| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 CrAdmitted-Finance 10TH FLOOR UNIT 2 TECHNIPLEX 2 VEER SAVARKAR FLYOVER S V ROAD GOREGOAN WEST MUMBAI 400 062 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400062 | ₹3.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.0 Cr+₹12.2 L (3.16%)Admitted-Finance | ₹4.0 Cr+₹12.2 L (3.16%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | BRITE INDUSTRIES L2 | VAV Airconditioning L1 |
|---|---|---|---|---|---|
| 1.00 | Total of Part A | 1 | no | 1,71,13,162 ₹1,71,13,162 Lowest | 1,77,21,006 ₹1,77,21,006 |
| 2.00 | Total of Part B | 1 | no | 28,31,818.98 ₹28,31,818.98 | 16,13,281 ₹16,13,281 Lowest |
Tender Value
₹1.6 Cr
EMD Value
₹3.1 L
Closing Date
9 Aug 2024, 3:00 pmClosed
Director,TMC
Office of Engineering services, Second Floor,Khanolkar Shodhika , ACTREC Kharghar Node, Navi Mumbai - 410210
MEP work of Immunodeficient Animal Research Facility at ACTREC
2024_TMC_812502_1
ET-37/MEP Work/2024
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
180 days
ACTREC, Kharghar
As per Tender Document
2 documents required · 2 mandatory
₹0
₹3.1 L
ACTREC,Kharghar
2 Dec 2024
19 Jun 2024
12 Aug 2024
19 Jun 2024
9 Aug 2024
19 Jun 2024
19 Jun 2024 - 26 Jun 2024
27 Jun 2024
Amount
Total of Part A
Total of Part B
Description of Work / Item(s)
Amount
HIGH SIDE EQUIPMENT
Supply, Installation, Testing & Commissioning of Heavy duty C class Piping (with necessary clamps, vibration isolators and fitting but excluding valves, strainer, gauges etc.). The pipe of size 150mm & below shall be M.S.'C' class as per IS 1239 and pipe size above 150mm shall be welded black steel pipe heavy class as per IS:3589, from minimum 6.35mm thick M.S sheet for pipes upto 350mm dia. The Pipe surface to be clean with wire brushing throughly before applying two coats of Zinc Chromate primer. Pipe should include, Bends, Elbows, TEE joints, Tapping, Flanges, reducers and there fabrication with Nut bolts washers, gaskets and fitting of valves and all accessories etc. Piping should also include Puff supports, and necessary support required etc.
Supply& Installation of Chilled water piping Insulation of 32 mm thk Puf Insulation f Density Not less than 40Kg/m3. The insulation shall be available in self-seal (pre-slit and pre-glued) pre-formed tube type for pipe diameter upto 4 inches. For pipe diameters above 4 inches factory-cut sheet insulation to match the pipe OD should be used. The Adhesive to be used as recommended by Manufacturer. The Application will be executed strictly as Specified by manufacturer. The Insulated Pipe shall be with 26 gauge aluminium Cladding. (Vendor to verify site length and Insulation suitable for Chilled water service) All the Chilled water valves and Accessories to be provided with insulation.
Supply, Installation, testing & Commissioning of 150# C.S.Ball Valve with Extended spindle to take care the Insulation Thickness as per Following Sizes.All Valves will be Insulated using 32 mm thk Puf Insulation f Density Not less than 40Kg/m3 and 26 gauge aluminium Cladding.
Supply, Installation, testing & Commissioning of Butterfly Valve with C I body SS disc, nitril rubber seal & O ring PN-16 rating with Extended spindle to take care the Insulation Thickness as per Following Sizes.All Valves will be Insulated using 32 mm thk Puf Insulation f Density Not less than 40Kg/m3and 26 gauge aluminium Cladding.
Supply, Installation, testing & Commissioning of Differentail Pressure transmitter of water to control the flow.
Supply, Installation of industrial Dial Type Pressure Gauge with Alumnium Die cast body and all internal working parts are of SS 304 construction and along with SS syphon of approved Make & Range 0-10 Kg/cm2 Connection Size 25NB Dial Size 150/100mm with SS investment casting ball valve.
25 NB----150mm dial Dia (for Header piping)
Supply, Installation of Dial Type Compound Gauge the of approved Make & Connection Size 25NB Dial Size 150mm with all necessary hardware and asscessories including Valve.
Supply, Installation of industrial Dial Type Temp. Gauge with Alumnium Die cast body and all internal working parts are of SS 304 construction and along with thermowell of approved Make. Connection Size 15NB Dial Size 150/100mm with SS investment casting ball valve.
15 NB (Range 0-30 Deg. Centigrade) ----150mm dial Dia (for Header piping)
Supply, Installation, testing & Commissioning of Auto Air Vent Size.
Supply, Installation, testing & Commissioning of Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe with insulation & PN16 pressure rating. All Valves will be Insulated using 32 mm thk Puf Insulation f Density Not less than 40Kg/m3 and 26G Aluminium cladding Supply should include the required tubing and isolation valves so that the differential pressure may be measured across the Valve.
LOW SIDE
Supply, Installation, Testing & Commissioning of AHU-01 for Ante Room, NSG Misc Exp. & Imaging Zone
Double skin Horizontal / Vertical Air Handling unit will be Eurovent/AHRI certified and having following specifications
Construction
Thermal Bridging: TB2
Casing Strength: D1
Casing Leakage: L1
Thermal Transmittance: T3
Filter Bypass Leakage: F8
Material of Construction
Casing Details:
Outer skin 0.8MM thick pre coated GSS
Inner skin: 0.8mm Alu Zinc sheet
Framework: Extruded aluminum alloy
Drain Pan: Single skin 18 G Stainless steel with 13mm thick Nitrile rubber insulation with slope to avoid water retention
Insulation: Polyurethane foam
Panel thickness: 50mm
CHW & Coil details:
Coil casing blank off: Galvanized Steel sheet
Material of tube: Copper (Plain)
Tube dia: 12.7mm (0.5inch)
Thickness of tube:20guage
Header material: MS header with MS End connection
Fin material: 0.2mm Plain Aluminum with hydrophobic coating
Number of fins: 12FPI to 14 FPI
Filter details:
Make of filters: Thermadyne/ Freudenberg
Filter media: Synthetic non-woven for EU4 & EU7
Filter efficiency EU4: : 90% Efficient down to 10micron
Filter efficiency EU7: : 99% Efficient down to 3micron
Unit Configuration
1. Mixing box section with manually operated FA damper with EU-4 filters.
2. Pre Filter section with 50mm thick EU-4 filters.
3. Pre cooling coil section with 6 row deep (12.7mm OD copper tube) CHW cooling coil with Hydrophilic coating
4. Cooling coil section with 8 row deep (12.7mm OD copper tube) CHW cooling coil with Hydrophilic coating
5. UV section with UV Light., Pureair
6.Min. 2 pass SS Moisture Eliminator (Removable sliding type arrangement)
7. Electric Strip Heaters, and Air flow sensor
8. Fan section with Kruger Plug fan with TEFC sq. cage induction motors make IE3 IP 55 having antivibration isolators, anti microbial rexine connector at fan discharge.
9.Air flow switch
10.The fan section will have limit switch, marine lamp & view window
11. Fine filter section with 300mm thick EU-7 filter.
12. Supply air plenum with manually operated Al damper.
13. Canvas connection required for Fan and Connection for Supply & return duct from AHU to be included.(All the internal cable require in the AHU to be considered no additional cost will be given for the same,)
AHU-01-2000 CFM @ 150mmwc, 18.71 TR, 9 Kw Heater
Supply, Installation, Testing & Commissioning of AHU-02, 03 & 04 for NUDE mice, SCID mice experiment, Clean Corridor & food storage
Double skin Horizontal / Vertical Air Handling unit will be having following specifications
Construction
Thermal Bridging: TB2
Casing Strength: D1
Casing Leakage: L1
Thermal Transmittance: T3
Filter Bypass Leakage: F8
Material of Construction
Casing Details:
Outer skin 0.8MM thick pre coated GSS
Inner skin: 0.8mm Alu Zinc sheet
Framework: Extruded aluminum alloy
Drain Pan: Single skin 18 G Stainless steel with 13mm thick Nitrile rubber insulation with slope to avoid water retention
Insulation: Polyurethane foam
Panel thickness: 50mm
CHW & Coil details:
Coil casing blank off: Galvanized Steel sheet
Material of tube: Copper (Plain)
Tube dia: 12.7mm (0.5inch)
Thickness of tube:20guage
Header material: MS header with MS End connection
Fin material: 0.2mm Plain Aluminum with hydrophobic coating
Number of fins: 12FPI to 14 FPI
Filter details:
Make of filters: Thermadyne/ Freudenberg
Filter media: Synthetic non-woven for EU4 & EU7
Filter media: Submicronic glass fiber for EU13
Filter efficiency EU4: : 90% Efficient down to 10micron
Filter efficiency EU7: : 99% Efficient down to 3micron
Filter efficiency EU13: : 99.997% Efficient down to 0.3micron
Filter media: Submicronic glass fiber for EU13
Unit Configuration
1. Mixing box section with manually operated FA damper with EU-4 filters.
2. Pre Filter section with 50mm thick EU-4 + 300 mm thick EU-7 filters.
3. Pre cooling coil section with 6 row deep (12.7mm OD copper tube) CHW cooling coil with Hydrophilic coating
4. Cooling coil section with 8 row deep (12.7mm OD copper tube) CHW cooling coil with Hydrophilic coating
5. UV section with UV Light., Pureair
6.Min. 2 pass SS Moisture Eliminator (Removable sliding type arrangement)
7. Electric Strip Heaters, and Air flow sensor
8. Fan section with Kruger Plug fan with TEFC sq. cage induction motors make IE3 IP 55 having antivibration isolators, anti microbial rexine connector at fan discharge.
9.Air flow switch
10.The fan section will have limit switch, marine lamp & view window
11. Fine filter section with 300mm thick EU-7 filter.
12. Supply air plenum with manually operated Al damper.
13. Canvas connection required for Fan and Connection for Supply & return duct from AHU to be included.(All the internal cable require in the AHU to be considered no additional cost will be given for the same,)
AHU-02-7000 CFM @ 130mmwc, 63.39 TR, 33.26 Kw Heater
Supply, Installation, Testing & Commissioning of AHU Exhaust unit
Double skin Horizontal / Vertical AHU Exhaust unit will be Eurovent/AHRI certified and having following specifications
Construction
Thermal Bridging: TB2
Casing Strength: D1
Casing Leakage: L1
Thermal Transmittance: T3
Filter Bypass Leakage: F8
Material of Construction
Casing Details:
Outer skin 0.8MM thick pre coated GSS
Inner skin: 0.8mm Alu Zinc sheet
Framework: Extruded aluminum alloy
Insulation: Polyurethane foam
Panel thickness: 50mm
Filter details:
Make of filters: Thermadyne/ Freudenberg
Filter media: Synthetic non-woven for EU4
Filter media: Submicronic glass fiber for EU13
Filter efficiency EU4: : 90% Efficient down to 10micron
Filter efficiency EU13: : 99.997% Efficient down to 0.3micron
Unit Configuration
1. Return Air section with manually operated damper.
2. Pre Filter section with 50mm thick EU-4 filters.
3. Fan section with Kruger backward curve DIDW centrifugal fan with TEFC sq. cage induction motors 2Nos (1working +1 Standby) make IE3 IP 55 having belt drive, antivibration isolators, anti microbial rexine connector at fan discharge
4.Air flow switch
5.The fan section will have limit switch, marine lamp & view window
6. Fine filter section with 300mm thick EU-13 filter.
7. Exhaust air plenum with manually operated Al damper.
8. Canvas connection required for Fan and Connection for Supply & return duct from AHU to be included.
AHU-01-EX- 2000 CFM @ 75mmwc
AHU-02-EX- 7000 CFM @ 75mmwc
Supply, Installation, Testing & Commissioning of VS-01 for Return Cooridor
Double skin Horizontal / Vertical Ventilation Supply unit will be Eurovent/AHRI certified and having following specifications
Construction
Thermal Bridging: TB2
Casing Strength: D1
Casing Leakage: L1
Thermal Transmittance: T3
Filter Bypass Leakage: F8
Material of Construction
Casing Details:
Outer skin 0.8MM thick pre coated GSS
Inner skin: 0.8mm Alu Zinc sheet
Framework: Extruded aluminum alloy
Insulation: Polyurethane foam
Panel thickness: 50mm
Filter details:
Make of filters: Thermadyne/ Freudenberg
Filter media: Synthetic non-woven for EU4 & EU7
Filter efficiency EU4: : 90% Efficient down to 10micron
Filter efficiency EU7: : 99% Efficient down to 3micron
Unit Configuration
1. Fresh Air section with manually operated FA damper.
2. Pre Filter section with 50mm thick EU-4 filters.
3. single stage Indirect type pre-cooling arrangment along with Heat exchanger, pump and required accessories.
4. UV section with UV Light., Pureair
5. Fan section with Kruger backward curve DIDW centrifugal fan with TEFC sq. cage induction motors 2Nos (1working +1 Standby) make IE3 IP 55 having belt drive, antivibration isolators, anti microbial rexine connector at fan discharge
6.Air flow switch
7.The fan section will have limit switch, marine lamp & view window
8. Fine filter section with 300mm thick EU-7 filter.
9. Supply air plenum with manually operated Al damper.
10.Unit ot be provided along with the control panel and necessary cabling upto unit blowers and pumps. Pump level control to be provided along with necessary accesories.
11.Unit ot be provided along with the control panel and necessary cabling upto unit blowers and pumps. Pump level control to be provided along with necessary accesories. Control panel to be mounted on black color M.S stand of 1200mm height.
12. Canvas connection required for Fan and Connection for Supply & return duct from AHU to be included.
Supply Grill Temp. at room 5°C less than the ambient temp.
VS-01- 3000 CFM @ 75mmwc
Supply, Installation, Testing & Commissioning of VE-01 for Return Cooridor
Double skin Horizontal / Vertical Ventilation Exhaust unit will be Eurovent/AHRI certified and having following specifications
Construction
Thermal Bridging: TB2
Casing Strength: D1
Casing Leakage: L1
Thermal Transmittance: T3
Filter Bypass Leakage: F8
Material of Construction
Casing Details:
Outer skin 0.8MM thick pre coated GSS
Inner skin: 0.8mm Alu Zinc sheet
Framework: Extruded aluminum alloy
Insulation: Polyurethane foam
Panel thickness: 50mm
Filter details:
Make of filters: Thermadyne/ Freudenberg
Filter media: Synthetic non-woven for EU4
Filter efficiency EU4: : 90% Efficient down to 10micron
Unit Configuration
1. Return Air section with manually operated damper.
2. Pre Filter section with 50mm thick EU-4 filters.
3. Fan section with Kruger backward curve DIDW centrifugal fan with TEFC sq. cage induction motors 2Nos (1working +1 Standby) make IE3 IP 55 having belt drive, antivibration isolators, anti microbial rexine connector at fan discharge
4.Air flow switch
5.The fan section will have limit switch, marine lamp & view window
6. Exhaust air plenum with manually operated Al damper.
7. Canvas connection required for Fan and Connection for Supply & return duct from AHU to be included.(All the internal cable require in the AHU to be considered no additional cost will be given for the same,)
VE-01- 3000 CFM @ 50mmwc
Supply, Installation, Testing and Commissioning of Prefabricated Ducting in L types. ( Prefabricating Ducting means duct fabrication on CNC machines ) Ducting will have M.S. Angle Flanges with Food Grade Epoxy based primer, followed by Food Grade epoxy black colour, with Food Grade Rubber Gasket 5mm EPDM to be used between MS flange. All Ducting seam to be sealed with Food Grade RTV Sealent. All Necessary duct support are part of the Duct Installation. (The Site Fabrication ducting qty should not increase more than 10% of the total qty. ). All Ducting to prepared at factory in L type shape along with MS flanges.Aluminum Cladding to be provided for Exposed ducting. Leak testing of Supply and return duct as per DW-143 standard Leak testing Machine to have printing facility. Duct Construction shall be in compliance with relevant static norms as per SMACNA 2” Static pressure for Lab area & 3” Static Pressure for clean room area norms to be followed.
0.63 mm thick duct
0.81 mm thick duct
1.00 mm thick duct
19 mm thick - For Supply Duct
13 mm thick - For Return Duct
Supply installation of Fiber Glass or GlassWool acoustic insulation of minimum 1mm thickness to be provided inside duct to reduce noise.
Supply, Installation, Testing and Commissioning of Non Walkable/ WalkableWalkable False Ceiling mounted Terminal Hooded filter box assembly complete with Minipleat HEPA Filter (H-14), HEPA Filter to be Factory Tested 100 % by Auto Scan Method for Particle Penetration. The base filter box to be made from 12 swg (2.5mmthk) Aluminum Extruded section duly powder coated. The Hepa filter to be designed for Maximum Velocity of 150 FPM at less then 15 mm initial pressure drop, with Gel type Sealing Arrangement along with 16 swg SS-304 Perforated sheet (Min. 70% Perforation area) . The Filter Housing will have Provision of ports, For Differential Pressure Measurement, for Aerosol Injection and Measurement and for Provision for Aerosol Distribution assembly (for Uniform Distribution). The HEPA Filter Module shall have bottom operable in built Extruded Aluminum Low Leakage Aerofoil Volume Control Dampers with bevel gear arrangement housed in a box. The filter will be bottom loading type. (Including PUF Insulation filling around the filter Box and Partition Gap.) Minimum Media pack Depth should be 100mm. HEPA box Depth should be minimum 150mm.
450 mm x 450 mm filter face area
Supply, Installation, Commissioning of removable core, Al. Epoxy Powder Coated Supply / Return Air Ceiling Diffusers of powder coated aluminum construction. Diffuser to be fixed in the 20swg GI plenum box along with powder coated volume control damper. The outer ring and the cores shall be 1 piece pressed type without any hair line crack.(The plenum box shall be measured in ducting quantity. The plenum box shall be of 100mm height.)
SqM. Rate of Diffuser
Supply, Installation, Commissioning of removable core, Al. Epoxy Powder Coated Supply / Return Air Ceiling grills of powder coated aluminum construction. Grill to be provided with powder coated volume control damper.
SqM Rate of Grilles
Supply, Installation, Commissioning of removable core, Al. Epoxy Powder Coated Supply / Return Air Ceiling grills of powder coated aluminum construction. Grill to be provided with powder coated volume control damper and inbuilt terminal heater and controller. The Terminal Heater to be along with the necessary cabling and accessories required with controller.
SqM Rate of Grilles
Supply, Installation,Testing, CommissioningExtruded Aluminum Low Leakage Aerofoil Design Volume Control Dampers suitable for Manual & Motorised operation for Filters & Risers (Suitable for Actuator installation at latter stage). Dampers should have percentage open marking, locking in position and sealing arrangement.
SqM Rate of Damper
Supply, Installation, Testing and Commissioning of UL listed Fire Dampers. Fire damper to be operated through Temp. sensor and / or Smoke sensor. The closing of the fire damper shall be through on/off type actuator along with controller and blade position indicator. (Fire Damper to be considered in Supply as well as return of AHU). Supply of smoke sensor in the scope of LV vendor.
Damper
Actuator
Magnehlic Guages - (-50 to +50mm) Range for Room to be installed in clean room partition cutout with SS 304 cover having brush finsih with High and Low Side Pressure Ports and Tubing. sensing Probe to be in ss 304 quality with SS 304 plate on Partition side to be part of the items.(Based on design the requirement might be positive or negative type.) Magnehelic guages installation to be inside wall, as per instruction provided by client.
Supply, Fabrication, Installation and Testing of Chilled Water manifold for AHU, manifold consists of
MS C Class Pipe with Fittings - 16RMT
Extended spindle Ball Valve / Butterfly valve- 5 Nos flanged End
2-Way Pressure Independent balancing & Control valve (PIBCV) with Actuator and all Accessories - 1 Nos Flanged end
Y strainer with SS/Bronze mesh - 1 Nos Flanged End
Auto Air vent with 15mm ball valve - 1 Set
Drain Valve - 1 Nos 25 NB
4'' Dial Pressure Gauge 0-7kg/cm2 - 2 Nos With syphon and ball valve
Temperature Gauge with thermowell (range 0-100C) - 2 nos
Pipe Insulaton:32 mm thk Puf Insulation f Density Not less than 40Kg/m3. The insulation shall be available in self-seal (pre-slit and pre-glued) pre-formed tube type for pipe diameter upto 4 inches. For pipe diameters above 4 inches factory-cut sheet insulation to match the pipe OD should be used. The Adhesive to be used as recommended by Manufacturer. The Application will be executed strictly as Specified by manufacturer. The Insulated Pipe shall be with 26 gauge aluminium Cladding.
U-Loop along with drain valve & Funnel to be supplied as part of manifold.
Factory manufactured Pipe section upto 80mm to be used for manifold insulation
Manifold to be marked with arrows reflecting the direction of water flow for both supply and return along with system no.
The entire manifold assembly to be factory fabricated upto isolation valves.
Tentative Size of Manifold is given below final Manifold size will be as per manufacturerer requirement. Manifold to be as per AHU manufacturer requirement
Tapping required for the manifold will be part of the manifold irrespective of the length of tapping required.
Manifold upto 40 mm to be with Ball Valve and above 40 mm to be Butterfly Valve.
50 mm (FOR AHU-01)
100 mm (FOR AHU-02 )
AHU Electrical Panel
Supply, Installation and Commissioning of Power Panel for AHU with MCCB - 4 pole (25 KVA Rating ) of Suitable Range as Isolator along with VFD and By Pass DOL / Star Delta Starter ( Upto 7.5 KW DOL starter above Star Delta). All VFD out put should have Contactors. The Panel will have Cooling Fan arrangement with Guard and Drawing Folder Provision. The Panel to be Fabricated from 16swg sheet duly powder coated of RAL Shade 7032, inlcuding Cabling from Control panel to AHU Motor, Exhaust Motor, UV light etc.Differential Pressure Transmitter compatible with Instrumented Inlet Ring at suction of blower to be provided along with control panel with control wiring upto VFD panel. Cabling from control panel to AHU will be in contractor scope irrespective of length of the cable required, Suitable control cabling to be considered. The Cables used should be Copper up to 10 sq.mm and Aluminum cable above 10 sq.mm. Armoured XLPE Cables to be used. The schematic drawing of Panel is indicated in the Tender. The Type of switch gear to be as per Client requirements. Thyristor based controller to be provided for heater control. Control Panel internal wiring to be carried out in 2.5 mm2 copper wires FR grade. Wires will be terminated to connector strip (Stud Type Connectors for Power Terminals) by using pin type lugs with Ferules. AHU/Ex/heaters/UV light etc. to have interlock wherever applicable. 20% additional potential free contact to be provided for BMS integration.Control Panel to be mounted on black powder coated MS stand. Electrical panel to have necessary controls for remote self Iluminating push button panel. AHU motor and exhaust motor to have VFD. Cabling from AHU to Control panel will be in contractor scope irrespective of length of the cable required.Suitable quantity of cabling to be included in the costing. Panel to be of IP54 rating. Indivisual Panel to be provided for indivisual AHU (Supply unit & Exhaust Unit)
AHU-01-SUPPLY MOTOR- 5HP,, HEATER- 12.08HP
AHU-02-SUPPLY MOTOR-10HP, HEATER- 44.65HP
AHU-01-EXHAUST MOTOR-2HP
AHU-02-EXHAUST MOTOR-5HP
Supply, Installation and Commissioning of Power Panels for Ventilation Supply & Exhaust units with MPCB as Isolator with Star Delta/ DOL starter with Single Phase Preventor. The Panel will have Cooling Fan with Guard and Drawing Folder Provision. The Panel to be Fabricated from 16swg CRCA sheet duly powder coated including cabling from control panel to supply and exhaust motor upto 6 mtrs. (Upto 7.5 KW DOL starter above Star Delta). The Cables used should be Copper up to 10 sq.mm and Aluminum cable above 10 sq.mm. Armoured XLPE Cables to be used. Control Panel internal wiring to be carried out in 2.5 mm2 copper wires FR grade. Wires will be terminated to connector strip (Stud Type Connectors for Power Terminals) by using pin type lugs with Ferules. Supply and exhaust motor to have interlock. 20% additional potential free contact to be provided for BMS integration. Control Panel to be mounted on black powder coated MS stand. Cabling from AHU to Control panel will be in contractor scope irrespective of length of the cable required. Suitable quantity of cabling to be included in the costing.
VE-01- EXHAUST MOTOR:- 2-HP
Supply, Installation and Commissioning of AHU/Duct mounted dew point sensor along with cabling upto control panel. Sensor to be compatible with HVAC series VFD for controlling the actuators of Chilled water. Cabling from AHU to Control panel will be in contractor scope irrespective of length of the cable required.Suitable quantity of cabling to be included in the costing.
Supply, Installation and Commissioning of Duct Mounted Temp & RH Sensor for for controlling Hot water water modulating valve with cabling upto Control panel. Sensor to be compatible with HVAC series VFD for controlling the actuators of Hot water.Cabling from AHU to Control panel will be in contractor scope irrespective of length of the cable required.Suitable quantity of cabling to be included in the costing.
Supply installation testing and commissioning of microprocessor based PID controller to control Chilled water 2 way PIBC valve by taking feedback from temperature sensor and will control the VFD by taking feedback from Differential pressure transmitter. Control cabling required will be the part of control panel wiring. PID controller to match with the existing PID controller installed, All the PID controller to be of same make. Additional 4 I/o to provided in the PID controller, 20% additional potential free contact to be provided for BMS integration
PID FOR AHU-01
PID FOR AHU-02
Supply and installation of following sizes of pre-fabricated Hot dipped GI perforated type cable tray along with coupler plates, 90° bends, Tees, necessary nut-bolts / washers and other hardware etc. including providing / fixing of necessary supports.
50mm (W) x 25mm (H) x 2mm (THK) cable trays
100mm (W) x 25mm (H) x 2mm (THK) cable trays
Supply and Installation of AHU condensate Drain Piping in Heavy Duty UPVC piping along with insulation of suitable thickness to avoide condensation and Clamps with rubber Pad packing on top and bottom side of pipe along with fitting accessories like bends, elbows, T's etc. duly supported at proper intervals. PVC pipe to be insulated with 32mm thick nitril rubber.
Supply, Installation, Testing, Commissioning of Eurovent/AHRI certified Double Skin Heat recovery wheel section with Al Thermal break profile and integral internal coving, double skin panels minimum 43±2 mm thick fabricated out pre-plasticized 22 swg GSS on outer side and plain 22 swg Galvanized sheet on inner side with Polyurethane foam insulation density not less than 43 kg/m3 sandwiched between inner and outer sheet for Process area.The Heat recovery wheel section shall comprise of Fresh Air Module with G-4 filter and Damper, Mixing Chamber for G-4 filter section with filters. Plate type Heat exchanger (Min. 70% sensible heat recovery).Heat recovery wheel section, belt drive packages with TEFC motor suitable for operation on 415 +/- 10% volts, 50 Hz, 3 phase, A.C. power supplyAll Dampers to be of Extruded Aluminum Low Leakage Aerofoil Volume Control Dampers with extanded shaft suitable for Manual & Motorised operation with % opening marking, locking and sealing arrangement. Control panel for Heat recovery wheel pump and other accessories to be with the unit, control wiring and necessary stand and support to be considered in costing.
FRESH AIR AHU-01--1953 CFM & EXHAUST AIR CFM--1788 (2000 CFM unit)
FRESH AIR AHU-02--6616 CFM & EXHAUST AIR CFM--6088 (7000 CFM unit)
Supply, Instalation, Testing and Commissioning of Chilled water FCU Unit shall consist of CHW coil, fan, fan motor, coarse filters housed in a sheet metal casing complete with vibration isolators. The unit will have proper mounting arrangment. The Unit should consist of inbuilt controller to control the FCU unit with Temperature Sensor and its cabling. The FCU unit should include Manifold, Manifold to have Extended spindle Ball Valve / Butterfly valve- 5 Nos flanged End, 2-Way Pressure Independent balancing & Control valve (PIBCV) with Actuator and all Accessories - 1 Nos Flanged end , Y strainer with SS/Bronze mesh - 1 Nos Flanged End, Auto Air vent with 15mm ball valve - 1 Set, Drain Valve - 1 Nos 25 NB, 4'' Dial Pressure Gauge 0-7kg/cm2 - 2 Nos With syphon and ball valve, Temperature Gauge with thermowell (range 0-100C) - 2 nos, Pipe Insulaton:32 mm thk Puf Insulation f Density Not less than 40Kg/m3.t The insulation shall be available in self-seal (pre-slit and pre-glued) pre-formed tube type for pipe diameter upto 4 inches. For pipe diameters above 4 inches factory-cut sheet insulation to match the pipe OD should be used. The Adhesive to be used as recommended by Manufacturer. The Application will be executed strictly as Specified by manufacturer. The Insulated Pipe shall be with 26 gauge aluminium Cladding.U-Loop along with drain valve & Funnel to be supplied as part of manifold. Manifold to be marked with arrows reflecting the direction of water flow for both supply and return along with system no.The entire manifold assembly to be factory fabricated upto isolation valves. Temperature sensor and control panel required for FCU to be provided with the unit along with the stand for Electrical Paneal and necessary cabling and accessories required. (Cost of FCU unit shall include Electrical Panel, temperature sensor Chilled water manifold including valves, Chilled water tapping and cabling irrespective of piping and cabling length required.)
1.00 TR FCU--- (STAFF ROOM)
1.50 TR FCU--- (UPS & BATTERY ROOM GF )
Validation of HVAC System as per WHO TRS/ISO 14644 Guidelines Air Balancing, ACPH/Return CFM/Supply CFM/Fresh air CFM/Bleed CFM, HEPA integrity test, Particle count, Recovery test, Airflow pattern recording, Temp and RH Monitoring for Continuous 3 days with data loggers and any other test as per client requirement or as per guidelines. Vendor to follow the Clients protocol to carry out the validation of the Systems.Blow down of AHU will be part of validation scope. Lot should be for Total Area of Ground and first floor, in case of phase wise construction the Lot should be considered complete after final phase and that should be Ground and first floor completion.
1 set of inbuilt terminal heater and controller. (item No 13) to be provided in spare, 2set of Belt to be provided where belt drive motor /main equipment has been provided with belt driven motor, 2 Nos of Spare PID controller to be provided of same make. All the filters including HEPA 1 set spare filters to be provided based on the AHU/Main equipment riser FCU etc.
Civil
Wall Panels – Progressive type SITC of Prefabricated factory made one-piece modular sandwich progressive panels, laminated with 0.8 mm cold rolled powder coated GI sheets on both sides with infill as PUF as core insulation material with density of minimum 40 kg/m³ for PUF and overall thickness of 80 mm. Minimum width of standard panel should be not less than or equal to 1185 mm, cost should include necessary panel to panel joining arrangement, necessary channels and flashings for fixing panels on the floor. GI profile along the periphery for reinforcement. U Floor Track suitable to accomodate epoxy floor flush with wall panel. The panels will be supplied in colour or as per client’s requirement, shade as per RAL codes and with peel off film. The peel off film will be removed after installation and all joints finished with silicon sealant application using masking tape. The modules will be smooth monolithic surfaces as well as being easy to clean and attractive. Glazing, doors, return air riser systems, process utility piping and electrical equipment shall be easily integrated in modules. Note:- There should not be any horizontal joint in wall panels of rooms irrespective of variable room height
SITC of Prefabricated factory made one-piece modular sandwich progressive panels, laminated with 0.8 mm cold rolled powder coated GI sheets on both sides with infill as PUF as core insulation material with density of minimum 40 kg/m³ for PUF and overall thickness of 35 mm. Minimum width of standard panel should be not less than or equal to 1185 mm, cost should include necessary panel to panel joining arrangement, necessary channels and flashings for fixing panels on the floor. GI profile along the periphery for reinforcement. U Floor Track suitable to accomodate epoxy floor flush with wall panel. The panels will be supplied in colour or as per client’s requirement, shade as per RAL codes and with peel off film. The peel off film will be removed after installation and all joints finished with silicon sealant application using masking tape. The modules will be smooth monolithic surfaces as well as being easy to clean and attractive. Glazing, doors, return air riser systems, process utility piping and electrical equipment shall be easily integrated in modules. Note:- There should not be any horizontal joint in wall panels of rooms irrespective of variable room height
Ceiling Panel-Walkable Type SITC of Non Progressive Prefabricated factory-made sandwich Ceiling panels laminated with 0.8 mm thick cold rolled powder coated GI sheets on both sides and with necessary flashings and suspension members for erecting the panels at desired levels. PUF insulation as core insulation material with density of minimum 40 kg/m³ for PUF and overall thickness of 50 mm approx., complete with panel to panel joining arrangement, necessary channels and flashings for fixing panels on the wall panels. GI Profile along the preiphery for panel reinforcement. Minimum width of standard panel should be not less than 980 mm. The panels will be supplied in color or as per client’s requirement shade as per RAL codes and with peel off film, the peel off film will be removed after installation and all joints finished with silicon sealant application using masking tape. Cost should include necessary suspension for ceiling, hanging arrangements, bolts, rods etc. Necessary cut-out for HVAC, light & other utilities will be covered with capping / flashing. (Load carrying capacity-250 kg/m2) All supports will be clamp type to suspension grid.
Coving
SITC of of 65 x 65 mm Aluminium Coving with polyester powder coated finish and air tight with sealant at wall to wall and wall to ceiling location. Colour of coving should match the colour of wall and ceiling panel. Note : In case of SS 304 panels coving wall to wall and wall to ceiling coving should be of SS 304.
Wall to Wall & Wall to ceiling
External vertical corner - 90°
3D corners
2D corners
Clean Room/civil Doors-Non flameproof
SITC of Clean Room/civil NON-FLAMEPROOF doors with 46mm thick honeycomb as infill with 0.8 mm thick PCGI Panels. Door frame 1.2 mm thick PCGI. Double glazed 6 mm thick toughened clear view glass (450mm X 600mm ) wherever required with 25 mm black border and both side adhesive tape and silicon sealant, door closer TS 68 Dorma make, drop seal, SS kick plate of 300 mm height and 0.8 mm thick, SS push plate on push side (Size: 125 x 325 (H x 1.2mm thick)), SS 'D' type handles on pull side with ϕ 19 mm x 254mm, single / double side key operated locking arrangement with 3 keys of Doyen Make, SS Ball Bearing Hinges, Silicon Gasket. Door colour: Client to confirm. Note: - 1. Consider Doors in Modular panel with service shaft on one side for Door interlock switch / access control 2. Drop seal should be easily detachable without dismantling the door to suffice maintenance / cleaning requirement. 3. Door dimensions mentioned are indicating clear opening.
Clean Room Doors
Single Door
800 x 2400 mm Single Door
900 x 2400 mm Single Door
1050 x 2400 mm Single Door
Door Accessories
Automatic concealed door bottom Drop Seal (For Flush Floor)
Door Closer (Dorma TS-68) std arm.EN 7
One side S.S. D type handle (200 mm) & other side push plate
Door Lock (Dorset Make)
SS kick 0.8 mm thk plate 300mm Height
Civil Doors
Single Door
650 x 2400 mm Single Door
900 x 2400 mm Single Door
800 x 2400 mm Single Door
1050 x 2400 mm Single Door
Double Door
1200 x 2400 mm Double Door.
Door Accessories
Automatic concealed door bottom Drop Seal (For Flush Floor)
Door Closer (Dorma TS-68) std arm.EN 7
One side S.S. D type handle (200 mm) & other side push plate
Door Lock (Dorset Make)
SS kick 0.8 mm thk plate 300mm Height
Vision Panel:
SITC of View panels should be factory assembled, flush to the wall on both side with double toughened factory made glass. Double Glazed Glass Panel with flush design with 6 mm thick toughened clear glass fixed in panel with 3M or equivalent make both side Adhesive Tape (black) over Aluminium polyester powder coated frame width to match wall thickness with silica gel desiccant arrangement and made air tight with Silicon sealant and all necessary arrangement. Sizes of the View panel for partition wall, the view panel size will be as per BOQ. Glazing will hold in place by extruded aluminium frame and silicon gasket and Food grade. Extruded aluminium frame thickness will vary as per single and double wall panel. View panel will be installed from the finished floor level as per the sill level mention in the Modular panel wall panel layouts / BOQ. (View panel/windows feature concealed anti-moisture agents). View panels should be furnished with the system to avoid condensation between two glasses. Note : View Panel width to match the standard panel width.
Double glazed View Panel in 80mm thk panel
1500x2100 mm (Emergency Crash Panel)
Inbuilt Return Air Riser
SITC of Modular Panels with Inbuilt risers will not be measured separately. They are measured in wall partition quantity. In wall partition inbuilt riser to be created. The return air riser will be fabricated from 20 G powder coated GI sheets capping on either side. The riser shall be provided with four side bevelled SS 304 Perforated Grill. Perforated sheet to be fixed on the wall panel by the magnetic locks (4-6 Nos). The magnetic locks are fixed to the riser frame with SS 304 screws. The perforated sheet will be supported on the wall panels itself. The bottom edge of the suction grill of return air riser will be 100 mm above the finished floor level. Necessary stiffeners / supports shall be provided within to avoid buckling of the riser panels. Riser duct should extend 200 mm above ceiling with 32 mm flange suitable for top / side connection.
SS 304 perforated sheet of 1.20 mm thick with 65% perforation area, magnetic latch arrangement,ceiling operated damper and 200 mm extended riser height above top side of the ceiling for duct connection with mating flange.
Supply and fixing for volume control damper inside the riser from room side 610x80
PVC Conduits & Boxes for fixing following
Cut-outs
Cutout Profiles for Terminal Box 300x300mm
Cutout Profiles for Terminal Box 450x450mm
Cutout Profiles for Diffuser 300x300mm
Cutout Profiles for Diffuser 450x450mm
Cutout Profiles for Grill 300x300mm
Cutout Profiles for Grill 150x150mm
Cutout Profiles for Light Fixtures 300x300mm
Cutout Profiles for Light Fixtures 600x600mm
Cutout Profiles for Riser Grill size 500x450mm
Fire Sprinkler
Sprinkler/Hydrant System (Internal)
Providing, laying, jointing, testing and commissioning of G.I. `C' Class pipes (IS:1239 (Part-I)-1979) including cutting,threading welding etc providing all malleable galvanized iron fittings conforming to IS 1879, viz. Flanges, bends, tees, elbows,reducers, unions, supporting with G. I. clamps, hangers, M.S. brackets etc. including cutting holes and chases in brick or RCC wall / slabs and making good the same to the Approval of Architect / consultant,complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade. ( INTERNAL FIRE FIGHTING SYTEM)
25 mm dia.
32 mm dia.
40 mm dia.
50 mm dia.
Providing , fixing testing and commissioning of pendant type sprinkler heads 68 deg. Temp.(K-5.6-Quick response type)
Providing & fixing testing and commissioning of UL Rated SS Flexible pipe-1.6MT long
Gun metal chrome finished Ball valves (PN 16) with fittings of screwedend type.
32 mm dia.
Butterfly Valves (PN 16) with CI Body, Black Nitrile Body Liner and Nylon Coated SG Iron Disc with material and labour including hydraulic testing etc. complete as per drawing, specification & to the level of satisfaction of Site- Incharge.
80 mm dia.
Flow switch on sprinkler distribution header on each floor with 2 SPDT contacts suitably rated, capable of the high pressure system and connected to fire alarm panel through cable. ( suitable connecivity to FA system)
80 mm dia.
STATUTORY APPROVAL -OR THIRD PARTY CONSULTANT
Sealing of fire shafts at all floor levels by using M.S. angle iron frame around the shaft, M.S. chequered plate and PCC of 1:2:4 (100mm thick) on the plate for whole shaft area.
Liasoning work with Statutory Authorities (CFO/etc.) for obtaining approval by preparing plans for submittal etc.incidental expenses connected with approval from Statutory Authorities (CFO) (All official fees/ deposits will be paid by Client)
Fire order signages for fire escape routs (LED type) with required all details as per statutory requirements
Note- 1) Contactor shall submit the hydraullic calculations /Shop drawings/revision required as per sites etc 2) Piping test with with 10 kg/cm2 pressure ( OR 2.5 times of design pressure) for 24 hours.3)Design validation by performing the functional tests with simulated fire condition in the space to be decided by the Client. The contractor shall supply all materials, labor and personnel , required for the functional test.
Description of Work / Item(s)
Amount
PART B
Providing Comprehensive Maintanance Contract of complete HVAC system as installed as per PART A (AHUs, FCU,s, Exhaust, VFDs, Main Electrical Control of HVAC System, Electrical Control panel of AHUs etc and as per detail scope of work as mentioned in tender document terms and conditions. for a period 5 years to commence on exhaustion of DLP period(DLP period of 12 months After completion of Project )
CMC of 1st year after warrantee
CMC of 2nd year after warrantee
CMC of 3rd year after warrantee
CMC of 4th year after warrantee
CMC of 5th year after warrantee
BRITE INDUSTRIES (BID ID -3048159)
VAV Airconditioning (BID ID -3066666)
BRITE INDUSTRIES (BID ID -3048159)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_853864.xls
BOQ • 0.48 MB
TD.pdf
Tender Documents • 2.12 MB
AnnexureForm.xls
Additional Documents • 0.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .