| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 CrAccepted-AOC VARAD PLOT NO 11 DURGA NAGAR KAMATHWADE NASIK 422010 | NASHIK | MAHARASHTRA | 422010 | ₹3.7 Cr Quoted ₹3.8 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹5.2 Cr+₹1.4 Cr (37.7%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | ₹5.2 Cr+₹1.4 Cr (37.7%) | L2 | Rejected-Finance NOT THE LOWEST |
| 3 | L3₹6.0 Cr+₹2.3 Cr (61.1%)Rejected-Finance | ₹6.0 Cr+₹2.3 Cr (61.1%) | L3 | Rejected-Finance NOT THE LOWEST |
| 4 | L4₹6.2 Cr+₹2.5 Cr (66.2%)Rejected-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | ₹6.2 Cr+₹2.5 Cr (66.2%) | L4 | Rejected-Finance NOT THE LOWEST |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Meeting Eligibility Criteria |
Tender Value
₹4.3 Cr
EMD Value
₹5.0 L
Closing Date
21 Jan 2020, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg Camp Pune 411001
DEMOLITION AND RECONSTRUCTION OF PRIMARY SECTION SCHOOL BUILDING AT KENDRIYA VIDYALAYA ATRY CENTRE NASIK ROAD CAMP
2019_MES_294444_2
84452/E8
Open Tender
Civil Works
Lump-sum
365 days
Nasik Road Camp
As per tender documenta
6 documents required · 6 mandatory
₹2,000
GE NRC NASIK
₹5.0 L
19 Feb 2020
27 Dec 2019
22 Jan 2020
27 Dec 2019
21 Jan 2020
7 Jan 2020
28 Dec 2019 - 4 Jan 2020
Amount
NOTE: Schedule ‘A’ Part I to XI are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-13 only.
Total amount of Sch 'A' Part-I (Building Works)
Total amount of Sch 'A' Part-II (Internal water supply)
Total amount of Sch ‘A’ Part III (Internal Electric Supply)
Total amount of Sch ‘A’ Part IV (External Water Supply)
Total amount of Sch ‘A’ Part V (External Electric Supply)
Total amount of Sch 'A' Part-VI (Road, Path, Hardstanding and Culverts)
Total amount of Sch 'A' Part-VII (Sewage Disposal and Rain water exit)
Total amount of Sch ‘A’ Part VIII (Area drainage)
Total amount of Sch ‘A’ Part IX (Construction of stage)
Total amount of Sch ‘A’ Part X (Excavation, Earthwork & Site Clearance)
Total amount of Sch ‘A’ Part XI (Demolition of existing building)
SCH 'A PART XII (Miscellaneous B/R and E/M works) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
(Demolition and dismantling)
Taking down old PVC high level flushing cistern of any capacity and size including PVC connection complete all as specified and as directed.
Taking down old unserviceable main switch, MCB DBs 2/4/6/8/12 way, including MCB 240/440V, metal plug socket of any capacity including disconnecting submain connection complete all as specified and as directed.
Taking down old unserviceable submain wiring of any size and any type including conduit/ PVC casing capping consealed in or on walls etc complete all as specified and as directed.
Taking down old unserviceable damaged underground cable of any size, any type any make from existing trenches and removing etc complete all as specified and as directed.
Taking down old unserviceable damaged LT panel of any size, any type any make including all unserviceable controls and removing etc complete all as specified and as directed.
(Internal Electric Supply)
M &L for submain wiring with 2 single core FRLS PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 4.0 Sqmm drawn through consealed conduit and including PVC conduit heavy grade with and including 1 single core 4.0 Sqmm 1100 V grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified, directed.
M &L for submain wiring with 4 single core FRLS PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 10.0 Sqmm drawn through consealed conduit and including PVC conduit heavy grade with and including 2 single core 10.0 Sqmm 1100 V grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified, directed.
M &L for submain wiring with 4 single core FRLS PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 6.0 Sqmm drawn through consealed conduit and including PVC conduit heavy grade with and including 2 single core 6.0 Sqmm 1100 V grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified, directed.
Supply & fix ceiling fan, 1200 mm (48") sweep, 5 star rating BEE mark (after assembling the same) with the fan hook/box and connecting up complete with and including electronic fan regulator stepped type flush and with and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of fan complete all as specified and directed Make : Havells Cat No ES-50 or equivalent in makes listed in Appendix 'C'.
Supply & fix exhaust fan 250mm sweep, 1400RPM, single phase, light weight, white/ivory plastic rust proof body & blades, self opening louvers for protection from birds and rain water, fixing by means of rugged bolts, nuts and washers etc on the round hole cut in wall, including three core copper conductor flexible cord of 0.5sqmm cross sectional area of required length from ceiling rose to porcelain connector block of exhaust fan suitable on working AC, SP 230 V electric supply complete all as specified and directed. Make CG cat Brisk air or equivalent in makes listed in Appendix 'C'.
Supply & fix LED tube along with CRCA LED Batten complete LED light fitting fixture including LED Tube and Batten , LED Tube fitting consist of Polycarbonate housing with extruded aluminium heatsink for mounting LED chip , LED tube system wattge consist of 18W / 20 W , 140V -260V AC, System Lumen Output min 1800 Lumen in 18W and 2000 lumen in 20W with 5700 - 6500 K CCT with PF > 0.95 CRI > = 80 and with < = 10 % THD , with Min 2.5 KV Surge protection in Built and LED batten consist of Powder coated CRCA box type batten with decorative end caps should be supplied for installing above LED tubes.connecting completed all as specified and as directed of makes as listed in Appendix 'C'
Supply & fix 10 W LED bulk head fittings including LED lamps , pressure die cast alluminium housing with IP65 rating , LED fixture system wattage of 10W , 140V -260V AC, System Lumen Output min 950 Lumen with 5700 - 6500 K CCT with PF > 0.95 and with < = 15 % THD , with Min 2.5 KV Surge protection in Built and LED fixture with BIS R mark and R registration number, connecting complete all as specified and as directed of makes as listed in Appendix 'C'
Supply & fix 25W LED street Light Pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management with LED PC lens, LED Street Light system wattge consist of 25 W, 140V -260V AC, System Lumen Output min 2550 Lumen in 25W with 5700 - 6500 K CCT with PF > 0.95 CRI > = 70 and with < = 10 % THD , with Min 2.5 KV Surge protection in Built and LED Street Light with BIS R Registraion number and necessary bracket of GI pipe 32mm dia medium grade , 1.2m bent with and including two clamps made of MS 30x5mm flat iron and connecting complete all as specified and as directed of makes as listed in Appendix 'C'.
Supply & fix 10W to 12W, LED circular surface mounted fitting pressure die cast Aluminum heat sink with PC Diffuser , LED Fixture System wattage of 10 W / 12W , 140 V -260 V AC, System Lumen Output min 1000 Lumen in 10 W and in 1200 lumen in 12W with 5700 - 6500 K CCT with PF > 0.95, CRI>=80 and with < = 15 % THD , with Min 2.5 KV Surge protection in built and complete LED fixture with BIS R mark and R registration No, connecting complete all as specified and as directed of makes as listed in Appendix 'C'.
Supply & fix Square 2'x 2' , 36W -42W, surface mounted, Bottom opening, LED Cleanroom fitting including LED Lamp with powder coated CRCA housing and polycarbonate diffuser, LED Fixture System wattage of 36-42W, 140V-260V AC, System Lumen Output min 3600 Lumen in 36w and 1200 lumen in 42 w, with 5700 - 6500 K CCT with PF > 0.95 CRI > = 80 and with < = 10 % THD , with Min 2.5 KV Surge protection in built and complete LED fixture with BIS R mark and R registration No, connecting complete all as specified and as directed of makes as listed in Appendix 'C'.
Supply & fix 2x6w double head mirror light LED batten fixture with IP20 moisture protection, Premium opel glass housing and chrome mounts, LED fixture system wattage of 6w each, 140V-260V AC, System Lumen Output min 600 Lumen in 6w with 5700 - 6500 K CCT and connecting complete all as specified and as directed of makes as listed in Appendix 'C'.
S&F RCBO 100 Amps, 30mA, 4 Pole, IP 20, on/off indication complete all as specified and directed.
S&F RCBO 63 Amps, 30mA, 4 Pole, IP 20, on/off indication complete all as specified and directed.
S&F Isolator TPN 415 Volts 40 Amps complete all as specified and directed.
S&F MCB Single pole and neutral 240 volts 6 Amps to 32 Amps 10 KA complete all as specified and directed.
S&F MCB Single pole 240 volts 6 Amps to 16 Amps 10 KA complete all as specified and directed.
S&F Blanking plate of PVC complete all as specified and directed.
(Fire fighting & Fire extinguisher)
Material & labour for Fire alarm sounders/ sirens electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB,1000m range ( Confirming to IS 1941 suitable for three phase 415 Volts, supply with motor not exceeding 3.75KW power and able to deliver 143DB noise level complete all as specified and directed by Engr-in-charge.
Supply and installation of fire extinguisher mechanical foam (AFFF type) 09 Ltrs capacity confirming to IS 15683 complete all as specified and directed by Engr-in-charge.
Supply and installation of fire extinguisher dry chemical powder (ABC type) 06 Kgs capacity confirming to IS 15683 complete all as specified and directed by Engr-in-charge.
Supply and installation of fire extinguisher CO2 type (ABC type) 4.5 Kgs capacity confirming to IS 15683, Fire Rating : 3A, 34B complete all as specified and directed by Engr-in-charge.
Note for Item No 5.02 to 5.04: Between two classes, Mass Spectrometer Hellium Leak Detection Test and 24 Hrs leakage test from authority of Quality Control Department should be submitted and rate of the testing is deemed to be included in the quoted rates of respective item.
(Road, Path, Hardstanding and Culverts)
M&L for 60mm thick machine pressed pre-cast cement concrete interlocking paver blocks with grey cement and pigment, rubber moulded any shape and size confirming to IS 15658-2006, M-35 grade as in floor/pavement laid over and including 30mm thick crushed stone sand complete all as specified and as directed.
(External Electric Supply)
Supply, installing, testing and commissioning of transformer, step-down, outdoor type copper wound, 11KV on HT side and 433 Volts on LT side at no load 3 phase 4 wire 50 c/s AC supply of 160 KVA, oil immersed laminated iron core naturally cooled with external cooling tubes, delta connected on HT side and star connected on LT side, corresponding to vector group DY-11 with natural brought out separately for earthing , off load , changing tap arrangements upto +/- 7.5% with a step of +/- 2.5% complete with first filling of transformer oil upto appropriate level and complete with standard fittings confirming to IS-1180 energy efficient level 3 or latest IS, all as specified in patricular specifictions with and including transformer plinth size 2mx2mx1.5m to mount the transformer. PCC platform for transformer shall be provided as per CEPZ TD drawing and rate quoted for this item will be inclusive of PCC platform.
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including GI strip 32x6 mm by means of bolts, nuts & checknuts and washers etc; GI pipe 40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including Galvanised steel earthing wire 4mm dia by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
Supply, installing, testing and commissioning, weather, dust and vermin proof (CPRI Approved) LT feeder pillar panel board factory made, indoor type, as per IS-8623 fabricated with 2mm thick CRCA sheet epoxy powder paint by means of electro static gun after rogorous pre treatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 400Amp rating bus bar of high conductivity copper alloy for phases and half for neutral and shall be provided with colour coded head shrinkable sleeves, including bottom gland plate consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent ingress of water/vermin etc., inside the enclosure the required No of holes to be fixed with chromium plated brass cable glands for incoming and outgoing cables, with necessary internal wiring with stranded copper conductor PVC insulated cable of adequate quantity including . The panel shall be fixed with angle iron frame made of angle 50x50x6mm and 750mm above thenormal ground wih internal connection with suitable size copper conductor , cable lugs, and cable glands , PCC foundation in cement concrete 1:3:6 type C-1 using 20mm graded coarse stone aggregates and testing after installation with two coats of synthetic enamel paint over a coat of red oxide primer including necessary fixed on wall comprising of the following:-
(a) Copper bus bar 400Amps-03 Nos for phases and half for neutral duly colour sleeved mounted on epoxy/FRP bus bar-01 Set
(b) Incoming
i) MCCB 300 Amps, TPN, 35 KA Breaking capacity, 415V, 50Hz - 01 No
(c) Outgoing
i) MCCB 100 Amps, TPN, 415V, 50Hz, 25 KA - 01 No.( O/G for light load G/F Power Points)
ii) MCCB 63 Amps, TPN, 415 V, 50 Hz, 25KA -03 No.( For ground floor AC Power point)
iii) MCCB 63 Amps, TPN, 415 V, 50 Hz, 25KA -01 No.( O/G for first floor)
iv) MCCB 63 Amps, TPN, 415 V, 50 Hz, 25KA -01 No.( O/G for spare)
vii) CT' with suitable ratio -01 No
ix) Phase indicator lamps with fuse (RYB) -Set of three-01No
x) Internal wiring with single core copper conductor cable/PVC insulated copper strip of suitable size incoming to bus bar and bus bar to out going MCCB/MCB
xi) Fine wiring with single core copper conductor cable for instruments /indicating lamps.
Supply, installing, testing and commissioning, weather, dust and vermin proof (CPRI Approved) LT panel cubical type totally enclosed outdoor type factory made, as per IS-8623 fabricated with 3.15mm thick CRCA sheet with projected globe roof for rain water protection, epoxy powder paint by means of electro static gun after rogorous pre treatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 400Amp rating bus bar of high conductivity copper alloy for phases and half for neutral and shall be provided with colour coded head shrinkable sleeves, including bottom gland plate consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent ingress of water/vermin etc., inside the enclosure the required No of holes to be fixed with chromium plated brass cable glands for incoming and outgoing cables, with necessary internal wiring with stranded copper conductor PVC insulated cable of adequate quantity including . The panel shall be fixed with angle iron frame made of angle 50x50x6mm and 450mm above the normal ground wih internal connection with suitable size copper conductor , cable lugs, and cable glands , PCC foundation in cement concrete 1:2:4 type B-1 using 20mm graded coarse stone aggregates in foundation, fly ash brick work in cement mortar 1:6, rendering to exposed surfaces in cement mortar 1:6, 100mm thick PCC 1:3:6 type C-1 using 20mm graded coarse stone aggregates and testing after installation with two coats of synthetic enamel paint over a coat of red oxide primer including necessary fixed on wall comprising of the following:-
(a) Bus bar chamber comprising 4Nos Copper strip bus bars air insulated and PVC sheathed capacity 400Amps with colour coding in separate sheet steel enclosure-01 Set
(b) Incoming
i) MCCB 300Amps, FP, 35 KA Breaking capacity, 415V, 50Hz - 02 No (One incoming/outgoing from transformer and one spare)
(c) Outgoing
i) MCCB 160 Amps, FP, 415V, 50Hz, 25 KA - 03 No.( 01 for proposed feeder pillar box and 01 for existing panel of school bldg/staff qtrs and 01 spare)
ii) On load change over switch 250A, 440 V, AC
iii) MCB 40 Amps, FP, 415V, 50Hz, 10 KA - 01 No.( for street light )
iv) Power contactor MNX-40 type with coil voltage 415/440 volts, 50Hz-01 No -
v) Universal type switches, suitable for street light flush mounting type FM/QT, one daily dia, 240V, AC make L & T / Seimens/C&S/Crompton
vi) 40 Amps 4 pole 2 way centre change over switch-01 No
vii) Epoxy insulators 40x40x8-04Nos
x) LED/Neon type indicator lamps (RYB) -Set of three-01No
xi) Internal wiring with single core copper conductor cable/PVC insulated copper strip of suitable size incoming to bus bar and bus bar to out going MCCB/MCB-1job
xii) Fine wiring with single core copper conductor cable for instruments /indicating lamps.
xiii) Trivector meter three phase, four wire, 3x240 volts. 10-60Amps class 1.0 with box
M & L for excavation by trench less technology i.e boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique with and including provision of HDPE pipe 150mm bore suitable for 0.4mpa working pressure complete all as specified and as directed.
Supply, fix, test and connecting of LED street light fittings including lamp, 70watt, IP 65, aesthetically designed roadway luminaire with excellent thermal management with and including suitable size copper conductor weather proof, connecting complete all as specified and directed all as per makes listed in Appendix 'C'.
S & F post top lantern LED type light fittings with lamp, IP-65 rated LED Post Top ideal to lit up parks, garden ways, gate and heritage sites 20 watt, complete with all accessories and all as specified and as directed all as per makes listed in Appendix 'C'.
S & F factory made PVC Junction boxes 240x130x110mm, bus bar with insulator for phase & neutral, DIN rail 12cm for mounting MCBs complete with industrial connector including two Nos clamps, made out of MS flat iron 40x4mm with nuts & bolts including connections from junction box to street light fittings with 3 core PVC insulated & PVC sheathed copper conductor cable 1.5sqmm and two Nos MCB SP of 6Amp 240 V, 10kA rating control complete all as specified and as directed of make Sintex cat No GS-JB-2817 oe equivalent in National/ Standard/Hansel.
M & L for fabrication and fixing of brackets made of GI pipe 40mm dia 1.2 M length, medium grade tube including two Nos of clamps made out of MS flat iron of size 30x5mm fixed with and including GI bolts, nuts and washers complete fixed with suitable size screws complete all as specified and as directed..
M & L for PVC insulated 3 core 2.5 sqmm multistranded (un armoured 2XY) copper conductor for connection of security light from junction box to security light/OH conductor to security light fitting complete all as specified and as directed.
M & L for radium sticker of different colour 80cm above coping of pole, i.e. alternatively with sky blue/red & white radium sticker(10cm-04 sky blue/ red strip and 10cm width -04 white strip) complete circumference of any type any shape of pole etc. complete all as specified and as directed.
AGRAWAL ASSOCIATES
DARSHAN CONSTRUCTION Co.
VIRENDRA FABRICATORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .