Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC R O 218 05 OPP J D A COMPLEX TRIKUTA NAGAR JAMMU J K PIN 180020 | JAMMU | JAMMU AND KASHMIR | 180020 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹11.3 L+₹41,593 (3.82%)Rejected-AOC B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹12.2 L+₹1.3 L (12.0%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹12.4 L+₹1.5 L (14.1%)Rejected-AOC GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹12.6 L+₹1.7 L (15.7%)Rejected-AOC | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹27,700
Closing Date
4 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE JAMMU
HQ CWE JAMMU PIN 900172 c/o 56 APO
UPGRADATION OF TRANSFORMER AT SATWARI OFFICER ENCLAVE UNDER GE SATWARI
2021_MES_471866_1
CWE/JP-41/2021-22
Open Tender
Support/Maintenance Service
Item Rate
180 days
AOR GE SATWARI
Class E, Cat b(ii)
9 documents required · 9 mandatory
₹500
Yes
GE Satwari
₹27,700
Yes
24 Nov 2021
31 Aug 2021
9 Oct 2021
31 Aug 2021
4 Oct 2021
20 Sept 2021
90 days
Amount
Supply, installation, testing and commissioning outdoor type,step down transformer 11000/433 volts (at no load) AC, 3 phase 50 Hz capacity 250 KVA, core type, double copper wound,oil immersed,naturally cooled,oil natural, Air natural (ONAN) with external cooling fins, delta connected on primary side (HV) star connected on secondary side (LV) in accordance with vector symbol, DYN 11 (vector group) with neutral brought out on secondary side (LV side) and having tapping at + 2.5% to +7.5% HV side to be changed by means of hand operated off load tap change gear. The maximum temperature rise should not exceed 45 degree celcius in oil and 55 degree celcius in HV.LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celcius. The transformer shall be IS:1180 Part-1:2014 (Level-II) and BEE Certified and shall comprise of the followings:-
03 Nos porcelain bushing with arcing horn on HV side suitable for 11 KV complete withbushing,copper rods, nuts and washers.
One cable box on LT side ( Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers, with two Nos cable gland suitable for reception/taking out of XLPE insulated heavy duty armoured cable including gland, joint and jointing materials complete.
Oil conservator with filter type frain valve and oil level gauge.
De- hydrating breather with first fill dehydrating agent (silica gel).
Explosive vent.
Thermometer pocket on tank cover.
Rating plate and terminal making plate.
Oil level gauge.
Oil drain/ fillter valve.
Lifting lugs.
Oil filling hole with cap/plug with connecting plate complete.
Air release valve plug.
Four plain solid cast steel detachable rollers.
Extra bushing for neutral , outside the LT cable box for providing independent earthing for neutral.
One No 100mm dia, dial type thermometer, vapour pressure type having range 0-120 degree Celsius with resisting temperature indicator with resisting device for transformer.
Two earthing terminals on tank cover to facilitate of 32X6mm galvanised iron earth strip for earthing of body.
First filling of new and unused transformer oil IS-35/93 (fourth revision) marked filtered and tested up to 40 KV dielectric strength at 2.5 mm air gap between testing
Note:- (i) Certificate of dielectric strength shall be submitted by the contractor after filling the oil.
Supply, laying and testing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty earthed) with aluminium conductor, 11 KV, grade cross sectional area 95 Sqmm 3 Core laid in trenches/road crossing/on wall etc complete and all as specified & directed by Engr-in-Charge.
Supply, laying and testing underground LT Cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor. 1100 volts grade, cross sectional area 95 sq mm 3.5 core size all as specified & directed by Engr in Charge.
Supply, laying and testing underground LT Cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor. 1100 volts grade, cross sectional area 70 sq mm 3.5 core size all as specified & directed by Engr in Charge.
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 m depth for foundation laying of cable etc or for shaft wells cesspits manholes per holes etc 10sqmm on plan and n.exe 1.5m in depth and getting out in any type of soil .complete all as sepecified & dirceted by EIC.
All as per item No 5 above but exceeding 1.5 mtr and not exceeding 3 mtr depth. complete all as sepecified & dirceted by EIC.
PCC 1:3:6 type C-2 using 40mm graded stone aggregate for foundation of pole/stay/strut etc complete all as specified.
PCC 1:2:4 type B-1 using 20mm graded stone aggregate for pole pedestal including necessary form work etc complete all as specified.
Returning, filling in incl. spreading, leveling, watering and well ramming in layers not exc. 25 cm thick in any type of soil complete all as specified and directed by Engineer-in-charge.
Removing excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as sepecified dirceted by engr-in-charge.
Providing dry river sand as in sand cushioning to under ground cable including punning down of sand inlayers as specified and as directed.
Supply and laying dry bricks over cable laid in trenches as mechanical protection to cable with width equal to the length of bricks with well burnt sub class 'B' bricks complete all as specified
Cross arms bracing support clamps, back plate etc fabricated from structural steel section with bolts, nuts, washers,welding, bending cold or hot,drilling holes for bolts in any shape and size as directed or indicated and painted with one coat of red oxide primer and two coats of aluminium paints.complete all as sepecified dirceted by engr-in-charge.
Danger notice plate 250 mm x 200 mm made of mild steel sheet 1.6mm thick & vitreous enamelled white on both sides and with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 11 KV as required.complete and all as specified directed by engr-in-charge.
Supply, installation & testing of Air break, gang operated switch with 15 Nos insulators, outdoor type pole, mechanically operated, suitable for vertical operations, single break, provided with locking arrangement (including 50mm Godrej lock with two keys) mounted on and including steel frame and HT post type insulators copper alloy, high pressure, with operating mechanism having operating rod of 20 mm dia GI pipe (medium grade) operating from 1.2m above GL complete including drop out fuses conforming to IS-1318 of 1972, rated voltage 11 KV and for current rating 200 Amp complete all as specified & directed.
Supply & Errecting truelly vertical position steel tubular swaged poles complete with CI base plate, finial taper plug bolts, nuts & screws 11.0 mtr long type 410 SP-55 conforming to IS 2713 (Part 1 to 3, 1980 including two coat of synthetic enamelled aluminium paint over a coat of primer. Five strips of 300mm width alternate black and white paint of approved make should be provided on pole from the PCC bed complete all as specified and directed.
Lightning arrestors (set of three), expulsion type, HT metal oxide surge arrestor polymeric type, complete with all fittings, transmission class rated voltage 125 KV contionous operating voltage at 8/20 impulse, 75 KV discharge capacity 65 Kilo amp suitable for 11000 volts complete all as specified and directed
Outdoor type cable end termination jointing kit heat shrinkable complete with all accessories and jointing materials suitable mounting on channel/angle iron with and incl cable pieces of suitable size length and line type vice for 3 core 95 Sqmm XLPE HT cable (kit shall be not older than 3 months from the date of manufacture) complete all as specified and directed
Outdoor type cable straight through jointing kit heat shrinkable complete with all accessories and jointing materials with and incl cable pieces of suitable size length and line type vice for 3 core 50 to 95 Sqmm XLPE HT cable (kit shall be not older than 3 months from the date of manufacture) complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cm x60cmX6 mm thick buried directly in ground to a depth not less than 3 mtr below normal ground level with top edge of earth plate at a depth not less than 2.25 mtr below ground level, earth plate surrounded by 15 cm thick packed layer of charcoal, magnicium sulphate, common salt and connected with in and including GI strip of size 32x6mm by means of stainless steel bolts, nuts, check nuts and washers connected to Transformers / panels. 40mm bore of GI pipe (light grade) from earth plate up to testing point for protection of GI strip and 20 mm bore GI pipe (medium grade) with wire mesh and funnel for watering including necessary excavation and earth work, (in any type of soil) PCC chamber (1:3:6) type C-2 with RCC cover with suitable size of handle made out of 8mm dia MS bars and angle iron 40 x 40x 3mm frame for cover complete all as shown in electrical plate No 3 of MES schedule Part I of SSR 2009 complete all as specified. RCC cover shall be painted with red paint over a primer coat and the rate include in the unit rate of item
Earthing complete with galvanized steel earth plate electrode 60 cm x60cmX6 mm thick buried directly in ground to a depth not less than 3 mtr below normal ground level with top edge of earth plate at a depth not less than 2.25 mtr below ground level, earth plate surrounded by 15 cm thick packed layer of charcoal, magnicium sulphate, common salt and connected with in and including GI wire of 4mm dia by means of stainless steel bolts, nuts, check nuts and washers connected to Transformers / panels. 40mm bore of GI pipe (light grade) from earth plate up to testing point for protection of GI strip and 20 mm bore GI pipe (medium grade) with wire mesh and funnel for watering including necessary excavation and earth work, (in any type of soil) PCC chamber (1:3:6) type C-2 with RCC cover with suitable size of handle made out of 8mm dia MS bars and angle iron 40 x 40x 3mm frame for cover complete all as shown in electrical plate No 3 of MES schedule Part I of SSR Part-I 2009 complete all as specified. RCC cover shall be painted with red paint over a primer coat and the rate include in the unit rate of item
Supply, installation, testing & commissioning of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level and Comprising the following items :-
01 set of 400 Amps TPN aluminium bus bar of suitable length and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts.
MCCB 400 Amp 4 pole 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.422007 or equivalent to Schneider(NSX)/Siemens(3VL) - 01 No as incoming
MCCB 200 Amp 4 pole 25 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat Part No. 420218 or equivalent to Schneider(NSX)/Siemens(3VL) - 01 Nos as outgoing
MCCB 4 pole 100 Amp, 16 KA with thermal & fixed magnetic release with Ics=100% Icu. conferming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and overload protection:12 IN Make:- Legrand dpx3 Cat Part No 420013 equivalent make of SIEMENS (3VL) - 02 Nos
LED Indicating lamp (RYB-one set)
Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box shall be as per specification of CPRI width of the panel not less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the rate as quoted by contracor and No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing).
GI pipe light grade 100mm bore under road, path or along poles as cable protection pipe complete and all as specified & directed by EIC
Construction of Plateform for installation of transformer with and including Earth work, Brick work, PCC, RCC, Plastering, chain link fencing, gate etc all as shown in Drawing No CWE/TD-230/2021 Sheet 1/1 dated 23 Jun 2021, complete all as specified and directed.
SATISH AND CO
M/S S K Electricals Regd
Amit Enterprises
BMMJ TRADERS AND ENGINEERS
M/S ASHOK KUMAR SURI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .