Executive Engineer PWD Howrah Electrical Division
Office of the Executive Engineer PWD Howrah Electrical Division Onkarmal Jetia Road Howrah 711103
Up gradation of electrical installation work at Election Section Building in Uluberia SDO office campus under Uluberia Electrical Sub-division.
2026_WBPWD_1009463_1
WBPWD/EE/HED/NIT- 28 (5th Call) of 2025-2026
Open Tender
ELECTRICAL WORKS ORG
Percentage
30 days
Uluberia SDO office campus under Uluberia Electri
Please refer Tender documents.
11 documents required · 11 mandatory
₹6,416
18 May 2026
18 Feb 2026
9 Mar 2026
19 Feb 2026
6 Mar 2026
25 Feb 2026
SUB HEAD 1: Internal EI Works
Supply and fixing 240V , 32 A DP with fuse on L&N Sheet steel Main Switches on flat iron frame on wall.( Make Havells) (AC-1, Light ckt-1)
Supply and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make- Legrand/Seimens/L&T))
2+8 way Enclosure (AC Ckt, raw power)
2+12 way Enclosure (Light ckt, raw with emergency power)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.
40 A, DP,(Legrand/Seimens/L&T)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.
6-32 A, SP, (Legrand/Seimens/L&T)
Supplying and fixing PVC Rigid Conduit 'FR' [PrecisionMake]on wall, ceiling with saddles and other accessories as required and mending good damages to building works .
20mm size
Distribution wiring in 1.1KV grade2x22/0.3(1.5sqmm)single core stranded 'FR' PVC insulated & unsheathed copper wire (Polycab/Mescab/Havells/RR) partly in 20mmsize PVC rigid conduit 'FR' (Precision make) [for ceiling portion only]and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical runembedded inwall], with1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/callbell points with Modular type switch (Legrand/L&T/ABB) fixed on Modular GI switch board complete with 2 no. suitable size “Ph&N” copper bar with top cover plate making earthing attachment fixed on wall incl.mending good damages to original finish.[only PVC Rigid Conduit on ceiling and remaining portion concealed]
Average run 8 mtr
On board
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Legrand/L&T/ABB), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Legrand/L&T/ABB) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Legrand/L&T/ABB) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Legrand/L&T/ABB), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, Modular type starter (Legrand/L&T/ABB) with 25A Modular switch type DP MCB (C Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying and Drawing 1.1KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. ( Make- Finolex, /KEI/Polycab/Havells)
3 x 22/0.3 (1.5 sqmm)
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
2x4 sqmm + 1x2.5 sqmm as ECC
2x6 sqmm + 1x4 sqmm as ECC For Light SPNDB from L shaped Building TPNDB)
4X10 sqmm + 2x6 sqmm as ECC (For AC SPNDB from L shaped Building TPNDB)
Cutting Channel of size(43mmx43mm) & (40mmx40mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25mm, 3mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8SWG incl.supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.
25 mm dia 3 mm thick polythene pipe without earth continuity wire
19 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works.
150 mm x 100 mm x 65 mm
175mm x 100 mm x 65 mm.
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required.
150 mm x 100 mm x 65 mm
175 mm x 100 mm x 65 mm
Supply & Delivery 240 Volt,50Hz,4 ft long , Max20 Watt,efficacy-100lm/w, PC body,Al housing Double LED Tube Light fittings complete with all accessories including LED Tube. [Make: PHILIPS /CROMPTON/ wipro or Manufacturer with own NABL accredited lab with valid test certificate ]
Supply & Delivery 240 Volt,50Hz,4 ft long , Max20 Watt,efficacy-100lm/w, PC body,Al housing Single LED Tube Light fittings complete with all accessories including LED Tube. [Make: PHILIPS /CROMPTON/ wipro or Manufacturer with own NABL accredited lab with valid test certificate ]
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG)supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & fixing of 9W LED Lamp B22 cap,CDL with angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. [Make: PHILIPS /CROMPTON/ wipro or Manufacturer with own NABL accredited lab with valid test certificate ] (For Godown loop in & Out)
Supply & Delivery of 240 Volt, 50Hz 65W, 200CMM, 400RPM 1200mm(48'') sweep ac ceiling fan. BEE star rated (Make -Crompton,Orient, Usha make & model approved by EIC)
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. Making necy. connections etc.
Supply & Delivery of 240 Volt, 50Hz ac Heavy Duty Exhaust fans ( Make-Crompton/orient/EPC ) 23 cm (9"),1400RPM
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter.
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long).
30 cm Exhaust fan (12")
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) as per GS.
Supply and Delivery of 450 mm sweep, full metal body wall bracket fan( make- orient/ crompton)
Fixing of wall fan by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. Length.
SUB-HEAD 2: COMPOUND LIGHTING SYSTEM
Supply and delivery of 240V AC, 70 Watt LED Street Light Fittings die cast aluminimum housing complete with all accessories lumen output:Min 120lm/w driver rating should be higher than the fittings rating.[Make: PHILIPS /CROMPTON/ WIPRO or Manufacturer with own NABL accredited lab with valid test certificate ] [For Compound light]
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
Supply and Fixing SMC Junction Boxes of dimension (250x200x105)mm with IP 67 protection (Sintex / Hensel )make for compound light fabricated With 1 no 4pole DMC 32A terminal stud and 1no 6A 10KA C curve SP MCB (make-Legrand/ABB/Siemens/L&T) Mounted directly on wall surface by suitable fastner. [N/S]
Supply & Delivery of one number 1.1 KV Grade 2 core 6 sqmm XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) conforming to IS: 7098 / 1988 with its latest amendment of following size. (Make: Gloster /Havells /Polycab /Mescab)
Laying of 2 core 6 sqmm cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
S&F of 2 core 6 sqmm compression type gland complete with brass gland, rubber rings for dust & moisture proof entry of PVC armoured cables as below as per G.S.
Finishing the ends of 2 core 6 sqmm cables by crimping method including S/F dowells solderless sockets, tapes and jointing materials etc. as per G.S.
SUB-HEAD 3: EARTHING
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
By ISI-Medium GI pipe
Excavation of soil for installation of Earth Electrode and filling & ramming
For Morrum Soil
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
No. 4 SWG
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
Charges for dismantling all existing DB,JB, Main Switches, Cables, Panels, GI Pipes Fans and Light Fittings etc carefully otherwise mending good damages anb deposited to office by challan as per direction of EIC.
ADD GST @ 18%
ADD LWC @ 1%
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.48 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.38 MB
BOQ_2478285.xls
BOQ • 2.03 MB
2911.pdf
Tender Documents • 1.86 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .