1.5 sq.mm.) as reqd. as per GS.
S&F 80 mm dia x 1.5 mts. long GI Pipe (ISI-Medium)pole inl S&F of 1 no G.I sole plate incl. necy. holes as required and providing cement concrete (6:3:1) muffing around the pole of dimension 600X600X600 mm on the roof of the building after chipping the roof incl. 3mm thick net cement finish and providing G.I. earth bolt after making drilled hole etc on pole incl. painting as per G.S.
S / F single arm header fabricated with 100 mm dia G.I. pipe (pole cap) of 10" height welded with 1.5 m long 40 mm dia. G.I. pipe at an angle of 10 to 15 deg incl. S / F nuts, bolts washer etc incl. painting as per G.S.
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
S&D 230 V. 45 W. LED Street light fittings (Philips/ CG - LSTS-45-CPL-1/ Magik-SPSP045C)
S&D 230 V. 90 W. LED Street light fittings (Philips/ CG/Magik -SPAI090C)
Fixing only LED street light fittings on pole incl. necy. Connection as reqd. as per GS.
Supplying & Fixing 200x150x100 mm letter type waterproof steel looping cable box on pole by clamping arrangement incl. necy. Connection & painting with anticorrosive paint as per GS
S&laying 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core 3x 1.5 sq.mm. copper wire as Loop wire. (from loop box to fittings)
Supplying & fixing 40 mm dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
Labour & machinaries charges for Shifting of 50 KVA DG set from existing position to RCC Platform as per direction of E.I.C.
Providing RCC platform for 50KVA DG installation size of 12ft width x 12ft length = 144 sq. Ft. Rectengular shaped with S& delivery of all raw material & 2 ft above ground level around thev pole base complete with 2 mm thick netly finished cement plaster all round as per direction of G.S.
Making special type brick foundation & plastering with neat cement finishing for 415V., 3 phase, 4 wire AMF panel including S & F suitable of MS angle / channel with nuts, bolts & washers etc. as per direction of the EIC.
Supply, transporation & pouring of HSD Oil. (For Testing)
S/F exhaust pipe of 80 mm. dia MS black pipe (Thickness 4 mm)-do-do- including connection with the existing silencer from DG set to nearest building (Vertical Run) with suitable high temperature painting.
S/F exhaust pipe of 65 mm. black pipe (thickness 4 mm.) -do-do- from the nearest building wall to top of the building roof. (Horizontal / Vertical run) with suitable high temperature painting.
Making insulation by 2" glass wool including netting arrangement and covered with aluminium clading as per direction of the EIC. a) 80 mm. dia exhaust pipe.
b) 65 mm dia exhaust pipe.
c) Residential type silenser pipe.
S/F special type MS angle iron bracket support made of 40x40x6 mm. MS angle with flat iron clamp with nuts, bolts & washers etc. for 80 mm. dia (Vertical Run)
S/F rain protection canopy.
S/F delivery of 200 ltrs. Capacity heavy gauge MS sheet barrel.
Earthing with 50 mm. dia GI pipe (Medium) x 3.0 mtr. Long 1 no. 25 x 5 mm. galvanized (Hot dip) sheet strip (4 mtrs. Long) 8 mm. dia x 125 mm. long GI nuts, bolts & washers etc. for neutral earth.
Earthing with 50mm. dia GI pipe (Medium) x 3.64 mm thick x 3.04 mtr. Long & 1 x 4 SWG GI (Hot dip) wire (4 mtrs. Long) with nuts, bolts & washers etc. as per GS (2 nos. for DG set & 2 nos. for AMF panel).
S/F black PVC heat shrink sleeve for covering the 25 x 6 mm. GI flat.
Supply & laying of 1.1 KV grade 12 core 2.5 sq.mm. PVC copper conductor control cable partly recessed and partly by shaddle on wall to interconnect DG set with AMF panel.
Supply & laying 1 x 25 sq. mm. single core flexible copper wire in suitable size PVC pipe (reinforced) on wall / floor from neutral earth bus to DG set neutral point including both side socketing.
S&F 9 ltr. Capacity round fire bucket with iron hook and duly filled up by sand.
S & F EI danger board. (20 cm. x 30 cm.)
S&D of the following sizes 1.1 kv grade XLPE/PVC armoured Al cable (Make: Havells/ Gloster/POLYCAB/EIC approved) a) 4 core x 50 sqmm.
Laying of following cables in UG Trench with proper brick protection as per GS. A) 4 core x 50 sqmm.
S/F compression type gland -do - do - & Finishing the end. A)4 core x 50 sqmm.
S/F earth busbar of galvanized (Hot Dip) MS flat on wall having clearance of 6 mm from wall as per GS a. 25 mm x 6 mm.
M.S. Structural work in coluam, beams etc. With simple rolled structural member as per G.S.
Asbestors corrugated ( traffored or similar aproved quality) seet 4 mm thick with (excluding the supporting frame work ) fitted & fixed as per G.S.
Galvanised plain (0.4 mm) sheet work as per GS.
Brick work 5'' up to 2 ft. Hight from the floor level at 3 side side except gate portion with net finising as per G.S.
M.S. grill , continously joints welded as per G.S. Including 2 nos. Gate with locking arrangement as per direction of E.I.C.
painting with best quality synthetic enamel pain of approved make as per G.S( 2 coat)
Rates to be quoted will be inclusive of all the taxes incl. GST. No other additional charges will be applicable in addition to the quoted rates.
DIP ELECTRICALS
DELTA BROTHERS
stage.html
html • 0.05 MB
technical_554529.pdf
PDF • 0.17 MB
techsummary_554529.pdf
PDF • 0.14 MB
finance_554529.pdf
PDF • 0.17 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_554529.pdf
PDF • 0.17 MB
Final_BEdDept_KtwColl_Progressive.pdf
PDF • 0.17 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .