Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹43.8 L+₹9.2 L (26.7%)Rejected-Finance H NO 21666 POWER HOUSE ROAD STREET NO 9 BATHINDA PB 151001 | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹46.8 L+₹12.3 L (35.5%)Rejected-Finance 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹47.4 L+₹12.9 L (37.2%)Rejected-Finance | L4 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | somyaenterprises L1 | G M BUILDERS 36 L4 | SUNRISE ENGINEERS AND CONTRACTOR L2 | J.K & Company L3 |
|---|---|---|---|---|---|---|---|
| 1.00Taking out of the unseviceable / repairable parts from the engine with due care, and supply / fixing of the following new and original spare parts including carrying out all related minor and periodical maintenance and ovehauling works as per site requirement suitable for 100 KVA capacity DG set, all as specified and directed :- | |||||||
| 1.01 | Pre filter Cat Part No: 48.117.04.0.00 | 3 | EACH | 550 ₹1,650 Lowest | 2,200 ₹6,600 | 2,000 ₹6,000 | 2,000 ₹6,000 |
| 1.02 | Micro Filter Cat Part No: 48.117.05.0.00 | 3 | EACH | 600 ₹1,800 Lowest | 2,200 ₹6,600 | 2,000 ₹6,000 | 2,200 ₹6,600 |
| 1.03 | L.O. Filter element. Cat Part No: 06.436.01.0.00 | 3 | EACH | 650 ₹1,950 Lowest | 2,200 ₹6,600 | 2,000 ₹6,000 | 2,000 ₹6,000 |
| 1.04 | Hose Radiator to pump inlet Cat Part No: 6H.057.02.0.00 | 3 | EACH | 1,100 ₹3,300 | 1,500 ₹4,500 | 1,000 ₹3,000 Lowest | 1,500 ₹4,500 |
| 1.05 | Hose thermostat to radiator Cat Part No: 6H.057.01.0.00 | 3 | EACH | 500 ₹1,500 Lowest | 1,500 ₹4,500 | 1,000 ₹3,000 | 1,500 ₹4,500 |
| 1.06 | Hose water pump to radiator Cat Part No: 4H.073.02.0.00 | 3 | EACH | 1,250 ₹3,750 Lowest | 1,500 ₹4,500 | 2,000 ₹6,000 | 1,300 ₹3,900 |
| 1.07 | Air cleaner element Cat Part No: F6.504.08.0.00 | 3 | EACH | 450 ₹1,350 Lowest | 1,800 ₹5,400 | 1,500 ₹4,500 | 1,200 ₹3,600 |
| 1.08 | V-belt Cat Part No: 4H.069.01.0.00 | 3 | EACH | 850 ₹2,550 | 800 ₹2,400 | 500 ₹1,500 Lowest | 700 ₹2,100 |
| 1.09 | V-belt Cat Part No: 47.305.01.0.00 | 3 | EACH | 850 ₹2,550 | 800 ₹2,400 | 500 ₹1,500 Lowest | 750 ₹2,250 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
30 Jul 2025, 6:00 pmClosed
Maj Ashish Kanyan
GE Kapurthala
Repairs/maint of 0.4 MLD STP, DG Set, installation and allied works at Mil Stn Kapurthala under GE Kapurthala
2025_MES_717995_1
8067/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Area under GE Kapurthala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Kapurthala
₹98,000
6 Oct 2025
2 Jul 2025
1 Aug 2025
2 Jul 2025
30 Jul 2025
16 Jul 2025
Amount
Taking out of the unseviceable / repairable parts from the engine with due care, and supply / fixing of the following new and original spare parts including carrying out all related minor and periodical maintenance and ovehauling works as per site requirement suitable for 100 KVA capacity DG set, all as specified and directed :-
Pre filter Cat Part No: 48.117.04.0.00
Micro Filter Cat Part No: 48.117.05.0.00
L.O. Filter element. Cat Part No: 06.436.01.0.00
Hose Radiator to pump inlet Cat Part No: 6H.057.02.0.00
Hose thermostat to radiator Cat Part No: 6H.057.01.0.00
Hose water pump to radiator Cat Part No: 4H.073.02.0.00
Air cleaner element Cat Part No: F6.504.08.0.00
V-belt Cat Part No: 4H.069.01.0.00
V-belt Cat Part No: 47.305.01.0.00
Stop solonoid Cat No- 4H1503000
K-Cool Super 25 Ltr ( 8202035125)
Cylinder head gasket Cat No-6H00706000
Taking out of the unseviceable / repairable parts from the engine 40 KVA and supply / fixing of the following new spare parts including carrying out all related minor and periodical maintenance and ovehauling works as per site requirement suitable for kirloskar oil engine complete all as specified and directed:-
Air filter (0458603000)
Lub Oil filter ( 0643601000)
Pre filter ( 4811704000)
Micro filter ( 4811705000)
Hose ( water Pump to radiator) ( 4 H 07302000)
V Belt ( 4 H 06901000)
Fuel pipe(0665410000)
Fuel leak off pipe (4H 24710000)
Fuel Pipe ( 4H 03105000)
Fuel Pipe (4H 0310400)
Set of joints ( 4H 08710000)
Water temperature switch (4626001000)
Set of O Rings ( 4H 08720000)
Set of copper washer (4H08730000)
OFF/ON Start switch ( 49135030000)
Sensor unit for temp gauge (46085020000)
Taking out of unserviceable water pump assy from 100 KVA DG set including S&F new water pump assy to its original position complete all as directed. (Cat Part No -04H 05220000)
Taking out of unserviceable water pump assy from 62.5 KVA DG set including S&F new water pump assy to its original position complete all as directed. (Cat Part No -04H 05220001)
Taking out of unserviceable water pump assy from 40 KVA DG set including S&F new water pump assy to its original position complete all as directed. (Cat Part No -04H 05220002)
Taking out of unserviceable water pump assy from 30 KVA DG set including S&F new water pump assy to its original position complete all as directed.
Servicing the silancer assembly, remove the complte silencer assembly from DG set by removing nuts bolts complte, including opening the wall of silancer outlet remove the old aspectose rope on silencer complte, remove the blockage complte, reassemble the silencer with DG set with new gasket, nut, bolts & washers, gaswelding on damaged portion on silencer pipe complete DG set 100 KVA
Servicing the silancer assembly, remove the complte silencer assembly from DG set by removing nuts bolts complte, including opening the wall of silancer outlet remove the old aspectose rope on silencer complte, remove the blockage complte, reassemble the silencer with DG set with new gasket, nut, bolts & washers, gaswelding on damaged portion on silencer pipe complete DG set 62.5 KVA .
Servicing the silancer assembly, remove the complte silencer assembly from DG set by removing nuts bolts complte, including opening the wall of silancer outlet remove the old aspectose rope on silencer complte, remove the blockage complte, reassemble the silencer with DG set with new gasket, nut, bolts & washers, gaswelding on damaged portion on silencer pipe complete DG set up to 40 KVA .
Taking out of unserviceable Dynamo Assy from 100 KVA DG Set including S&F new Dynamo assy to its original position complete all as directed .
Taking out of unserviceable Dynamo Assy from 62.5 KVA DG Set including S&F new Dynamo assy to its original position complete all as directed .
Taking out of unserviceable Dynamo Assy from 40 KVA DG Set including S&F new Dynamo assy to its original position complete all as directed .
Taking down of unserviceable Radiator from the 100 KVA DG Set including connected hose pipe etc and cleaning thoroughly all the tubes and fins etc and carrying out copper brazzing to stop the leakage of the cooling tubes and refixing of the same.
Taking down of unserviceable Radiator from the 62.5 KVA DG Set including connected hose pipe etc and cleaning thoroughly all the tubes and fins etc and carrying out copper brazzing to stop the leakage of the cooling tubes and refixing of the same.
Taking down of unserviceable Radiator from the 40 KVA DG Set including connected hose pipe etc and cleaning thoroughly all the tubes and fins etc and carrying out copper brazzing to stop the leakage of the cooling tubes and refixing of the same.
Supply and fill the Lub oil grade 10 w 15 for DG set of 100KVA-3nos,62.5KVA-1 no, 40 KVA-4 nos, 30 KVA - 2 Nos all as per the requirement, Make : Bharat petrolium/Indial oil complete all as specified and as directed.
S&F Diode (Positive and Negative) suitable for Rotary rectifier 30 KVA Kirloskar alternator including taking out of unserviceable one and all as directed.
S&F Diode (Positive and Negative) suitable for Rotary rectifier 100 KVA Kirloskar alternator including taking out of unserviceable one and all as directed.
Dismantling of FIP, injector nozzles includings connected accessories from 40 KVA Kirloskar DG sets and M&L for carrying out overhauling, calibrationfrom authorised service centre, replacement of damaged spares if any and refixing complete and all as directed.
Dismantling of FIP, injector nozzles includings connected accessories from 62.5 KVA Kirloskar DG sets and M&L for carrying out overhauling, calibration from authorised service centre, replacement of damaged spares if any and refixing complete and all as directed.
S&F digital/panel board type battery charger 230V AC input 12V DC out put fixed in DG panel board including all necessary cable connections
S&F Digital type Genset control unit complete all as specified and directed.
S&F MCCB Three pole 25KA63A, A frame Adjustable Thermal & Fixed Magnetic setting cat no IHLAST0063 of make Havells or equilent fixed to LT panel board with necessary arrangement complete all as specified and as directed.
S&F MCCB four pole 25KA 100A, A frame Adjustable Thermal & Fixed Magnetic setting cat no IHLAST00100 of make Havells or equilent fixed to LT panel board with necessary arrangement complete all as specified andc as directed.
M&L wiring for circuit/submain wiring alongwith earthwire with the following sizes of 4x4sqmm 2x2.5sqmm FR PVC insulated copper conductor,single core cable in surfacessed as required in PVC casing caping at Bhaga pump house complete all as specified andc as directed.
M&L Sheet metal enclosure for DBs when MCBs to be used single pole and neutral 4 way 200 Amps rated busbar 240 volt double door complete all as specified andc as directed.
M&L Isolator TPN 415 volt 32Amp complete all as specified andc as directed.
M&L PVC rectangular block for mounting, switches, sockets, etc with 3mm thick plastic laminated sheet cover size 250x200x50mm deep complete all as specified andc as directed.
Taking out of unservicable self starter 12 volt and connected unserviceable portion of electric wiring and carring out repairs and overhauling of the self starter up to 30 KVA gen set and replacement of armature, carbon brush, bearing, bendix penion, solenoid complete all as specified and as directed.
Taking out of unservicable self starter 12 volt and connected unserviceable portion of electric wiring and carring out repairs and overhauling of the self starter for 100 KVA gen set and replacement of armature, carbon brush, bearing, bendix penion, solenoid complete all as specified andc as directed.
Dismantalling of existing worn out Lead acid Battery from DG set and S&F 12 VOLTS PULSE Sealed maintenance free Generator Starting System (Part no. AX 1006139) Make : CUMMINS complete all as specified andc as directed.
Dismantalling of worn out battery clamp and battery connecting wire made of copper 35 sqmm ,1.5 mtr long and replacement of battery clamp heavy duty in one side and copper lugs on other side suitable sizes fixed complete all as specified and as directed.
S&F machinery description board made out of 4mm thick acrylic sheet and vynil sheet pasted on it with computer cut letters in white colour on blue back ground mounted with the help of stainless steel fastners 6-8 nos lettering shall be in english or alfa numeric of suitable size and fonts not more than 100 letters. Display board size will various as per requirement not more than 4 sqmtr in size all as directed
S&F for angle iron frame made of suitable size equal angle iron and MS flat of size 25mmx4mm for mounting of startors/SF units duly painted with one coat of red oxide and two coat of synthetic enamel black colour and including make hole all new nut,bolts and washers for fixing of startor/main switch etc and grouting at site/pump house including PCC all as directed.
Attending of urgent complaints in any breakdown of standby Diesel engine with centrifugal pump at Turial location, whenever required, rectify the fault and restore the standby supply within 08 hours after receipt of the complaint. Note: (i). The cost of replaced spare parts will be paid and measured seperately. (ii). If complaint is not attended by the contractor within three hours the penality of Rs.300/- to be impossed to him. (iii) The cost of transportation (to and fro) for all kind of necessary equipment/T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor in this effect. (iv) Complaints shall be lodged by telephonic, so contractor give the telephone number which will be receive the complaint round the clock. (v) Normal routine work shall be not included in urgent complaint.
Supply only lubricating oil filter suitable for DG Set of any type/make and capacity up to 40 KVA, complete all as directed. Make - Bosch / Purolator / Lucas or equivalent
Supply only fuel oil filter suitable for DG Set of any type/make and capacity up to 40 KVA, complete all as directed. Make - Bosch / Purolator / Lucas or equivalent
S&F in replacement of fan belts 63 , V-type suitable for DG Set of any type/make and capacity up to 40 KVA, complete all as directed. Make - Bosch / Purolator or equivalent
S&F in replacement of fan belts 72, V-type suitable for DG Set of any type/make and capacity up to 40 KVA, complete all as directed. Make - Bosch / Purolator or equivalent
S&F in replacement of battery terminals made of brass, suitable for battery of any type/make and capacity, complete all as directed. Make - Bosch / Purolator or equivalent
Supply only piston for DG Set suitable up to 40 KVA capacity, complete all as directed. Make: Kirloskar/ Champion/ Ghelani or equivalent
Supply only piston ring for DG Set suitable up to 40 KVA capacity, complete all as directed. Make: Kirloskar/ Champion/ Ghelani
Supply only connecting bearing for DG Set suitable up to 40 KVA capacity, complete all as directed. Make: Kirloskar/ Champion/ Ghelani
Supply only crank bush brass for DG Set suitable up to 40 KVA capacity, complete all as directed. Make: Kirloskar/ Champion/ Ghelani
Supply only main bearing for DG Set suitable up to 40 KVA capacity, complete all as directed. Make: Make: Kirloskar/ Champion/ Ghelani
S&F in replaement of center bearing for DG Set suitable up to 40 KVA capacity, complete all as directed. Make: Kirloskar/ Champion/ Ghelani
S&F in replacement of nozzle for DG Set suitable up to 40 KVA capacity, complete all as directed. Make: Kirloskar/ Champion/ Ghelani
S&F in replacement of Planjar Spring for DG Set suitableup to 40 KVA capacity, complete all as directed. Make: Make: Kirloskar/ Champion/ Ghelani
S&F in replacement of head gasket for DG Set suitable up to 40 KVA capacity, complete all as directed. Make: Make: Kirloskar/ Champion/ Ghelani
S&F in replacement of oil seal complete for DG Set suitable up to 40 KVA capacity, complete all as directed. Make: Make: Kirloskar/ Champion/ Ghelani
S&F in replacement of gasket unit complete for DG Set suitable up to 40 KVA capacity, complete all as directed. Make: Kirloskar/ Champion/ Ghelani
Taking out of unserviceable Dynamo Assy up to 40 KVA DG Set including S&F new Dynamo assy to its original position complete all as directed .
S&F in replacement, Battery 12volts, 75AH. Cat pt No. Power safe plus Ep 75-12 of Exide or equivalent
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for taking out and laying CI/GI pipe complete all as specified and directed.
Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer complete all as specified and directed.
Removal of surplus spoil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable complete all as specified and directed. Note : For payment purposes 18cm thickness shall be considered.
M&L for brick protection using old size sub class ‘B’ bricks, laid flat, dry adjacent to each other laid length wise perpendicular to the axis of cable complete all as specified and directed.
Taking down GI pipe 20 mm bore medium grade and fitting and S&F GI tubing medium grade 20 mm bore in any length with all fitting laid in trench and connecting up with water supply main complete all as specified and directed (Excavation and earthwork shall be measured and paid for separetely under approprite item)
All as per item ser No 59 above here in before but 25 mm bore complete all as specified and as directed.
All as per item ser No 59 above here in before but 40 mm bore complete all as specified and as directed.
All as per item ser No 59 above here in before but 50 mm bore complete all as specified and as directed.
S&F in replacment of gun metal globe or gate valve with iron wheel head screwed both ends suitable for galvanised pipe 20 mm bore complete all as specified.
All as per item ser No 63 above here in before but 25 mm bore complete all as specified and as directed.
All as per item ser No 63 above here in before but 40 mm bore complete all as specified and as directed.
All as per item ser No 63 above here in before but 50 mm bore complete all as specified and as directed.
Taking down old unserviceable GI/CI pipe 80 mm bore and supply, laying, jointing and testing new Ductile iron pipe (K=7) 80 mm bore centrifugally cast class LA confirming to IS - 1536 spigot and socketed ends in any length laid in trenches complete all as specified and directed. (Note : excavation, earth work, CI fitting and new run lead joint shall be measured and paid for separetely under appropriate item of Sch 'A')
All as per item No 67 above here in before but DI (K-7)100 mm bore complete all as specified and as directed.
All as per item No 67 above here in before but DI (K-7) 150 mm bore complete all as specified and as directed.
Taking out old insv fab media any type and replacing it with MBBR Fab Media 18 mm (dia) x 12 mm cylindrical / circular shaped having external fins, non toxic, virgin plastic, black color.MBBR Fab Media, height 12 mm, dia 18 mm, cylindrical/spherical shaped, with external fins, non toxic, virgin plastic, black in colour complete all as specified and directed.
Taking out old unserviceable tube settler media and replacing it with the media having the following specifications specifications.Media straight height / media height at 55 degrees. : 1150 mm / 1000 mm MOC of Media : UV Stabilized Virgin PVC Base, Shape of Media : Chevron / Square tube, Qty of media in each tank : 6.25 m3, Tube Fitting : Tongue & GrooveThickness : 1.0 mm (+ 0.1 mm) Colour : Black complete all as specified and directed .
Taking down old unserviceable UPVC Pipe and replacing it with UPVC Pipe 50 mm Schedule '80' Pipe complete all as specified and as directed.
Taking down old unserviceable UPVC Pipe and replacing it with UPVC Pipe 65 mm Schedule '80' complete all as specified and as directed.
Taking down old unserviceable UPVC Pipe and replacing it with UPVC Pipe 25 mm Schedule '80' complete all as specified and as directed.
Taking down old unserviceable UPVC Pipe and replacing it with UPVC Pipe 200 mm Schedule '80' complete all as specified and as directed.
Taking out old unserviceable UPVC elbow 50 mm and replacing it with UPVC elbow of dia 50 mm for upvc pipes complete all as specified and as directed.
Taking out old unserviceable UPVC elbow 65 mm and replacing it with UPVC elbow of dia 65 mm for upvc pipes complete all as specified and as directed.
Taking out old unserviceable UPVC bend and replacing it with UPVC new Bend of 200 mm for upvc pipes complete all as specified and as directed.
Taking out old unserviceable flanges and replacing it with new Flange of dia 65 mm for upvc pipes complete all as specified and as directed.
Taking out old unserviceable flanges and replacing it with new Flange of dia 200 mm for upvc pipes complete all as specified and as directed.
Taking out old unserviceable Tee and replacing it with new Tee of dia 65 mm for upvc pipes complete all as specified and as directed.
Taking out old unserviceable Tee a for upvc pipesnd replacing it with new Tee of dia 200 mm complete all as specified and as directed.
Taking out old unserviceable End Cap and replacing it with new End Cap of Dia 65 mm for upvc pipes complete all as specified and as directed.
Taking out old unserviceable End Cap and replacing it with new End Cap of Dia 200 mm for upvc pipes complete all as specified and as directed.
Taking down Air Blowers and S&F new one complete all as specified and as directed.
S&F of battery 12 volts 180AH Make Excide/Lumminus complete all as specified and as directed.
M&L for steel structure for foundation of Tube Settler made out of MS Steel angle iron , Bar , Square Bar, Channels etc all as required at site duly painted with anti corrosive paint all as directed.
S&F PVC insulated submersible cable 03 core 1100 Volt AC Supply stranded copper conductor of size 10 sqmm in replacement of old U/S cable Make : Rallison / Plaza/Fenolax.
M&L for cleaning and surface dressing of plant area by cutting grass and excavation upto 30 cm depth, spraying chemical, laying polythene in excavated area and filling complete with provn of 63mm graded stone aggregate upto height 40cm all as specified and directed.
M&L for cleaning of semi under ground raw sewage sump of capacity 30000 galan collection chamber of 5.05 m depth & dia 6 m of the tank from ground level in RCC M-30 construction. removing of silt and sludgeto a distance not exceeding 50 Mtr from GL etc deposited inside the tank cleaniang entire internal surface of tank with bleaching powder and flushing with water complete ensuring removal of heavy sludge deposited at the bottom all as specified and marking Date of cleaning with enamelled paint as directed.
M&L for cleaning of fine bar steel screen chamber of 25 mm x 25 mm thick flat 6 mm of the tank from ground level in RCC M-30 construction. removing of silt and sludgeto a distance not exceeding 50 Mtr from GL etc deposited inside the tank cleaniang entire internal surface of tank with bleaching powder and flushing with water complete all as specified and marking Date of cleaning with enamelled paint as directed.
M&L for cleaning of Screen chamber in mild steel epoxy painted construction in RCC M-30 of size 2.00 m X0.3 m X0.45 m and sludgeto a distance not exceeding 50 Mtr from GL etc deposited inside the tank cleaniang entire internal surface of tank with bleaching powder and flushing with water complete all as specified and marking Date of cleaning with enamelled paint as directed.
M&L for cleaning of stilling chamber in RCC M-30 construcion size 1.30 m x1.30 m x1.30 m depth removing of silt and sludgeto a distance not exceeding 50 Mtr from GL etc deposited inside the tank cleaniang entire internal surface of tank with bleaching powder and flushing with water complete all as specified and marking Date of cleaning with enamelled paint as directed.
M&L for cleaning of Equilization tank (EQT) in RCC M-30 construction with rung ladder of size L 6.00 m x W 5.00 m x D 4.5 m (including 0.2 m free board ) and sludgeto a distance not exceeding 50 Mtr from GL etc deposited inside the tank cleaniang entire internal surface of tank with bleaching powder and flushing with water complete all as specified and marking Date of cleaning with enamelled paint as directed.
M&L for cleaning of MBBR reactor chamber in RCC M-30 construction with rung ladder of size L 6.00 m x W 5.00 m x D 4.5 m (including 0.2 m free board ) and sludgeto a distance not exceeding 50 Mtr from GL etc deposited inside the tank cleaniang entire internal surface of tank with bleaching powder and flushing with water complete all as specified and marking Date of cleaning with enamelled paint as directed.
M&L for cleaning of Oil & greese trap/ grit chamber in RCC M-30 Construction of size 4.00 m x1.00m x 0.75m (depth including free board) and sludgeto a distance not exceeding 50 Mtr from GL etc deposited inside the tank cleaniang entire internal surface of tank with bleaching powder and flushing with water complete all as specified and marking Date of cleaning with enamelled paint as directed.
M&L for cleaning of Collection supm chambers of sewage pump houses Construction of sizes and sludgeto a distance not exceeding 50 Mtr from GL etc deposited inside the tank cleaniang entire internal surface of tank with bleaching powder and flushing with water complete all as specified and marking Date of cleaning with enamelled paint as directed.
M&L for suitable Coagulants/ Flocculants (like Aluminium Sulfate, Ferric Chloride, Ferrous Sulphate, Polyacrylamide based polymers and Polyaluminium Chloride etc ) as per sewage requirements in powder form and required proportion at suitable intervals for TSS and Phosphorus Removal.
M&L for suitable PH adjustment Chemicals (eg - Lime/Sodium Hydroxide/ Sodium Bisulphate HCl etc) as per sewage reaquirements and required proportion at suitable intervals for proper PH Balance.
M&L for suitable COD control Substances and Disinfectants for pathogen removal.
M&L for disconnecting electric connection and pipe connection and taking out for non clog sewage pump motor capacity 10 HP including replacement of ball bearings and alignment of motor starter stator.. submersible pump & motor of capacity 10 HP from bore well and taking to workshop for repair and removal of burnt winding wire from motor and rewinding with new PVC insulated copper winding wire for submersible motor of same guage and weight to existing including replacement of , Motor bush, thrust plate coupling complete with key and alignment of motor stater's slote reassembnling the motor with pump and lowering it into bore well making it functional and testing complete all as specified.
All as per item 101 above here in before but capacity 7.5 HP complete all as specified and as directed.
All as per item 101 above here in before but capacity 5.0 HP complete all as specified and as directed.
All as per item 101 above here in before but capacity 3.0 HP complete all as specified and as directed.
All as per item 101 above here in before but capacity 5 HP monoblock pump set complete all as specified and as directed.
S&F phase sequancer corrector with phase loss corrector system working on 415 Volt, 50 Hz, On/Off coil (switch) current capacity 18A, working voltage 12/24 Volt, Cut of voltage (Low) 330-370 (Adjustable), cut of voltage (High) 440-540 Voltage (Adjustable), Phase reversal System, Single phasing protection system, Time delay to start system 150 sec and Off switching time (two stop the system) for 10 HP submersible pump etc complete all as specified and directed. Make :- VOLT-ON/Supreme Power Tac/Runcon
All as per item No 106 here in before but current Capacity 32A, 7.50 HP complete all as specified and as directed.
All as per item No 106 here in before but current Capacity 5 HP complete all as specified and as directed.
All as per item No 106 here in before but cuurent Capacity 3 HP complete all as specified and as directed.
Taking down old unsv bleching dozing pump along with all accessories and Supply and install connecing. Testing and commissioning of High Pressuure single Head adjustable "DECLIBAC" Dosing system Model No VST 1005 and VST 1006 of the following specification. Adjustble High Pressure 5 Kg/Sq. cm. power input 230V, 50 Hz, 40 SPM 1/30 fractional Horsepower, Max output 10 Ltr with mandatory accessories like lead Tubing, connecting ferrules, check valves, etc (A) Preparation tank Model No VST 1005 of net capacity 100 Ltr, FRP dosing tank dia 650 x net Height 375 + conical 300. Gross height with stand 1000 mm consisting of : (i) Water inlet line (ii) Outlet with stainer (iii) Drain (iv) overflow (v) conical bottom for sludge depositing (vi) Pot hole with cover (vii) level gauge (viii) Agitator 120 watt 900 RPM single phase flange mounted motor with plastic shaft and impeller. (B) Service Tank Model No VST 1006 dia 480 x height 575 net capacity 100 Ltr consisting of (i) water inlet line (ii) Dosing pump inlet arrangement (iii) Drain (iv) Overflow (v) Level Gauge (vi) inspection port (vii) Agitator 120 watt 900 RPM Single Phase flange mounted moto with plastic shaft and impeller (ix) provision of mounting Pump on Lid/wall Make : DECLIBAC.
Attending of urgent complaints in any stoppage/ malfunctioning/Deposition of sludge/ water quality failure/ inlet or outlet pipe leakage or brokerage/ Failure of Air Blowers of 0.4 MLD STP at site location, whenever required, rectify the fault and restore the functioning within 12 hours after receipt of the complaint. Note: (i). The cost of replaced items will be paid and measured seperately. (ii). If complaint is not attended by the contractor within 8 hours the penality of Rs.300/- to be impossed to him. (iii) The cost of transportation (to and fro) for all kind of necessary equipment/T&P shall be arranged/brought by contractor to complete the job at site and no extra cost shall be paid to the contractor in this effect. (iv) Complaints shall be lodged by telephonic so contractor give the telephone number which will be receive the complaint round the clock. (v) Normal routine work shall be not included in urgent complaint.
Supply only bettery 12 volts 180AH Make Exide/Lumminus or equivalent complete all as specified and as directed.
Supply only on load change over rotery type 4 pole 415 volt 200 Amp Make :Standard/L&T/Indoasian or equivalent complete all as specified and as directed.
Supply only orthotolidine reagenet for chlorine test in 500 ml bottle of make - glaxo / SDS / Ran baxy or equivalent complete all as specified and as directed.
Supply only Calcium based granuler disinfect suitable for treatment drinking water in 45 kg plastic drum complete all as specified and directed Make: Rayal Seema/Aquafit/Daclibac or equivalent complete all as specified and as directed.
Material labour and services for taking sample of sewage water in sterlised bottles from various borewells for Analysis of water for the following parameters and obtaining sample test report from Govt Recognized Laboratories: Note : - 1. A certificate of approval / certification of Lab by Goivt Of India / State Govt shall be submitted by the contractor to the deptt. 2. Sample shall be submitted to the Labortory within 24 Hrs of collection of sample
Supply of Chlorine test kit with coloured ample complete with all testing fitments and OT solution in Rexene finish Box Make - RMCO or equivalent complete all as specified and as directed.
Repair to existing valve pits of internal dimensions 1.5 M x 1.5 M x 2 M making good disturbed/dismantled brick work in cement mortar (1:4) plastering surfaces in CM 1:6, 15mm thick and PCC coping in cement concrete 1:2:4 type B-1 and providing MS cover in replacement made out of MS sheet 3 mm thick duly welded to MS angle iron frame 35x35x5mm including frame work as per existing size with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.(a) M&L for brick work using sub class 'B' (old size bricks) in CM 1:4 (b) M&L for rendering 15 mm thick in CM 1:4 finishing even and fair (c) M&L for PCC 1:2:4 type B-0 (using cum 12.5 mm graded stone aggregate) as in coping (d) M&L for any type of mild steel work such as frame sheet 3 mm thick including welding (e) M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer to untreated steel surface & prep of surface complete all as specified and as directed.
M&L for earthing complete with galvanized iron or steel or steel earth plate electrode of size 60cmx60cmx6.3mm thick buried directly in ground, vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI Strip of size 32x6 mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe light grade 20 mm bore for watering including providing funnel and wire mesh GI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40mm graded stone aggregates complete including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in plate No 5 of SRR-1991 Part-1.
Taking down old unserviceable any type fitting and S&F S&F LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
SUNRISE ENGINEERS AND CONTRACTOR (BID ID -3368911)
J.K & Company (BID ID -3377593)
G M BUILDERS 36 (BID ID -3368840)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .