Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.9 CrAccepted-AOC MADHUPUR DIGLIPUR NORTH ANDAMAN 744202 | DIGLIPUR | NORTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744202 | ₹1.9 Cr | 1 | Accepted-AOC Being Lowest Bidder |
| 2 | 2₹1.9 Cr+₹6.6 L (3.53%)Rejected-Finance MES WORKS SITE CARNICOBAR ANDAMAN NICOBAR ISLAND PIN 744301 | CARNICOBAR | NICOBAR | ANDAMAN AND NICOBAR ISLANDS | 744301 | ₹1.9 Cr+₹6.6 L (3.53%) | 2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | 3₹2.0 Cr+₹8.3 L (4.42%)Rejected-Finance | ₹2.0 Cr+₹8.3 L (4.42%) | 3 | Rejected-Finance Not Being Lowest Bidder |
| 4 | 4₹2.0 Cr+₹16.3 L (8.66%)Rejected-Finance | ₹2.0 Cr+₹16.3 L (8.66%) | 4 | Rejected-Finance Not Being Lowest Bidder |
| 5 | 5₹2.1 Cr+₹19.1 L (10.2%)Rejected-Finance | ₹2.1 Cr+₹19.1 L (10.2%) | 5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹2.1 Cr
EMD Value
₹2.9 L
Closing Date
7 Sept 2022, 6:00 pmClosed
Shri Pankaj Vyas, IDSE, Commander Works Engineer N
Commander Works Engineers No. 2, Brichgunj, Port Blair - 744 103
Provision of Perimeter Wall with Two Nos of Watch Towers, Chain Link Fencing and Associated B R and E M Works at AF Unit, Laxmipur, Diglipur
2022_MES_541273_1
80251 / E8
Open Tender
Civil Works
Lump-sum
365 days
Port Blair
Class B
Category a i
10 documents required · 10 mandatory
₹2,000
Garrison Engineer South, Diglipur
₹2.9 L
Yes
6 Oct 2022
27 Jul 2022
14 Sept 2022
27 Jul 2022
7 Sept 2022
31 Aug 2022
27 Jul 2022 - 6 Aug 2022
Amount
Schedule "A" Part – I to Schedule "A" Part – XII: [Note: Schedule "A" Part – I to Part – XI are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only]
Lumpsum price worked out by the contractor for "Buildings & Structures", as listed in Schedule "A" Part – I on Serial Page No. 33 [R].
Lumpsum price worked out by the contractor for "Site Clearance / Area Development / Earthwork Excavation", as listed in Schedule "A" Part – II on Serial Page No. 35 [R].
Lumpsum price worked out by the contractor for "POL Shed & DG Set Shed", as listed in Schedule "A" Part – III on Serial Page No. 39 [R].
Lumpsum price worked out by the contractor for "Compound Wall & Chain Link Fencing", as listed in Schedule "A" Part – IV on Serial Page No. 42 [R].
Lumpsum price worked out by the contractor for "Road / Path / Hardstanding", as listed in Schedule "A" Part – V on Serial Page No. 44 [R].
Lumpsum price worked out by the contractor for "Area Drainage", as listed in Schedule "A" Part – VI on Serial Page No. 45 [R].
Lumpsum price worked out by the contractor for "Sewage Disposal", as listed in Schedule "A" Part – VII on Serial Page No. 47 [R].
Lumpsum price worked out by the contractor for "Internal Water Supply", as listed in Schedule "A" Part – VIII on Serial Page No. 48 [R].
Lumpsum price worked out by the contractor for "Internal Electrification", as listed in Schedule "A" Part – IX on Serial Page No. 50 [R].
Lumpsum price worked out by the contractor for "External Water Supply", as listed in Schedule "A" Part – X on Serial Page No. 51 [R].
Lumpsum price worked out by the contractor for "External Electrification", as listed in Schedule "A" Part – XI on Serial Page No. 53 [R].
Schedule "A" Part – XII: [Miscellaneous Items] [Compound Wall & Chainlink Fencing, Internal Water Supply, Internal Electrification, External Water Supply & External Electrification]:
S & F Concertina Coil Fencing with Punched Tape Concertina Coil made from High Tensile Spring Steel, High Carbon Wire conforming to IS – 4454 [Part – 1], of Grade – SM duly Hot Dipped Galvanised as per IS – 4826 with 230GSM, 600mm dia, 10 Metre openable length, with Galvanised coating and Punched Tape material as per IS – 513, having 50 Nos Rounds per 6 Metre length [before stretching], having medium barbs [Barb Length 24±1mm, Barb Width 19±1mm, Pitch between Two Barbs 35±1mm], Spring Core Wire [2.6 mm thick] of high tensile strength of 165 Kg / Sq.mm with tape [0.52mm thick] and weight 43.478 Grams / Metre and fixing to “Y” or Trapezoidal shaped angle iron brackets placed at 2.00m to 3.00m apart and with 6/9 horizontal RBT [Reinforced Barbed Tape] Wire, Stud tied with GI Staples and GI Clips to retain horizontal, including necessary bolts and coating with Px Compound [Anti Rust] complete all as specified and as directed. Note: Horizontal barbed wire & angle iron supports shall be measured and paid separately under relevant items of Schedule "A". Measurement shall be made for stretched length.
S & F PVC Coated Chain Link MS Galvanised Fencing Mesh of size 75 mm X 75mm, 4mm dia wire with minimum 1 mm thick PVC Coating and of weight not less than 4.0 KG / Sq.m including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified and as directed.
All as per Serial Item No. 14 above but for One Light Point controlled by Two Nos. of, Two way Switches complete all as specified and as directed.
All as per Serial Item No. 14 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 14 above but One 3 Pin Switch Socket Outlet 5 Amps on Same Board complete all as specified.
All as per Serial Item No. 14 above but one 3 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 2000 Lumens output, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 1000 Lumens output, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
M & L for Construction of Valve Chamber of size 600 X 600 X 600 mm internal size suitable for Sluice Valve, with PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified and shown on drawing.
Crusher Dust / Stone Dust / M-Sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.
S & F Energy efficient LED Flood Light fitting, of not less than 12000 Lumens output, 6500 K, with Pressure Die Cast Aluminium Housing, IP66 Protection and Surge Protection device of 10 KV, Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Energy efficient & Long life Street Light Luminaire, of not less than 3500 Lumens output, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
Supply Install Test and commissioning of Silent Diesel Engine driven Generating Set of Capacity 50 KVA / 40 KW, 415 Volts, Three Phase, 4 Wire, Engine as per IS – 10001 / 10002 and Alternator as per IS – 13364 complete with relay panel for automatic starting on main failure, control panel having meters, sound proof canopy as per relevant IS and foundation etc. including following: [Make: Kirloskar Green / Cummins / Ashok Leyland / Greaves Cotton] A. ENGINE: Direct Injection, Water / Air Cooled Engine, 2 Cylinder, in-line, 4 Stroke, rated at 1500 RPM, conforming to BS – 5514 and having following specifications: [i] In- line fuel pump with Electronic Governor for 50 KVA. [ii] Turbocharger [iii] Stainless Steel Exhaust Flexible Coupling and Exhaust Pipe duly insulated with Glass Fire Wool and Plain GI Sheet Cladding & extended outside the building. [iv] Silencer [v] Radiator [vi] Coolant Inhibitor [vii] Plate type Lub Oil Cooler [viii] Spin-On-Filters-Coolant, Fuel, Fuel & Lub Oil [ix] Dry type, Heavy Duty, Replaceable Paper Element Air Cleaner with Restriction Indicator [x] Flywheel Housing and Flywheel to suit Single Bearing Alternator [xi] Electrical Starter Motor [xii] Battery Charging Alternator [xiii] 1x12 Volts Batteries, 88 AH Capacity with multistranded copper cable for connecting leads and terminals [xiv] First fill of Lub Oil.
B. ALTERNATOR: [i] Self Excited & Self Regulated [ii] Voltage Regulation ± 1 % [iii] Class H Insulation [iv] Salient Pole Revolving Field [v] Digital Automatic Voltage Regulator [Part of PCC 1301] [vi] Standard Enclosure IP-23 [vii] Telephone Interference Factor: 50 [viii] Total Harmonic Factor: Better than 2% [ix] Supplying power to variable electrical load for unlimited hours. Prime power [PRP] is in accordance with ISO 8528. 10% over load capacity for one hour every 12 Hours of operation and will be suitable for tropical condition.
D. FUEL TANK: [i] Fuel Tank of suitable capacity for minimum 12 Hours run with provision for Supply and Return Lines, Level Indicator, Drain Valve, Cleaning Cover Vent Pipe & Locking Device. [ii] MS Fuel Pipeline from Fuel Tank to FIP of suitable size. [iii] Fuel Tank shall be mounted / located outside the cubicle with suitable mounting with angle iron supports. E. ACOUSTIC ENCLOSURE: [i] Designed to meet stringent MOEF / CPCB norms 75 dBA @ 1 m at 75% load under free field conditions. [ii] Air Inlet Louvers shall be designed to operate at rated load even at 50°C Air Inlet Temperature. [iii] Cubicle shall be powder coated for long lasting service life and super finish with UV Resistant Powder Coating and shall withstand extreme environment. Stainless Steel hardware shall be used. [iv] Insulation Material shall meet / conform to IS – 8183 Specifications for better sound attenuation [v] Provision of Genset Controller for Engine & Alternator.
F. ACCESSORIES: [i] Periodical Maintenance Tools as per Manufacture [ii] Operational, Spare Parts, & Installation Guidelines and Catalogue. NOTE: Rate quoted is also deemed to be including the following: [i] Testing of DG Set shall be carried out by the IEM in presence of the OEM Representative. [ii] Artificial load i.e. strip heaters of suitable capacity and Diesel required for testing shall be made available during test by the contractor. [iii] Extended terminals with tinned copper has to be provided for terminating the incoming & out going cable with suitable lugs for ACB’s / MCCB's if required. [iv] U/G cable shall be laid / connected to DG Set Cubicle Panel to AMF Control Panel [Changeover Panel] all as specified and as directed [v] Provision of cable gland & Aluminium lugs of suitable size for terminating the cable at both ends.
ASHOK BISWAS
M/S VISHAL CONSTRUCTION
M/s V M K Construction
CITY CONSTRUCTION COMPANYU
Prasur Electricals & Engineering Co.
Kakolil Trade Agencies
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .