Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoting | |
| 2 | L2₹29.6 L+₹1.8 L (6.63%)Rejected-AOC | L2 | Rejected-AOC Rejected being higher quoting | |
| 3 | L3₹31.2 L+₹3.4 L (12.4%)Rejected-AOC 00 BALAJI ENTERPRISES NEW ROAD NEW ROAD RATLAM MADHYA PRADESH 457001 | RATLAM | MADHYA PRADESH | 457001 | L3 | Rejected-AOC Rejected being higher quoting | |
| 4 | L4₹33.2 L+₹5.4 L (19.6%)Rejected-AOC | L4 | Rejected-AOC Rejected being higher quoting | |
| 5 | L5₹33.6 L+₹5.8 L (20.8%)Rejected-AOC H NO 12 ADRASH SAINIK ENCLAVE HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L5 | Rejected-AOC Rejected being higher quoting |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
14 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Hisar
Garrison Engineer Hisar Military Station Hisar 125006
CA No GE(H)-54/2021-22 COMPREHENSIVE MAINT OF INTERNAL ELECTRIC SUPPLY OF OTM ACCN UNDER GE HISAR AT HISAR MIL STN
2021_MES_497988_2
CA No GE(H)-54/2021-22
Open Tender
Miscellaneous Works
Item Rate
270 days
Hisr Mil Stn
As per Tender documents
7 documents required · 7 mandatory
₹500
GE Hisar
₹70,000
Yes
24 Mar 2022
28 Feb 2022
16 Mar 2022
28 Feb 2022
14 Mar 2022
8 Mar 2022
60 days
Amount
Taking down carefully copper/aluminium point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks, DB, MCB etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 1.00 (here-in-before) but excluding existing concealed conduit.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including cutting chases in walls and including concealed PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc including sunk type pressed steel box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).'
All as per item No 3.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 3.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 3.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per serial item No. 3.00 (here-in-before) but for one bell/buzzer point controlled by one bell push.
All as per srl item No. 3.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi stranded on independent board including provn of 2.50 Sqmm unsheathed, multistranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge.
M & L for point wiring for one light controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FRLS drawn through existing rigid PVC coduit and conduit accessories/PVC casing caping in existing concealed type in walls/ceilings and including change of steel terminal sunken boxes and 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLS connected to common earth dolly complete complete all as specified and directed by Engineer-in-charge. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).
All as per item No 9.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 9.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 9.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per item No. 9.00 (here-in-before) but bell/buzzer point controlled by one bell push.
All as per item No. 9.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi stranded on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts all as specified & directed.
S&F switch piano flush type, single pole, one way, 15 Amp, 230 Volts.
S&F flush type socket outlet multipurpose 3 Pin 5/6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed.
S&F flush type socket outlet multipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed.
S&F lamp holder, insluated body, with back plate suitable for batten fittings & complete all as specified & directed.
S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
S&F Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed.
S&F bell push flush type, 5 Amp 240 Volts.
S&F Bell ding dong type, AC, 230 Volts, single pole.
S&F sheet metal enclosure distribution board SP&N, 8 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Indo Asian Cat Part No 810321 or equivalent of makes mentioned in list of makes here-in-after .
S&F sheet metal enclosure distribution board TP&N, 4 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Indo Asian Cat Part No 810336 or equivalent of makes mentioned in list of makes here-in-after .
S&F MCB SP, 6 to 32 Amps 240 Volts , 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F MCB SPN, 32 Amps 240 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F MCB TPN, 63 Amps 415 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- Two lengths of 6 Sqmm cable, one length of 6 Sqmm cable and one length of PVC conduit will be measured as one length.
All as per item No 29.00 (here-in-before) but cable drwan through existing surfaces/concealed conduit including taking out existing unserviceable sub main wiring.
S&F LED light fitting 1x18W, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack all as specified and directed. Make : Havells Cat Part No LHEXACP7PN1W018 of Havells or Surya Cat Part No 18W - G LINE ECO or equivalent of makes as mentioned in Appx 'C' list of makes.
S&F sheet metal enclosure Single pole and neutral with a two pin and earth plug and socket complete with and including one 20 Amp SPN MCB 'C' curve complete all as specified. Make :- Indo Asian Cat Part No 810394 or equivalent of makes mentioned in list of makes here-in-after .
S&F in replacement street light LED light fitting 18/20 Watt, pressure die cast housing with epoxy powder coating, IP65, connected with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to shape out of GI pipe 40mm dia light grade 1.5m length and fixed with MS clamps of size 40x5mm - 2 Nos, nuts, bolts and washers fixed on wall all as specified and directed. Make : Cat Part No ENDURAPEARLSL20WLED757SASYTOPCMP of Havells, Cat No SSK-SLF-CF-18W of Syska, Cat No LTESSI20WLED of C&S or equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
S&F in replacement metal socket outlet (enclosure type) single phase, 20A, 2P+E, 230 V conform to IS 8804 suitable for geyser and AC etc complete all as specified and directed. Make :- Indo Asian Cat Part No 810390 or equivalent of makes mentioned in list of makes here-in-after .
S&F in replacement sheet metal enclosures with sockets plug top and MCBs single pole enclosure with a two pin and earth plug and socket complete with one single pole MCB of 32 Amp rating 240 volts etc complete all as specified and directed. Make :- Indo Asian Cat Part No 810393 or equivalent of makes mentioned in list of makes here-in-after .
S&F in replacement sheet metal enclosure distribution board SP&N, 8 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs conforming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Indo Asian Cat Part No 810321 or equivalent of makes mentioned in list of makes here-in-after .
S&F in replacement sheet metal enclosure distribution board TP&N, 4 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs conforming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Indo Asian Cat Part No 810336 or equivalent of makes mentioned in list of makes here-in-after .
S&F in replacement MCB SP, 6 to 32 Amps 240 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F in replacement MCB SPN, 32 to 40 Amps 240 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F in replacement MCB TPN, 63 Amps 415 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F in replacement bell electric Ding Dong, AC, 230 V, single Pole.
S&F in replacement sheet laminated 3mm thick including cutting into required size drilling holes for mounting switch, sockets, regulators all as specified and directed.
S&F in replacement PVC flexible cable 3 core 23/0.0076 copper conductor all as specified and directed.
S&F in replacement rotor type bipin holder suitable for tube light fitting all as specified and directed.
S&F in replacement capacitor 2.5 to 3.15 MFD as per existing capacity of 240 volts AC all as specified and directed.
S&F in replacement switch piano, flush type one way 5/6 Amps single pole mounted all as specified and directed.
S&F in replacement switch piano, flush type two way 5/6 Amps single pole mounted all as specified and directed.
S&F in replacement bell push, flush type, 5/6 Amps single pole mounted all as specified and directed.
S&F in replacement switch piano, flush type one way 15/16 Amps single pole mounted all as specified and directed.
S&F in replacement socket outlet 3 pin 5/6 Amp multi purpose piano, flush type all as specified and directed
S&F in replacement socket outlet 5 pin 15/16 Amp multi purpose piano, flush type all as specified and directed
S&F in replacement ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate all as specified and directed.
S&F in replacement lamp holder of PVC / Polycarbonate type surface for CFL / bulb etc complete all as specified and directed.
M&L for cutting chases in brick wall/PCC walls for taking out blocked concealed conduit and S&F new rigid non-metallic PVC conduit 25mm dia with accessories and making good the surface in cement mortar (1:3) and finish to match the existing surface etc complete all as specified and as directed by Engineer-in-Charge. Note : Wiring required for replacement shall be measured and paid separately under respective items.
S&F in replacement rigid non-metallic PVC conduit 25mm dia with fittings like tees , bends, elbow, reducer, bell mouth tube ends and fixing accessories such as coupler lock, nuts, saddles, pipe hooks etc complete fixed on wall / ceiling all as specified and as directed.
S&F in replacement rigid non-metallic PVC conduit 20mm dia with fittings like tees , bends, elbow, reducer, bell mouth tube ends and fixing accessories such as coupler lock, nuts, saddles, pipe hooks etc complete fixed on wall / ceiling all as specified and as directed.
S&F in replacement Ceiling fan regulator electronic dimmer type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan all as specified and directed
S&F in replacement Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan all as specified and directed
S&F in replacement single core copper conductor cable 1.5 Sq mm PVC insulated, FRLS unsheathed multistranded 1100 volts grade.
S&F in replacement single core copper conductor cable 2.5 Sq mm PVC insulated, FRLS unsheathed multistranded 1100 volts grade.
S&F in replacement single core copper conductor cable 4.0 Sq mm PVC insulated, FRLS unsheathed multistranded 1100 volts grade.
S&F in replacement single core copper conductor cable 6.0 Sq mm PVC insulated, FRLS unsheathed multistranded 1100 volts grade.
S&F in replacement PVC casing and caping of 15mm width all as specified and directed.
S&F in replacement PVC casing and caping of 20mm width all as specified and directed.
S&F in replacement LED tube rod having polycarbonate reform 09/10 W, 2 feet for existing tube light fitting, all as specified and directed. Make : Surya Cat Part No SLE TL-DS 09 PC Reform or Cat No Cat No OF PHOTONULTRAE2.01213T8SSTL09WLED865SPC Havells or equivalent of makes as mentioned in Appx 'C' list of makes.
S&F in replacement LED tube rod having polycarbonate reform 18/20 W, 4 feet for existing tube light fitting, all as specified and directed. Make : Surya Cat Part No SLE TL-DS 18 PC Reform or Cat No LT4F20WLEDT8/WDI of C&S, Cat No OF PHOTONULTRAE2.01213T8SSTL20WLED865SPC Havells or equivalent of makes as mentioned in Appx 'C' list of makes.
S&F in replacement LED light fitting 1x22W, decorative ultra slim square profile aluminium LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack all as specified and directed. Make : Havells Cat Part No LHEXBTP7IN1S022 of Havells or Surya Cat Part No 22W - STELLA or equivalent of makes as mentioned in Appx 'C' list of makes.
S&F in replacement LED light fitting 1x20W, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack all as specified and directed. Make : Havells Cat Part No LHEXACP7IN1W020 of Havells or Cat part No LTTB4F20WLEDEW BATTEN of C&S or Surya Cat Part No 20W - G LINE ECO equivalent of makes as mentioned in Appx 'C' list of makes.
S&F in replacement LED light fitting 1x18W, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack all as specified and directed. Make : Havells Cat Part No LHEXACP7PN1W018 of Havells or Surya Cat Part No 18W - G LINE ECO or equivalent of makes as mentioned in Appx 'C' list of makes.
S&F in replacement LED recess mounting panels 2 feet x 2 feet luminaire of capacity 36 watt suitable to be fixed in ceiling having extruded aluminium frame and super bright LEDs of complete all as specified and directed. Make : Surya Cat Part No SLE FP 36 R22 or Cat Part No VENUSNEOHE2X2R36WLED840PIRSENSOR of Havells or Cat Part No LTCRP36WLED2X2 of C&S or equivalent of makes as mentioned in Appx 'C' list of makes.
S&F in replacement new generation LED flood light fitting 90/100 watt on wall / ceiling high bay with lumious efficacy IP-65 protected front tightened glass with discrete high power including reflector complete all as specified and directed. Make : Syska Cat Part No SSK-BLS--90W or Polycab Cat Part No PCGLF T1 02 100 or Cat No SAUCERNEOP100WLED7576ODLTG of Havells equivalent of makes as mentioned in Appx 'C' list of makes.
S&F in replacement sunk type pressed steel terminal box of size 8" x 10" (made as per IS 5133).
S&F in replacement sunk type pressed steel terminal box of size 7" x 4" (made as per IS 5133).
S&F in replacement sunk type pressed steel terminal box of size 4" x 4" (made as per IS 5133).
S&F in replacement wooden board of size 8" x 10" made out of seasoned second class hardwood.
S&F in replacement wooden board of size 7" x 4" made out of seasoned second class hardwood.
S&F in replacement wooden board of size 4" x 4" made out of seasoned second class hardwood. Note for Srl Item No 35.00 to 78.00:- (i) These items should be executed for daily complaints received at MES service centre and details of replacement of items have to be entered in complaint register against complaint number given to contractor. (ii) The complaint slip/job card shall be prepared round the clock by the MES Staff and Supervisor of contractor and shall be handed over to contractor’s tradesmen. Complaint slip shall be got singed by user with name, number and rank and return the same to MES staff by same day. Complaints of emergent nature e.g no light, short circuiting and earth fault etc. shall be attended on priority as directed by Engineer-in-charge . In case of complaint has not been attended within stipulated time frame as per its priority nature necessary penalty at the rate of Rs. 250/- per complaint per day shall be imposed and recovered from the contractor. (iii) Bldgs requiring major nature of work e.g rewiring of complete bldg or major repair work shall be intimated to Engr-in-Charge for record and decision. (iv) Details of minor repair / replacement shall be recorded in register duly signed by the contractor / JE / EIC showing Bldg No, Name of occupant and date of repair / replacement. (v) All material required for replacement/repair will be deposited to MES stores and the same will be issued by MES staff to contractor/rep of contractor for rectification / replacement (vi) Contractor shall provide the complain slip booklet required for throughout the contract period containing 100 pages in duplicate of size 5 inch x 8 inch properly binded and printed with their Firm Name and Tele phone numbers as per sample and directed by Engineer in Charge.
M/S KAVITA CONSTRUCTION
Balaji Enterprises
m/s Rajesh Kumar
virendra constructions
M/s Devendera construction
fauji electric works
moti construction company
VERMA BROTHERS
M/S D.N Choudhary
M/s INDER CONSTRUCTION COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .