Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹39.9 L+₹2.1 L (5.44%)Rejected-AOC | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹45.7 L+₹7.9 L (20.9%)Rejected-AOC | L3 | Rejected-AOC Other than L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
11 Jan 2024, 6:00 pmClosed
Garrison Engineer
Garrison Engineer (North) Akhnoor- 181201 C/o 56 APO
COMPREHENSIVE REPAIR/MAINT OF WATER SUPPLY PIPE LINES, VALVES, PUMPING SETS, STARTER PANELS, DOZING PLANTS, EARTHINGS, PAINTING WORKS, INSTALLATION DISTRIBUTION PANELS AND CONNECTED ITEMS AT SUNDERBANI UNDER GE (NORTH) AKHNOOR
2023_MES_632755_1
CANO- GE(N)/AKH-48/2023-2024
Open Tender
Support/Maintenance Service
Item Rate
180 days
Sunderbani
Class D category a(ii), b(i)
9 documents required · 9 mandatory
₹500
GE (N) Akhnoor
₹90,000
Yes
6 Mar 2024
14 Dec 2023
18 Jan 2024
14 Dec 2023
11 Jan 2024
28 Dec 2023
Amount
Scrapping existing painting of pumpset of capacity 60 HP incl painting of steel base structure, exposed suction/delivery pipe, valve header complete with emery paper/ wire brush and repainting with two coat of synthetic enamel paint of colour approved by Engr-in-charge all as specified and directed. Make of paint:-Asian , Berger, Durolux or equivalent as approved.
Scrapping existing painting of pumpset of capacity 20 HP incl painting of steel base structure, exposed suction/delivery pipe, valve header complete with emery paper/ wire brush and repainting with two coat of synthetic enamel paint of colour approved by Engr-in-charge all as specified and directed. Make of paint:-Asian , Berger, Durolux or equivalent as approved.
Taking down old unsv PCC poles and Supply and fixing Steel tubular poles, swaged type, 410-SP-31, 9m long with 300x300x6mm thick MS base plate continuously welded to pole with MS sheet 2mm thick plug welded at top, bolts, nuts and screws all as specified including two coats of black bituminous paint internally throughout and externally for embedded portion and two coats of aluminium paint over a coat of red oxide primer on exposed surfaces including painting up to 1.5 mtr height from ground level or above coping with two coats of synthetic enamel paint in 30cm strip, alternate balck & yellow starting with block at ground level, complete all as specified and directed. (Note:- Excavation and earth work and PCC shall be measured & paid separately)
Plain Cement Concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregates) as in coping of poles etc including weathring, slightly rounded or chambered angle and throating, necessary form work finishing all exposed faces of concrete etc complete all as specified and directed.
Plain Cement Concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation of electric poles/struts etc including necessary form work and fair finish to exposed surfaces, complete all as specified and directed.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint all as specified and directed.
Plain Cement Concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete all as specified and directed.
Taking down old/unsv flood lights from high mast light of any type and supply and fixing LED flood light of capacity 100 watt IP 66 Lumainire with aluminium die cast housing toughened glass and unique lens system for enhancement illumination with all accessories, complete all as specified. Make Wipro cat part No LF20-122-060-57-G2 or its equivalent in specification of make phillips, Oshram,wipro, GE as approved.
Taking down 60 HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting, and rewinding with super enamelled copper wire of best quality of existing size/guage and weight including replacement of insulation material ,varnish,bearing,connection plate and all other petty items required to make motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed.
Taking down 20 HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting, and rewinding with super enamelled copper wire of best quality of existing size/guage and weight including replacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. Note for srl item No 9 & 10 (i) Transportation charges from installation to contractor workshop and back after repair are deemed to be included in the unit rate quoted for above item. (ii) Cost of nuts, bolts, washers,connection plate,greese lubrication to bearing bushes ets are deemed to be included and However, supply only bearings and terminal plates will be measured and paid separetly under respective items.
Supply only the following parts for incorporating in item No 9 and 10 here-in-before :-
Motor bearings for 60 HP motor as per sample Make SKF/NBC, as approved.
Motor bearings for 20 HP motor as per sample Make SKF/NBC, as approved.
Terminal plate with brass nuts, washers suitable for 3 phase 60 HP Motor, as approved.
Terminal plate with brass nuts, washers suitable for 3 phase 20 HP Motor, as approved.
"Supply and fixing in replacement of LT Panel board indoor type with neoprene rubber gasket and locking arrangement vermin/ dust/ weather proof, self ventilation with wire mesh at suitable interval on both side, totally enclosed bus bar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2 mm thick CRCA sheet duly powder coated paint factory made (CPRF approved), 415 volts, TPN, 50 Hz both sides properly welded MS angle 50x50x6mm 4 Nos, at all vertical corners grouted in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) and connecting the incoming/ out going feeders by providing cable glands and cable lugs complete all as specified and didrected compprising of following accessories.Make of panel- Indian Transformers & Electricals Pvt Ltd. Gurgaon, Legrand, Schnieder, L&T Note :- Panel should be TTA in accordance with IEC 61439 part I &II and shall comprise the following :-
(i) MCCB TP NL LT 415 volt 50 Hz, AC 160 Amps 36 KA with adjustable thermal setting With on/off/trip indicator.and Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 01 No Make :-L&T/legrand/Schneider (ii) Soft Starter 60 H.P. contactors, relays, CT/PT, timers, ROM for suitable rating having inbuilt display with ON, OFF , Trip Indicating Light, Push Buttons, Digital MFM with CT, Control Fuse etc fitted in panel board for showing V,I,Hz,Pf complete all as specified and directed- 01 Nos.Make-L&T/Siemen/Schnieder (iii) Smart Motor Controller Protection Having Feature as Protection against UV,OV, Phase loss,Phase unblanced , Phase Asymetery & Auto Phase Polarity Correction with Time Delay & Having Display of V, I ,Pf, Hz for 100 Amp - 1 No.
Dismantling and Taking down centrifugal pumpset from plateform and disconnecting suction and delivery pipe line and electrical connections, transport the same to workshop for repair and after repairing transporting the pumpset from workshop to site , installation at site connecting suction and delivery pipe and electrical connection complete all as directed by Engineer-in-charge for 60 HP pump capacity Note :- The rate is deemed to be included the cost of providing foundation nuts,bolts and washers gland packing, greasing,oiling and oil sheet gasket (ii) The spare parts will be measured and paid separately under relevant items of supply only.
Description all as per Srl Item No 13 above, but of capacity 20 HP.
Supply only the following parts for incorporating in 60HP Capacity centrifugal pumpset:-
Bronze impeller
Casing ring
Impeller ring brass nut
Impeller key
Coupling key
Coupling rubber bushes
Shaft sleeve(steel)
Bearing
Shaft (steel)
Brass bush
Gland bolt/nut
Supply only the following parts for incorporating in 20HP Capacity centrifugal pumpset:-
Bronze impeller
Casing ring
Impeller ring brass nut
Impeller key
Coupling key
Coupling rubber bushes
Shaft sleeve(steel)
Bearing
Shaft (steel)
Brass bush
Gland bolt/nut
Lifting submersible pump from the existing bore hole/tube well for repairs complete including disconnecting electric connections from starter, disconnecting the water connections carefully by unscrewing the nuts, bolts, washers, rubber flanges etc and taking out the submersible pump set of capacity 12.5 HP with column pipes of size 80/100/150 mm bore and two runs of submersible cable and stacking properly for reuse and lowering complete in borewell after repairs from workshop, rejointing each column pipe, submersible cable connection, testing, complete all as specified & directed. Note:- (i) Transportation charges from installation to contractor workshop and back after repair are deemed to be included in the unit rate quoted for above item (ii) Cost of nuts, bolts, washers,connection plate, greese lubrication to bearing bushes ets are deemed to be included in the quoted rates. However, Supply of relevant parts of pumps and motors will be measured and paid separetly.
Supply only following spare parts for submersible pumpset:-
Impeller brass
Stage bowl
Bowl fixing steel nut and bolt
Bearing sleeve
Bearing bush
Neck ring
Casing wear ring
Shaft steel
Strainer
Stage gasket
Rewinding of AC 3 phase submersible motor of capacity 12.5 HP by cutting of burnt out winding, cleaning of starter slots, cleaning,bleaching of motor and rewinding with appropriate guage of copper winding wire complete including all required parts complete all as specified and directed. Note: Taking down of unsv parts and fixing the same with new ones in the item No will be taken under relevant items here-in-after.
Supply only following spare parts of motor of submersible pumpset:-
Thrust bearing plate
Motor bearing bush
Assembly for coupling sleeve
Drain plug
Sand guard
Key for thrust plate
Supply and fixing Vinyl display board of frame size 6 ft x 4 ft showing schematic diagram of electric/water supply distribution network as sketch provided to be fixed on walls in installation all as specified and directed.
Supply and fixing Acrylic sheet display board frame size 3 ft x 2 ft showing schematic diagram of electric/water supply distribution network as sketch provided to be fixed on walls in installation all as specified and directed.
Material and labour for Retro reflective installation sign board size 6ft x4 ft fabricated out of 1.6mm MS sheet frame welded/riveted with stainless steel pipe finished in square of size 25mmx25mm at 2.5m height from ground level on stainless steel finished pipe of size 50mm fixed with PCC 1:2:4 Type B-1 of block size 45cmx45cmx60cm.The board shall be painted in stove enamelled paint and the front and back of the frame shall be overall sheathed with blue colour base painter adhesive tape. The writting matter will be in English language on both sides with reflective adhesive paint tape all as specified and directed.
Supply and fixing in replacement of LT Panel Board, indoor type of suitable size as per relevent IS, mounted on angle iron legs of size 40x40x6mm embedded in PCC 1:2:4 block type B-2 (using 40 mm graded crushed stone aggregate) at pump house, floor mounting, dust and vermin proof, factory made (CPRI approved), fabricated out of 2 mm thick CRCA sheet suitable for 3 Phase, 415 Volt, 50HZ AC Supply, busbar chamber with aluminum busbar of suitable amp rating for 3 Phase and 4 wire system duly insulated with heat shrinkable sleeve as per colour, supported on epoxy insulator 01 set, common earth bus bars of 25mm x 4mm at bottom inside panel board with two earth terminal out side panel board, cable alley cable gland with independent plate at bottom and complete panel board painted with powder coating in grey colour all as specified & directed,The panel should be IS/IEC 61439-I- TTA. The Panel builder should submit Test Certificate along with GA drawing before executing the job. (Note: Panel shall be a front/rear opening with cable entry from the bottom). Make of panel- Indian Transformers & Electricals Pvt Ltd. Gurgaon, Legrand, Schnieder, L&T The panel shall comprise the following:-
(a) MCCB 60 Amps,thermal adjustable and magentic setting having rupturing capacity 36 KA (Ics= 100% Icu) , TP, 415 volts, 50 Hz, along with Extended Ratory handle ,Spreader terminal and phase barrier - 01 No. (b) Supply, installation, testing and commissioning of Soft Starter 20H.P. (c) Supply, installation, testing and commissioning contactors, relays, CT timers, for suitable rating having with ON, OFF , Trip Indicating Light, Push Buttons, Digital MFM along with contactor & semiconductor fuses with , Control Fuse etc fitted in Panel board for showing V, I, Hz, Pf all as specified and directed.
Supply and fixing in replacement “Lithium based Energy Efficient Integrated Solar Street Light of 24 Watt” incl hexagonal pole suitable for fixing in Single FRP body with duly Polyurethane coating (Camouflage color) , encases with Monocrystalline Solar PV Panel of 53/55Wp , Lithium Battery 11.1/12.8V, 28.6AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 12-14kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required. Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant. Make:- Axxon (AXN-24W) or equivalent in Bajaj /phillips/Halonix/Surya as approved.
Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Preparation of old painted surface not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Supply and fixing 80 mm thick M-40 Grade Machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006, jointed and pointed with grey cement and no pigment including 50mm thick sand cushioning and PCC lock at edges, complete all as specified and directed.
Supply and fixing in replacement 36 watt 2x2 panel Ultra modern recess mounting luminaire with high performance LEDs suitable for mounting with Armstrong/Grid ceiling delivers excellent illumination & comfort in high ceiling areas long life &photo biologically safe LED’s high performance electronic driver ensures zero maintenance no harmful UV & IR radiations environment friendly as it does not contain mercury instant light, High transmittance PMMA opal diffuser for glare free symmetric light distribution. Powered by an built-in electronic driver (SMPS based constant current supply) complete making connection and testing after fixing all as specified and directed by Engr-in-Charge. The specification of the panel light fitting should meet the following. (a) Housing of light fitting: CRCA Powder- Coated. (b) Operating voltage : 150V to 270V. (c) Operating temperature : 10 to 45 degrees. (d) Lumen efficacy : 110 lumen per watt. (e) System lumen : Not less than 3600 Lumens. (f) Colourtemperature : Not less than 5700K. (g) Surge voltage protection : Up to 2 KV. (h) Ingress protection : IP20. (j) Total harmonic distortion : Not less than 20%. (k) Power factor : Not less than 0.90. (l) Input frequency : 50 HZ. (m) Line protection : Under/Over voltage protection. Cat part No LM10-451-XXX-65-3G2 of Wipro, or its equivalent in Havells, GE, Oshram, Phillips”
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers to be used of same make/brand only and shall be deemed in to included in quoted rate only.)
One light point/fan /bell point controlled by one switch.
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
Material and labour for point wiring complete with 2.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 2.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers and all to be used of same make/brand only and shall be deemed in to included in quoted rate only.)
Modular type switch 6 Amps, single pole, 1way,1 module, 240V, ISI Marked Complete all as specified and directed. “Cat part No ACVSXXWO61 of Crabtree (Havells) or its equivalent in Anchor, Legrand, Seimens as approved”.
Modular type switch 16 Amps, single pole, 1way,1 module, 240V, ISI Marked Complete all as specified and directed. “Cat part No ACVSXXW161of Crabtree (Havells) or its equivalent in Anchor, Legrand, Seimens as approved”.
Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Marked Complete all as specified and directed. “Cat part No ACVKSWW063 of Crabtree (Havells) or its equivalent in Anchor, Legrand, Seimens as approved”.
Modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module with light indication ,240V,AC ISI Marked Complete all as specified and directed . “Cat part No ACVKCWW163 of Crabtree (Havells) or its equivalent in Anchor, Legrand, Seimens as approved”.
Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 50 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 70 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 95 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
Excavation in tranches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundation of laying cable including getting out in soft/loose soil complete all as specified and directed.
Returning filling in including spreading watering and well ramming in layers not exc 25 cm complete all as specifed .
Removing surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed .
M & L for laying of bricks well burnt sub class 'B' (Old pattern) laid flat for cable protection width equal to the length brick complete all as specified.
Sand cushioning to under ground cable, 8 cms thick before laying the cable and 15 cms thick after laying and stretching the cable in trenches including hand punning and consolidating, punned to 18cm thickness, complete all as specified and directed. Note : For payment purpose, only punned thickness shall be measured.
Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground leel, connecting to the Galvanised earthing lead strip 32x6mm size, by means of bolts, nuts, heck nuts and washers of galvanized iron and earth lead protected by provision of GI medium grade pipe 65mm bore incl provision of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt & charcoal filling, test point made out of 40mm x 8mm FI with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs, all as per electrical plate No 5 of SSR-1991 Part I and connected to earth test point all as specified or indicated incl testing on completion.
Surface excavation n exc 30cm deep and averaging 15 cm deep in any type of soil all as specified and directed.
Rolling and consolidating of soling of broken boulders not exceeding 15cm thick with power roller exc 5 tonne and nexc 8 Tonne all as specified and directed.
Hard core of Broken stone boulder of guage exc 63mm but n exc 100mm deposited, spread and levelled in layers n exc 15cm thick watered and rolled/rammed to a true surface all as specified and directed.
40mm thick plain cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregrate) as in floors , finishing surface even and smooth using extra cement all as specified and directed.
Supply and fixing of Double wall corrugated (DWC) HDPE tubing 65 mm bore for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates
Supply and fixing of Double wall corrugated (DWC) HDPE tubing 80 mm bore for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates
S&F in repair GI water tubing in replacement 15mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed.
S&F in repair GI water tubing in replacement 20 mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed.
S&F in repair GI water tubing in replacement 25mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed.
S&F in repair GI water tubing in replacement 40mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed.
S&F in repair GI water tubing in replacement 50 mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed.
S&F in repair GI water tubing in replacement 80 mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed.
Construction of valve pit of sizes 120cmx120cmx120cm (internal dimentions), brick construction, including all necessary excavation and earth work in hard/loose soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50m and depositing where directed, PCC in foundation of the mix (1:4:8), type D-2, (using 40mm graded crushed stone aggregate) brick masonry in cement mortar (1:4) rendering, 12 mm thick in cement mortar (1:4), internally, finished even and fair pointing flush externaly as the work proceeds in the same mortar, mild steel frame, MS sheet cover 5mm thick with handle and locking arrangement, painting all the exposed MS work with two coats of synthetic enamel paint of the tint as approved by the GE over a coat of red oxide primer and painting all the MS embedded in PCC with two coats of black bituminous paint complete all as specified.
Construction of brick masonary valve pit of size 90cm x 90cm x 90cm (Internal dimensions of chamber from top of PCC to bottom of cover) including excavation in any type of soil returning, filling around foundation and removal of surplus soil to a distance not exceeding 50m PCC 1:4:8 type D-2 in foundation brick work in cement mortar 1:6, 10mm thick plaster in cement mortar 1:4 to internal surface covered pit with MS sheet cover 3.15 mm thick with locking arrangement, handle fixing arrangement fixed on 40mm PCC 1:2:4 type B-1 coping and painting with oil paint two coat over a coat of red oxide primer complete all as specified and directed.
Taking down old unsv sluice valve and Supply and fixing ball valve having SS ball with both CI end flanged,ISI marked, with nuts,bolts and washers and rubber gaskets with stainless steel handle over PVC coating complete all as specified and directed for following bore pipe:-
150mm dia
100mm dia
80mm dia
50mm dia
Taking down old unsv Non-return value and Supply and fixing Non return valve heavy duty both ends flanged ISI marked complete with nuts, bolts washers etc complete all as specified and directed of following sizes:-
150mm dia
100mm dia
Taking out old unsv Ball valve and supply and fixing for ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete of sizes :- Make- BIR,Zoloto,leader as approved.
15mm bore of pipe
20mm bore of pipe
25mm bore of pipe
40mm bore of pipe
50mm bore of pipe
Supply and fixing Glow sign board made of acrylic sheet reactangular shape having lighting arrangement of superior quality of size 5'x2'x8" showing installation Nomenclature as approved marked all as specified and directed. Note: Installation line diagram to be enfaced will be approved by AGE E/M and no extra will be paid of any addition and alteration of words or marking of colours.
Fabrication of angle stand made of angle size 50x50x6mm for Glow sign board, incl jointing with Tees,incl PCC in 1:2:4 (Type B-1) as in blocks for embedding Angle all as specified and directed.
Surface dressing in hard/dense soil n exc averaging 15cm deep for cleaning the area by cutting the unwanted bushes/vegitation growth in and around the area of installations/around the valve pit chamber/along the pipe line route if required etc all as specified and directed.
narayan construction
M/s Mool Raj Ramesh Chander
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .