| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC 00 ITBAHRA GAUR KANIKAPUR ROAD KANIKAPUR BASTI UTTAR PRADESH 272163 | BASTI | UTTAR PRADESH | 272163 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹21.5 L+₹1.2 L (5.96%)Rejected-Finance | L2 | Rejected-Finance Quoted other than lowest rate. | |
| 3 | L3₹22.2 L+₹2.0 L (9.66%)Rejected-Finance 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Quoted other than lowest rate. | |
| 4 | L4₹28.7 L+₹8.5 L (41.8%)Rejected-Finance NA | NA | NA | 121004 | L4 | Rejected-Finance Quoted other than lowest rate. | |
| 5 | L5₹29.8 L+₹9.5 L (46.8%)Rejected-Finance | L5 | Rejected-Finance Quoted other than lowest rate. |
Tender Value
₹23.8 L
EMD Value
₹48,000
Closing Date
30 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH ASHOK KUMAR, EE, IDSE
GE NORTH BATHINDA MIL STN PIN-151001
ADDN/ALTN TO SEWAGE LINE AND CONNECTED ITEMS FROM BLDG No. P-10 AND CERTAIN MINOR WORKS UNDER AGE BR-III AND AGE E/M OF GE NORTH BATHINDA AT BATHINDA MIL STN
2022_MES_555150_1
8937/NIT-50/22-23
Open Tender
Civil Works
Item Rate
180 days
GE NORTH BATHINDA
Class E category a(i)
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹48,000
Yes
17 Jan 2023
29 Sept 2022
2 Dec 2022
29 Sept 2022
30 Nov 2022
17 Nov 2022
29 Sept 2022 - 8 Oct 2022
Amount
SCHEDULE 'A' B/R Works
Removing the manhole cover (CI or RCC) for opening of septic tank, soak wells, manholes or sewage wells (any type rectangular or circular) of any size and any capacity in foul condition and bailing out of mudy water, taking out semi solid sludge/solid contents/night soil from tank by manually or mechanically by sewage suction pump (at contractor's discretion) making it fully functional and cleaning the internal surfaces with water to the entire satisfaction of Engineer-in-Charge including all necessary tools and plants required for removal of all wastes, solid or liquid sludge from the site through closed container and depositing the sludge in a pit (at empty/open area) of suitable size at any distance upto 200 metres from the line/colony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork and refixing the manhole cover to its original position complete all as specified and as directed by Engineer-in-Charge. Note:- (i) All the tools and plants including mechanical pump, closed lorry and other allied arrangements for making septic tank clean and functional will be made available by the contractor without any extra cost to the Govt. (ii) The mode of measurement shall be considered 25% of the actual volume of septic tank/ manholes (contains human excreta and water). Cost for the dewatering/bailing out of mudy water shall be including in the unit rate(i.e. qty of solid sludge contents) nothing extra shall be paid on this account.
Excavation in trenches in soft/loose soil, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundations, shafts, wells, cess pits, manholes, sewerage pipe line, including getting out, including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge. Note:- Excavation will be done through JCB or any other machine for early and smooth functioning and excavation will be done manually in conjusted area where excavation can not continue by means of JCB or other machine cutting of grass, bushes, road, path etc. also included in this unit rate of item. Nothing extra shall be paid on this account.
Excavation in trenches in soft/loose soil, not exceeding 1.5 metre wide and exceeding 1.5 metre in depth but not exceeding 3.0 metre depth for foundations, shafts, wells, cess pits, manholes, sewerage pipe line, including getting out, including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge. Note:- Excavation will be done through JCB or any other machine for early and smooth functioning and excavation will be done manually in conjusted area where excavation can not continue by means of JCB or other machine cutting of grass, bushes, road, path etc. also included in this unit rate of item. Nothing extra shall be paid on this account.
Excavation in trenches in soft/loose soil, not exceeding 1.5 metre wide and exceeding 3.0 metre in depth but not exceeding 4.5 metre depth for foundations, shafts, wells, cess pits, manholes, sewerage pipe line, including getting out, including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge. Note:- Excavation will be done through JCB or any other machine for early and smooth functioning and excavation will be done manually in conjusted area where excavation can not continue by means of JCB or other machine cutting of grass, bushes, road, path etc. also included in this unit rate of item. Nothing extra shall be paid on this account.
Returning/filling in including spreading, leveling, watering & well ramming in layers not exceeding 25 cm thick each, complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated material to distance not exceeding 50 metre above the starting point, complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from building and thrown in low laying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material & labour for cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate for foundations, fillings & mass concrete, sub base, plinth protection, complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size bricks (old serviceable bricks obtained from demolition/dismantled item shall be reused ) straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Demolition and breaking up drain pipes SGSW, AC or reinforced concrete pipe upto and including 150 mm bore pipes, complete all as specified and directed by Engineer-in-Charge.
Material & labour for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate to drain pipe including packing under & hunching against the sides of pipe 150/200 mm dia ( internal) after they are laid and tested in trenches, complete all as specified and directed by Engineer-in-Charge.
Material and labour for 150mm bore (internal dia) salt glazed stone ware (SGSW) drain pipe, grade ‘A’, laid on concrete bed to required slope in trenches, jointing with packed spun yarn and in cement and sand mortar (1:1) and tested complete all as specified and directed by Engineer-in-Charge. (Note : Excavation, earrh work and concrete bed shall be measured and paid separately under appropriate item of BOQ.)
Material & labour for cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for manhole benching, flooring and coping, complete all as specified and as directed by Engineer-in-charge.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for 15 mm thick cement plaster in CM 1: 4 on fair / unfair faces of brick work or concrete surfaces finished even & smooth without using extra cement, complete all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete reinforced of any discription and in any position, including reinforcement cut as required to facilitate and including removing rubbish material from site and thrown in low laying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-charge
Material & labour pre-cast RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates as in pre-cast manhole cover slabs of any thickness, size or shape including all necessary form work, finishing concrete surface fair & even and set in CM 1:4, including demolition of old cover, complete all as specified and directed by Engineer-in-Charge.
Material and labour for mild steel TMT bars 6 mm to 8mm dia cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Supply and fixed mild steel work in rungs, hooks, handels, manhole covers, hold fast & small articles, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement SFRC (Steel fibre reinforced concrete) cover and frame (heavy duty HD-20 grade designation) size of cover 0.70 x 0.70 mtr confirming to IS 12592 fixed in cement cocrete (1:2:4) including old broken cover remove from site complete all as specified and directed by Engineer-in-Charge.
Material and labour cutting into existing manholes/septic tank for connecting new drain upto 150mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round to 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished, and reforming benching as required complete all as specified & directed by Engineer-in-charge.
Supply and laying DWCPE (SN8) drain pipes 200mm inner dia as per IS-16098 (Part-II), laid in trenches on and including moorum bed to required slope, including all accessories/fittings/jointing ring, jointing and tested complete all as specified and as directed by Engineer-in-Charge. Make :- Rex Polyextrusion Limited/Dura line/ Alom Poly Extrusions Ltd/Jain Irrigation/Kamboj Polythene Ltd Ludhiana/Aspra Industries Delhi (Note : Excavation & earth work shall be measured & paid separately under appropriate item of this BOQ)
Excavation in post holes in soft/loose soil not exceeding 0.50 Cum each, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm including removing of surplus spoil to a distance not exceeding 50 metre and making good the disturbed surfaces, complete all as specified and directed by Engineer-in-Charge.
Material and labour for PCC (1:3:6), type C-1 using 20 mm graded stone aggregate as in copings, post holes, foundations, filling, mass concrete, side kerb, haunching, packing around and interlocking paver blocks, filling back of PS chowkhats/frame, bed blocks to hold past etc., including necessary form work complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair, Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Material and labour for mild steel work as in tubular ( round/square/rectangular shape of pipes as approved by Engineer-in-Charge) trusses, purlins, rafter, MS plates, connecting plates, including post special shaped washers etc., complete including necessary nut bolts, wind ties and gusset plates etc., using ERW or induction butt welded tubes conforming to latest relevant IS grade St-240, complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
Material and labour for PCC ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 5mm thick in cement mortar (1:3) on any face of ceiling, finished fair and even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Make : Dr Fixit/Fosroc/BASF/STP
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down or by sand papering or by any other mean and after preparing the surfaces applying two coats of white wash complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparing newly plastered or concrete surface of ceiling by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other means, and preparing the surfaces smooth by applying white cement based putty to make the surface even and smooth by using sander machine (with provision of dust sucking) upto entire satisfaction of Engineer-in-charge, and after preparing the surfaces applying two coats of oil emulsion distemper (washable), as approved tint/colour by using paint roller brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other means, and preparing the surfaces smooth by applying two coat of weather coat /apex paint (exterior emulsion) of approved tint over a coat of exterior emulsion primer, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls/pillars/cornices by scraping down with using mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming and washing down and preparing the surfaces smooth and after that applying two coats of weather proof exterior emulsion paint (wheather coat Apex, 100% exterier grade) by using paint roller brush or electric paint spray machine, as per existing or as approved tint/colour complete all as specified and as directed by Engineer-in-Charge. NOTE : - Complete removal /scraping to old existing treatment as directed by Engineer-in-charge, each stage i.e after complete removal and before applying weather coats as specified above, the surface shall be passed in writing by the Enigineer-in-charge.
Material and labour for preparation of old decorated surfaces (plastered/unplastered) of walls/pillars /cornices by removing / scraping down all loose particle, smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc with using broom / steel patti / wire brush / sand papering or by any other mean, including applying one coat of alkaline resistant primer and to make the surface even and smooth and also using sander machine (with provision of dust sucking) on uneven surface to make the surface even and smooth (before and after applying putty as per site situation) upto entire satisfaction of Engineer-in-charge, and after preparing the surface smooth applying two coat of oil bound distemper (washable) by using electric paint roller or roller brush, as per existing or as approved tint/colour complete all as specified and as directed by Engineer-in-Charge.
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Glazed ceramic coloured tiles of size 350mmx 250mm / 450mmX 350mm// 450mmX 300mm, 7mm to 8mm thick, as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick (Av thickness) bedding layer (rendering) in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Supply and fixing in repair stop valve/angle valve cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing in repair concealed stop cock cast copper alloy, chromium plated, fancy type, long shank and cup, screwed both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of stop valve/stop cock shall be as given in SSR or in relevant IS.
Supply and fixing bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing in repair bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply & fixing in repair 600 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Supply and fixing 10 litres capacity PVC valveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handle including brackets and 32mm dia PVC bend long type ( flush pipe) complete all as specified and directed by Engineer-in-Charge.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and fixing ball valve and gate valve including dismantling/taking down of existing unserviceable PVC water storage tanks of any description complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Dismantling cast iron drain pipes, jointed in cement mortar of any description any dia from wall and taking out from trenches including all fittings (bend, trap, cowl, branch piece etc) and removing from the site complete all as directed by Engr-in-Charge.
Material & Labour for 75mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed to wall with stack clamps (interval of 1m) made out of FI 50x5mm and 16mm dia round iron stay including nut bolt and jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed to wall with stack clamps (interval of 1m) made out of FI 50x5mm and 16mm dia round iron stay including nut bolt and jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, laid in trenches or in floor jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Cast iron floor trap 100mm bore, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Cast iron trap 100mm bore, P or S complete all as specified and as directed by Engineer-in- charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed ) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed ) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Material and labour concreting bed to drain pipe including packing under and hounching against the sides of pipes after they are laid and tested in PCC 1:4:8 type D-2 for 150mm bore pipe, complete all as specified and as directed by Engineer-in- charge.
Material and labour PVC(SWR) pipes, single socketed, in any length, with rubber rings 110mm dia laid in trenches & jointed, complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in repair Soap dish, vitreous China white, approximate size approximate size 160mmx160mmx90mm, including fixing to wall with CP screws and PVC plug complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair brass chromium plated tubular towel rail 20mm dia 'D' type, 600mm long between flanges fixed to plug , bracket with chromium plated brass screws, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing grating doom 125mm dia with waste hole of PTMT (minimum weight 40 gms), complete all as specified and as directed by the Engineer-in-Charge.
Demolition of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for vitrified ceramic coloured tiles (dark shade, jointless) 8 to 10 mm thick square or rectangular area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for vitrified ceramic coloured tiles (dark shade, jointless) 8mm to 10mm thick square or rectangular (same as floor tile, as per above item ), as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Dismantling brick/PCC terracing tiles single layer in roof laid and pointed in cement mortar and removing/disposal off from the site complete all as specified and as directed by Engineer-in-charge.
Demolition of mud in roofs, any thickness, including plastering and leaping (whether full thickness removed or only a part there of) including removing/cutting uprooting grass, vegetations and roots of small plants etc on roof floor and surrounding/parapit wall etc, including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for cleaning surface of roof, including flashing and junction of parapets etc. by wire brushing, removing all dust and washing with water and preparing to receive rendering, after preparing that applying 15mm thick screed /rendering in cement mortar (1:4) including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg on existing concrete surfaces of roof and finished even and smooth without using extra cement (prepare smooth surface to receive APP based polymeric waterproofing membrane ) complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only and APP membrane shall be measured & paid separately as Material and labour)
Material and labour for applying one coat of solvent based/cold applied bituminous primer at the rate of 400 ml per sqm on cleaned & leveled screed/plastered surface of roof complete all as specified and as directed by Engineer-in-charge.
Supply and fixing minimum 3 mm thick APP based polymeric waterproofing membrane (minimum weighing 3kg/Sqm), reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm), laid on primed surface by forced application, torching with overlaps as recommended by the manufaturer complete all as specified and as directed by Engineer-in-charge. NOTE:- (i) The work to be carried out by authorised applicators of material manufacture. Name of applicator shall be approved by GE on recommendation of AGE
Material and labour for lime concrete terracing using brick aggregate and surkhi as specified in clause 11.11 and laying as specified in clause 11.27 of MES Sch Part-I (2009) minimum thickness at edge 40mm and increasing uniformly towards ridges to obtain a chain slope 1:40, the top shall be trowelled with the addition of jaggery solution and finished smooth complete all as specified and as directed by Engineer-in-charge.
Material and labour for 40mm thick brick tiles laid/bedded on screed bed 15mm thick in cement mortar (1:6), on existing lime concrete surfaces of roof, joints grouted flush in cement mortar (1:3) mixed with liquid WPC @ 200ml per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and as directed by Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for 40mm thick brick tiles (old serviceable tiles obtained from demolition/dismantled item shall be reused) laid/bedded on screed bed 15mm thick in cement mortar (1:6), on existing lime concrete surfaces of roof, joints grouted flush in cement mortar (1:3) mixed with liquid WPC @ 200ml per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and as directed by Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for PCC tiles (type A1) of size 25cm x 25cm x 22mm thick with grey cement and no pigment, factory casted (made by using PVC/Rubber moulds on Vibrating Table Machine or machine pressed, top surface even and smooth); laid/bedded on screed bed 15mm thick in cement mortar (1:6), on existing lime concrete surfaces of roof, joints grouted flush in cement mortar (1:3) mixed with liquid WPC @ 200ml per bag of cement of 50kg, complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames, wooden/PVC doors/steel ventilator) area not exceeding 1.50 sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 4 mm thick sheet glass ordinary quality in squares exceeding 0.5sqm in each pane complete all as specified & directed by Engineer-in- charge.
Supply & fixing, solar control film 25 micron reflective type (gareware sun control or equivalent) pasting on glass duly air bubble free complete all as specified & directed by Engineer-in- charge.
Supply and fixing extruted aluminium alloy handle fabricated type anodised 150mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 200mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 150mm long complete all as specified & directed by Engineer-in-charge.
Supply & fixing mild steel 4 lever mortice lock vertical type 100mm size with original and duplicate key complete all as specified and directed by Engineer-in-Charge.
Supply & fixing 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and directed by Engineer-in-Charge.
Material and labour for mild steel work conforming to Fe-290 (Gde E-165) as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, walkways, railing, framed work of water tanks and similar works complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 3mm thick sheet glass ordinary quality in squares not exceeding 0.5sqm in each pane (for new door/window) and fixed in any type of doors/windows/ventilators with wooden bead/pin tacked/with oil putty etc. as required or as directed including cutting of glass as per site requirement complete all as specified & directed by Engineer-in- charge.
Supply & fixing galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staples complete all as specified & directed by Engineer-in- charge.
Supply & fixing in repair galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staples including taking out old broken wire cloth any size complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement vitreous china wash down water closet pan (pedestal pattern, EWC) white colour (excluding flushing cistern and flush pipe) including connection to drain and to flushing pipe anti syphonage etc., including plastic water closet seat with cover (white colour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in replacement cromium plated shower rose 125mm size, with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair single lever brass CP wall mixer valve 15mm bore, brass (cast copper alloy) chromium plated, mixer for mixing hot & cold water suitable for WHB or fixed to wall, screwed down for iron pipe 15mm bore complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of mixer valve shall be as given in SSR or in relevant IS.
Supply and fixing sheet glass shelf assembly of size 60cm long, 12cm wide and 5.5mm thick glass shelf, including chromium plated bracket guard railing, fixed on wall with chromium plated catcher brackets, brass screws and PVC plug complete all as specified and as directed by Engineer-in-charge.
Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using sanded paper, clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints for drain or rain water fixed along walls with stack clamps made out of FI 50x5mm and 16mm dia round iron stay (interval of 1m) including nut bolt and PCC work, including dismantling/taking down old pipe complete all as specified and as directed by Engineer-in- charge.
Material and labour 18-20mm thick machine cut, granite duly factory grinding and polished (table rubbed and polished) of approved colour for counter sunk wash basin, plateform/cooking plateform or as directed, including screed bed 15mm thick in cement mortar (1:4) (grey cement slurry) including pointing in white cement (1:2) using marble dust with admiture of pigment to match with shade of granite stone slab including cutting as required including cleaning and extra polishing if required complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing aluminium anodised frame, made out of aluminium section weighing 0.98 Kg/mtr, powder coated (minimum thickness of powder coating not less than 50 micron), for doors, windows, ventilators with one or more rebate including jointing cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge. Note :- If aluminium section used other than above mentioned weighing then weight of each section shall be physically ascertained through a board of officers convened by Accepting officer and payment shall be made only after the actual weight at site.
Supply & fixing anodised aluminium door shutter, made out of aluminium section weighing 0.55 Kg/mtr, powder coated (minimum thickness of powder coating not less than 50 micron) including aluminium hardware i.e. necessary joining cleats, glazing clips, rubber neoprene packing, suitable size of aluminium handles 2 Nos and aluminium hinges 04 Nos in each leaf (size of handle and hinge as directed), anodised aluminium snap beading, screws etc., complete all as specified and directed by Engineer-in-Charge. Note :- (i) Aluminium chowkhat frame shall be measured and paid separately under appropriate item of BOQ. (ii) Glass and other filling material in panels shall be measured and paid separately under appropriate item of BOQ.
SCHEDULE 'A' E/M Works
Taking down carefully copper/aluminum point wiring (light, fan, socket or power point) complete including fittings such as hylum sheet, switches, ceiling rose, pendent holder, sockets, regulator, etc but except concealed conduit, sunken boxes and junction box etc complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for point wiring with multi stranded copper conductor FRLSH cable, 1100 volts grade PVC insulated and unsheathed of size 1.5 Sqmm single core in and including PVC concealed conduit not less than 20mm dia (medium duty ISI marked) and conduit fittings with and including 3mm thick bakelite laminated sheet top cover for one fan/light controlled buy one switch including provision of 1.5 Sqmm PVC insulated & unsheathed with single core, multi stranded copper conductor FRLSH cable earth wire to common earth & connecting to earth dolly all as specified and directed.
All as per item No 107 here in before but for socket outlet 3/5 pin 5/6 Amp 250 Volts on same board, complete all as specified and as directed by Engineer-in-Charge.
All as per item No 107 here in before but for socket outlet 3/5 pin 5/6 Amp 250 Volts on independent board but not below the switch board, complete all as specified and as directed by Engineer-in-Charge.
All as per srl items No. 107 here-in-before but for 3/5 pin 15 Amp socket out let by using 2.5 sqmm PVC insulated unsheathed copper conductor cable FR-LSH multi strand on independent board including provn of 2.5 sqmm unshearhed, multi stranded copper conductor cable FR-LSH continues as earth wire connecting to earth dolly etc. complete all as specified and directed by Engineer-in-Charge.
All as per item No 107 here in before but for one light point controlled by two two way switch, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement modular switch, single pole, one way, 5/6 Amps ISI mark, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement modular Socket outlet multipurpose, 2 in 1, 5 pin, 5/6 Amps, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement modular switch, single pole, one way, 15/16 Amps ISI mark, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement modular Socket outlet multipurpose , 2 in 1, 5 pin, 15/16 Amps, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement modular switch, single pole, two way 5/6Amps, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing modular bell push 5/6Amps, 1 module, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface type polycarbonate, isolated body two to three terinal,, tpline series 20 x 50mm, 6 Amps, three terminal, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing lamp holder PVC/Polycarbonate cased body of brass with back plate suitable for batten fittings complete including 9w LED bulb, complete all as specified and as directed by Engineer-in-Charge. Make of holder : Anchor/Havells/Legrand/Indoasian/SSK and Make of LED bulb :- Crompton/Philips/Bajaj/Havells
Supply and fixing stepped type (1-4), electronic Fan regulator (two module), 120 watt, 250 volts, fixed on laminated sheet suitable for ceiling fan complete all as specified by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ).
Supply and fixing in replacement electric calling Bell Ding Dong type, AC 230 Volts single pole including making elctric connection and testing, complete all as specified and as directed by Engr-in-charge.
Supply and fixing of wall mounted Retro LED 20 watt, Batten decorative type, appx 4 feet long, pre wired including LED tube light 20W, 6000K with inbuilt driver complete fitting and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector, including taking down old unserviceable light fittings any type, complete all as specified and as directed by Engineer-in-Charge. Make - Cat part No. LT8-20-865-2 of Crompton/Havells/Wipro/Philips
Supply and fixing LED mirror light fiting 9/10 watt, 6000K, lineer & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete fitting with lamp and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector, including taking down old unserviceable light fittings any type, complete all as specified and as directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Supply and fixing bed side lamp bi-directional type pre wired with LED suitable capacity 7 watt, including taking down old unserviceable light fittings any type, complete all as specified and as directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Supply and fixing wall mounted/surface mounted decorative wall light fixture in cylendrical/doom profile made up of polycarbonate for and including LED 7 watt lamp, base B22 complete fitting with LED lamp and all other fixing accessories including electric connection connecting with using flexible copper wire twin core including taking down old unserviceable light fittings any type, complete all as specified and as directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Supply and fixing of new generation energy saving & environmental friendly long life versatile Pressue die cast aluminium housing, heat resistant glass, energy saving, IP-66 protection, better optics for uniform distribution street/Roadway luminaire with high power LED 25/35 Watt compete fitting with driver, LED strip and all other accessories etc. suitable GI bracket and making electric connection with using twin core copper cable of suitable size , including taking down old unserviceable light fittings any type, complete all as specified and as directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) VTPN, 6 Way 415V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, and including making good disturbed surfaces of walls as necessaty , including taking down old unserviceable DB, complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of MCCB of capacity 100 Amp, FP, 415 volt, short circuit breaking capacity not less than 16KA , thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, including thimbles, nuts, bolts, washers etc , MCCB fixing in new DB or the existing DB/Panel including making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge . Note :- DB shall be measured and paid separately under appropriate item of BoQ
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 8 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, and including making good disturbed surfaces of walls as necessaty, including taking down old unserviceable DB, complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB SPN 40-63 Amps, 10 KA 'C' curve 230 V AC, 50 Hz including necessary attachment, including taking down old unserviceable MCB SPN, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB SP suitable for 230 volts AC supply 6 to 40 Amps, SP rupturing capacity not less than 10KA, C Curve ISI Marked, 1 Module, including taking down old unserviceable MCB SP, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLSH, cable of 2 run 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth wire unsheathed, multi stranded, copper conductor FRLSH, drawn through new rigid PVC concealed conduit. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length, including taking down old unserviceable wiring, complete all as specified and as directed by Engineer-in-charge.
Taking down ceiling fan complete from site and kept safe custody and painting existing colour after completion of building repair work refix the same location, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing exhaust fan, steel body, 300 mm sweep (BEE, 5 star rated) with louvres, 230V, single phase AC supply, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Make - Usha / Bajaj / Khaitan / Orient / Crompton / Polar Note :- (i) Srl Number of exhaust fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Exhaust fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account
Taking down existing geysers from site before the building tiles/plastering and refix the same after completion of tiles/plastering work including painting of geysers and fixing arrangements and testing of required for proper functionality and including electric/earth connection and carrying out grouting and complete installation with mounting bolts, nuts including testing after installation, complete all as specified and directed by Engineer-in-Charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6.3mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I), complete all as specified and and as directed by Engineer-in-charge.
Supply, laying, jointing and testing XLPE LT Cable of size 50 Sqmm, 4 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I), laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling, complete all as specified and as directed by Engineer-in-charge. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed by Engineer-in-Charge. (Note :- For measurement purpose puned thickness shall be measured and paid i.e 18cm.)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing/laying GI tubing, light grade, 40 mm bore for protection of cable or earthing lead wire under hardstanding/fixed along poles/wall, laid in in trenches etc., complete all as specified and as directed by Engineer-in-Charge.Charge.
RAKESH KUMAR GARG & CO.
SHARDA ENTERPRIES
M/S GOYAL BUILDERS
K L JINDAL AND CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .