Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹83,745Qualified 21 KHUDDA KHURD AMBALA CANTT VIKASPURI AMBALA HARYANA 133001 | AMBALA | HARYANA | 133001 | L1 | Qualified MSE, MII, Category: General | |
| 2 | L2₹1.6 L+₹75,465 (90.1%)Qualified 5301 BHERPINDER PAL GARG ANAJ MANDI PUNJABI MOHALLA AMBALA HARYANA 133001 | AMBALA | HARYANA | 133001 | L2 | Qualified MSE, MII, Category: General | |
| 3 | L3₹2.0 L+₹1.1 L (133.6%) 11 29 11 29 CIVIL LINES ROAD SOUTER GANJ CIVIL LINES ROAD SOUTER GANJ KANPUR CITY UTTAR PRADESH 208001 | KANPUR NAGAR | UTTAR PRADESH | 208001 | L3 | - | |
| 4 | L4₹2.1 L+₹1.2 L (147.8%)Qualified UNIT 304 SECOND FLOOR AMAR PROPERTIES HASANPUR VILLAGE I P EXTENSION PATPARGANJ DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | L4 | Qualified MSE, MII, Category: General | |
| 5 | L5₹2.2 L+₹1.4 L (165.1%)Qualified 109 1 BHRAMA NAGAR NEAR MAIN ROAD NEHRU NAGAR KANPUR UTTAR PRADESH 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | L5 | Qualified MII |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
11 Jun 2025, 5:00 pmClosed
Bunsen Burner
Heating Mantle
Heating Mantle for 6 sets of Soxhlet apparatus
Hot Air Oven-Digital
Microscope
Moisture Dish-Aluminum
Silica Crucible Cap 25 ml and 50 ml
Top Loading Monopan Balance Digital
Water bath
Weight Box
Thermocouple sensor
Vortex Machine
Digital Hygrometer Bid Number ( ) : GEM/2025/B/6258889 Dated : 21-05-2025 Bid Document 1/17
7871186
GEM/2025/B/6258889
Two Packet Bid
Top Loading Monopan Balance Digital
15 days
208017, Regional Agmark Laboratory, NSI Campus, Kalyanpur, Kanpur-
Total value wise evaluation
BOQ
9 documents required · 9 mandatory
3 yrs
₹3
20%
Exempted
21 May 2025
21 May 2025
11 Jun 2025
LABORATORY INSTRUMENT
Heating Mantle for 6 sets of Soxhlet apparatus
Hot Air Oven-Digital
Moisture Dish-Aluminum
Silica Crucible Cap 25 ml and 50 ml
Top Loading Monopan Balance Digital
Thermocouple sensor
Digital Hygrometer Bid Number ( ) : GEM/2025/B/6258889 Dated : 21-05-2025 Bid Document 1/17
Bunsen Burner Specifications: - Base Diameter- 3.25 in.
Burner Place Diameter- 1 in.
Height- 5.7 in.
Height with base- 7.25 in.
material- Nickel with flame stabilizer to control flame temperature and length (three spoke bases) for LPG gas. It should give non luminous flame while in use.
Heating Mantle "Size- 1 litre
Thermostatically controlled with indicator "
Heating Mantle for 6 sets of Soxhlet apparatus 1. Individual built-in solid state electronic thermostatically controls enable easy regulation of heater. 2. Three 12.7mm diameter support rods are included. 3. Round bottom flask capacity from 100ml to 500ml at all 6 positions. 4. Top cover is polypropylene and external surfaces are powder coated giving good general chemical resistance. 5. Coiled heating element is suspended within a thermal insulating cartridge to provide maximum heat transfer and support. 6. Earth (ground) screen encloses the heater for added safety. 7. Individual heater cartridges are replaceable. 8. Neon lights indicate when power is on and supplied to heaters and
supplied to stirrers.
Hot Air Oven-Digital Size- 24"x24"x36" or more inner chamber
Temperature range 500C to 3000C or better with accuracy of ±20C. Digital display of temperature. & controller. Suitable for 220 to 240 volt.
Microscope "Compound microscope should have:- 1. Eye piece lens 5X
10X power. 2. Condense lens can be moved up & down. 3. Diaphragm on iris has a rotating disc. 4. Object lens 10x
40X & 100X power. 5. Illuminator- steady source of light in place of mirror/reflector. 6.Mechanical stage should be able to move slide around by turning knobs
one move in left and right and other move it up & down "
Moisture Dish-Aluminum Dia. 7- 8 cm.
depth- 1.5 to 2.0 cm.
Thickness- 0.2 to 0.4 mm.
Silica Crucible Cap- 25 ml & 50 ml. "1. As per BIS specification Type 2 — Medium form
based on a height diameter ratio of 0.8 [see Fig. 1 (b)]. 2. Nominal capacity = approximately 75 percent of overflow capacity. Lids- Type D — A lid of slightly domed shape. 3. Material- Silica crucibles and lid shall be made from vitreous silica
either translucent or transparent. "
Top Loading Monopan Balance - Digital "Minimum weight 0.1 mg. Weight capacity- 200 gm. Calibration in-built. Digital display. Sensitivity ± 0.0001( four decimal place) Minimum weight 0.1 mg. Weight capacity- 200 gm. Calibration in-built. Digital display. Sensitivity ± 0.0001( four decimal place) "
Water bath SS Double layer
12 holes and standard quality with thermal regulator controller.
Weight Box "F1 Grade for calibration of balance "
Thermocouple sensor "Temperature range-0 to 1800 degree celcius. Input sensor-RID
K type Thermocouple LED Display
Power suplly-230volt No of set point-two(configurable for high & low) Resolution-1 degree Celsius "
Vortex Machine Power-32 watt
Shaking movement-orbital
orbital diameter-4 mm
motor type- shaded pole motor
Speed range-0 to 2500 rpm
Dimension(mm)-185×150×165
power supply-220-240volt
Digital Hygrometer "Temperature 20⁰C to 60⁰C Readability 0.1⁰C Temperature Accuracy ±0.5⁰C to ±1.0⁰C Resolution 0.1⁰C Temperature Update Rate 500ms Data Storage Capacity 99points RH-Range 5% to 95% (RH ± 2.5%) Display-Backlit dual display of humidity and temperature Calibration- Certificate Calibration Certificate from ISO17025 for Temperature and Relative Humidity Warranty- 2 years " Bid Details 2/17
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_7871186.pdf
GEM_BID
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
dec_spec_2025-05-21-16-11-14_126a9511091254b1ef53863403c5e1ef.pdf
BOQ
boq_item_sample_file_-3_2025-05-21-16-11-14_32f8f068769c112225b652ee3fcf3a76.csv.pdf
BOQ
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .