| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹28.2 L+₹1.4 L (5.38%)Rejected-AOC UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹28.5 L+₹1.8 L (6.84%)Rejected-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹30.0 L+₹3.2 L (12.2%)Rejected-AOC FLAT NO 703 7TH FLOOR PARVATI ENCLAVE PLOT NO 180 SECTOR 2 TOLOJA PANCHANANDTAL TALOJA MAJKUR DISTT RAIGAD MAHARASHTRA 410208 | RAIGAD | MAHARASHTRA | 410208 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹33.5 L+₹6.8 L (25.3%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
13 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW BHANDUP
GE(NW) BAHDNUP, MUMBAI
ADDN and ALTN AND IMPROVEMENT TO NS 162 AND CERTAIN DUs IN MOORA AT MO (MB) GHATKOPAR UNDER GE(NW) BHANDUP
2022_MES_545386_1
8225/B
Open Tender
Civil Works
Item Rate
180 days
GHATKOPAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹84,000
Yes
5 Dec 2022
13 Aug 2022
15 Sept 2022
13 Aug 2022
13 Sept 2022
30 Aug 2022
Amount
Demolition of cement concrete ( reinforced) as in roofs, shelves, chajjas, floors ( other than ground floors), beams, staircase, landing, chajjas , parapet, water tank and similar suspended work etc. and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L for excavation in trenches, n.exc 1.5m wide and exc 1.5m depth for foundation, plinth beam etc and getting out in soft/ loose soil complete all as specified and directed
M&L for Plain cement concrete type D2 1:4:8 (using 40mm graded stone aggregate ) in foundations, filling and mass concrete specified and directed.
M&L for RCC 1:2:4 (20mm graded aggregate) as foundation,footing, plinth beam and base of column etc complete all as specified and as directed
M&L for formwork to sides of concrete as in foundation, footing, base of columns and plinth beam rough finished of surfaces complete all as specified and as directed.
M&L for returning,filling in including spreading, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or stone wall and ceiling surface including raking out joints, hacking for key, scrubbing down with water etc and disposing off the rubbish outside MD land complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frames) and including grills/ guard bars not exceeding 1.5 Sqm each complete as directed
Taking down chowkat or frame with shutter (without taking off shutter from the frames) and including grills/ guard bars exceeding 1.5 Sqm but not exceeding 4.0 Sqm each complete as directed
S&F II nd class Hard Wood as in plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints etc all as specified
S& F 35mm thick second class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze, etc ( with sash bars), edges of framing plain, chamfered or rounded , fitted with cut and mitered beads for securing glass, etc size of members of shutters as specified & directed in SSR Part-I , section 8, clause 8.24 (a) complete all as specified and directed.
Dismantling of roof terracing cement / brick concrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified and directed.
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate with 2% by weight of cement or as per manufacturer's instructions water proofing as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc complete all as specified and directed.
M&L for supply and application of 7 layer SHR water proof coating system on leaking concrete surface by thorough surface preperation, opening of cracks, followed by one absorption coat of thermacool WP51, nano modified, UV resistant elastomeric clear coating having min 50% solids, filling of cracks, then over coating with sand witch coat of elastomeric ( Thermacool WP51 +Cement) water proofing layer with 80 GSM non woven fibre mesh, application of 3rd coat of elastomeric water proofing layer having 450% elongation ,tensile strength min 2.2MPa and then top coated with two coats of thermacool 0.3c pure acrylic based UV resistant , non yellowing bio organism resistant (anti fungal, anti bacterial) solar reflective coating confirming to BIS STTD IS 17218: 2019 with pull off adhesion 2.8MPa, passes 20 hrs accelerated durability test, suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25sqm/ltr/2 coat ,DFT 100-120 microns using brush, roller, airless spray gun as applicable and application is to be done with Thermacool approved applicator with ten year guarantee all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc out side MD land complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in kitchen platform and similar work laid, bedded and pointed in cement mortar and removal of rubbish/ demolished materials out of MD land complete all as specified and directed
M&L Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:6 laying floor finishesed complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in vertical surface etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles.complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.06 sqm n exc 0.11 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 laying floor finished complete all as specified and directed.
M&L for glazed ceramic coloured tiles 450x300/350mm x 7mm thick in vertical surfaces such as skirting/dado and risers to steps and including over 10mm thick rendering in CM 1:3 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, all as specified and directed.
M&L for 20 to 25mm machine cut pre polished kota stone slab for steps in single piece with round nosing with three numbers of serration as in treads of steps for staircase laid over cement screed bed and jointed with grey cement slurry mixed with pigment to match the shade of of the slab including rubbing and including over 15mm thick screed bed or bedding layer in CM1:4 complete all as specified and as directed.
M&L for 20 to 25mm machine cut pre polished kota stone slab as in riser of steps, skirting, window cills,dado and pillar in single piece, laid over cement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and including over 10 mm thick Rendering in CM1:4 complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 20 - 25mm thick over 20mm cement screed in CM 1:6 laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including mirror polishing complete all as specified and as directed .
M&L for 20 to 25mm thick machine cut and machine polished cudappa stone slab for shelves jointed and set in CM 1:3 and fixed including rounding to edge of stone slabs one side edge complete all as specified and as directed
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M & L for rendering 10 mm thick in CM 1:6 on brick walls or concrete surfaces and finishing the surfaces even and smooth complete all as specified and directed.
M & L for rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling and finishing the surfaces even and smooth complete all as specified and directed.
M&L for 20mm thick (12mm + 8mm) in two coats polymer modified ready mix cement based plaster on the wall surface including finishing the surfaces of top layer in the proportion as per manufacturer recommendation, for the under mentioned storeys of the existing buildings, complete all as specified and directed. Note : The thickness of plaster specified above is the minimum thickness and the quoted rates shall also be demand to included for provision of dubbing of the surfaces with the ready mix plaster and no extra payment shall be admissible on the account”.
M&L for Preparation of New plastered surfaces of wall and applying two coats of Dr fixit rain coat over (of Shade/colour as directed by E-in-C) one coat of Dr fixit prime seal primer all as per manufacturer instruction including necessary scaffoldings etc complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying Two coat of oil bound distemper including application of wall care putty for smooth finish.etc with roller over one coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying with roller Two coat of oil bound distemper including application of white cement based wall care putty finish for smooth finish.etc complete all as specified and directed.
M&L for complete removal of existing treatment from ceiling and thereafter applying two coat of oil emulsion distemper over a coat of primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and directed
M & L for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surface of any discription not otherwise discribed over 10 cm width or girth, complete all as specified and directed.
S&F aluminium section in doors/windows/ventilators ,kitchen cupboards, built n almirah doors any type, powder coated in approved colour (Thickness of powder coating not less than 50 micron), aluminium section (medium weight of series 'B') or section as directed by Engineer-in-Charge, cut to size, jointed together with cadmium plated steel screws including rubber beading or gasket for aluminium sections for fixing glass/XPM jali or for fixing bakelite sheet and all necessary fittings complete, screws, plugs for fixing screws, etc all as specified and directed Notes : (i) Weight of aluminium sections shall only be measured. (ii) The supply only rate of glass pane,wire mesh will be measured separately.
Supply only 4mm thick figured glass/pin headed type ordinary quality fixed in aluminium ventilator n exc 0.50 Sqm each pane complete all as specified and directed.
Supply only stainless steel wire cloth of 0.63 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows complete all as specified and directed.
S&F aluminum anodised grill DG- 202 ( 10 mm x 7.5mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed. Note : (i) Make shall be as approved by the GE. (ii) Minimum thickness of anodizing shall be 15 microns.
S& F 2nd class HW 35 mm thick,plain, framed, panelled shutters (any numbers of panels), with pannels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face neneers;fixed to chowkats complete all as specified & directed.
S&F in repairs SS wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed tinned tacks or aluminium wire staples,and fixing of aluminium windows with rubber beeding complete all as specified and as directed.
M&L for PCC 1:2:4 Type B1 using 20 mm graded aggregate as in hold fast, coping ,cills ,steps, seismic and other similar bands, plinth course, string course, parapets, railing, bed plates, kerbs and the like including weathering,slightly rounded or chamfered angles and throating complete all as specified and directed.
S&F for 20mm dia curtain rods anodised aluminium alloy, power coated with fixing brackets, stops, rollers etc complete all as specified and directed
S&F 100 mm stainless steel butt hinges,complete all as specified and directed
S&F 150mm length aluminium anodised barrel tower bolt of extruded section complete all as specified and directed
S&F 150 mm length extruded aluminium alloy handles,fabricated type, anodised complete all as specified and directed
S&F alluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast alluminium alloy and fixed of length of bolt 300 mm complete all as specified and directed.
Dismantling cast iron pipe and fittings of any description etc complete all as specified and directed
S&F 75mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with GI clamps8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F 110mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with GI clamps8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F 75mm bore PVC (SWR) bends any radius dimnishing pieces or tapers with access doors etc, complete all as specified and as directed.
S&F 110mm bore PVC (SWR) bends any radius dimnishing pieces or tapers with access doors etc, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) junction single (single T ) equal or unequal with access doors etc, complete all as specified and as directed.
S&F in repair PVC floor trap 75mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and as directed.
S&F in repairs vitreous china squatting pan, white, orissa pattern pan of size 580 mm x 440 mm of standard quality with integral foot rests,and including 'P' trap or 'S' Trap complete including connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specifiedand directed.
Supply and fix in repair 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC etc, complete all as specified and directed.
S&F CP concealed stop cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP angle cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP long nose bib tap 15mm bore fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S&Fin repair 15mm size PVC connection with PTMT nuts 450mm length complete all as specified and directed.
S&F in repairs chromium plated shower roses 125mm size with or without swivel joint including fixing to steel pipe or union etc.complete all as specified and directed.
S&F in repair CP Tubular towel rail with hook 20 mm dia 600mm long between flanges of fixed with and including chromium plated brass screws and wooden/plastic screws. complete all as specified and directed.
S&F in repair Soap dish, Stainless steel fancy type approx size 160x160x90mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 25mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 40mm complete all as specified and directed.
S&F CPVC pipe 16 mm outer dia SDR 11and plain CPVC SDR 11 fittings fixed complete to walls, ceilings or in floors etc, complete all as specified and directed.
All as per item No. 71 above but 20 mm bore etc, complete all as specified and directed.
All as per item No. 71 above but 25 mm bore etc, complete all as specified and directed.
All as per item No. 71 above but 40 mm bore etc, complete all as specified and directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 40 mm bore complete all as specified and directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 25 mm bore complete all as specified and directed.
S&F 2000 ltrs Rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I and fixing of Ball valve of size 15mm dia high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Chipping, removing carefully loose/damaged concrete including plastering (total thickness exceeding 40mm but not exceeding 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed. Note : 1) Hard concrete shall not be removed by force
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hour between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for carry out application of ‘Bi-polar migratory corrosion inhibitor' [Make : M/s. Krishna Conchem (EPCO KP-100) / BASF (MasterProtect®8000Cl)] on RCC surfaces, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressedRCC members (exceeding 40mm in thikness) with prebatched, prepacked, single component ready to use microconcrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. (Note : Reinforcement only shall be measured and paid separately).
M&L for building up the profile of structural members using polymer modified mortar from M/s. Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 20mm thickness, including levelling, profiling etc, complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar from M/s Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr. Fixit, exceeding 20mm thick and not exceeding 40mm thick in two layers, each of equal thickness including levelling, profilling etc, complete all as specified and directed.
M & L for TMT steel bars 10 mm dia and over, cut to n length , bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
All as per item No 86 but 5mm dia and over upto and including 10 mm dia in stirrups , spaces and binders complete all as specified and directed.
M & L for post construction anti - termite treatment at points of contact of wood work using chemical emulsion (in oil or kerosin based solution ) @ 0.5 liters per holy by drilling 6 mm dia holes at a down ward angles of 45 degree at 150 mm centre to center and sealing the same with white cement and making good to the existing surfaces etc complete all as specified and directed.
M&L for special treatment for sunken portion of WCs/ Bath & toilet executed in following stages:- Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc including removing debris outside MD land etc Complete. Stage 2:- Providing 10mm thick plaster in CM 1:3 mixed with integral water proofing chemical of Dr. Fixit Pidicrete URP or plaster seal of STP Ltd in the proportion/quantity all as per Manufacture's instructions. Stage 3:- Apply Dr Fixit Primeseal primer or Equivalent of STP Ltd (and allow to dry for 8 hours) all as per Manufacture's instructions. Stage 4:- Apply two coats of water proofing elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP (The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per Manufacturer's instructions. Stage 5:- Rendering 10mm thick in CM 1:3 mixed with Integral water proofing chemical Dr Fixit Pidicrete URP or plaster seal of STP Ltd all as per Manufacture's instructions. Stage 6. All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP all as per Manufacture's instruction. Stage 7:- Making holes in wall and fixing 600mm long 40mm dia medium grade GI spout for draining the surplus water if any Stage 8:- Carry out ponding test for 48 hours to ensure water tightness of repaired sunken portion.water tightness of repaired sunken portion and filling of sunken portion for cement concrete Type E2 1:5:10 using 40 mm graded aggregate as in lean concrete complete all as specified and directed. Note :- (a) Only plan area shall be measured and accorded for payment under this item. (b) Depth of sunken portion of WC's/Baths shall be upto 35cm, which is to be taken into account while quoting the rate against this item. (c) Rate quoted by Contractor shall be deemed to be included for all the horizontal and verticale treated surfaces of sunken portions of WC & Bath.
M&L for Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
Surface excavation n.exc(not exceeding) 30 cm deep and averaging 15cmdeep and getting out in soft/ loose soil complete all as specified and directed.
Removal of surplus soil not exc 50m from starting point and depositing to a point including spreading, watering and well ramming in layers n.exc 15cm thick complete all as specified and directed.
M&L for Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface all as specified and directed
M&L for 100mm PCC 1:4:8 Type D-2 using 40mm graded stone aggregate as in sub base flooring complete all as specified and directed.
M&L for 50mm thick 6mm graded stone aggregate filling under paving or foundations etc including spreading, levelling and well compacted completed all as specified and as directed.
M&L machine pressed precast interlocking paver block any size and shape confirming to IS 15658-2006 of 60mm thickness with grey cement and pigment complete all as specified and directed.
S&F steel work in tubular/ roof trusses(framed), purlins, rafters,brackets, wind ties including distance pieces, cleats, crane gantries, rails and fastenings and heavy bracket framing etc (beam, tee, angle, channel or flat sections and circular sections in columns) etc complete including necessary cutting, welding, fabrication and erection machine hydraulic bending, confirming to Fe 410-W (Gde E-250) Quality-A complete all as specified and directed
M&L for preperation of new steel surfaces of any description over 10cm width or girth not otherwise described two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and directed.
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for Vitrified ceramic tiles light shade 10 mm thick (square/ rectangular) polished ,area of each tile exceeding 0.36 sqm but not exc. 0.42 sqm in floor etc. set and jointed in neat cement shurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 laying floor finished complete all as specified and directed.
M&L for Vitrified ceramic tiles light shade 10 mm thick (square/ rectangular) polished ,area of each tile exceeding 0.36 sqm but not exc. 0.42 sqm in vertical faces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in CM 1:4 on fair faces of brick/ concrete surfaces as in backing coat for tiles finished complete all as specified and directed.
S&F in repair wash down water closet pedestal pattern white and including plastic water closet seat cover as per required colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device (excluding flushing cistern)etc complete all as specified and directed.
S&F in repairs wash hand basin, vitreous china white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets,32mm waste fitting and waste pipe of 32 mm bore, brass, chromium plated for glazed ware wash basin and 15mm dia pillar taps chromium plated fancy type etc complete all as specified and directed.
S&F in repair PVC floor trap with grating complete 100mm bore outlet including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and as directed.
S&F in repairs brass CP mixer hot and cold water screwed down for iron pipe and fixed 15mm bore fancy type complete all as specified and directed.
S&F in repair toilet paper holder complete all as specified and directed.
S&F in repair Health faucet with 1.5m tube & hook complete all as specified and directed.
Cutting and grooving of wall for fixing UPVC pipe line and after fixing of UPVC line and making good of all cutting surfaces complete all as specified and directed.
S&F 15mm bore U PVC pipes of pressure rating 10kgf/cm2 fixed complete to walls , ceilings or in floors etc with all fittings complete all as specified and directed.
Supply and fixing in repairs aluminium alloy wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with wooden berings complete all as specified and directed.
Taking down carefully unserviceable point wiring of any type & pattern (Light/Fan/Socket or power) including unserviceable fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etc and making good disturbed surfaces of walls/ roof etc complete all as specified and directed.
Taking down complete main switches/DBs with enclosure and its components of any size and capacity ,etc complete all as specified and directed.
M & L for point wiring complete with proper colour coding using, 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked drawn in and including PVC conduit (minimum 20mm dia) concealed in wall etc (also including cutting chiseling in wall and making good the same in CM 1:3 to match with the adjoining surfaces) with all accessories, fittings, PVC junction boxes etc, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for one light point /fan/bell point controlled by one one way switch, complete all as specified and directed. Note: Modular flush box and inner/outer plates measured and paid separately.
All as per item No 114 above but for call bell point complete all as specified and directed.
All as per item No. 114 above but for One 2pin/3 pin socket outlet 5 Amps on independent board complete all as specified and directed.
All as per item No. 114 above but for One 2pin/3 pin socket outlet 5 Amps on same board with other switches , complete all as specified and directed.
M&L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH with and in and including PVC concealed conduit having thickness not less than 2 mm with all fittings including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH as earth continuity conductor connected to common earth dolly.and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching existing colour and all as specified . Note: colour coding is to be maintained .(Ph-Red, N-Black, Half-Yellow, Earth- Green). Note: Modular flush box and inner/outer plates measured and paid separately.
Material and Labour for tube light fitting LED 20 watt with decorative end caps made out of CRCA sheet powder coated complete with housing with aluminium heat sink on back of leds ,power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting complete all as per specified and directed.
Material and Labour for tube light fitting LED 10 watt with decorative end caps made out of CRCA sheet powder coated complete with housing with aluminium heat sink on back of led ,power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting complete all as per specified and directed.
M&L for submain wiring in and including PVC conduit having thickness 1.8 mm, 25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 4 sqmm(FRLSH) and one run of PVC insulated, sheathed multistranded copper conductor 4 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. (Note: Two run of 4 sqmm plus one run 4 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed. Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
M&L for ceiling rose three terminals AC 240 volts 50Hz complete all as specified and directed.
Supply and fixing bell ding dong 240 volt Ac 50Hz complete all as specified and directed.
Supply and fixing modular ceiling fan regulator 120 watt 2 module complete all as specified and directed.
M&L for switch modular one way 6/5 amps 1 module complete all as specified and directed.
M&L for switch modular one way 16/20 amps 1 module complete all as specified and directed.
M&L for socket modular 6Amp 2/3 pin combined 2 module complete all as specified and directed.
M&L for socket modular 16/20 Amp 2/3 pin combined 2 module complete all as specified and directed.
M&L modular bell push 6Amp 1 module complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 8 way double door with din rail and 200 Amp bus bar complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 4 way double door with din rail and 200 Amp bus bar complete all as specified and directed.
Supply and fix in repairs MCB SPN 240 Volts 32 Amps C Curve breaking capacity 10 KA rating complete all as specified and directed.
Supply and fix in repairs MCB SP 240 Volts 6 to 32 Amps C Curve breaking capacity 10 KA rating complete all as specified and directed.
Supply and fixing modular metal flush box 1/2 module complete all as specified and directed.
Supply and fixing modular metal flush box 3 module complete all as specified and directed.
Supply and fixing modular metal flush box 6 module complete all as specified and directed.
Supply and fixing modular metal flush box 8 module complete all as specified and directed.
Supply and fixing modular white outer cover plate with inner frame 2 module complete all as specified and directed.
Supply and fixing modular white outer cover plate with inner frame 3 module complete all as specified and directed.
Supply and fixing modular white outer cover plate with inner frame 6 module complete all as specified and directed.
Supply and fixing modular white outer cover plate with inner frame 8 module complete all as specified and directed.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 33557.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
Joy builders
S K ENTERPRISES
DWARKESH STRUCT-CON
M/s Qureshi Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .