| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | L1 | Accepted-AOC Admitted | |
| 2 | L2₹18.1 L+₹3.2 L (21.3%)Rejected-Finance NO 12 25 26 KATHIRAVAN NAGAR MAHALINGAPURAM PO POLLACHI COIMBATORE 642 002 | COIMBATORE | TAMIL NADU | 642002 | L2 | Rejected-Finance Being Not Lowest Tenderer | |
| 3 | L3₹20.4 L+₹5.5 L (36.6%)Rejected-Finance | L3 | Rejected-Finance Being Not Lowest Tenderer |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
29 Oct 2021, 6:00 pmClosed
GE Wellington
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
REPAIR REPLACEMENT AND IMPROVEMENT OF LT OH LINE ACSR CONDUCTOR LT UG CABLES LT SWITCH GEARS LT PANEL POLES WITH ACCESSORIES EARTHING ETC OF AVA HILL FARM AREA ASC AND MANDIR LINE AREA MH GORKHA CAMP MRC OFFICER MESS SINGARATHOUPPU AND LONG RANGE
2021_MES_467548_2
8661/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Wellington
As per Tender Documents
4 documents required · 4 mandatory
₹500
GE Wellington
₹34,000
Yes
22 Nov 2021
1 Oct 2021
5 Nov 2021
1 Oct 2021
29 Oct 2021
1 Oct 2021
Amount
Supply, testing and replacement of LT UG Cable, 1100 volts grade, XLPE insulated screened PVC bedded, Galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor of size 10 Sqmm x 2 Core laid in trenches / ducts, fixed on wall / inside panel, drawn through pipe including taking out old unserviceable LT cable complete all as specified and directed.
Supply, testing and replacement of LT UG Cable, 1100 volts grade, XLPE insulated screened PVC bedded, Galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor of size 16 Sqmm x 2 Core laid in trenches / ducts, fixed on wall / inside panel, drawn through pipe including taking out old unserviceable LT cable complete all as specified and directed.
Supply, testing and replacement of LT UG Cable, 1100 volts grade, XLPE insulated screened PVC bedded, Galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor of size 16 Sqmm x 4 Core laid in trenches / ducts, fixed on wall / inside panel, drawn through pipe including taking out old unserviceable LT cable complete all as specified and directed.
Supply, testing and replacement of LT UG Cable, 1100 volts grade, XLPE insulated screened PVC bedded, Galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor of size 25 Sqmm x 3½ Core laid in trenches / ducts, fixed on wall / inside panel, drawn through pipe including taking out old unserviceable LT cable complete all as specified and directed.
Supply, testing and replacement of LT UG Cable, 1100 volts grade, XLPE insulated screened PVC bedded, Galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor of size 50 Sqmm x 3½ Core laid in trenches / ducts, fixed on wall / inside panel, drawn through pipe including taking out old unserviceable LT cable complete all as specified and directed.
Supply, testing and replacement of LT UG Cable, 1100 volts grade, XLPE insulated screened PVC bedded, Galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor of size 120 Sqmm x 3½ Core laid in trenches / ducts, fixed on wall / inside panel, drawn through pipe including taking out old unserviceable LT cable complete all as specified and directed. Note for item No 1 to 6: Rate deemed to be inclusive of conecting up with control gear including cable glands and cable lugs complete.
Supply and replace cable route indicator cast iron of dia not less than 100 mm duly embossed as LT with 32mm X 6 mm MS Angle welded and foundation with PCC 1:3:6 type C1 using 20 mm graded aggregate complete all as specified and directed
Supply, install, test and commission LT Panel board, TPN 415 Volts, 50 Hz, 400 Amps capacity out door cubical type CPRI approved floor mounted factory made double door dust and vermin proof, IP-54, fabricated out of CRCA sheet not less than 3.15 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50X50X6mm with cable chamber for incoming and outgoing connections comprising for the following including necessary PCC foundation of minimum 0.35m height positioned and fixed with suitable nuts, bolts, washers etc to the MC pedestal and connecting all incoming and out going cables using necessary cable glands all as specified and directed :- (a) INCOMING:- MCCB 4 Pole, 25 KA, 250 Amps 415 Volts - 1 No (b) OUTGOINGS:- (i) MCCB 4 Pole, 25 KA, 100 Amps 415 Volts - 2 Nos (ii) MCCB 4 Pole, 16 KA, 63 Amps 415 Volts - 2 Nos (iii) MCCB 4 Pole, 16 KA, 40 Amps 415 Volts - 2 Nos (iv) MCB SPN 32 Amps - 4 No (c) 400 Amps aluminium busbar for phase and 300 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulators in separate compartment - 01 Set (d) Digital multi function panel meter for measuring voltage, Amps and Frequency with suitable CTs and back up protection - 1 No (e) LED type Indication lamp 240 Volts Set of three - 1 Set
Supply, install, test and commission LT Panel board, TPN 415 Volts, 50 Hz, 600 Amps capacity out door cubical type CPRI approved floor mounted factory made double door dust and vermin proof, IP-54, fabricated out of CRCA sheet not less than 3.15 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50X50X6mm with cable chamber for incoming and outgoing connections comprising for the following including necessary PCC foundation of minimum 0.35m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal and connecting all incoming and out going cables using necessary cable glands all as specified and directed :- (a) INCOMING:- MCCB 4 Pole, 35 KA, 400 Amps 415 Volts - 1 No (b) OUTGOINGS:- (i) MCCB 4 Pole, 25 KA, 200 Amps 415 Volts - 2 Nos (ii) MCCB 4 Pole, 25 KA, 100 Amps 415 Volts - 1 No (iii) MCCB 4 Pole, 16 KA, 63 Amps 415 Volts - 1 No (iv) MCB SPN 40 Amps - 4 Nos (c) 600 Amps aluminium busbar for phase and 400 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulators in separate compartment - 01 Set (d) Digital multi function panel meter for measuring voltage, Amps and Frequency with suitable CTs and back up protection - 1 No (e) LED type Indication lamp 240 Volts Set of three - 1 Set
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/ loose soil for laying of under ground cable and foundation of poles.etc complete all as specified and directed.
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25 Cm thick, complete all as specified and directed.
Removal of excavated surplus soil not exceeding 50 m and depositing where directed at al level not exceeding 1.5 m above the starting point and all as specified and directed.
Supply and spreading clean dry riddled sand in trenches for cushioning all as specified for cable protection in trenches / ducts complete all as specified and directed. Note: The punned down thickness shall only be measured
Bricks sub class 'B' to be laid over dry sand cushinoing in trenches as protection to cable all as specified and directed.
Cement concrete (1:3:6) type C1 with 20 mm graded aggegate for foundation / road crossing including form work and finishing to all exposed surfaces by using extra cement all as specified and as directed.
GI Pipe galvanised light grade 80 mm dia for cable protection in trenches/ at PCC pole for loopin/loop out of cable and cable entry at Bldg/block end including taking down all as specified and directed.
GI Pipe galvanised light grade 40 mm dia for cable protection in trenches/ at PCC pole for loopin/loop out of cable and cable entry at Bldg/block end including taking down all as specified and directed.
Restringing only ACSR conductor of any type / size on existing LT/HT Pole etc including binding on to insulators with and including aluminium wire complete all as specified and directed.
Steel tubular swaged poles of complete with cast iron base plate, final taper, plate, bolts, nuts and screws as specified type 410 SP 31, 9 mtr long including dismantling of unserviceable pole complete all as specified and directed.
Earthing complete with galvanised steel plate electrode 600x 600x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of plate not less than 1.5 mtrs below normal ground level connected to galvanised iron strip of size 32x6mm from earth plate to body of the equiment by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earth in test point on completion with and including 15mm bore light grade GI protection pipe ( 7.5 mtr long) for earth including PCC (1:2:4) type B1 chamber pit with pre cast RCC (1:2:4) type B1, 40mm thick reinforced with 6mm dia MS bars @ 100 c/c bothway, lifting hooks made out of 6mm MS bars, watering aggangement with funnel, wire, common salt, charcoal filling, necessary excavation and earth work in any type of soil complete all as specified and as directed.
Taking down the deffective sealed compressor from the unit and supply and fix factory reconditioned rotory/ receprocating type compressor 1.5 Ton capacity obtained from the rechange of old compressor including cleaning the refrigeration circuit withappropriate cleaning agents, flushing throught with CO2/N2 removal of complete dirt oil and certain, etc. Pressure testing dehydration, Vacumising, charging R-22/33A gas, testing and commissioning of the 1.5 Ton capacity all as specified and as directed.
Taking out defective condenser fan blade of split type A/C 1.5 Ton capacity and supply and Fix inf new fan blade of same type balancing for smooth rotation in the casing and testing all as specified and directed.
Cleaning/ flushing out the refrigeration system thoroughly with CO2/N2. vaccumising and charging with refrigerant gas and compessor oil testing at workshop and commissioning the system of 1.5 ton capacity split/ Window type AC all as specified and directed.
Supply and fix in replacement inner unit fan motor with runner of suitable capacity for split / Window type AC of cap 1.5 ton all as specified and directed.
Supply and fix in replacement running capacitor 36/45 mfd, 3 pin suitable for split/ Window AC of cap 1.5 ton all as specified and directed. Make- Efcos, Sycap, Keltron
Supply and fix in replacement indoor fan capacitor 1.5 mfd suitable for split/ Window AC of cap 1.5 ton all as specified and directed. Make- Sriram, Reneutrol, CSR 127
Supply and fix in replacement filter suitable for split AC of cap 1.5 ton all as specified and directed. Make- Sriram, Reneutrol, CSR 127
Supply and fix in replacement indoor evaporator unit suitable for split AC of cap 1.5 ton all as specified and directed. Make-Sriram, Reneutrol, CSR 127
Supply and fix in replacement drain out pipe of required size and length of indoor unit suitable for split AC of cap 1.5 ton all as specified and directed. Make-Sriram, Reneutrol, CSR 127)
Taking out the damaged suction line pipe and supply and fixing new copper pipe of size 1/2" in brazing, pressure testing for 1.5 Ton capacity split type AC all as specified and directed.
Supply and charging of refrigerent gas R22/33A in cooling appliances after dehydration all as per standard practice testing for proper cooling effect and satisfactory performance complete all as specified and as directed.
Supply and charging of refrigerent gas R134A/R410A in cooling appliances after dehydration all as per standard practice testing for proper cooling effect and satisfactory performance complete all as specified and as directed.
Supply and fix in replacement PVC insulated and sheathed flexible cable 3 core stranded copper conductore of size 4.0 Sqmm in proper size saddle 1100 volts grade after taking out old unserviceable one including electrice connection complete all as specified and as directed.
Supply, fix in replacement relay 5 pin type suitable for 1.5 Ton capacity all as specified and as directed. Make-Sriram/ Arvind / Annapuma.
Supply, fix in replacement Over load protector suitable for 1.5 Ton capacity all as specified and as directed. Make- Sriram, Arvind/ Annapuma.
Supply, fix in replacement thermostatic switch suitable for window/ split type AC 1.5 Ton capacity all as specified and as directed. Make-Indofoss / Danfoss
Supply, fix in replacement Air conditioner Kit suitable for window / Split type AC 1.5 ton cap having cabinet box, cooling coil, condenser unit all as specified and directed. Make Samsung/ Voltas
Taking down the deffective sealed compressor from the unit and supply and fix factory reconditioned compressor obtained for the exchange of old compressor including deaning the refrigeration circuit with appropriate cleaning agents, flushing throught with CO2/N2 brazing the line . Pressore testing rectification of leakages,dehydration, Vacumising, charging R-134A gas. Replacement of copper pipe, copper strainer, topping up compressore oil incl transportation of the unit to the workshop testing and commissioning of 165 to 220 Ltrs Capacity refrigerator all as specified and directed. Make:- LG , Whirlpool, samsang.
All as per item No.31 hereinbefore but 250 to 350 Ltrs Capacity refrigerator all as specified and directed. Make:- LG , Whirlpool, samsang.
All as per item No.31 hereinbefore but Deep freezer of Capacity 200 to 300 Ltr all as specified and directed. Make:- LG , Whirlpool, samsang.
Gas charging including cleaning the refrigeration system, flushing through with CO2/N2 removal of complete dirt, oil brazing the line, pressure testing, rectification of leakages, dehydrating, vaccumising, charging of R134A gas, replacement of copper pipe, copper strainer, ropping up compressor oil including transportation of the unit to the work shop testing and commisioning the refrigerators of 165 to 220 Ltr Cap all as specified and directed.
All as per item No.41 hereinbefore but refrigerators of 250 to 350 Ltr Cap all as specified and directed. Make:- LG , Whirlpool, samsang.
All as per item No. 41 hereinbefore but Deep Freezer of capacity 200 to 300 Ltr all as specified and directed. Make:- LG , Whirlpool, samsang.
Supply, fix in replacement relay suitable for Refrigerator /deepfrezer of any capacity as per existing modal all as specified and directed. Make :-Sriram, Indfoss, Danfoss
Supply, fix in replacement overload protector suitable for Refrigerator /deepfrezer of any capacity as per existing modal all as specified and directed. Make :-Sriram, Indfoss, Danfoss
Supply, fix in replacement thermostatic switch of auto de-frost suitable for Refrigerator /deepfrezer of any capacity as per existing modal all as specified and directed. Make :-Sriram, Indfoss, Danfoss
Taking down the defective unserviceable evaporator unit and pipe connection and accessories and supply and fixing new set for refrigerator of 165 to 220 Ltr Cap all as specified and directed.
Taking down the defective unserviceable evaporator unit and pipe connection and accessories and supply and fixing new set for refrigerator of 250 to 350 Ltr Cap all as specified and directed.
Taking out unserviceable heating element and supply and fix new heating element 1.5 KW Dual clip type with rubber gasket suitable for geysers up to 25 Ltr capacity all as specified and directed.
Taking out unserviceable heating element and supply and fix new heating element 1.5 KW Round/Triangle type with rubber gasket suitable for geysers up to 25 Ltr capacity all as specified and directed.
Taking out unserviceable heating element and supply and fix new heating element 2 KW Round type with rubber gasket suitable for geysers up to 50 Ltr capacity all as specified and directed.
Taking out unserviceable heating element and supply and fix new heating element 2 KW Triangle type with rubber gasket suitable for geysers up to 50 Ltr capacity all as specified and directed.
Taking out unserviceable thermostat and supply and fix new thermostat suitable for 25 Ltr capacity geyser, range 30° C to 80° C and acting at 70°C all as specified and directed.
PVC connections 15mm size with PTMT nuts of length 450 mm all as specified and directed.
Rajapriyaconstruction
Saket Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .