Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹10.9 L+₹2.4 L (28.7%)Rejected-Finance | L2 | Rejected-Finance Not being lowest bidder | |
| 3 | L3₹13.4 L+₹5.0 L (59.3%)Rejected-Finance 0 BEECHPARA DANGAURA MAHENDRAGARH MANENDRAGARH CHIRMIRI BHARATPUR CHHATTISGARH 497442 | KOREA | CHHATTISGARH | 497442 | L3 | Rejected-Finance Not being lowest bidder | |
| 4 | L4₹13.8 L+₹5.4 L (63.8%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-Finance Not being lowest bidder | |
| 5 | L5₹15.5 L+₹7.0 L (83.1%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L5 | Rejected-Finance Not being lowest bidder |
| Sl No | Description | Qty | Unit | SKS Electricals L4 | Sachin Electricals L1 | ONKAR ELECTRIC AND GENERAL STORE L5 | ANKUR TRADERS L6 | M/s Pratik Enterprise L2 | MAHALAXMI ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and Labour for point wiring using approved colour coding as per IS ( Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and sheathed FRLS cable1100 volts grade , ISI-694 (1990) marked with valid CML No in and including medium grade,PVC casing & capping of suitable size on walls/roof/floor etc, ISI marked with suitable accessories , PVC box including Modular Plate and Covers for one Fan/Light/bell point controlled by one switch/bell push complete all as specified and directed by engr in charge.
Make: Polycab /Finolex/ RR | 101 | Per point | 700 ₹70,700 | 550 ₹55,550 Lowest | 800 ₹80,800 | 1,100 ₹1,11,100 | 650 ₹65,650 | 575 ₹58,075 |
| 2.00 | Material and Labour for point wiring using approved colour coding as per IS ( Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and sheathed FRLS cable1100 volts grade , ISI-694 (1990) marked with valid CML No in and including medium grade,PVC casing & capping of suitable size on walls/roof/floor etc, ISI marked with suitable accessories , PVC box including Modular Plate and Covers for one 5 Amps socket on Independent board controlled by one switch complete all as specified and directed by engr in charge.
Make: Polycab /Finolex/ RR | 430 | Per point | 700 ₹3,01,000 | 600 ₹2,58,000 | 850 ₹3,65,500 | 1,200 ₹5,16,000 | 680 ₹2,92,400 | 575 ₹2,47,250 Lowest |
| 3.00 | Supply and fix modular switch 1 way 6A 1 module complete all as specified and directed. | 585 | Each | 61 ₹35,685 | 70 ₹40,950 | 120 ₹70,200 | 200 ₹1,17,000 | 80 ₹46,800 | 60 ₹35,100 Lowest |
| 4.00 | Supply and fix modular socket 6A 2/3 pin combined 2 module complete all as specified and directed. | 444 | Each | 150 ₹66,600 | 85 ₹37,740 Lowest | 160 ₹71,040 | 300 ₹1,33,200 | 130 ₹57,720 | 110 ₹48,840 |
| 5.00 | Supply and fix modular socket 16A 2/3 pin combined 2 module complete all as specified and directed. | 32 | Each | 270 ₹8,640 | 130 ₹4,160 Lowest | 260 ₹8,320 | 500 ₹16,000 | 220 ₹7,040 | 130 ₹4,160 Lowest |
| 6.00 | Supply and fix modular switch 1way 16A 1 module complete all as specified and directed. | 32 | Each | 208 ₹6,656 | 130 ₹4,160 | 300 ₹9,600 | 300 ₹9,600 | 170 ₹5,440 | 100 ₹3,200 Lowest |
| 7.00 | Supply and Fix wall study lamp LED bush light with die cast aluminium housing with toughned glass 6 watts including necessary eletric connection with PVC insulated multistranded copper cable of suitable size from ceiling rose/junction box to fitting terminal complete all as specified and directed.
Make: Halonix/Havells/Philips/Surya | 101 | Each | 2,600 ₹2,62,600 | 850 ₹85,850 | 1,800 ₹1,81,800 | 500 ₹50,500 Lowest | 1,300 ₹1,31,300 | 2,640 ₹2,66,640 |
| 8.00 | Material and Labour for point wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 V grade multi stranded copper conductor drawn through non metallic rigid PVC conduit and accessories in surface of walls/ceilings including 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including PVC boxes of suitable size/thickness to provision of Modular switches to house switch/regulators etc including Modular Plate and Covers for one fan/light /bell point controlled by one switch/bell push complete all as specified and directed.
Note :-
(i) The work is to be carried out in bldg at a height upto 7 mtrs (Approx).
(ii) The cost of T&P involved in doing the wiring work is included in the quoted cost.
(iii) The contractor has to visit the site and check the site conditions before quoting the tender. | 40 | Per point | 900 ₹36,000 | 900 ₹36,000 | 855 ₹34,200 | 300 ₹12,000 Lowest | 850 ₹34,000 | 500 ₹20,000 |
| 9.00 | All as per item No 8 above for one 3 pin 5 Amps socket on same board controll with other switches on same board | 4 | Per point | 150 ₹600 | 200 ₹800 | 60 ₹240 Lowest | 200 ₹800 | 130 ₹520 | 120 ₹480 |
| 10.00 | All as per item No 8 above for one 3 pin 5 Amps socket on independent board | 10 | Per point | 900 ₹9,000 | 950 ₹9,500 | 650 ₹6,500 | 200 ₹2,000 Lowest | 950 ₹9,500 | 480 ₹4,800 |
Tender Value
Refer Docs
EMD Value
₹35,790
Closing Date
26 Jun 2026, 6:00 pmClosed
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
PROVN OF STUDY LAMPS AND ADDITIONAL 5 AMPS AND 15 AMPS SOCKETS FOR BLDG NO P 112 P 113 AND P 110 OF 13 MAHAR AND PROVN OF PVC FLASE CEILING AND OTHER CONNECTED ITEMS IN BLDG NO 176 AT AUNDH MIL STN UNDER GE MH AND RH KHADKI
2026_MES_769921_1
8885/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹35,790
12 Aug 2026
5 Jun 2026
29 Jun 2026
5 Jun 2026
26 Jun 2026
19 Jun 2026
5 Jun 2026 - 26 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and Labour for point wiring using approved colour coding as per IS ( Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and sheathed FRLS cable1100 volts grade , ISI-694 (1990) marked with valid CML No in and including medium grade,PVC casing & capping of suitable size on walls/roof/floor etc, ISI marked with suitable accessories , PVC box including Modular Plate and Covers for one Fan/Light/bell point controlled by one switch/bell push complete all as specified and directed by engr in charge.
Make: Polycab /Finolex/ RR | 101 | Per point | - | - |
| 2 | Material and Labour for point wiring using approved colour coding as per IS ( Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and sheathed FRLS cable1100 volts grade , ISI-694 (1990) marked with valid CML No in and including medium grade,PVC casing & capping of suitable size on walls/roof/floor etc, ISI marked with suitable accessories , PVC box including Modular Plate and Covers for one 5 Amps socket on Independent board controlled by one switch complete all as specified and directed by engr in charge.
Make: Polycab /Finolex/ RR | 430 | Per point | - | - |
| 3 | Supply and fix modular switch 1 way 6A 1 module complete all as specified and directed. | 585 | Each | - | - |
| 4 | Supply and fix modular socket 6A 2/3 pin combined 2 module complete all as specified and directed. | 444 | Each | - | - |
| 5 | Supply and fix modular socket 16A 2/3 pin combined 2 module complete all as specified and directed. | 32 | Each | - | - |
| 6 | Supply and fix modular switch 1way 16A 1 module complete all as specified and directed. | 32 | Each | - | - |
| 7 | Supply and Fix wall study lamp LED bush light with die cast aluminium housing with toughned glass 6 watts including necessary eletric connection with PVC insulated multistranded copper cable of suitable size from ceiling rose/junction box to fitting terminal complete all as specified and directed. | 101 | Each | - | - |
| 8 | Material and Labour for point wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 V grade multi stranded copper conductor drawn through non metallic rigid PVC conduit and accessories in surface of walls/ceilings including 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including PVC boxes of suitable size/thickness to provision of Modular switches to house switch/regulators etc including Modular Plate and Covers for one fan/light /bell point controlled by one switch/bell push complete all as specified and directed.
Note :-
(i) The work is to be carried out in bldg at a height upto 7 mtrs (Approx).
(ii) The cost of T&P involved in doing the wiring work is included in the quoted cost.
(iii) The contractor has to visit the site and check the site conditions before quoting the tender. | 40 | Per point | - | - |
| 9 | All as per item No 8 above for one 3 pin 5 Amps socket on same board controll with other switches on same board | 4 | Per point | - | - |
| 10 | All as per item No 8 above for one 3 pin 5 Amps socket on independent board | 10 | Per point | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.61 MB
BOQ_862196.xls
BOQ • 0.26 MB
TENDER8885.pdf
Tender Documents • 22.16 MB
Amendments.pdf
PDF • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .