Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.0 LQualified Make: Aemric
Model: Aemric 50 Lph 31 SECTOR 10 AMBALA HARYANA 134003 | AMBALA | HARYANA | 134003 | Make: Aemric
Model: Aemric 50 Lph | L1 | Qualified | |
| 2 | L2₹1.1 L+₹9,100 (8.72%)Qualified Make: Aqua prag
Model: 50LPHRO SYSTEM 0 NEAR HANUMAN MANDIR GHANS MANDI NO 2 MORAR GWALIOR MADHYA PRADESH 474006 | GWALIOR | MADHYA PRADESH | 474006 | Make: Aqua prag
Model: 50LPHRO SYSTEM | L2 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
28 May 2018, 2:00 pmClosed
Potable water purification system Potable Water Purification System ( 7 ) Technical Specifications Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier Electrically Operated Reverse Osmosis based water purifier
Gravity operated water purifier Ultraviolet (UV) LAMP Yes Yes Ultra Voilet (UV) Lamp power consumption 16 - STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection - Number of float valves/sensors 1 INPUT PARAMETERS Input Water TDS 2000 2000 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 30-40 25-35
30-40
90-100
70- 80 Output Water of RO system Conforming to Indian Standard IS 10500(latest) - Output water capacity (Litre/Hour): 50 50 1/3 Arsenic and Floride removal capability true true Misc
warranty etc Thin-film composite membrane Yes Yes
No High Pressure Pump Yes - Raw water/Chemical Raw water/Chemical Cleaning PUMP Yes Yes Pre Filter Vessels: Yes Yes Micron Filter Yes Yes
No Membrane Housing Yes Yes
No Auto cut Yes Yes No of candles (Nos) 5 5 Installation Type Floor mounted Floor mounted Warranty period ( for free replacement of machine 1 2
3
1 Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 1 2
1 Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm Yes Yes
No Chloride & Flouride removal facility Yes with Pump Yes with Pump Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 Yes - Test certificate No and date: - - Name and Address of laboratory which conducted Test: - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sakthi Ganesan 600032
10
Alandur Road
CTI Campus
Guindy
Chennai-32 7 15 2/3 EMD Required No ePBG Required No
95355
GEM/2018/B/13606
Potable water purification system
15 days
Tamil Nadu; Chennai
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Potable water purification system Potable Water Purification System ( 7 ) Technical Specifications Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier Electrically Operated Reverse Osmosis based water purifier | - | - | - |
| Gravity operated water purifier Ultraviolet (UV) LAMP Yes Yes Ultra Voilet (UV) Lamp power consumption 16 - STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection - Number of float valves/sensors 1 INPUT PARAMETERS Input Water TDS 2000 2000 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 30-40 25-35 | - | - | - |
| 30-40 | - | - | - |
| 90-100 | - | - | - |
| 70- 80 Output Water of RO system Conforming to Indian Standard IS 10500(latest) - Output water capacity (Litre/Hour): 50 50 1/3 Arsenic and Floride removal capability true true Misc | - | - | - |
| warranty etc Thin-film composite membrane Yes Yes | - | - | - |
| No High Pressure Pump Yes - Raw water/Chemical Raw water/Chemical Cleaning PUMP Yes Yes Pre Filter Vessels: Yes Yes Micron Filter Yes Yes | - | - | - |
| No Membrane Housing Yes Yes | - | - | - |
| No Auto cut Yes Yes No of candles (Nos) 5 5 Installation Type Floor mounted Floor mounted Warranty period ( for free replacement of machine 1 2 | - | - | - |
| 3 | - | - | - |
| 1 Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 1 2 | - | - | - |
| 1 Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm Yes Yes | - | - | - |
| No Chloride & Flouride removal facility Yes with Pump Yes with Pump Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 Yes - Test certificate No and date: - - Name and Address of laboratory which conducted Test: - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sakthi Ganesan 600032 | - | - | - |
| 10 | - | - | - |
| Alandur Road | - | - | - |
| CTI Campus | - | - | - |
| Guindy | - | - | - |
| Chennai-32 7 15 2/3 EMD Required No ePBG Required No | - | - | - |
Exempted
28 May 2018
16 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_95355.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .