REPAIR MAINTENANCE AND IMPROVEMENT TO AC PLANTS, CHILLER, CONDENSER MOTOR AND AHU ALONGWITH CONNECTED ITEMS AT FAD DAPPAR UNDER GE PROJECT DAPPAR
2022_MES_531685_1
8322/PAT/T-10/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dappar
As per cover 1
6 documents required · 6 mandatory
₹500
Yes
GE Project Dappar
₹39,800
Yes
3 Sept 2022
17 Jun 2022
27 Jul 2022
17 Jun 2022
25 Jul 2022
14 Jul 2022
17 Jun 2022 - 24 Jun 2022
Amount
Removing old unserviceable thermal insulation and supply and insulation of thermal insulation on ducts / chiller pipe line exposed to sun light using closed cell O nitrite rubber elastometric insulation of density 40-55 kg/m3 thermal conductivity of 0.037 W/mk at 20 degree celcius mean temp and MZ 7000 (without any additional vapour barrier) and with chemical treated factory laminated Woven fibre glass cloth with 200+/- 20 gsm to be applied on ducts manufactureds recommended rubber based adhesive in a blend of solvents complete all as specified and as directed.
Descaling of condensor with the help of descaling chemical and nylon brush etc from 39 TR capacity of AC plants of any make complete all as specified and as directed.
Cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of PVC finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by Engineer in Charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable PVC guard, water distibutor, PVC pipe, cooling tower motor etc of 100 TR capacity of the AC plants at different locations complete all as specified and as directed.
Servicing of AC plants of 50 TR capacity (01 No working and 01 No standing), safety checking and replacement of burnt out single core copper cable with copper lugs servicing micro processor control electric panel pnematric rewiring of controller servicing of all AHU of any CFM cleaning and washing of Filter of AHU of any size / any CFM, cleaning of cooling coil, Greasing of condensor / chiller motor pump and filling Glantory with existing size, if any rubber packing is unserviceable to change new rubber packing and cleaning and washing of syphon, cleaning and washing of cooling coil for using a chemical C-shine (Alkaline coil cleaner and brightener) and testing the unit complete all as specified and as directed.
Removing old unserviceable port Y strainer and material and labour for Y strainer 80mm size of both end flanged including supply and welding flange of size 80 mm two nos complete all as specified and as directed.
Removing old unserviceable port Y strainer and material and labour for Y strainer 65mm size of both end flanged including supply and welding flange of size 50 mm two nos complete all as specified and as directed.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve of size 80 mm with rubber packing complete all as specified and as directed.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 65 mm complete all as specified and as directed.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve of size 50 mm with rubber packing complete all as specified and as directed.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 32 mm complete all as specified and as directed.
Supply, installation, testing and commissioning of Cast Iron manual balancing valves in chilled water and condensed water plumbing and adequately supported as per specifications of size 80 mm complete all as specified and as directed.
Supply, installation, testing and commissioning of Cast Iron manual balancing valves in chilled water and condense water plumbing and adequately supported as per specifications of size 65 mm complete all as specified and as directed.
Supply, installation, testing and commissioning of Cast Iron manual balancing valves in chilled water and condense water plumbing and adequately supported as per specifications of size 50 mm complete all as specified and as directed.
Supply, fixing, testing and commissioning of 80 mm size non-return valve with dual plate of CI body SS plates vulcanized NBR seal flanged end and PN 1.6 pressure rating for chilled / hot water circulation including insulation complete all as specified and as directed.
Supply, fixing, testing and commissioning of 65 mm size non-return valve with dual plate of CI body SS plates vulcanized NBR seal flanged end and PN 1.6 pressure rating for chilled / hot water circulation including insulation complete all as specified and as directed.
Supply, fixing, testing and commissioning of 50 mm size non-return valve with dual plate of CI body SS plates vulcanized NBR seal flanged end and PN 1.6 pressure rating for chilled / hot water circulation including insulation complete all as specified and as directed.
Taking down old unserviceable water flow switch of any size, supply and fixing testing of water flow switch of suitable size including suitable wiring with control panel complete all as specified and as directed.
Taking down unserviceable / burnt scroll compressor of capacity 20 TR and M & L for scroll compressor of capacity 20 TR suitable for 60 TR (3 x 20 TR) air cooled plant of make voltas including removing of refrigerent empty cylinder R-407 flushing the system with nitrogen gas pressure testing and leak repairing vaccumising the system 700 micron charging the refrigerent R-407c complete all as specified and as directed. Note : Initial charge of refrigerent will be paid seperately.
Taking down unserviceable / burnt scroll compressor of capacity 13 TR and M & L for scroll compressor of capacity 13 TR suitable for 39 TR (3 x 13 TR) air cooled plant of make voltas including removing of refrigerent empty cylinder R-407 flushing the system with nitrogen gas pressure testing and leak repairing vaccumising the system 700 micron, charging the refrigerent R-407c complete all as specified and as directed. Note : Initial charge of refrigerent will be paid seperately.
Taking down unserviceable liquid line filter drier and material and labour for liquid line filter drier suitable for 13 TR air cooled scroll unit of make voltas including removing of refrigerent empty cylinder R-22 flushing the system with nitrogen gas pressure testing and leak repairing vaccumising the system 700 micron charging the refrigerent of R-407 / R22, complete all as specified and as directed.
Taking down unserviceable liquid line filter drier and material and labour for liquid line filter drier suitable for 20 TR air cooled scroll unit of make voltas including removing of refrigerent empty cylinder R-407c flushing the system with nitrogen gas pressure testing and leak repairing vaccumising the system 700 micron, charging the refrigerent of R-407 / R22, complete all as specified and as directed.
Supply and fix in replacement PLC based control module with digital display of Package / Central type AC unit suitable for 50 TR capacity having start / stop functions, settings option to change the seetings as per requirement complete all as specified and as directed.
Taking down old unserviceable expansion valve 20 TR compressor suitable for using 50 TR air cooled centralised AC plant double unit complete all as specified and as directed.
Taking down old unserviceable Air vent valve 15 / 20 mm and supply and fixing testing of air vent valve 15 mm complete all as specified and as directed.
S&F MCB TP 63 Amp 415 volt complete all as specified and as directed.
S&F AC contactor 63 Amp 415 volts complete all as specified and as directed.
S&F AC contactor 40 Amp 415 volts complete all as specified and as directed.
S&F Current Transformer 100/5A Single Phase, freq 50 Hz complete all as specified and as directed.
S&F MCB TP 32 Amp 415 volt complete all as specified and as directed.
S&F MCB SP 6 to 32 Amp 415 volt complete all as specified and as directed.
Providing and fixing in position the industrial type pressure gauges complete all as specified and as directed.
S&F pressure transducer 16/18 bar suitable for 50 TR air cooled central type AC plants complete all as specified and as directed.
S&F pressure transducer 30/40 bar suitable for 50 TR air cooled central type AC plants complete all as specified and as directed
S&F Chilled water sensor complete all as specified and as directed.
S&F over load relay 9 to 15 amp complete all as specified and as directed.
S&F over load relay 6 to 10 amp complete all as specified and as directed.
S&F line phase failure switch 440 v complete all as specified and as directed.
S&F high pressure switch (HP switch) upto 260 PSI NO and 190 PSI NC including removing of refrigerent empty cylinder and checking of pressure testing leak testing vaccume the system of 700 micron charging the refrigerent in the system complete all as specified and as directed.
S&F low pressure switch (LP switch) upto 25 PSI NO and 45 PSI NC including removing of refrigerent empty cylinder and checking of pressure testing leak testing vaccume the system of 700 micron charging the refrigerent in the system complete all as specified and as directed.
Disconnecting, dismantling the defective three phase induction motor 415 volts 50 Hz of any RPM for motor of capacity 15 HP and rewinding with super enamelled copper wire of best quality of existing size / gauge and weight including replacement of insulation material, varnish bearing connection plate and all other petty items required to make the motor in functional and reassembling the motor including installation commissioning and testing on full load all as specified and as directed.
All as per item No. 40.00 here-in before but of capacity 10 HP complete all as specified and as directed.
All as per item No. 40.00 here-in before but of capacity 2 HP complete all as specified and as directed.
Disconnecting, dismantling of centrifugal monoblock pump set of 7.5 HP capacity of any RPM and dismantling and replacement of defective parts such as impeller nut, glant, impeller key, gland packing water deflector bush bearings sleeve, gasket, volute stud and nuts suction and delivery flange and stud and nuts and all other petty items required to make the pumpset in functional and reassembling the pumpset including installation commissioning and testing all as specified and as directed.
All as per item No. 43.00 here-in before but of capacity 2 HP complete all as specified and as directed.
Material and labour for replacement of terminal connecting plate suitable for 7.5 HP/5 HP/3HP/2HP of monoblock pumpset complete all as specified and as directed.
Supply and fixing air cooling unit as per existing size and capacity 250 CFM of copper piping with aluminium finches complete all as specified and as directed.
Material and labour for fanbelt any size of suitable model for using of AHU motor, chiller unit, complete all as specified and as directed.
Supply and charging of Refrigerent R-407 C in sealed container of 45 Kg complete all as specified and as directed.
Supply and charging of Refrigerent R-22 in sealed container of 45 Kg complete all as specified and as directed.
Preparation of old painted surface of MS / CI pipes inlet / out let and applying a coast of synthetic enamel paint as per colour code given by the deptt complete all as specified and as directed.
Supply, laying and testing MS pipes (ERW steel) including cutting bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 80 mm as per IS 3589 (1981) thickness 6.0 mm fixed in replacement of existing unserviceable, by cutting road and footpath and making surface good as previous complete all as specified and as directed.
Supply, laying and testing MS pipes (ERW steel) including cutting bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 65 mm as per IS 3589 (1981) thickness 6.0 mm fixed in replacement of existing unserviceable, by cutting road and footpath and making surface good as previous complete all as specified and as directed.
Supply, laying and testing MS pipes (ERW steel) including cutting bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 50 mm as per IS 3589 (1981) thickness 6.0 mm fixed in replacement of existing unserviceable, by cutting road and footpath and making surface good as previous complete all as specified and as directed.
Supply, laying and testing MS pipes (ERW steel) including cutting bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 32 mm as per IS 3589 (1981) thickness 6.0 mm fixed in replacement of existing unserviceable, by cutting road and footpath and making surface good as previous complete all as specified and as directed.
S&F in replacement damper actuator suitable for 25TR AHU complete all as specified and as directed.
Providing and fixing in position the mercury-in-glass industrial type thermpmeters complete all as specified and as directed.
M&L for control wiring of hot water generator panel 55 KW / 63 KW alongwith all necessary connections complete all as specified and as directed.
Supply and fix in replacement step controller microprocessor based multistage electronic progressive staging sequencer with thermistor sensor to control the unit in stages with relay output 8A for hot water generator 55 KW / 63 KW complete all as specified and as directed.
Supply and fix in replacement control module for hot water generator 55 KW / 63 KW with water level indicator, system health status indicator, terminals for BMS-remote signal and control status complete all as specified and as directed.
Supply and fix DOL starter for 5.5 / 3.5 KW motor complete all as specified and as directed.
Removing old unserviceable PVC finches supply and laying of PVC finches of size 300mm x 200mm x 150mm complete all as specified and as directed.
Taking up condenser / evaporator from AC plant and transporting to condenser manufacture workshop and removing old unserviceable copper tube from condenser and supply, fixing testing and commissioning copper tube cell for existing size and capacity and nos of copper cell for condenser suitable for 39 TR water cooled scroll unit complete all as specified and as directed. Note : Warranty of condenser defect liability period is minimum two years after completion of contract.
Supply and installation testing and commissioning of electric rod heater of 6.12 KW for hot water generator complete all as specified and as directed.
M&L for replacement of sprinkler of 100 TR cooling tower including all necessary connections all as specified and as directed.
Taking out unserviceable servo auto manual voltage stabiliser and transporting at work shop, opening of Voltage stabiliser of capacity 200/250KVA and repair / replacement of unserviceable spare parts such as PCB/servo card, voltmeter 500v : 96mm-02Nos, 300V:72mm-03Nos, Three phase control panel - 01 No, Carbon bruses - 12 Nos, Variac coil 200 Amps, control transformer (CT) - 02 Nos, reinstalling at its original position after repair, servicing and testing complete all as specified and as directed.
M&L for rewinding of main transformer auto/manual servo voltage stabilizer of 200/250KVA capacity with super enamel copper winding wire of existing grade and size including replacement of allied insulation material of appropriate insulation class. Assebling, connecting and testing complete all as specified and as directed.
M&L for cleaning of voltage stabilizer body with cleaning agent carefully of capaciity 200/250KVA installed on platform and painting two coats of synethtic enamel paint of approved makes complete all as specified and as directed.
BANSAL ENGINEERING
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .