Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 LAccepted-AOC NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹4.2 L+₹34,306 (8.83%)Rejected-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L2 | Rejected-AOC Not being the lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Not meeting NIT conditions being unenlisted contractor | |
| 4 | Rejected-Technical LOKMAT BHAWAN A WING 808 WARDHA ROAD RAMDASPETH NAGPUR 440010 | NAGPUR | MAHARASHTRA | 440010 | - | Rejected-Technical Reflected as NO in WLR |
Tender Value
₹4.5 L
EMD Value
₹8,980
Closing Date
27 Jan 2025, 6:00 pmClosed
AGE (I) AF Sonegaon, Nagpur
Bldg P-51, 44 Wings AF Station Sonegaon, Nagpur-440005
REPAIR/ MAINT OF SECURITY AND STREET LIGHTS IN TECHNICAL AND DOMESTIC AREA AT AFS SONEGAON, NAGPUR
2024_MES_691023_1
8541/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Sonegaon
As per NIT
8 documents required · 8 mandatory
₹300
AGE (I) AF Sonegaon
₹8,980
Yes
6 Mar 2025
30 Dec 2024
3 Feb 2025
30 Dec 2024
27 Jan 2025
13 Jan 2025
30 Dec 2024 - 6 Jan 2025
Amount
Taking down carefully old tube light/MH/HPSV Light fitting , 70/80/150/250/400 watt, unserviceable LED Street light fittings carefully from towers and upto 10 meter poles, after disconnecting the supply, sealing the cable ends for carrying out repairs/maintenance at site/workshop complete all as specified and directed. Note : (i) Spares required for repair of the fitting shall be measured and paid seperately under the item No. 2 here in after as "Supply only". However, the labour cost for taking down spares & fixing shall deemed to be included in the quoted rate. (ii) Unserviceable spare parts shall be contractor's property as per Sch of Credit.
Supply only the spares required for replacement of spares during the process of repair of the light fitting vide SI item No 1 here in before complete all as specified and directed.
(a) LED fittings 70 watt driver
(b) LED fittings 80 watt driver
(c) LED fittings 150 watt driver
(d) LED fittings 200 watt driver
Taking down carefully old security light/MH/HPSV Light fitting , unserviceable LED building security light fittings 20 watt carefully from towers and upto 10 meter poles, after disconnecting the supply, sealing the cable ends for carrying out repairs/maintenance at site/workshop complete all as specified and directed.
Supply only the spares LED fittings 20 watt driver required for replacement of spares during the process of repair of the light fitting vide SI item No 3 here in before complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of poles, stays, laying of UG cable/ pipes & getting out in soft/loose soil complete all as specified and as directed.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
M & L for providing dry river sand as in sand cushioning for underground cable protection including punning down sand in layers complete all as specified & directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supplying and laying common burnt clay sub class ‘B’ bricks of size 230 mm x 115 mm x 75 mm, laid perpendicular to axis of cable for protection of LT cables complete all as specified and directed.
M & L road cutting of size 30 cm width x 45 cm depth for laying of cables including making good the road with necessary returning filling and bituminious portion with concrete and bituminous mixture and cemented portion with PCC in 1:2:4 , 15 cm thick from top and matching with the existing surfaces complete all as specified and directed.
Supplying and laying GI pipe Light grade (ISI marked) 50mm bore with connecting accessories, laid under road/ drain/fixed on wall etc for protection of cables including taking down complete all as specified and directed
Supplying, laying, testing and Commissioning cable XLPE insulated aluminium conductor,stranded, armoured, PVC sheathed, LT 1100 volt grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ poles including taking down existing cables complete all as specified and directed for the following sizes.
50 sqmm, 3.5 core
25 sqmm, 3.5 core
16 sqmm, 4 core
10 sqmm, 2 core
S&F LED street light fittings with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 70 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed.
S&F LED Flood light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 200 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed.
S&F LED Flood light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 80 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed.
S&F LED industrial movable rectangular LED high bay with excellent heat sink along with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 150 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed.
Rectification of cable faults including provision of straight through cable joint LT Epoxy complete with resine and hardner for cable of size 70 Sqmm 3.5 core complete all as specified and directed Make:- M-Seal / Denson / Raychem / Cabseal
All as per Item No 17 here in before but of size 95 Sqmm 3.5 core.
All as per Item No 17 here in before but of size 35 Sqmm 3.5 core.
All as per Item No 17 here in before but of size 25 Sqmm 4 core.
M & L for painting of Steel tubular poles of any size with two coats of aluminum paint including painting to cross arms and clamps etc including preparation of surfaces by scrubbing and cleaning with wire brush and renumbering the existing number of the pole as existing complete all as specified and directed.
M & L for scrapping down rusted, fallen paint from the Electrical LT panel including rail/channel of base using mechanical scrapers, brushes, sand paper etc and removing the old paint on entire outer surfaces and repainting external surfaces with black/yellow (strip) colour with applying a coat of red oxide zinc chrome primer on the both internal & external portion where base metal is exposed, painting spray one coat of synthetic enamel paint for outdoor type panel including MCCB's specific cabinet complete all as specified and directed.
M & L for writing Pole No on PCC/steel poles with white synthetic enamelled paint on black background, size of letter shall be 50 mm or less complete all as specified and directed.
S&F in repairs Isolator TPN 415 volts 63 Amp AC with necessary connection in existing panel/DB BOX complete all as specified and directed.
S&F in repairs Isolator DP 240 volts 40 Amp AC with necessary connection in existing panel/DB BOX complete all as specified and directed.
S&F in repairs MCCBs four pole 415 volts. 16 KA ,100 Amp AC in existing panel board with modification /fabrication of existing panel board as directed by E-in-Charge complete all as specified and directed.
S & F Thermo plastic cable looping boxes, factory made, IP 65 sheet of size 200 x 160 x 98mm seperate detached gland plate and including MCB TPN 20 Amps and bakelite connector 4 way 20 Amp with din rail, weather vermin proof, front door opening with hinge and locking arrangement fixed to pole complete all as specified and directed. Make : Henselelectric/neptune or its equivalent in other makes.
S & F Automatic street light switch three phase max load 8-12 KW for automatic switching OFF street light at 30 Lux level and switching ON at 10 Lux of natural light the sensor alongwith suitable power contactors of rating 32 Amps per phase, MCB 40Amps TP - 01 No should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade enclosure conforming to IP 54. The contactors, MCBs and circuit wiring should be suitable enough to take load of 25KW equally distributed over three phase 415 Volts A/C complete all as specified and as directed.
Paragon Electrotechnics (BID ID -3219666)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .