SE ETC NOIDA
220 KV SUB STATION SECTOR 20 NOIDA
Replacement of damaged 132 kV main bus and jumpers connected therewith including supply at 220 kV S/S Sec-129 Noida under ETD-I Noida
2020_UPTCL_442663_1
E-T-86/ETCN/2019-20
Open Tender
Electrical Works
Item Rate
30 days
NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
EE ETD NOIDA
₹11,500
13 Apr 2020
3 Mar 2020
31 Mar 2020
3 Mar 2020
31 Mar 2020
3 Mar 2020
Amount
Supply
Bolted type tension fitting for twin moose conductor with turn buckle for 70 KN disc insulator suitable for main bus with hardware fitting D shackle D Socket ball hook york plate D clip tension clamp as per technical specification/sample
Bolted type tension fitting for twin moose conductor without tura buckle for 70 KN disc insulator suitable for main bus with hardware fitting D shackle D Socket ball hook york plate D clip tension clamp as per technical specification/sample
Bolted type suspension fitting for twin Moose conductor with york plate complete assembely 70KN as per technical specification/sample
Fired wedge Type 'C' connector (RPG make) suitable for moose to moose conductor heaving 1250 Amp capecity technical specification/sample
Bimetallic 132KV Isolator clamp made of Alluminium Alloy LM-6 complete with GI Nuts, Bolts and washers suitable for ACSR Twin moose conductor technical specification/sample
Bimetallic 132KV Isolator clamp made of Alluminium Alloy LM-6 complete with GI Nuts, Bolts and washers suitable for ACSR Twin Panther conductor technical specification/sample
Bimetallic 132KV CT clamp suitable for ACSR Twin moose conductor with Necessary Nuts, Bolts and washers as per technical specification/sample
Bimetallic 132KV CB clamp suitable for ACSR Twin moose conductor with Necessary Nuts, Bolts and washers as per technical specification/sample
2 Bolts 250mm specing, specer for twin moose conductor as per technical specification/sample
2 Bolts 100mm specing, specer for twin moose conductor as per technical specification/sample
Shiftting of various type substation structure and material required at 220 kv substation sec-129 Noida from diffrerent 132/220kv substations of Noida transmission Circle including loading and unloading, proper stacking with all other associated works.
Opening /cutting of old inteconnection R, Y & B Phase of 132KV Main bus I& II (72 mtrs span) section made of zebra conductor between bus Section below gentries step by step During bus bar replacement work including dismentling of all type of clamp
Dismentling of 132KV Man old bus bars I, II sections of R, Y & B phase of zebra conductor and lowering down in switch yard and complete dismentling of their fitting and shifting of all scrap material switch yard to store
Opening /cutting of existing jumpers from 132KV Main bus bar I, II and all associated clamps during replacement of bus bar of various size conductors
Erection of 132kv beam,high mast with peak and auxilary GI steel structure requared for installation of 132kv isolator after shifting the steel structure from store to site, fixing of isolator parts as per isolator installation drawing/mannual with the help of hydra/crane including testing of isolator operation for proper and hassle free operation along with
Febrication work to make the beam strucuture and difffent type auxilary structure suaitable for installation on exsiting colomns and existing isolator foundation including cutting welding bending and grinding of galvinised steel strucutre,including all other associated works to complete the work satisfactorily
Fixing of twin zebra suspension fitting under bus sections of 132KV Main Bus I, II below the gentries with suitable hardware disc insulator etc. and complete the work in all respect and shifting of material from store to work place.
Stringing and proper sagging of132 KV New main Bus I, II & III sections by twin zebra conductors including shifting of new material from store to work site and fitting of tension clamps horsing of disc insulators, tension fitting, PG clamps and specers etc. and cutting the conductors as per requirments.
Erection of 132kv bus isolator after shifting it from store to site, fixing of isolator parts as per isolator installation drawing/mannual with the help of hydra/crane including testing of isolator operation for proper and hassle free operation along with all other associated works to complete the work satisfactorily
Fixing of Fired wedge type 'C' connectors (RPG make) suitable for moose to moose conductor heaving 1250Amp capecity.
Reconnection fo main bus bar dropper jumpers from 132KV new main bus I, II to isolators by twin moose conductor after fitting of PG Clamps isolator clamps and specers etc ncludng shfting of material from store.
Reconnection of main bus below the gentry in bus section step by step durng replacements of 132KV man bus I, II of twin moose conductor by PG clamps and suspension fitting specers etc. and complete the work in all respect.'
Replacement of damage jumpers of different bay in 132KV switch yard of various conductors after opening of damage jumpers.
M/S QUADRY CONTRACTOR AND SUPPLIAR
VIDHI ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .