| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹26.2 L+₹1.3 L (5.05%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹27.7 L+₹2.8 L (11.2%)Rejected-Finance | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹29.9 L+₹5.0 L (19.9%)Rejected-Finance | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹31.1 L+₹6.2 L (24.7%)Rejected-Finance | L5 | Rejected-Finance Being not lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
15 Jan 2024, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER JORHAT, MES, JORHAT-785005
COMPREHENSIVE MAINTENANCE OF BUILDING SERVICES AND ELECTRIC SERVICES AT CERTAIN FAFA MD ACCNS AT LICHUBARI UNDER GE JORHAT
2024_MES_635799_1
8148/2/E8
Open Tender
Civil Works
Item Rate
334 days
Jor-05
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER Jorhat
₹50,000
Yes
9 Feb 2024
4 Jan 2024
16 Jan 2024
4 Jan 2024
15 Jan 2024
10 Jan 2024
4 Jan 2024 - 9 Jan 2024
Amount
NOTES :The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Dismantling AC roof corrugated sheet, thickness including eves gutter / rain water pipe complete & removal all as specified
Material, labour and fixed Rolled mild hollow steel sections steel of grade YSt 310 conform to IS 4923 in roof trusses (framed), trussed, purlins, bracing and fastenings including distance pieces, cleats etc.complete all as specified and as directed.
Material, labour and fixed of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Material, labour and fixed of pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridges, tips, valley, gutters, length & girth as fixed with nail or screws complete all as specified and as directed.
Material, labour and fixed of power coated GI exposed snap grid frame work for false ceiling, size of grid 605 x 605 mm, including GI main tee of size 25mm x 35mmx0.7 mm ( minimum), GI cross tree of size 25mmx 35mmx 0.70mm and GI wall angle of size 25mmx25mmx0.7mm(minimum) suspended form soffit at approx 900mm centre to entre with GI cleat and steel expansion fasteners with and including level clip and 6mm dia GI wire hanging arrangement with adjuster all as specified in drawing in section -8 of SSR part-II and including 6 mm thick high pressure steam cured non asbestos fibre cement designer board as per IS 14862 with applying of two coats of acrylic distemper over a coat of primer including takingdwon old one complete all as specified and directed.
Stripping out tarfelt from old roof surfaces and removing unserviceable materials from site of work in low laying in outside MOD area and brushing and applied neat cement slurry with 3.0 Kg of cement per Square Metre existing surface complete all as specified and as directed.
Supplying and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 3.6 kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt laying over a coat of bituminous primer @ 0.40 Ltr / Sqm and two coats of Bitumen based UV reflective paint with aluminium finish over APP membrane. The membrane shall be laid using butane torch and sealing all joints etc all as specified in Para 11.44.5 of SSR Part I complete all as specified and as directed.
Demolition of Reinforced cement concrete (reinforcement cut as required to facilitate demolition) in any position and removing debris to a distance n.exc. 50 m etc complete all as specified and as directed.
Material and labour for TMT Bars Fe 500D 6mm dia & 8 mm dia cut to length bent to shape required inculding cranking bending spirally hooping for columns etc and binding with MS wire ennealed less than 0.9mm dia or securing with clip complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors, sunken floor and paving complete all as specified
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to stores and rubbish off the MOD premises complete all as specified and as directed.
Material and labour for 75 mm thick plain cement concrete M-10(Nominal Mix) using 20 mm graded stone aggregate as in plinth protection, finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 40 mm thick plain cement concrete 15 (Nominal Mix) using 20 mm graded stone aggregate aggregate as in base floor finishing cement concrete surfaces rough etc complete all as specified and directed
Material & Labour Non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular area of each tile exceeding 0.06 Sqm and not exceeding 0.11 Sqm , in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed layer in CM (1:4) including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushign neat cement slurry with 3.0 kg of cement per Sqm complete all as specified and as directed.
All as per item no but as in skirting/dado but over 10 mm thick rendering over CM 1:4
Material & Labour Glazed ceramic tiles 450x300/ 300x200 x7 mm(Coloured) on vertical surfaces such as skirting, dados and riser to steps etc. set and jointed in neat cement slurry and pointed in coloured cement to match complete over 10mm thick screed bed vertical layer in CM (1:4)all as specified and as directed.
Material and labour for pre-polished chequered Cement Concrete tiles of 25 mm minimum thick, size of (square/ rectangular) area of each tile exceeding 0.09 Sqm but not exceeding 0.16 Sqm double layer machine pressed set ( as per IS 1237-2012), jointed and pointed in neat cement slurry in floors and cut & polished in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Cutting holes in brick walls exceeding half brick but not exceeding one brick built in cement mortar for inserting hold fasts of GI pipe and making good dismantled portion in cement concrete 1:2:4 type B1 exceeding one brick.
Material and labour for Brick work with bricks class designation 75, old size, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
Material and labour for brick work with bricks class designation 75, size as per old size brick, straight or curved on plan exceeding 6 m mean radius half brick thick walls built in Cement Mortar 1:4 complete all as specified and as directed.
Taking down cement plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. and removal outside of MOD land complete all as specified and as directed.
Rendering 15 mm in Cement Mortar 1:6 on fair faces of brick work or concrete surfaces finished even smooth without using extra cement to the plastered surface complete all as specified and as directed.
Material and labour for Rendering 15mm thick plaster in Cement Mortar (1:4) on fair faces of brick or concrete surface of wall and finished even and smooth without using extra cement, with water proofing treatment. Note:- Water proofing compound shall be measure and paid separately
Material and labour for Rendering 5mm thick plaster in Cement Mortar (1:3) on fair faces of concrete surface on ceiling and finished even and smooth with using extra cement, with water proofing treatment.
Supply only integral liquid water proofing compound
Material and labour for Preparation of new plaster wall surface and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litre of required colour shade and as per manufacturer’s specification over a coat of primer over a coat of 1.0 mm thick cement base wall putty complete all as specified and directed.
Material and labour for Preparation of new plaster ceiling surface and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litre of required colour shade and as per manufacturer’s specification over a coat of primer over a coat of 1.0 mm thick cement base wall putty complete all as specified and directed.
Material and labour for complete removal of existing finishing of internal wall surface of building/structure by mechanical appliance and preparation of old surfaces and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litre of required colour shade and as per manufacturer’s specification over a coat of primer over a coat of primer over a coat of 1.0 mm thick cement base wall putty complete all as specified and directed.
Material and labour for preparation of old internal wall surface of building/structure and preparation of old surfaces and applying one coats of acrylic washable distemper complete all as specified and directed.
Material and labour for preparation of new surfaces and and applying 2 coats of cement based paint over a coat of alkali based primer complete all as specified and directed.
Material and labour for Preparation of old external wall surface and applying one coat of cement based paint of any description over 10 cm girth or width complete all as specified and directed.
Taking down chowkats/frames with shutters (without taking off shutters from the frame) etc. exceeding 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified and as directed.
Taking down chowkats/frames with shutters (without taking off shutters from the frame) etc.exceeding 1.0 Sqm but not exceeding 1.50 Sqm each complete all as specified and as directed.
Taking down shutters of any description n exc 1 sq. m each complete all as specified and directed.
Mild steel work as in bands, straps, supports or stays for RWP, ventilating pipes, clamps, hold fasts, wall ties conforming to Fe-290 Gde E-165
Supply and fixing of 2nd class HW Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-1 using 20mm graded crushed aggregate as in filling in holdfast/ filling in pressed steel frame etc including necessary form work complete all as specified and directed.
Material and labour for 30 mm thick, second class hard wood, factory made glazed and skeleton shutters, open rebated and prepared to receive gauze, etc. with plain chamfered or rounded, mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed.
Supply and fixing of 30 mm thick flush shutters, solid core construction, with block board core and comercial plywood face panels with one face is covered with decorative face veneer with lipping/frame to match all complete all as specified and as directed.
Material and labour for Solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with Mild Steel square tube, suppling & fixing in opening as per drawing complete all as specified and directed.
Material and labour for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawingcomplete all as specified and directed.
Supply and fixing of steel ventilator with top hung shutters including hinges with steel handle and steel peg stay complete without gauged bars, dovetailed or welded complete all as specified and as directed
Supply and fixing of steel windows with side hung shutters including hinges projecting type with steel handle and steel peg stay complete with gauged bars, dovetailed or welded complete all as specified and as directed
Supply and fixing of steel windows with side hung shutters including hinges box type with steel handle and steel peg stay complete without gauged bars, dovetailed or welded complete all as specified and as directed
Material and labour for Mild Steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290(Gde E-165) complete all as specified and directed.
Supply and fixing of sheet glass 4 mm thick ordinary quality fixed to aluminum door & window in squares in each pane of required size complete all as specified and as directed.
Supply and fixing of Butt hinges Stainless steel 100 mm size complete all as specified and directed.
Supply and fixing of Aluminium anodised barrel tower bolts of extruded section size 150 mm complete all as specified and directed.
Supply and fixing of Aluminium anodised barrel tower bolts of extruded section size 200 mm complete all as specified and directed.
Supply and fixing of Aluminium handles cast type anodised 150 mm size complete all as specified and directed.
Supply and fixing of Aluminium handles cast type anodised 125 mm size complete all as specified and directed.
Supply and fixing in repairs Stainless Steel drapery road (1 mm thick stainless) steel section outer dia 25 mm with bracket, ring & fancy side holders complete all as directed by Engr-in-Charge
Supply and fixing in repairs of Hasp and staple, safety type, Stainless Steel with Stainless Steel hinge pin including bolt to hinge plate and fixed with screws of size 100 mm.
Supply and fixing of 300mm ordinary rat tail rod pattern springs including roller and roller plate complete made out of brass complete all as specified and as directed
Supply and fixing in repairs of small fitting of second class HW such as brackets of any type latch and hinge block, shaped door and window stops and the like incl all necessary labour articles not exceeding 200 Cu cm each. complete all as specified and directed.
Supply and fixing of Stainless steel wire cloth, 0.36mm nominal dia of wire and avergae width of aperture 1.00 mm and fixed with stainless steel wire staples complete all as specified and directed.
Supply and fixing in repairs Stainless steel wire cloth, 0.36 mm nominal dia of wire and avergae width of aperture 1.00 mm and fixed with stainless steel wire staples complete all as specified and directed.
Material and labour for 18/19 mm thick prelaminated particle board exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work including taking dwon old one complete all as specified and directed.
Material and labour for preparation of new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel and iron surfaces of any description over exceeding 10 cm in width or girth complete all as specified and as directed..
Material and labour for Painting 2 coats of synthetic enamel paint on wooden surfaces of any description over 10 cm in width or girth including preparation new surface and one coat of pink primer complete all as specified and as directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
Supply and fixing of 15mm bore galvanised steel tubes, medium grade with all fitting and fixed to walls, ceiling, floors and including taking up old GI pipe complete all as specified and as directed.
Supply and fixing of 20mm bore galvanised steel tubes, medium grade with all fitting and fixed to walls, ceiling, floors and including taking up old GI pipe complete all as specified and as directed.
Supply and fixing in repair of bib cock cast copper alloy screwed down with long body with wall flange, and fixed for 15 mm bore GI tube pipe and all accessories complete all as specified and as directed. complete all as specified. Make :- Cat no 272210120031(DHAARA) of Somany or equivalent model of make list as given in PS as approved by GE.
Supply and fixing in repair of chromium plated pillar cock cast copper alloy screwed down with long body with wall flange, and fixed for 15 mm bore GI tube pipe and all accessories complete all as specified and as directed. complete all as specified. Make :- Cat no 272210120011(DHAARA) of Somany or equivalent model of make list as given in PS as approved by GE.
Supply and fixin of in repair 15 mm bore chromium plated stop valve with crutch handle ,fancy type , screwed both ends for iron pipes etc complete all as specified and directed. Make :- Cat no 272210120071(DHAARA) of Somany or equivalent model of make list as given in PS as approved by GE.
Supply and fixing of 15mm bore angle valve type cast copper alloy chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe for union 15mm complete all as specified and directed.
Supply and fixing in repair of Bib tap standard of PTMT any colour high pressure screwed for 15 mm bore dia iron pipe and fixed .(Minimum weight 15mm-90gms) complete all as specified.
Supply and fixing in repair of pillar traps standard of PTMT any colour high pressure screwed for 15 mm bore dia iron pipe and fixed .(Minimum weight 15mm-90gms) complete all as specified.
Supply and fixing in repair of stop angle valve standard of PTMT any colour high pressure screwed for 15 mm bore dia iron pipe and fixed .(Minimum weight 15mm-90gms) complete all as specified.
Supply and fixing of vitreous china wash basin white flat back, size 550 x 400 mm including CP waste coupling,with GI pipe brackets & , rag bolt in cement concrete/brick wall and including taking down existing HWB and making good wall surface complete all as specified and as directed.
Supply and fixing of Vitreous china squatting pan, 'Orissa' pattern, size 580x440 mm white with including CI ‘P’ or ‘S’ trap & integral foot rests fixed in cement concrete and including taking down existing one complete all as specified and as directed
Supply and fixing of Vitreous china wash down water closet (pedestal pattern) with concealed S-trap or P-Trap, white, 390 mm high, seat cover including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc and including taking down existing one complete all as specified and as directed
Supply and fixing as in repair of PVC low level flusing cistern 10 litres capacity white with ball valve & brackets with flush pipe complete all as specified and as directed.
Supply and fixing as in repair of PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and as directed.
Supply and fixing in repair of 125 mm dia of shower rose with 225 mm long arms, cast copper alloy chromium plated , swivel joints and fixed for 15 mm bore GI tube pipe and all accessories complete all as specified and as directed. complete all as specified.
Supplying, hoisted and fixed in position of rotational moulded polyethylene water storage tanks in double layers and cylindrical vertical type with manhole lids(closed top) of 500 litres capacity with ISI marked and all as specified in IS 12701 and including taking down existing water tank complete all as specified and directed .
Supply and fixing of PVC ball valve for 20 mm dia GI pipe all complete complete all as specified and directed.
Supply and fixing of uPVC of type-B for use in soil and waste discharge systems, single socket, 110 mm bore in any length including rubber ring joints and fixed to walls with clips and other standard material and including taking dwon old rain water pipe & removal from site all as specified in IS 13592 complete all as specified and directed.
Supply and fixing of uPVC of type-B for use in soil and waste discharge systems, single socket, 75 mm bore in any length including rubber ring joints and fixed to walls with clips and other standard material and including taking dwon old rain water pipe & removal from site all as specified in IS 13592 complete all as specified and directed.
Supply and fixing of Unplasticized (uPVC )bend for 110 mm bore uPVC pipe complete all as specified and directed.
Supply and fixing of Unplasticized (uPVC )bend for 75 mm bore uPVC pipe complete all as specified and directed.
Supply and fixing of Unplasticized (uPVC )juction equal or unequal for 110 mm bore uPVC pipe complete all as specified and directed.
Material and labour for PVC(SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directe
Material and labour for PVC(SWR) nahani trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directe
Supply and fixing of in repair uPVC (SWR) muti trap 75 mm, plain with CP grating including joining and solvent cement complete all as specified and directed.
Supply and fixing of in repair uPVC (SWR) floor trap 75 mm, plain with CP grating including joining and solvent cement complete all as specified and directed.
Supply and fixin of in repair 32 mm dia waste coupling suitable for kitchen sink waste pipe etc complete all as specified and as directed by Engineer-in-Charge .
Supply and fixing as in repair of health faucet of ABS body with wall hook and including one metre long stainless steel braided rubber hose pipe fixed on 15 nn dia angle cock all complete complete all as specified and directed Make:- Cat No. BEA-41 Prayag equivalent model of make list as given in Approved Make list .
Plain Cement Concrete M-10(Nominal Mix) using 12.5 mm graded stone aggregate as in making good window opening, lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, coping, kneelers, apex stones, bed plates, kerbs, water trough and the like including weathering slightly rounded or chamfered angles and throating complete all as specified and directed.
Material and labour for Plain Cement Concrete M-15(Nominal Mix) using 20 mm gaded stone aggregate as in Surface channel and drain
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.
Cutting into existing manhole for connecting new drain, making good to pipe & rendering, cutting out existing benching for and forming branch channel (half round or 3/4 section) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate for 100 mm bore pipe complete all as specified and directed.
Cutting into existing manhole for connecting new drain, making good to pipe & rendering, cutting out existing benching for and forming branch channel (half round or 3/4 section) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate for 150 mm bore pipe complete all as specified and directed.
Supply, laying and testing of PVC(SWR) pipe of 100 mm dia with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS-16098-2013 part-2 complete all as specified and as directed. .
Material & Labourfor for cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes 100 mm bore, including packing under and hunching against the sides of pipes after they are laid and tested complete all as specified and as directed. Note:- Thickness of PCC bed 10 cm and width of PCC bed shall be outer dia of pipe plus 30 cm.
Removing all deposited material i.e. mud, solids, brick bats, polythene silt etc from surface drain of any girth and cleaning of surface area of drain by wire brush completes as and specified and directed.
Material, T&P and labour for Cleaning of sewage line of any dia/bore including manhole using the cleaning devices and removing blockage if any and removing the waste outside MD land etc complete all as specified and as directed.
Material, T&P and labour for Cleaning of blockage of wash basin, floor trap, nahani trap, gully trap (GT), kitchen, bath etc. (carrying sludge) in any length upto the first manhole by any means (using chemical or any mechanical device) & flushing with water complete all as specified and as directed.
Material, T&P and labour for Cleaning of blockage of WC/Urinal (carrying soil waste) in any length upto the first manhole using the cleaning devices and removing blockage if any complete all as specified and as directed.
Material and labour for cleaning of PVC tank of capacity exceeding 750 ltr and not exceeding 1000 ltr with fibre brush to remove all dirts and removing sediments and through cleaning of rotational moulded polythene water storage tank and then with dilute bleaching powder solution(not less than 1.2 Kg per tank) and and finally cleaning with fresh water complete all as directed.
Material and labour for cleaning of PVC tank of capacity exceeding 250 ltr and not exceeding 500 ltr with fibre brush to remove all dirts and removing sediments and through cleaning of rotational moulded polythene water storage tank and then with dilute bleaching powder solution(not less than 0.75Kg per tank) and and finally cleaning with fresh water complete all as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out as in soft/loose soil.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level n. exc. 1.50 m above the starting point.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil.
Material and labour for Plain Cement Concrete M-7.5(Nominal Mix) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Supply and fixing in repair of stainless steeel of 304 grade of kitchen sink with drain board of overall size 915mmx460mm and bowl size 410mm x330mmx160mm depth or equivalent made of 1mm thick stainless steel sheet with 32mm bore CP waste coupling including ball and chain 300mm long with bass cap rubber plug, 32mm bore PVC waste pipe (heavy duty) 90cm long, and bedded in cement mortar and fixed in CP cantilever brackets. Make: Cat No. 1239D of PRAYAG or equivalent make as per PS
Material and labour for Plain Cement Concrete M-15(Nominal Mix) using 20 mm graded stone aggregate in roof kerbs or mud stops, benching,rounded or chamfered on edges including necessary formwork. complete all as specified and as directed.
Material and labour for Precast Reinforced Cement Concete cover slab type M-20 (Nominal mix) using 20 mm graded stone aggregate, set in Cement Mortar (1:4) complete all as specified and directed.
Material and labour for cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes 150 mm bore, including packing under and hunching against the sides of pipes after they are laid and tested complete all as specified and as directed. Note:- Thickness of PCC bed 10 cm and width of PCC bed shall be outer dia of pipe plus 30 cm.
Up rooting of tree from walls/ roof surface of bldgs up to extranded root and spraying of Muratic Acid required quantity complete from any location of bldg and making good disturbed surface with cement mortar(1:4) or cement concrete type C1 (1:3:6) using 20mm graded aggregate complete all as specified and directed.
Subtotal of Sch A part-I
SCHEDULE 'A' PART - II FOR E/M PORTION (Sl No __ to ____)
Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and switch boxes etc complete and making good the disturbed surfaces complete all as specified and as directed.
Material and labour for point wiring with PVC insulated unsheated stranded copper conductor cable of size 1.5 sq mm in and including PVC cassing caping of required width with all necessary fittings with sunk cast iron /pressed steel terminal box of1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan/bell controlled by one switch complete all as specified and directed .
Material and labour for point wiring with PVC insulated unsheated stranded copper conductor cable of size 1.5 sq mm in and including PVC cassing caping of required width with all necessary fittings with sunk cast iron /pressed steel terminal box of1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly one 3 pin socket outlet 5 amps on the same board with other switchescomplete all as specified and directed .
Material and labour for point wiring with PVC insulated unsheated stranded copper conductor cable of size 1.5 sq mm in and including PVC cassing caping of required width with all necessary fittings with sunk cast iron /pressed steel terminal box of1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one 5 amp socket independent complete all as specified and directed .
Material and labour for point wiring with PVC insulated unsheated stranded copper conductor cable of size 4.0 sq mm in and including PVC cassing caping of required width with all necessary fittings with sunk cast iron /pressed steel terminal box of1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 4.0 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one 5 amp socket independent complete all as specified and directed .
Supply and fixing of switch piano flush single pole one way 5 amps complete all as specified and as directed.
Supply and fixing of switch socket outlet 3 pin 6 Amps 230 volts Universal type complete all as specified and as directed.
Supply and fixing of switch piano flush single pole one way 15 amps complete all as specified and as directed.
Supply and fixing of socket outlet 3 pin 6/15 Amps 230 volts Universal type complete all as specified and as directed.
Material and labour for Electronic type fan regulator step type 120 watt, 230 volt complete all as specified and as directed. Make : Code no 14502 of Anchor or equivalent model of make list as given in PS as approved by GE.
Supply and fixing ceiling rose surface bakelite 65x50mm three terminals complete all as specified and as directed.
Supply and fixing in repair of LED surface/ceiling mounting(suspended from ceiling) box type light fitting 20Watt with LED Lamp , drive and made of epoxy powder coated extruded aluminium channel housing with high quality polycarbonate opal diffuser cover & high power LED’s as light source with 120 Lumen per watt (Minimum) and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up three core1.00sq. mm copper conductor flexible wire/cable complete all as specified. Make : Model No CCS-100-20-65-HL2-DP-NWH of Crompton/ BCLAB 20W WH LED P of Bajaj or equivalent model of make list as given in PS as approved by GE.
Supply and fixing of sheet metal enclosure for MCBs to be used singal pole & nutral double door 8 Way 200 Amps rated busbar and including fixed with 25mm x 6 mm mild steel clamp of suitable length complete all as specified and as directed.
Supply and fixing of MCB SP of rating 6 to 32 Amps 240 V complete all as specified and as directed.
Supply and fixing MCB DP 40 to 63 amps 415 volts 10KA breaking capacity complete all as specified and as directed.
Supply and fixing of sub main wiring with two single core 4.0sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC double lock casing caping and accessories accessories including one single core 4.0 sqmm copper conductor cable FRLSH as earth wire and including taking out old sub-main wiring complete all as specified and as directed. NOTE:- (a) All runs of copper conductor and one run of conduit shall be measured as one run length.
Taking down ceiling fans of 1200 mm sweep and any size including cable connections and disconnecting of fan blades and removing the fan with blades to store yard and hanging ceiling fan in its original position or any other position including as per direction of Engineer-in-Charge including fitting and fixtures after carrying out the repairs i.e cleaning, greasing and filling, painting of fan with one coat of synthetic enamel paint by spraying machine after preparation of surface by cleaning all dust and filling cavity with filler, reassembling the fan etc including testing complete all as specified and directed by Engr-in-charge.
Taking down of 225 mm Sweep exhaust fan and any size including cable connections and disconnecting of fan blades and removing the fan with blades to store yard and hanging ceiling fan in its original position or any other position including as per direction of Engineer-in-Charge including fitting and fixtures after carrying out the repairs i.e cleaning, greasing and filling, painting of fan with one coat of synthetic enamel paint by spraying machine after preparation of surface by cleaning all dust and filling cavity with filler, reassembling the fan etc including testing complete all as specified and directed by Engr-in-charge. Note for item no 133 to 134 :- Contractor's quoted rates shall including the following (i) Taking down fan and refixing in the same position and or any other position complete with its all fittings and fixtures to make it complete functional and testing complete. (ii) All spare part (except spare part mentioned in here-in-below) repairs including greasing, oiling, prepartion of surface including filling to receiving a coat of paint (iii) Painting of MES number (only) with black paint
Material and labour for rewinding of burnt fan motor with super enameled copper wire suitable for ceiling fan of sweep up to 1200 mm complete all as specified and as directed by Engr-in-Charge.
All as per item No-58 above but for 225 mm Sweep exhaust fan complete all as specified and as directed.
Supply only fan capacitor 2.5 MFD after complete all as specified and directed. MAKE : Bajaj / Universal / Usha.
Supply only fan capacitor 3.15 MFD after complete all as specified and directed. MAKE : Bajaj / Universal / Usha.
Material and labour for comprehensive repair/ maintenance of storage type electric water heater (geyser) vertical or horizontal type of capacity 25/50 ltrs comprising of the following :- (a) Inspection, taking down, opening or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank upto the satisfaction of the Engr-in-Charge. (b) Checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc in situ to ensure free movement of the parts including supply and replacing then washers/ gasket nut etc. (c) Checking and rectifying earth continuity of the electrical circuits of the geyser and power point. (d) Checking and refixing thermostat and re-adjust (e) De-scaling the immersion type heating element and siphon assembly with diluted hydro chloric acid or clear pedette solution. (f) Checking of indicator lamp for its serviceability (g) Re-assembling the Geyser, re-install and testing complete. Note :- Contractor's quoted rates shall including the following (i) Taking down fan and refixing in the same position and or any other position complete with its all fittings and fixtures to make it complete functional and testing complete. (ii) Parts/ components of geysers found unserviceable shall be replaced by the contractor with new parts/ components and same shall be measured and paid separately (except spare part mentioned in here-in-below) and other minors parts shall be deem to be quoted rate.
Supply only Heating element 2000 Watt complete all as specified and directed.
Supply only Heating element 1500 Watt complete all as specified and directed.
Supply only Thermostat for geyser suitable to work up to 80' C complete all as specified and directed.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron using GI 4 mm dia wire as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer complete all as specified and directed .
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ₹ ___________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
A M CHOUDHURY AND CO
M/S M R CONSTRUCTION & CO
SUBHAS CONSTRUCTIONS
M/S AJOY DUTTA CHOWDHURY & CO
NIHAR ENTERPRISE
M/S RAJIB GOSWAMI ENTERPRISE
Chief Builders &Consultants
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .