Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LQualified 2 3 AMIT VIJAY APT CHSL KASTURBA CROSS ROAD NEAR BHANU PARK KANDIVALI WEST MUMBAI 400 067 | MUMBAI | MUMBAI | MAHARASHTRA | 400067 | ₹1.2 L | L1 | Qualified MSE, MII, Category: General |
| 2 | L2₹2.3 LQualified MUMBAI MAHARASHTRA 400072 INDIA UDYAM MH 18 0002379 27AAECC7778G1Z9 R M MSME STATUS AS VERIFIED | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | ₹2.3 L | L2 | Qualified MSE, MII, Category: General |
| 3 | L3₹2.5 LQualified 849 1 BADDI SHITALPUR INDUSTRIAL AREA BADDI DISTT SOLAN HP | SOLAN | HIMACHAL PRADESH | 171102 | ₹2.5 L | L3 | Qualified MSE, MII, Category: General |
| 4 | Disqualified E 2 MANALI ARCADE PUNE SATARA ROAD PARVATI NEAR D MART PUNE MAHARASHTRA 411009 UDYAM MH 26 0849600 | PUNE | MAHARASHTRA | 411009 | - | - | Disqualified MII |
| 5 | Disqualified | - | - | Disqualified MSE, MII, Category: OBC |
Tender Value
₹2.9 L
EMD Value
Exempted
Closing Date
2 Mar 2026, 1:00 pmClosed
Visual inspection and photography performing a visual survey of the building and recording maping on drawing to assess extent of spelled concrete cracked concretehoney combing
Ultrasonic pulse velocity test for RCC structure in accordance with IS 516 Part 5 2018 SECTION 1 by portable ultrasonic non destructive digital test equipment
Rebound hammer test Rebound hammer test in accordance with IS 516 Part 5 2018 SECTION 4 by portable rebound hammer equipment
Core test Core cutting and compression test for RCC structure in accordance with IS 516 on RCC members 70 mm core cutting in reinforcement concrete core filling
Reinforcement mapping Reinforcement mapping test on RCC structure to assess covers spacing bars including approximate diameter
Chemical test for RCC structure in accordance with IS 456-2000 i Determination of PH value ii Determination of water soluble suphates iii Determination of water soluble chlorides content
Half cell potential test for RCC structure in accordance with IS 516 Part 5 2018 SECTION 2 half cell potential to assess the probality of corrosion of reinforcement
Carbonation test for RCC structure in accordance with IS 516 Part 5 2018 SECTION 3 carbonation test to measure extent of carbonation from the concrete surface at strategic locations
To check confirm present status of structure on basis on NDT results visual inspection
To provide recommendation for structure repairs and technical specification Preparing bill of quantities for the repair etc All as specified and directed
Vetting of report from IIT NIT
8999184
GEM/2026/B/7250722
Two Packet Bid
Visual inspection and photography performing a visual survey of the building and recording maping o
Maharashtra; Mumbai, Maharashtra; Mumbai; Mumbai
Total value wise evaluation
BOQ
6 documents required · 6 mandatory
2 yrs
₹1 L
₹2 L
40%
Exempted
Yes
2 Mar 2026
20 Feb 2026
2 Mar 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Visual inspection and photography performing a visual survey of the building and recording maping on drawing to assess extent of spelled concrete cracked concretehoney combing | Visual inspection and photography performing a visual survey of the building and recording maping on drawing to assess extent of spelled concrete cracked concrete,honey combing,reinforcement corrosiondelaminated concrete etc taking photographs and videos to collect evidence of damage to structure | 1 | Nos | Ultrasonic Pulse Velocity Test Mumbai For RCC Structure In | 15 |
| 2 | Ultrasonic pulse velocity test for RCC structure in accordance with IS 516 Part 5 2018 SECTION 1 by portable ultrasonic non destructive digital test equipment | Ultrasonic pulse velocity test for RCC structure in accordance with IS 516 Part 5 2018 SECTION 1 by portable ultrasonic non destructive digital test equipment including chipping out plaster at strategic locations | 10 | Nos | Rebound Hammer Test Rebound Mumbai Hammer Test In Accordance | 15 |
| 3 | Rebound hammer test Rebound hammer test in accordance with IS 516 Part 5 2018 SECTION 4 by portable rebound hammer equipment | Rebound hammer test Rebound hammer test in accordance with IS 516 Part 5 2018 SECTION 4 by portable rebound hammer equipment at strategic locations | 10 | Nos | Core Test Core Cutting And Mumbai Compression Test For R | 15 |
| 4 | Core test Core cutting and compression test for RCC structure in accordance with IS 516 on RCC members 70 mm core cutting in reinforcement concrete core filling | Core test Core cutting and compression test for RCC structure in accordance with IS 516 on RCC members 70 mm core cutting in reinforcement concrete core filling by specialised epoxy material micro concrete with bond coat at strategic locations | 5 | Nos | Reinforcement Mapping Reinforcement Mumbai Mapping Test | 15 |
| 5 | Reinforcement mapping Reinforcement mapping test on RCC structure to assess covers spacing bars including approximate diameter | Reinforcement mapping Reinforcement mapping test on RCC structure to assess covers spacing bars including approximate diameter at strategic locations | 5 | Nos | Mumbai | 15 |
| 6 | Chemical test for RCC structure in accordance with IS 456-2000 i Determination of PH value ii Determination of water soluble suphates iii Determination of water soluble chlorides content | Chemical test for RCC structure in accordance with IS 456-2000 using ready made kits and reagents Sample collected will be from half cell carbonatin powder i Determination of PH value ii Determination of water soluble suphates iii Determination of water soluble chlorides content at strategic locations | 5 | Nos | Half Cell Potential Test For Mumbai RCC Structure In Accordance | 15 |
| 7 | Half cell potential test for RCC structure in accordance with IS 516 Part 5 2018 SECTION 2 half cell potential to assess the probality of corrosion of reinforcement | Half cell potential test for RCC structure in accordance with IS 516 Part 5 2018 SECTION 2 half cell potential to assess the probality of corrosion of reinforcement at strategic locations | 5 | Nos | Mumbai | 15 |
| 8 | Carbonation test for RCC structure in accordance with IS 516 Part 5 2018 SECTION 3 carbonation test to measure extent of carbonation from the concrete surface at strategic locations | Carbonation test for RCC structure in accordance with IS 516 Part 5 2018 SECTION 3 carbonation test to measure extent of carbonation from the concrete surface at strategic locations | 5 | Nos | To Check Confirm Present Mumbai Status Of Structure On Basis | 15 |
| 9 | To check confirm present status of structure on basis on NDT results visual inspection | To check confirm present status of structure on basis on NDT results visual inspection | 1 | Nos | To Provide Recommendation Mumbai For Structure Repairs | 15 |
| 10 | To provide recommendation for structure repairs and technical specification Preparing bill of quantities for the repair etc All as specified and directed | To provide recommendation for structure repairs and technical specification Preparing bill of quantities for the repair etc All as specified and directed | 1 | Nos | Mumbai | 15 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_8999184.pdf
GEM_BID
boqpdfkohli_2026-02-17-13-27-07_7a6f908dbcd39cf4d33d0076f9b0779d.pdf
BOQ
structuralboq_2026-02-17-13-27-07_3ba7a3ebba3e4d3760415df9c2e022d7.csv
BOQ
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
GEM_OTHER • 0.52 MB
gtc.pdf
GEM_OTHER • 0.70 MB
Download all tender documents and submit your bid