| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹33.4 LAccepted-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹36.4 L+₹2.1 L (6.06%)Rejected-AOC B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹39.4 L+₹5.1 L (15.0%)Rejected-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹40.7 L+₹6.4 L (18.7%)Rejected-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L-4 | Rejected-AOC L-4 | |
| 5 | L-5₹43.8 L+₹9.5 L (27.7%)Rejected-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L-5 | Rejected-AOC L-5 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
9 Apr 2022, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER I RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/MAINT OF DG SET, AMF PANEL OF WATER SUPPLY INSTALLATION, VRF 22TR AC PLANT AND 5 TR PACKAGE TYPE AC PLANT AND SUMMER APPLIANCES AT SSPL UNDER GE (I) RND DELHI
2022_MES_506175_1
GE/RND-107/DLI/2021-2022
Open Tender
Civil Works
Item Rate
270 days
Delhi
Class-D, cat c(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹90,000
Yes
28 Apr 2022
5 Feb 2022
11 Apr 2022
5 Feb 2022
9 Apr 2022
28 Mar 2022
Amount
M&L for B check general servicing by authorised rep of manufacturer of DG set of capacity 62.5 KVA, replacement of oil filter, fuel filter, air filter, by pass filter cleaning of radiator with chemical after draining out engine/ lubrication oil, coolant flushing and cleaning of oil chamber after opening of tappet cover/ top cover tappet clearence setting injector timing adjustment re-affixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/ chamber gasket at the servicing and other work comes under B Check service as mentioned in B Check by the manufacturer complete all as specified and directed. Note-Engine oil & Coolant will be paid separately under respective item.
All as per Ser item No 1 but of capacity 75 KVA
All as per Ser item No 1 but of capacity 200 KVA
All as per Ser item No 1 but of capacity 250 KVA
All as per Ser item No 1 but of capacity 320 KVA
All as per Ser item No 1 but of capacity 625 KVA
M&L in repair for self starter 12 V including rewinding of armature with super enamaled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon brush including services suitable for DG set 62.5 to 100 KVA complete all as specified and directed.
M&L in repair for self starter 24 V including rewinding of armature with super enamaled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon brush including services suitable for DG set upto 625 KVA complete all as specified and directed.
S&F in replacement automatic battery charger with auto cut OFF suitable for charging of 2X12V 180AH batteries complete with all required necessary wiring complete all as specified and directed.
M&L in replacement wiring complete to AMF panel for any capacity of DG set including interlock system of AMF panel with existing size of copper wiring including proper connection and testing complete all as specified and directed.
S&F in replacement self starter 24 volts suitable for upto 625 KVA DG sets complete all as specified and directed.
S&F in replacement battery brass terminals heavy duty suitable upto 12V 180 AH battery with minimum 2 RM Battery Lead of copper Cable single core complete all as specified and directed.
S&F in replacement relay 24 V 8 pin type as per matching to existing and properly connection and testing after completion complete all as specified and directed.
S&F in replacement engine starting relay suitable for DG set of capacity 62.5 KVA to 100 KVA as per matching to existing complete all as specified and directed.
S&F in replacement engine starting relay suitable for DG set of capacity 200 to 625 KVA as per matching to existing complete all as specified and directed.
S&F in replacement Electronic timer suitable for AMF panel of DG set as per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed.
S&F in replcement Voltmeter analog type for voltage range of (0-24V) as per matching to existing with all accessories and wiring complete all as specified and directed.
S&F in replcement Voltmeter analog type for voltage range of (0-500V) with all accessories and wiring complete all as specified and directed.
S&F in replcement Ammeter analog type for current range of (0-24Amps) as per matching to existing with all accessories and wiring complete all as specified and directed.
S&F in replcement Ammeter analog type for current range of (0-1000Amps) as per matching to existing with all accessories and wiring complete all as specified and directed.
S&F in replecement power contactor ML 6 suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
S&F in replecement power contactor ML 4 suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
S&F in replecement power contactor ML 3 suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
S&F in replecement power contactor ML 2 suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
S&F in replacement under voltage relay suitable for DG set upto 320 KVA complete all as specified and directed.
S&F in replacement complete wiring with single core multistranded copper cable with flexible conduit for DG set of various capacities complete all as specified and directed.
Supply, fixing and testing Electronic Governor Controller for 200 to 625 KVA DG Set including taking down old Governor Controller complete all as specified and directed.
S&F new actuator for upto 625 KVA DG Set complete including taking down old actuator from its position complete all as specified and directed.
Opening the DG set of 200 to 625 KVA , repair to any leakage in radiator, greasing of all movable parts & equipments and replacing all flexible/steel wire mesh type hose pipes including fuel pipe line , belts & Bearings including re-assembling the complete Parts and Testing complete all as specified and directed. Note:- Spare parts required for replacement shall be measured and paid separately under respective items.
S&F Piston ring and liner for 200 to 320 KVA DG Set as per existing complete all as specified and directed.
Supply only Head valve, Head Guide, Head sheet & Head seal for 200 to 320 KVA DG Set as per existing complete all as specified and directed.
Supply only Injector sleeves & Head gasket for 200 to 320 KVA DG Set as per existing make complete all as specified and directed.
Supply only Packing Kit for 200 to 320 KVA DG Set as per existing complete all as specified and directed.
M&L in repair for Head and fuel injector assembly complete for 200 to 320 KVA complete all as specified and directed.
M&L in repair for Turbo assembly complete for 200 to 320 KVA complete all as specified and directed.
Opening the DG set of 625 KVA , repair to any leakage in radiator, greasing of all movable parts & equipments and replacing all flexible/steel wire mesh type hose pipes including fuel pipe line , belts & Bearings including re-assembling the complete Parts and Testing complete all as specified and directed. Note:- Spare parts required for replacement shall be measured and paid separately under respective items.
S&F Piston ring and liner for 625 KVA DG Set as per existing complete all as specified and directed.
Supply only Head valve, Head Guide, Head sheet & Head seal for 625 KVA DG Set as per existing complete all as specified and directed.
Supply only Injector sleeves & Head gasket for 625 KVA DG Set as per existing complete all as specified and directed.
Supply only Packing Kit for 625 KVA DG Set as per existing complete all as specified and directed.
M&L in repair for Head and fuel injector assembly complete for 625 KVA complete all as specified and directed
M&L in repair for Turbo assembly complete for 625 KVA complete all as specified and directed.
Taking down the old unserviceable fan belt and Supply and Fix Fan belt of existing size for DG Set of capacity 62.5 to 200 KVA complete all as specified and directed.
Taking down the old unserviceable fan belt and Supply and Fix Fan belt of existing size for DG Set of capacity 250 to 320 KVA complete all as specified and directed.
Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifold for DG sets 62.5 KVA includung removing of existing asbestos rope or any other type of insulation complete all as specified and directed.
Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifold for DG sets 200 KVA includung removing of existing asbestos rope or any other type of insulation complete all as specified and directed.
Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifold for DG sets 250 to 625 KVA includung removing of existing asbestos rope or any other type of insulation complete all as specified and directed.
S&F in replacement fly wheel ring of DG Set of capacity upto 62.5 KVA complete all as specified and directed.
S&F in replacement fly wheel ring of DG Set of capacity 250 to 320 KVA complete all as specified and directed.
Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 62.5 to 200 KVA complete all as specified and directed.
Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 250KVA complete all as specified and directed.
Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 320 to 625 KVA complete all as specified and directed.
S&F in replacement Changeover switch on load front operated 320 Amps 4 Pole 415 volt including properly connecting incoming and outgoing cable and testing after complete all as specified and directed.
M&L in repair for radiator of 62.5 to 200 KVA DG set ,arresting leakage if any by welding/brazing and refixing the same for (Necessary coolant and distrilled water required will be measured and paid seperately) complete all as specified and directed.
M&L in repair for radiator of 250 to 625 KVA DG set,arresting leakage if any by welding/brazing and refixing the same for (Necessary coolant and distrilled water required will be measured and paid seperately) complete all as specified and directed.
M&L in repair for removing and replacing the old unserviceable lead acid battery of size 12 Volt, 180 AH of reputed make including charging complete all as specified and directed.
Removing old U/S insulating material asbestos rope and fixing of new of existing size and shape complete all as specified and directed.
M&L for spray painting of diesel generating set of capacity 62.5 to 200 KVA with accousitic enclosure/ open type one coat of synthetic enamel paint body colour shall be apple green,black for foundation base frame, red for all guards for complete all as specified and directed.
M&L for spray painting of diesel generating set of capacity 250 KVA with accoustic enclosure one coat of synthetic enamel paint, body colour shall be apple green,black for foundation base frame, red for all guards for complete all as specified and directed.
M&L in repair for spray painting of diesel generating set of capacity 320/625 KVA with accoustic enclosure one coat of synthetic enamel paint, body colour shall be apple green,black for foundation base frame, red for all guards for complete all as specified and directed.
M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggregate for foundation of pole complete all as specified and directed.
S&F in replacement 3 Pole MCCB, 630 Amp, 36 KA with microprocessor release and Adjustable overload setting , 50 Hz, 415 V complete all as specified and directed.
S&F in repair MCCB 125Amps 3 Pole breaking capacity 35KA complete all as specified and as directed.
All as per ser item No. 52.00 above but 100 Amp 3 Pole 25 KA.
All as per item no 52 but of capacity 250A 3 Pole 25 KA.
All as per item no 52 but of capacity 200A, 3 Pole 25 KA
S&F in repair MCCB 630 Amps 4 Pole breaking capacity 50KA complete all as specified and directed.
S&F in repair MCCB 400 Amps 4 Pole breaking capacity 36KA complete all as specified and directed.
S&F in repair MCCB 250 Amps 4 Pole breaking capacity 36KA complete all as specified and directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick reinforced with 8 mm dia TMT bar 75 mm center to center with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x4 mm galvanised iron strip complete all as specified and directed.
Supply and laying GI pipe light grade in replecement of old unserviceable 50mm dia including fittings laid in trenches or under road crossing for protection of UG cable complete all as specified and directed.
Supply and laying GI pipe light grade in replecement of old unserviceable 80mm dia including fittings laid in trenches or under road crossing for protection of UG cable complete all as specified and directed.
M&L for boring of holes under road, pavement, hard standing by trenchless techonology using ultra sound technique/mannually/mechanically and necessary machine including supply and laying of 100mm dia GI pipe light grade including making necessary excavation upto 1.5 mtr deep on both side of road for making holes and inserting 100mm dia GI Pipe complete all as specified and directed.
M&L in repair for alternator of DG Set of capacity 200 KVA complete including rewinding & replacement of connected items such as bearing, sleeves Nut bolts, coupling etc complete all as specified and directed.
M&L in repair for alternator of DG Set of capacity 320 KVA complete including rewinding & replacement of connected items such as bearing, sleeves Nut bolts, coupling etc complete all as specified and directed
S&F in repair earth pit chamber alongwith cover of Polymer, FRP Pit Cover of heavy high grade polypropelene for high stress and starin level of size 225x300x195 mm complete all as specified and directed.
S&F ACP retro sign board of size 1.5x1.1 Meter using retro reflective high intensity prismatic reflective sheeting. The back ground of board is Blue Colour with white border and writing letter, numbers white colour mentioning the DG Set sub-station Details and Single line Schematic diagram of substation. Retro sign board shall be pasted on 3 mm thick ACP sheet. The board shall be fixed on Wall including fixing of fastners, nuts, bolts, washer etc complete all as specified and directed.
S&F MS Galvanised Chain link fencing,any size or type complete including taking down old underviceable complete all as specified and directed.
M&L MS chequred plate of suitable size for cable duct cover 6mm thick and earth pit cover complete all as specified and directed.
M&L for charging of Refrigerant R-22 complete including testing after complete all as specified and directed.
M&L for charging of Refrigerant R-410A including testing complete all as specified and directed.
M&L for repair to leakage including brazing, Nitrogen Testing by holding the pressure for minimum 24 hours and recommissioning of 22 TR VRF Unit complete all as specified and directed.
All as per ser item No. 73.00 above but 5 TR.
S&F in repair refrigerant copper pipe 15mm dia, 0.64 mm wall thickness complete all as specified and directed.
S&F in repair refrigerant copper pipe 12 mm dia, 0.64 mm wall thickness complete all as specified and directed.
S&F in repair refrigerant copper pipe 5/8" (15.88mm) dia thick including foam insulation for copper tube wall complete all as specified and directed.
S&F in repair refrigerant copper pipe 3/8" (9.52mm) dia thick including foam insulation for copper tube wall complete all as specified and directed.
S&F in repair Control PCB suitable for VRF AC 22 TR outdoor complete all as specified and directed.
S&F in repair inverter PCB suitable for VRF AC 22 TR outdoor complete all as specified and directed.
S&F in repair power transistor suitable for VRF AC 22 TR complete all as specified and directed.
S&F in repair Compressor hermatically Sealed suitable for VRF AC 22 TR complete all as specified and directed.
S&F in repair diode module suitable for 22 TR AC Plant complete all as specified and directed.
S&F in repair of resistor suitable for VRF AC 22 TR outdoor complete all as specified and directed.
S&F in repair noise filter PCB suitable for VRF AC 22 TR outdoor complete all as specified and directed.
S&F in repair Indoor unit PCB suitable for 22 TR AC Plant complete all as specified and directed.
S&F in repair IDU remote sensor eye receiver suitable for 22 TR AC Plant complete all as specified and directed.
S&F in repair ODU fan motor suitable for 22 TR AC Plant complete all as specified and directed.
S&F in repair ODU sensor set suitable for 22 TR AC Plant complete all as specified and directed.
Quarterly inspection of all 22 TR VRF of make MISHI BHUSHI unit from Authorised dealer complete all as specified and directed. Note:- The inspection shall be carried out by the service Engineer of OEM/authorised dealers having the experience with company not less than 5 years. Inspection report shall also be submitted to the GE /Engineer-in-Charge duly signed by authorised representative, contractor etc. The rates for transportation, lodging boarding etc if any required shall deemed to be inclused in quoted unit rates.
S&F in repair outdoor PCB suitable for Package type AC plant 5 TR complete all as specified and directed.
S&F in repair indoor PCB suitable for Package type AC plant 5 TR complete all as specified and directed.
S&F in repair indoor cooling coil suitable for Package type AC plant 5 TR complete all as specified and directed.
S&F in repair compressor hermatically Sealed suitable for Package type AC plant 5 TR complete all as specified and directed.
M&L for Soft Chemical servicing of 22 TR VRF AC Plant indoor Units including minor parts complete all as specified and directed.
M&L for Soft Chemical servicing of 22 TR VRF AC Plant Outdoor Units including minor parts complete all as specified and directed.
M&L for Soft Chemical servicing of 05 TR package type AC Plant indoor Units including minor parts complete all as specified and directed.
M&L for Soft Chemical servicing of 05 TR package type AC Plant Outdoor Units including minor parts complete all as specified and directed.
M & L for Servicing of the window AC 1.5/2 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and directed. Note :- (i) Any unserviceable spare parts & gas charging required to be replaced shall be measured & paid separately under respective item. (ii) The cost of dismantling, taking out window AC 1.5/2.0 ton from window and shifting to location where directed for proper washing and servicing and refixing the same shall deemed to be included in unit rate quoted.
All as per ser item No. 99.00 above but for split type AC/Inverter type/casette type AC 1.5/2.0/4.1 Ton.
All as per ser item No. 99.00 above but for VRF inverter split type 3 phase AC of capacity 8 TR.
M&L in replacement Fan Motor of AC (Window/ Split Type) 1.5 TR Capacity of approved Make and required Size to suit existing AC including taking out the unservice-able Fan Motor from the AC,complete all as specified and directed.
All as per Item No. 102.00 above but AC (Window/Split Type). 2.0 TR Capacity
M&L Rewinding Fan Motor of AC 1.5/2.00 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate Gauge and Quantity including taking out burnt Winding, complete all as specified and directed.
M&L in replacement Air circular Blower Fan Motor of AC (Split Type), 1.5 TR/2.0/3.00TR Capacity including taking out unser-viceable Air circular Blower Fan Motor complete all as specified and directed.
M&L in replacement Air Filter suitable of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filter from AC complete all as specified and directed.
M&L in replacement Air Filter suitable for AC Split type 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filter complete all as specified and directed.
M&L in replacement Capacitor Running 36 mfd – 45 mfd suitable for new/star rated for AC (Window/Split Type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Capacitor from AC complete all as specified and directed.
M&L in replacement Capacitor Starting 80 mfd – 120 mfd suitable for old ones AC (Window/Split Type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Capacitor from AC complete all as specified and directed.
M&L in replacement Fan Motor Blades AC (Window/Split type) 1.5/2.0 TR capacity including taking out unserviceable Blades of Fan Motor from AC complete all as specified and directed.
M&L in replacement Fan Motor Capacitor 4 mfd of suitable for new/star rated AC (Window/Split Type) 1.5/2.0TR capacity including taking out unserviceable Fan motor capacitor from AC complete all as specified and directed.
M&L Fan Motor in replacement Capacitor 6 mfd suitable for old ones AC (Window/Split Type) 1.5/2.0TR capacity including taking out unserviceable Fan motor capacitor from AC complete all as specified and directed.
M&L in replacement Front Plastic Grill of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC all as per existing and complete all as specified and directed.
M&L in replacement Front Plastic Grill for inner unit of AC (Split type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC all as per existing complete all as specified and directed.
M&L in replacement Runner for air blower motor of AC (split type) AC 1.5/2.00TR capacity as per site requirement) including Runner of Air Blower Motor from AC all as per existing complete all as specified and directed.
M&L in replacement Single Pole Contactor 25A Capacity, MR 11W type as approved suitable for AC (Split Type) including taking out unserviceable Single Pole Contactor complete all as specified and directed.
M&L in replacement Starting Relay of AC (Window/Split Type) 1.5 TR/2.0/3.00TR Capacity including taking out unser-viceable Starting Relay from AC complete all as specified and directed.
M&L in replacement Strainer with Capillary Tube of AC Window/ Split Type) 1.5 /2.0/3.0 TR Capacity including taking out unserviceable Strainer with Capillary Tube from AC complete all as specified and directed.
M&L in replacement Thermostat Switch of AC (Window/Split Type) 1.5 TR/2.0/3.0 TR Capacity including taking out unserviceable Thermostat Switch from AC complete all as specified and directed.
S&F in replacement cooling coil suitable for window type room AC 1.5/2 TR including taking out unserviceable cooling coil of capacity 1.5/2 TR. complete all as specified and directed.
S&F in replacement Condensing coil suitable for window type AC 1.5/ 2 ton including taking out unserviceable Condensing coil of capacity 1.5/2 ton complete all as specified and directed.
S&F in replacement Condensing coil suitable for split type AC including taking out unserviceable Condensing coil of capacity 2 ton complete all as specified and directed.
S & F in replacement cooling coil suitable for split type AC including taking out unserviceable cooling coil up to capacity 2 ton complete all as specified and directed.
S&F in replacement Indoor unit suitable for 1.5 TR split type AC including taking out unserviceable Indoor unit complete all as specified and directed.
S&F in replacement outdoor unit suitable for 1.5 TR split type AC without compressor including taking out unserviceable outdoor unit complete all as specified and directed.
S&F in replacement Indoor unit suitable for up to 2 TR split type AC including taking out unserviceable Indoor unit complete all as specified and directed.
S&F in replacement outdoor unit suitable for up to 2 TR split type AC without compressor including taking out unserviceable outdoor unit complete all as specified and directed.
S&F in replacement of Hermatically sealed unit compressor for split/ window type AC capacity 1.5 Ton complete all as specified and directed.
All as per ser item No. 130 above but of split/ window type AC capacity 2.0 Ton.
Taking down/up defective AC 1.5 TR Capacity (Window/Split Type), Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt Com-pressor Sealed Unit and providing new Compressor Rotary/ Reciprocating as per site requirment of same Capacity from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R22/R410 including re-connection of Electric Connections, functioning AC in all respect and Testing, complete all as specified and directed.
All as per Item No. 132.00 above, but AC 2.0 TR Capacity (Window/Split Type).
M&L in replacement PCB with remote for window type AC up to 2 Ton capacity including taking out unserviceable PCB complete all as specified and directed .
M&L in replacement PCB with remote for Split type AC 2/3(1.5x2) Ton capacity including taking out unserviceable PCB complete all as specified and directed .
M&L in replacement PCB & motherboard with remote complete set for Inverter Split type AC up to 2 Ton capacity including taking out unserviceable PCB complete all as specified and directed .
M&L in replacement Remote of AC ( Window/Split Type) 1.5/2.0 TR capacity (As per sample or as per site requirement) complete all as specified and directed.
S&F in replacement wiring kit suitable for 1.5 to 2.0 ton capacity AC complete including taking out unserviceable wiring kit complete all as specified and directed.
S&F in replacement gas charging pin valve complete including taking out unserviceable pin valve complete all as specified and directed.
Taking out window type AC complete unit from any height/ any floor up to four storey building and shifting to another location in the same or other building in the complex including refixing of the unit complete all as specified and directed.
Taking out split type AC complete indoor and outdoor unit from any height/ any floor up to four storey building by including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiion in the same or other building in the complex including refixing of the unit complete all as specified and directed.
Supply and charging the gas refrigerant R22 (including refrigerant) of window type AC upto 2 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed.
All as per ser item No. 142 above, but R- 410/32 for split type AC up to 2 TR capacity.
All as per item No 142 above, but cassatte type AC 4 TR capacity.
All as per item No 142 above, but VRF unit 8 TR capacity.
S&F in replacement of casing of window type AC including company fitted condensing & cooling coil complete including PCB except compressor complete all as specified and directed.
M&L for replacement of split valve ¼” for split AC up to 2.00 ton capacity complete all as specified and directed.
All as per ser item No. 147 above, but 1/2".
S&F in replacement compressor shut off valve 3/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
S&F in replacement compressor shut off valve 5/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
S&F in replacement of electrolyte grade copper tubing of size 1/4" suitable for any type of split type AC including synthetic rubber foam complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building complete all as specified and directed.
All as per ser item No. 151 above, but size 1/2".
All as per ser item No. 151 above, but size 3/8".
All as per ser item No. 151 above, but size 5/8".
S&F in replacement PVC conduit 20mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 5 (five) storey complete all as specified and directed.
S&F in replacement PVC conduit 25mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from Acs of Bldgs upto 5 (five) storey complete all as specified and directed.
S&F in replacement Hermatically Sealed compressor for 40/80 Ltrs capacity water cooler including bracing the suction and discharge lines complete all as specified and directed.
S&F in replacement Hermatically Sealed compressor for 60/120 Ltrs capacity water cooler including bracing the suction and discharge lines complete all as specified and directed.
S&F in replacement metal plug top 3 pole and earth, 20 Amps, 240 volts suitalbe for sheet metal enslousers complete all as specified and directed.
S&F in repalcement metal enclosures with clad socket & plug top 3 pole and earth, including of MCB SP 25 Amps 240 volts complete all as specified and directed.
S&F in replacement of PVC insulated flexible copper conductor 3 core 1100 volts grade of size 2.50 Sqmm complete all as specified and directed.
S&F in replacement of PVC insulated flexible copper conductor cable 1100 volts grade, 3 core of size 1.5 Sqmm complete all as specified and directed.
M&L in replacement for submain wiring including PVC casing capping 2 run 4.00 Sqmm cable PVC insulated copper conductor multi - stranded as per FRLS cable drawn through conduit pvc 20mm dia mediam duty with all accessories including 4.0 Sqmm single stranded copper conductor cable PVC insulated unsheathed for earth continuity connected to common earth dolly and complete all as specified and directed.
S&F in replacement AC stand suitable for out door AC unit up to capacity of 2 ton with necessary 40x40x6mm angle iron including fixing arrangements like welding, fabrication and nuts & bolts etc upto six stories building complete all as specified and directed.
S&F in replacement reverse valve system made of copper for heating option suitable for 1.5/2.0 ton split / window type AC including appropriate Gas Charging complete all as specified and directed.
M&L for servicing of water cooler of any capacity including cleaning of water cooler from inside and outside with potassium permanganates, servicing of colling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed.
Supply and charging the gas in the water cooler of any make and capacity up to 150 ltr capacity including testing and detecting leakage if any with nitrogen gas and vaccum the system after rectification of all leakages complete all as specifie and directed.
S&F in replacement thermostat switch suitalbe for water cooler of any make & size complete all as specified and directed.
S&F in replacement starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed.
S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed.
M&L for preparation of old painted surfaces of water cooler by removing old deteriorated paint, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting complete all as specified and directed.
S&F in replacement fan motor ISI marked suitalbe for water cooler as per existing capacity upto 150 ltrs of any make complete all as specified and directed.
S&F in replacement of condenser fan of any make suitable for water cooler upto 150 ltrs capacity complete all as specified and directed.
S&F in replacement 15 mm dia PVC connection of length upto 600mm with PTMT nuts on both ends complete all as specified and directed.
S&F in replacement condenser coil suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.
S&F in replacement steel/aluminium waste water tray suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.
M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside, greasing of fan kit, motor, water pump and connected accessories complete all as specified and directed.
M&L for painting of desert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint and preparation of surface complete all as specified and directed. Note : The rates are inclusive of taking down cooler from any height, removal to workshop for painiting and refixing in position after painting.
S&F in replacement of desert cooler submersible water pump complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing as per sample complete all as specified and directed.
S&F in replacement desert cooler fan motor,copper wound suitable for upto 450mm sweep SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing complete all as specified and directed.
S&F in repalcement of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as specified and directed.
S&F in replacement plug top 3 pin 5 Amps complete all as specified and directed.
S&F in replacement plug top 3 pin 15 Amps complete all as specified and directed.
S&F in replacement motor capacitor 2.5/3.15/4 mfd complete all as specified and directed.
S&F in replacement front grill made of MS complete with air guide vanes suitable for desert cooler of capacity 4000 Cfm complete all as specified and directed.
S&F in replacement of body without side panels made out of galvanised iron sheets of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide primer & 2 coat of synthetic enameled paint approx size 0.50mx0.50m complete with fixing of all spare complete all as specified and directed.
S&F in replacement of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red-oxide primer & 2 coat of synthetic enameled paint complete with fixing of all spare approx size 0.40mx0.50m complete all as specified and directed.
S&F in replacement of float valve assembly with PTMT ferrule 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfm complete all as specified and directed.
S&F new wood wool pad,(Khus Khas) set of three covered by GI wire mesh suitable for desert cooler including taking out the old unserviceable existing pad complete all as specifed & directed
M&L for replacement of aluminium multi wing Fan blade, best quality as per existing type and size suitable for desert cooler complete all as specifed and directed
Taking down ceiling fan/exhaust/pedestal/table/air circulating fan of any size or make by disconnection eletric connection and removing from site for rewinding/ overhauling/ engrawing of MES No of fans and fixing the same in eixsting position or as directed by engineer-in-charge with eletric connection and testing complete all as specified and directed
M&L for overhauling of ceiling fan/pedestal/exhaust/table/aircirculating fan of any size or make opening the fan motor, overhauling by removing dust from field coils including varnishing of field coils and greasing from motor with superior qauality grease for smooth running inlcuding cleaning and washing the blades and assembling of fan motor and refixing at the same place complete all as specified and directed.
M&L for removing of burnt out winding wire from ceiling fan of any make of size 1200/1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material and varnishing complete all as specified and directed.
All all as per item Ser No 194.00 above but for exhaust fans of size 225 mm sweep to 380 mm sweep
All all as per item Ser No 194.00 above but for exhaust fan of size 450 mm sweep
All all as per item Ser No 194.00 above but for pedestal fan/Air circulator fan of size 400 mm to 600 mm sweep.
All all as per item Ser No 194.00 above but for table fan/wall mounted of 400 mm sweep
M & L for replacement of defective ball bearing for ceilng/table/pedestal/Air-circulators fan of any size complete all as specified and directed.
All as per item Ser No 199 above but for exhaust fan upto 450mm size.
M&L for replacement of rubber seal of suitable size for ceiling fan complete all as specified and directed
M&L for replacement of gun metal bush suitable for any type/model/size of fans complete all as specified and directed.
M&L for replacement of ceiling fan regulator five step 60/120 watt electronic type AC 230/240 Volts suitable for 1200/1400 mm sweep complete with all fixing accessories including necessary electric connection all as specified and directed.
M&L for painting of ceiling fans any make and size at site with one coat of superior quality synthetic enameled paint of approved make & colour by spraying after filling cavities with filler and preparation of surface including marking complete all as specified and directed.
All as per item Ser No 204 above but exhaust fan of size 250/300 mm sweep complete.
All as per item Ser No 204 avove but for exhaust fan of size 450 mm sweep
S&F in replacement voltage stabilizer 4 KVA suitable for window/split type AC of capacity upto 1.5 TR working on AC 240 V,50Hz single phase complete all as specified and directed.
S&F in replacement voltage stabilizer 5 KVA suitable for window/split type AC of capacity upto 2 TR working on AC 240 V,50Hz single phase complete all as specified and directed.
S&F in replacement Pedestal fan 450mm sweep working on AC 240 V,50Hz, single phase complete all as specified and directed.
S&F in replacement exhaust fan PVC body 250mm sweep working on AC 240 V,50Hz, single phase complete all as specified and directed.
Taking down geyser of capacity 25 ltrs after dissconnecting the water and electric connections etc and replace the stainless steel tank with assembly to make the geyser fully functional and refixing the same at its orignal position complete all as specified and directed.
All as per ser item No. 211 above but capacity 50 ltrs.
S&F in replacement of Heating element triangle/round type as existing of capacity 1.5KW of Hot appliances complete all as specified and directed. .
All as per ser item No. 213 above, but capacity 2KW.
S&F in replacement of thermostate as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
S&F in replacement of shut off valve as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
Taking out the diffective PCB & mother board with remote complete set from 'inverter split type AC upto 2 Ton capacity and repair the deffective PCB with mother board and remote and fixed the same in its original position complete all as specified and directed.
S&F in replacement of Thermo insulation glass wool as per existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed.
S&F in replacement of water connection CP for inlet & outlet (Hot & Cold) as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed.
S&F in repair switch piano type 5 A SP one way complete all as specified and directed.
S&F in repair switch piano type 5 A SP two way complete all as specified and directed.
S&F in repair bell push piano type 5 A complete all as specified and directed.
S&F in repair socket outlet 5 pin 5 A flush type complete all as specified and directed.
S&F in repair of Switch socket combination 2 in 1, 3 pin, 5 and 15 amp flush type universal complete all as specified and directed.
S&F in repair of Ceiling fan regulator electronic, step type, 120 watts 2 module complete all as specified and directed.
S&F in repair of bell ding Dong AC 230 vols, single pole complete all as specified and directed.
S&F in repair of thermostat cut off cut in range 0-75 degree centigrade AC 230 V suitable for storage type geyser 25 ltr capacity complete all as specified and directed..
S&F in repair of thermostat cut off cut in range 0-75 degree centigrade AC 230 V suitable for storage type geyser 50 ltr capacity complete all as specified and directed..
S&F in repair of white hylam sheet of size 10" x 8" x 2 mm thickness including nut and washer fixing on wall complete all as specified and directed.
S&F in repair of white hylam sheet of size 6" x 4 " x 2 mm thickness including nut and washer fixing on wall complete all as specified and directed.
S&F in repair of PVC rectangular block for mounting, switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed.
S&F in repair of white cover plate with frame 2 module complete all as specified and directed.
S&F in repair of white cover plate with frame 4 module complete all as specified and directed.
S&F in repair of modular metal flush box 2 module complete all as specified and directed.
S&F in repair of modular metal flush box 4 module complete all as specified and directed.
Note for item No 99 to 235:- 1. The contractor's site supevisor/site engineer shall be report at 0900 hrs daily excluding Sunday & holiday to collect the complaints/job card & complete the same complaint provided by JE E/M within 48 hours 2. If the complaints are not attended within stipulated time period, contractor shall be liable for recovery as follows: - (a) After 48 Hrs, Rs - 1000.00 Per complaint per day. 3. The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at DRDO area. 4. The contractor has to produce job card duly signed by user & JE E/M to Engineer-in-charge.
HONEY COLLECTION
M/s Adhikari construction co.
Flint India
SNOWY ENGINEERING INC
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .