| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹6.4 L+₹2.1 L (47.8%)Rejected-AOC | L2 | Rejected-AOC Being L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical G 1 27 A GAURAV APARTMENT INDRAPURI BHOPAL MADHYA PRADESH 462023 | BHOPAL | MADHYA PRADESH | 462023 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
16 Jun 2022, 3:30 pmClosed
SE 400 KV Testing MPPTCL Bhopal
Block G-1, MPPTCL Administrative Building, Bijlinagar Govindpura Bhopal
Providing and fixing of remote CCTV Surveillance system and to make it operational at 132 KV Substations Raisen and Bareli under Testing Division-II MPPTCL Bhopal
2022_MPPTC_207300_1
TS-04/22-23
Open Tender
Security System
Item Rate
60 days
Raisen and Bareli
Please refer Tender documents.
10 documents required · 10 mandatory
₹560
₹10,000
Yes
30 Nov 2022
26 May 2022
17 Jun 2022
26 May 2022
16 Jun 2022
26 May 2022
CCTV Suviellance System
Network based IP Dome (indoor) Array outdoor Camera (2 MPX,3.6 mm, 36ir led, (indoor) 960 PCAT 6 cable and accessories with installation) as per technical specification mentioned in Annexure-A of Ehawk /Sony/Samsung/ panasonic/ securus/Digicom or any equivalent make preferably other than chaina make fitted at a location to monitor main gate including interconnection with NVR as per direction of Engineer in charge.
Network based IP bullet (outdoor) Array outdoor Camera (4 MPX 6.0 mm, 36ir led, (outdoor) 960 PCAT 6 cable and accessories with installation) as per technical specification mentioned in Annexure-B of Digicom Ehawk /Sony/Samsung/ panasonic/ securus/Digicom or any equivalent make preferably other than chaina make fitted at a location to monitor main gate including interconnection with NVR as per direction of Engineer in charge.
Network video recorder 4 MPX support (NVR) (16 channel online NVR ,P2P Built in DNS , support mobile surveillance, full HD 1080p, Accessories 2TB HDD for recording) as per technical specification mentioned in Annexure-C(ii) of Ehawk /Sony/ Samsung/ Panasonic/ Securus/ Raysharp or any equivalent make preferably other than chaina make , fitted with 2 TB of hard disk of Seagate or any equivalent make preferably other than chaina make for storage of data in Control room, at local end including interconnection with Camera installed at different locations, interconnection with modem, local Display unit as per direction of Engineer in charge. Installation of necessary software & application program etc. compatible for online display of CCTV surveillance system along with facility for online operation of Cameras both at local & remote end with provision for security for online view.
(P to MP) Point (camera) to multipoint connection (nvr) via Ethernet cable or wireless system for IP camera placed at control room building & gantry column within substation yard , with 8 Port LAN switch as per technical specification mentioned in Annexure-D (wired connection via CAT6 wire will be preferred for the indoor/outdoor camera and if it exceed 30 mtr from NVR than wireless connection should be provided)
A switched-mode power supply (SMPS) 12V/1-10Amp as per technical specification mentioned in Annexure-E
LAN switch; 16 port Gigabit switch as per technical specification mentioned in Annexure –F
Junction box; weatherproof box for LAN switch, SMPS power board at camera end as per the technical specification mentioned in Annexure-G
4U Rack box for NVR and LAN switch for interconnection of NVR and LAN switch placed inside the control room with lock system as per the technical specification mentioned in Annexure-H
Fitting material; Pole mounting for P2P and camera as per technical specification mentioned in Annexure-I
Power board; Power board with 3 power socket and MCB for P2P and SMPS as per technical Specification mentioned in Annexure-J
24 inch IPS LED FHD Monitor as per technical specification mentioned in Annexure-K(i) of Samsung/LG/Sony/HP or any equivalent make preferably other than chaina make fitted in Control room at local end for display of Camera installed in yard & control room including necessary interconnections & auxiliary supply by cabling as per direction of Engineer in charge
CAT 6 cable (Actual required after 20 meters for dome camera and 30 meters for bullet as well as ptz camera)
MOHD AKIL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .