Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹20,960
Closing Date
18 Aug 2022, 4:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
Creation of Substation along with HT Line
2022_PDD_181361_1
ED/UDH/68 of 2022-23, dt. 28-07-2022
Open Tender
Electrical Works
Turn-key
90 days
Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer Electric Division JPDCL
₹20,960
19 Sept 2022
29 Jul 2022
20 Aug 2022
29 Jul 2022
18 Aug 2022
29 Jul 2022
29 Jul 2022 - 5 Aug 2022
Survey, Supply, Transportation, carriage, erection, testing and commissioning for laying 11KV Line on 9mtr long ST poles for Creation of 25 KVA Sub station at PP Chak Rakhwala 59.13 Km Udhampur
9 mtr long ST Pole (ST-410SP33)
GI V cross-arm with top Bracket including clamp
GI Channel X-arm including clamps and braces
30sqmm ACSR Weasel conductor
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
11KV Pin Insulator Polymeric Composite Pin Insulator 12kv, 5KN, Lighting Impulse 75 KV Positive and 80 KV Negative, Creepage Distance 320mm
11KV Disc Insulators 12KV, min failing load 45 KN, Lighting Impulse 75 KV Positive and 80 KV Negative creepage distance 320 mm with tension fittings
Earthing complete by GI Rod 20 mm 2.5 mtr long through G.I Strip 25X3 mm
Painting of 9 mtr ST poles with 2 coat of Aluminium Paint
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, carriage, erection, testing and commissioning for Creation of 25 KVA Sub station at PP Chak Rakhwala 59.13 Km Udhampur
11/0.433kV, 3-phase 25 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, Aluminium wound and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
70 mm² Single Core Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
8mtr. Long ST Pole (ST-410 SP15)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution Box for 25 KVA DTR with MCCB for incomer & SFU's for Outgoing Circuits
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors / PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
LT Prodigy Meter
Cement bottoming 1:2:4 mix as per REC standards, 0.5 Cum/Pole
Painting of ST Poles 9mtr/8mtr with 1 coat of Red Oxide
Painting of ST Poles 9 mtr/8mtr with 2 coats of Aluminium Paint
Description of Work / Item(s)
Survey, Supply, Transportation, carriage, erection, testing and commissioning for laying 11KV Line on 9mtr long ST poles for Creation of 25 KVA Sub station at PP Birmah Bridge 59.13 Km Udhampur
9 mtr long ST Pole (ST-410SP33)
GI V cross-arm with top Bracket including clamp
GI Channel X-arm including clamps and braces
30 sqmm ACSR Weasel conductor
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
11KV Pin Insulator Polymeric Composite Pin Insulator 12kv, 5KN , Lighting Impulse 75 KV Positive and 80 KV Negative, Creepage Distance 320mm
11KV Disc Insulators 12KV, min failing load 45 KN ,Lighting Impulse 75 KV Positive and 80 KV Negative creepage distance 320 mm with tension fittings
Earthing complete by GI Rod 20 mm 2.5 mtr long through G.I Strip 25X3 mm in HT Lines
Painting of 9 mtr ST poles with 2 coat of Aluminium Paint
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, carriage, erection, testing and commissioning for creation of 1 no 25 KVA PHE Sub Station at PP Birmah Bridge (59.13Km ) Udhampur
11/0.433kV, 3-phase 25KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, Aluminium wound and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV, 10 kA, LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
70 mm² Single Core Cable , 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
8 mtr. Long ST Pole (ST-410 SP15)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
LT Distribution Box with MCCB for incomer & SFU's for Outgoing Circuits ( For 25 KVA Substation)
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors / PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
LT Prodigy Meter
Cement bottoming 1:2:4 mix as per REC standards 0.5 Cum/Pole
Painting of ST Poles 9mtr/8mtr with 1 coat of Red Oxide
Painting of ST Poles 9 mtr/8mtr with 2 coats of Aluminium Paint
M/S RATHER CONSTRUCTIONS AND TRADERS
M/s delta generation
M/S LUMEN ENGINEERS
M/S RATHER CONSTRUCTIONS AND TRADERS
M/s delta generation
M/S LUMEN ENGINEERS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .