| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.3 LAccepted-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹47.5 L+₹3.7 L (8.54%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹47.5 L+₹3.8 L (8.64%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹47.5 L+₹3.8 L (8.71%)Rejected-Finance MOHALLA KAMA KHAN WARD NO 07 HOUSE NO 88 DISTT POONCH J K | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/S RAHUL GUPTA L3 | JAMWAL CONSTRUCTION CO L4 | NATIONAL TRADING COMPANY L1 | VIKAS ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | B/R PORTION:
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. | 12.7 | Cum | 100 ₹1,270 | 10 ₹127 Lowest | 200 ₹2,540 | 100 ₹1,270 |
| 2.00 | Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. | 138.3 | Sqm | 10 ₹1,383 Lowest | 10 ₹1,383 Lowest | 20 ₹2,766 | 10 ₹1,383 Lowest |
| 3.00 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) any thickness including cover fillets complete all as specified and directed. | 278.2 | Sqm | 10 ₹2,782 | 10 ₹2,782 | 20 ₹5,564 | 5 ₹1,391 Lowest |
| 4.00 | Taking down chowkhat or frame not exc 1.5 Sqm each with shutters (without taking of shutter from the frames ), complete all as specified and as directed. | 12 | Each | 100 ₹1,200 | 10 ₹120 Lowest | 50 ₹600 | 10 ₹120 Lowest |
| 5.00 | Taking down chowkhat or frame exc 1.5 Sqm but n exc 4 Sqm each with shutters (without taking of shutter from the frames ), complete all as specified and as directed. | 9 | Each | 100 ₹900 | 10 ₹90 Lowest | 50 ₹450 | 100 ₹900 |
| 6.00 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. | 9.1 | Qtl | 100 ₹910 | 10 ₹91 Lowest | 100 ₹910 | 100 ₹910 |
| 7.00 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. | 11.8 | Cum | 100 ₹1,180 | 10 ₹118 Lowest | 100 ₹1,180 | 10 ₹118 Lowest |
| 8.00 | 25mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in flooring, roof etc. complete all as specified and directed. | 177.1 | Sqm | 150 ₹26,565 | 70 ₹12,397 Lowest | 100 ₹17,710 | 150 ₹26,565 |
| 9.00 | 75 mm thick cement concrete (1:3:6), type C-2 using 40mm graded stone aggregate as in floors, hard standing, plinth protection etc and laid in alternate bays complete and finished the even & fair and providings joints through out the thickness of plinth protection filed with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed. | 80.1 | Sqm | 250 ₹20,025 | 120 ₹9,612 Lowest | 200 ₹16,020 | 320 ₹25,632 |
| 10.00 | Rendering 10 mm thick on fair face of brick work or concrete surfaces, finished even & smooth without using extra cement in CM 1:4, complete all as specified and directed. | 50.6 | Sqm | 250 ₹12,650 | 240 ₹12,144 | 210 ₹10,626 Lowest | 300 ₹15,180 |
Tender Value
₹49.7 L
EMD Value
₹99,400
Closing Date
20 Oct 2025, 6:00 pmClosed
GE 881 EWS
GE 881 EWS C/O 56 APO
PROVN OF PLATFORM, BAFFLE WALL, TWO GEN SET 15 KVA AND 01 X 2 TON AIR CONDITIONER FOR ISO CONTAINER AT HAMIRPUR AND SPL REPAIR TO BLDG NO T-37A AND T-46 (OFFICER MESS) A COY 898 BN AT BALNOI BASE IN THE AOR OF STN HQ KG AND BG UNDER GE 881 EWS
2025_MES_732168_1
GE/PNH-69/2025-26
Open Tender
Civil Works
Item Rate
GE 881 EWS C/O 56 APO
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 881 EWS
₹99,400
Yes
27 Nov 2025
23 Sept 2025
22 Oct 2025
23 Sept 2025
20 Oct 2025
7 Oct 2025
Amount
B/R PORTION: Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) any thickness including cover fillets complete all as specified and directed.
Taking down chowkhat or frame not exc 1.5 Sqm each with shutters (without taking of shutter from the frames ), complete all as specified and as directed.
Taking down chowkhat or frame exc 1.5 Sqm but n exc 4 Sqm each with shutters (without taking of shutter from the frames ), complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
25mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in flooring, roof etc. complete all as specified and directed.
75 mm thick cement concrete (1:3:6), type C-2 using 40mm graded stone aggregate as in floors, hard standing, plinth protection etc and laid in alternate bays complete and finished the even & fair and providings joints through out the thickness of plinth protection filed with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed.
Rendering 10 mm thick on fair face of brick work or concrete surfaces, finished even & smooth without using extra cement in CM 1:4, complete all as specified and directed.
Rendering 15 mm thick on fair face of brick work or concrete surfaces, finished even & smooth without using extra cement in CM 1:4 incl mixing of water proofing compound as per manufacturer's instruction, complete all as specified and directed.
Rendering 5mm thick in cement mortar (1:3) on ceiling surfaces, chajja etc and finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Complete removal of existing treatement from wall plaster and applying two coats of oil bound distemper white or any tint, complete all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper white or any tint, over and including 1 mm thick wall care putty, complete all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper white or any tint, complete all as specified and directed.
Preparation of new plastered wall surface and applying two coats of cement base paint over a coat of primer, complete all as specified and directed.
Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre,including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately), complete all as specified and directed. Note : Over lapping between lower part and upper part may upto 30cm and no additional measurement for the same to be taken. (Net measurment of room ceiling shall be given)
Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified and directed.
Hangers 6 mm dia. G.I. wire (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fastner 12.5mm dia. 40mm long complete all as specified & directed.
Vitrified ceramic tiles 8 to 9 mm thick light shade, area of each tile not exceeding 0.36sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shed of tiles, over and including 15mm thick screed bed in CM (1:4), complete all as specified and directed.
All as per item No 20 above but on skirting/dado etc over and incl 10 mm thick rendering in CM 1:6, complete all as specified and directed.
Non skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match, incl screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM (1:4) complete all as specified & directed.
Glazed cermic coloured tiles 300x450x 7mm thick on vertical surfaces of wall such as skirting/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match, incl 10mm thick rendering in CM (1:4) all tiles such as dado/skirting in vertical surface complete all as specified and as specified.
Powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and as directed.
Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps incl embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed.
Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe-290 (Gde E165), complete all as specified and directed by Engr-In-Charge.
Powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc, complete all as specified and directed by Engr-In-Charge.
Sheet glass 5.5mm thick, ordinary quality and glazing with oil putty or securing with rubber beading in squares exc 0.5 sq. m in each pane, complete all as specified and as directed.
Prelaminated particle board, 9mm thick, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, complete all as specified and as directed.
Brass mortice lock, vertical type, size 100 mm, 4 levers, complete all as specified and as directed.
Aluminium anodised barrel tower bolts of extruded section with 200 mm long bolt, complete all as specified and as directed.
Preparation of new steel or iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed.
Preparation of old steel or iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed.
Powder coated aluminium sliding glazed windows with three track shutter sliding (two shutters glazed and one shutter wire mesh) shall be two part as upper part shall be three movable shutter and lower part consist three shutter (one openable in centre and both side fixed type shutter with frosted glass) with following specification and making good the adjacent side of jambs of windows by plastering in CM 1: 3 even and smooth complete etc . shifting of existing cooler stand where required complete all as specified and as directed by Engr-in-charge. (i) Windows frame of cross section 101mm x 44mm x 1.5mm thick (ii) Three way track for sliding shutters of cross section 91.8mm x 31.75mm x1.1mm thick (iii) Sliding shutter frame of cross section 40 x 18 x 1mm thick. (iv) 4 mm thick glass superior quality (v) HDPE Rubber guasket for fixing of glass. (vi) Locking cleats per shutter -01 Nos. (vii) Sliding rollers per shutter - 02 Nos (viii) Stainless steel wire cloth 0.30mm nominal dia of wire and average width of aperture 1.40mm for shutters 01 Nos (ix) fixing screw for frame with wall per windows- 08 Nos, complete all as specified and directed.
Aluminium (extruded section) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed, complete all as specified and directed.
Stainless steel decorative curtain rod 25mm dia with decorative head on both end of rod and necessary clamps / fixing brackets, stops, rollers etc, complete all as specified and directed.
Walling of random rubble stone masonry, brought up to course, well bonded, bedded and solidly hearted built in CM 1:6, complete all as specified and directed.
All as per item No 38 above but except stone.
Raised pointing to RR masonry uncoursed brought ypto cereuses in CM 1:3, complete all as specified and directed.
Supply only liquid water proofing compound, complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
Pre-painted galvalume aluminium zinc GI based profile pattern steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engineer- in Charge. Note: The Preprinted galvalume aluminium zinc GI based profile pattern steel sheet should be, complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based profile pattern steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa, as in ridge covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Solid PVC Wall Lining consisting of 5mm thick Plain wood grain PVC sheet inclusive of solvent cement and fixing incl 'L' type edging/corner fillets, complete all as specified and directed.
5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specifiction and drawing, complete all as specified and directed.
Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook with N.R.V (Back Flow Preventer) Make Jaquar Model No ALT 577 or its equivalent in ROCA/KOHLER, complete all as specified and directed.
Single Towel Rail 600mm Long, Stainless Steel Make Jaquar Model No ACN-1111SM or its equivalent in ROCA/KOHLER, complete all as specified and directed.
Towel Ring Square with Round Flange Make Jaquar Model No ACN-1121N or its equivalent in ROCA/KOHLER, complete all as specified and directed.
Corner Shower Basket Make Jaquar Model No ACN-1175N or its equivalent in ROCA/KOHLER, complete all as specified and directed.
Single Piece Slim Concealed Cistern with Floor Mounting Frame, Installation Kit and “S-Type” Drain Pipe Connection Set for Wall Hung WC with Flush Control Plate Make Jaquar Model No JCS- T-2400FS for cistern and Model No JCP-CHR-372415 for Flush Control Plate or its equivalent in ROCA/KOHLER, complete all as specified and directed.
Toilet Roll Holder With Flap Make Jaquar Model No AQN-7753 or its equivalent in ROCA/KOHLER, complete all as specified and directed.
Wall Hung Basin With Fixing Accessories, Size: 635x485x305 mm Make Jaquar Model No ACS-WHT-87801 or its equivalent in ROCA/KOHLER, complete all as specified and directed.
Single Lever Basin Mixer with Popup Waste System & 450mm Long Braided Hoses Make Jaquar Model No VGP-81051B or its equivalent in ROCA/KOHLER, complete all as specified and directed.
Bib Cock with Wall Flange Make Jaquar Model No VGP-81037 or its equivalent in ROCA/KOHLER, complete all as specified and directed.
Angular Stop Cock with Wall Flange Make Jaquar Model No VGP-81053 or its equivalent in ROCA/KOHLER, complete all as specified and directed.
Maze overhead shower 300mm x 300mm Square shape Single flow (Body & Face Plate Stainless Steel) With Rupid Cleaning System over & including Shower Arm 400X25X25mm Square Shape for Wall Mounted Showers with Flange, Make Jaquar or its equivalent in ROCA/KOHLER, complete all as specified and directed.
Wall Mixer with Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flanges Make Jaquar Model No FUS-29273UPR or its equivalent in ROCA/KOHLER, complete all as specified and directed.
Concealed Stop Cock Regular Body Suitable for 15mm Pipe Line with Spindle Extension & Plastic Protection Cap (without Exposed Parts Make Jaquar Model No ALD-083CQT or its equivalent in ROCA/KOHLER, complete all as specified and directed.
Rimless Blind Installation Wall Hung WC With UF Soft Close Slim Seat Cover, Hinges, Accessories Set, Size: 380x520x365 mm Make Jaquar Model No ACS-WHT-87953BIUFSM or its equivalent in ROCA/KOHLER, complete all as specified and directed.
PVC(SWR) pipes, 110 mm external dia double socketed in any length with rubber joints, fixed to walls with PVC brackets/clips, complete all as specified and directed.
PVC(SWR) bends/Tees suitable for 110 mm external dia, complete all as specified and directed.
PVC (SWR) vent cowl 110mm bore, complete all as specified and directed.
PVC(SWR) pipes, 75 mm external dia double socketed in any length with rubber joints, fixed to walls with PVC brackets/clips, complete all as specified and directed.
PVC (SWR) bends suitable for 75 mm external dia, complete all as specified and directed.
Supply only Flexible waste pipe for wash hand basin fitted to Wash Hand Basin incl all necessary brackets etc, complete all as specified and directed.
PVC connection 15 mm size with PTMT nuts of length 600 mm, complete all as specified and directed.
Waste coupling, 32mm dia, of PTMT (half or full threaded) .(Minimum weight 32mm-45gms/40mm-60 gms), complete all as specified and directed.
Supply and fixed in repair glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm widow with chromium plated bracket guard and railing 60 cm long, complete all as specified and directed.
Nipple 20mm dia suitable for HDPE water tank. (Minimum weight 20mm - 45gms), complete all as specified and directed.
S&F repair Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 20 mm bore and fixed in repairs, complete all as specified and directed.
S&F in repair Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 20gm - 210 gm), complete all as specified and directed.
PVC 500 litre capacity, triple layered polyethylene water storage tanks with threaded lead (cylindrical vertical with closed top) including hoisted and fixed in position, making connections, complete all as specified and directed.
S & F in repair 15 mm bore of tube medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors, complete all as specified and directed.
S & F in repair 20 mm bore of tube medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors, complete all as specified and directed.
Vanishing Blinds with Vinyl coated fibreglass fabric laminated with two-ply 100% PVC blackout film (of Revolving Blackout Type and grade 2000 series with RB-07 of SD Blinds make or equivalent make and having same colour, shade and texture). Fire classification of fabric NFPA 701-2004 (small scale), BS 5768-2008 Part 2 Type B Performance Fabric should be Bacterial & Fungus fee, Green guard & Lead free, normal thickness of fabric shall be 0.50mm and minimum weight 255gsm, hanging excellent hanging properties and very high tear strength. The fabric shall be suspended from the top channel made of extruded alloy of 1.25mm nominal thickness and 38mm nominal diameter. The top channel shall be fixed with powder coated mild steel bracket with clutch assembly on either end of blind, fixed to jambs of the window opening with 50 mm stainless steel screw with nylon roll plug and to the aluminium window with 25mm self thread screw. The operating mechanism shall be operated with plastic ball chain having 4.50 mm balls made of ABS plastic linked with 1.50 mm polyester cord. The mechanism shall allow the blind to stop in desired position with the clutch mechanism. The bottom channel shall be made of rectangle shape with extruded aluminium tube with powder coating. The fabric shall be enclosed in suitably created pocket along the tubes, which shall be closed from side with end caps of same colour to the bottom roller. All exposed components of roller blind shall be of milky white colour, complete all as specified and directed.
Surface excavation not exceeding 30cm deep and average 15cm deep and getting out in hard/dense soil, complete all as specified and directed.
PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc. finished even & fair, complete all as specified and directed.
Keyed pointing to RR or uncourced or poligonal or brought utpo course in CM 1:4 complete all as specified and directed.
100mm thick PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) as in surface finished even and smooth with using extra cement etc complete all as specified and directed.
PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
Hard core of broken stone/boulders of gauge n exc 63mm deposited spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
S&F in repair PVC (SWR) pipes 110mm dia any length single socketed with rubber ring joint, laid in floor/wall/weep holes, complete all as specified and directed.
E&M PORTION:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
M&L for point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :-
One light/fan point controlled by one way switch 6 Amp complete all as specified and directed.
One 3/5 pin socket outlet 6 amp on same board complete all as specified and directed.
One 3/5 pin socket outlet 6 amp independent board complete all as specified and directed.
All as per srl item No 86 here in before but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 2.5 Sqmm as in continuous earth wire complete all as specified and directed.
S&F Sub main wiring with single core cable 2x 4 Sqmm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including suitable size PVC casing capping medium grade ISI marked alongwith 1x 4 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly, incl dismantling old wiring and making good the surface by plastering and 2 coats of existing paint/colour complete all as specified and directed. Note:-Three wire of 4 sqmm and one run of PVC conduit/casing caping shall be measured as one unit.
S&F switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed.
Socket outlet 2 in 1, 3 pin, 5 Amp flush type universal, complete all as specified and directed.
Switch piano flush type 15 Amp single pole one way, (ISI marked), complete all as specified and directed.
Socket outlet 2 in 1, 3 pin, 15 Amp flush type universal, complete all as specified and directed.
Ceiling rose, 3 terminal, surface bakelite 65 mm x 50mm, PVC/poly carbonate, insulated body, complete all as specified and directed.
Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
Stepped type electronic fan regulator speed regulation in 5 step flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed.
LED inverter lamp, CDL, 9/10 watt, B22 base, complete all as specified and directed.
Supply and fixing in repair inverter LED batten 1x 20W, with square profile and polycarbonate channel, lithium iron battery with charging time of 8 to 10 hours and backup tile upto 04 hours with driver, holder incl LED tube light connecting up with with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing in repair mounting 12 Watt LED sliim circular downlighter with highely efficent LED & glare free opal diffuser in round shape incl connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed.
Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, vertical TPN double door (IP43), 4 ways built in bus bars suitable for 415 volts, AC, 50 Hz and suitable for FP MCCB as incommer and out going SP/TP MCBs complete all as specified and directed. Note:- MCBs shall be measured and paid separately.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 8 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair MCB SPN 63 amps 240 volts 10 KA 'B' curve, finger proof terminal, bi-connect termination, label holder, 35 Sqmm terminal capacity, insulating sliding shutter large two position dolly, ISI marked, complete all as specified and directed.
S&F in repair MCB SPN 40 amps 240 volts 10 KA 'B' curve, finger proof terminal, bi-connect termination, label holder, 35 Sqmm terminal capacity, insulating sliding shutter large two position dolly, ISI marked, complete all as specified and directed.
S&F in repair MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series, complete all as specified and directed.
Heavy duty metallic exhaust fan 300 mm sweep 1400 RPM, single phase 230 Volts including all connecting accessories, complete and taking out old existing exhaust fan, complete all as specified and directed.
Providing opening and grouting the nuts and bolts for fixing of exhaust fan in wall incl civil work as required on site and making good the disturbed surface, complete all as specified and directed.
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades, complete all as specified and directed.
Removing of old burnt winding of ceiling fan any size, type and rewinding with the same gauge of copper winding wire as well as number of turns and reassembling the fan after replacing the unserviceable spares like bushes, shafts, fasteners, bearings, capacitors and flexible cord and make the fan in serviceable condition incl refixing the same to original place after carrying out necessary repair, complete all as specified and directed.
Painting to ceiling fans and writing of MES No on fan, in situ with synthetic enamel paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc, complete all as specified and directed.
Taking out old unsv ceiling fan from site of capacity 1200/1400 mm sweep and replacement with ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) incl all connecting accessories complete all as specified and directed by Engineer-in-charge.
Electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, complete all as specified and directed.
Supply and laying, jointing and testing, 1100 volts grade armoured, heavy duty XLPE electric cable with aluminium conductor of size 16 Sqmm 4 core, laid in trenches/on floor/pole or under road/culvert incl taking out old unsv cable, complete all as specified and directed. Note: Excavation shall be measured and paid separately
Supply and fixing in repair energy efficient LED light fitting 35 W, input voltage 110V to 280VAC, 50 Hz with ingress protection IP66, LM 80, standard luminaries with efficiency 100 lumen/watt with secondary optics, perfectly matched lenses, complying to IEC60598/IS10322, with auto shut down on high voltage, CRI>70,PF>0.95, with short circuit & reverse circuit protection against 10kV high surges, minimum 25000 burning hours (life), operating temperature 1 to 50oC, rectangular shape with pressure die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 45W=10%W, rated lumens, 120 degree view angle, constant current type driver having THD<10%, including all fixing arrangement like clamps, nuts, bolts, washers, 45W LED rod lamp (having PF>0.9, input voltage 90-300V, IP-66, LM80) with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. including bracket complete all as specified and as directed.
S&F in repair MCCB, 4 Pole, 415 V, fixed type, 63 Amps with breaking capacity 10 KA complete all as specified and directed.
Supply and laying, jointing and testing, 1100 volts grade armoured, heavy duty XLPE electric cable with aluminium conductor of size 25 Sqmm 4 core, laid in trenches/on floor/pole or under road/culvert incl taking out old unsv cable, complete all as specified and directed. Note: Excavation shall be measured and paid separately
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth in any type of soil, complete all as specified and directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and as directed. Note : Punned down thickness shall be measured
Removal of excavated material to a distance exc. 50 m but not exc 1.5 m and depositing where directed at a level not exceeding 1.5 mtr above starting point, complete all as specified and directed by Engineer-in-charge.
Sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete all as specified and directed. Note:- 1.Dry fine sand of best available quality shall be used. 2.Punned thickness shall be made and paid.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
Making bore to road/cement path/hardstanding/road for providing GI pipe 40 mm, both end socketed for passing armoured cable, incl making good the surface light grade galvanised with all fitting and fixed to wall/ceiling or laid in floor complete all as specified and directed.
S&F in repair tubes 40 mm, light grade galvanised with all fitting and fixed to wall/ceiling or laid in floor complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600x 600x3.15mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all side and incl connected to and incl galvanized iron wire as earth lead 4.0mm size upto 7.5 mtr long by means of nuts and bolts, check nuts and washers of brass and connected to earthing test point and earth dolly all as shown in electrical plate No 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:3:6 type C-1 chamber pre-cast RCC slab 50mm thick in cement concrete (1:2:4), type B1, reinforced with welded steel wire fabric or XPM, (weight not less than 4Kg per Sqm) with cast iron frame, funnel with watering pipe 15mm dia medium grade, wire mesh and lugs, GI protection pipe 15mm dia light grade, 7.5mtr long for protection of earth lead upto test point etc, including testin on completion, complete all as specified and directed.
M&L for Point Wiring using approved colour coding as per IS with Zero halogen flame retardent (HFFR) smoke free non toxic non corrosive with copper cable 1.5 sqmm (nominal area) single core insulated and unsheathed stranded cable 1100 Volts grade and including (ERW) stove enamelled conduit heavy duty ISI marked and unsheathed copper conductor complete all as specified and directed for light point controlled by one way switch, complete all as specified and directed.
All as per item No.128 here-in-before but with 2.5 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor, complete all as specified and directed.
All as per item No. 128 here-in-before but with 4 Sqmm for 3 pin 25 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor, complete all as specified and directed.
Flame proof weather proof switch socket & plug combined 16 A 250V (2P + earth), complete all as specified and directed.
Flame proof weather proof switch socket & plug combined 25 A 250V (2P + earth), complete all as specified and directed.
Submain wiring with 4 runs of copper conductor FRLSH PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through Steel conduit 25mm dia ISI marked as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm FRLSH multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified. Note : Four runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length, complete all as specified and directed.
LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Switch flame Proof rotary type with termination box in LM-6 16 A single Pole 240 V, complete all as specified and directed.
Switch flame Proof rotary type with termination box in LM-6 25 A single Pole 240 V, complete all as specified and directed.
Flame proof sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 8 way flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed.
MCBs 5 to 40 amp SPN C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB, complete all as specified and directed.
MCBs 5 to 40 amp SP C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB, complete all as specified and directed.
Supply, laying, jointing and testing in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 35 Sqmm complete all as specified and directed .
Engine Control Panel : (a) All relevant parameters shall be conventionally displayed on complete panel thereby providing easy monitoring of lub oil, pressure, Coolant Temperature, Battery charging, Ammeter, RPM, Hour meter and starting switch etc. (b) AMF Panel with Bye Pass arrangement for Main and DG Both supply, internal wiring and power contactors suitable for 15 KVA generator set, all as per manufacturer's recommendation. Bye Pass arrangement Main & DG set Supply along with all the parameters and accessories as per manufacturer's recommendation and CPRI Approved & as per relevant IS. Fuel Tank : Fuel Tank of 12 hours capacity will be installed as per the manufacturer's requirement including all necessary pipe connections from fuel tank to engine and over flow from engine to tank
Engine Alternator Engine Alternator of capacity 15 KVA output 3 Phase 50 HZ 415 Volts 4 wire AC supply 0.8 Power Factor at 1500 RPM self regulated self excised screen protected and drip type, insulation class 'H' continously rated brush less type conforming to relevant BS/ IS code as per current manufacturing shedule of standard manufacturer. Engine Alternator shall be mounted on specially designed base plate of rigid welded constructions with anti vibraton pads. The DG Set shall be placed on foundation including necessary civil works as per the manufacturer's recommendations/site requirement. The output of alternator not less than 15 KVA in all adverse conditiones, as the DG set to be installed at HAA 950 m above MSL. Note:- (a) The unit rate shall deemed to include the cost of Diesel and lubrication required for testing and commissioning of DG Set as per department procedure and shall be arranged by contractor. (b) Extenssion of exhaust pipe for DG set along with standerd accessories like flange, nut bolts , asbestous rope etc. shall be provided by the contractor and the cost of the same shall be included in the unit rate quoted by contractor. (c) Cost of foundation and necessary civil works as per the manufacturer's recommendations/site requirement shall be incuded in the unit rate quoted by the contractor.
GI tubing 50mm bore light grade galavanised with all fitting complete for cable protection under road crossing/on pole/wall or similar position, complete all as specified and directed.
M&L for making bore to road/cement path/hardstanding/road for providing GI pipe 50 mm, both end socketed for passing armoured cable, incl making good the surface light grade galvanised with all fitting and fixed to wall/ceiling or laid in floor complete all as specified and directed.
Double wall corrugated pipe (DWC) of 75mm dia conforming to IS: 16205 part-24 and IES 61386 (Part-24) for cable protection of cable under/ above ground surface complete all as specified and directed.
End jointing kit for 1.1 KV grade suitable for outdoor type terminal heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 35 Sqmm complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including galvanized earth lead strip 32x6 mm size upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thick in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point including testing on completion etc all as specified and as directed.
Supply and install hi wall Flameproof split AC units indoor/outdoor complete with cordless remote control unit and with in-built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5TR complete all as specified and directed. Note :- The rates of insulated copper pipe upto 10mtr from indoor to outdoor unit of Split AC are deemed to be included in quoted rates.
Submain wiring with 2 X 4 Sqmm + 1 x 4Sqmm earth wire of copper conductor Zero halogen flame retardent (ZHFR) smoke free non toxic non corrosive with copper cable insulated unsheathed cable 1100 volt grade 4 sqmm drawn through Steel conduit 25mm dia ISI marked as per IS specification fixed on wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm ZHFR multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified. Note : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length
Flame proof weather proof receptable with MCB 20A & top plug having protection IP 54, fixed in wall, complete all as specified and directed.
Flameproof Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA, complete all as specified and directed.
VIKAS ENTERPRISES (BID ID -3448993)
M/S RAHUL GUPTA (BID ID -3455465)
JAMWAL CONSTRUCTION CO (BID ID -3449987)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
BOQ_819755.xls
BOQ • 2.61 MB
TENDER69.pdf
Tender Documents • 1.68 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .