Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 CrAccepted-AOC | ₹15.8 Cr Quoted ₹15.9 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹17.2 CrRejected-Finance | ₹17.2 Cr | L2 | Rejected-Finance Being other than lowest |
| 3 | L3₹18.0 CrRejected-Finance | ₹18.0 Cr | L3 | Rejected-Finance Being other than lowest |
| 4 | L4₹18.1 CrRejected-Finance | ₹18.1 Cr | L4 | Rejected-Finance Being other than lowest |
| 5 | L5₹18.1 CrRejected-Finance | ₹18.1 Cr | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹16.3 Cr
EMD Value
₹11.4 L
Closing Date
26 Jul 2021, 6:00 pmClosed
Chief Engineer Lucknow Zone
HQ CE Lucknow Zone, 17, cariappa marg, Lucknow 226002
PROVN OF CHILDREN SCHOOL AT AGRA
2021_MES_435444_2
CELZ/AGR/T-12 of 2015-2016
Open Tender
Civil Works
750 days
Agra
As per NIT
8 documents required · 8 mandatory
₹3,000
₹11.4 L
Yes
7 Sept 2021
29 Jun 2021
27 Jul 2021
29 Jun 2021
26 Jul 2021
13 Jul 2021
29 Jun 2021 - 8 Jul 2021
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5.
Total amount of Sch 'A' Part II (Site clearance, excavation and earth work)
Total amount of Sch 'A' Part III (Internal Water Supply )
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (Sewage Disposal)
Total amount of Sch 'A' Part VI (Road, Path & Culvert )
Total amount of Sch 'A' Part VII (Area Drainage)
Total amount of Sch 'A' Part VIII Compound wall , fencing, and gate)
Total amount of Sch 'A' Part IX (External Water Supply )
Total amount of Sch 'A' Part X (External Electrification )
Total amount of Sch 'A' Part XI (Rain Water Harvesting)
Total amount of Sch 'A' Part XI-A (Assembly Stage, Volley Ball Court and Badminton Court)
Total amount of Sch 'A' Part XII (Demolition/ Dismantling)
Sch 'A' Part - XIII (Miscellaneous Items) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 siginifies this fact only.
INTERNAL ELECTRIFICATION Point wiring complete for One light/Fan/Exhaust Fan point controlled by one switch with PVC insualted and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Point wiring complete for One light point controlled by two way switches with PVC insualted and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and MS conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, only MS black sheet conduit ISI marked dia of coduit not less than 20 mm shall be used without any extra cost.
Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on an independent board, with PVC insualted and unsheathed FRLS CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and MS conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, only MS black sheet conduit ISI marked dia of coduit not less than 20 mm shall be used without any extra cost.
Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on same board, with PVC insualted and unsheathed FRLS CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and MS conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :-In case of roof/ceiling, only MS black sheet conduit ISI marked dia of coduit not less than 20 mm shall be used without any extra cost.
Point wiring complete with PVC insulated and unsheathed, FRLS cable 2.5 sqmm (nominal area) ,ISI marked, multi-stranded copper conductor single core including ISI marked 20mm dia PVC conduit concealed in wall and MS conduit in roof/floorslab excluding flush metal GI boxes complete,including 1.5 Sqmm,FRLS cable PVC insulated unsheathed copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, only MS black sheet conduit ISI marked dia of coduit not less than 20 mm shall be used without any extra cost.
S&F LED batten surface / wall/ Ceiling mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 FT 20 W), luminaire lumen >2000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed.
S&F LED batten surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 9 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed.
S&F LED Building security light fitting with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption <20 W (14W) & luminaire lumen >2500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers complete all as specified and directed.
S&F Mirror light Decorative ultra slim square profile liner LED lighting fixture with extruded polycarbonate body with Minimum 8 Watt & Maximum 11 Watt LED warm white in colour with a luminous efficacy of 120 lum/watt(min) with PF not less than 0.9 with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed.
Supply and fixing 50 watt ,5700K LED security Flood light made out of pressure die cast aluminium housing with toughned glass , IP66 protection and impact resistance IK07 ,mounted on top of the pole with cap type bracket having lenght not less than 0.31 meter fixed with suitable fasteners having extended arm length not less than 1.5 meter and dia not more than 43 mm and angle between pole and extended arm should be 100 to 105 degrees including fabrication work for fixing Building security light . including PVC insulated three core 23/0.0076 copper cable and includinding suitable size of pvc flexible conduit from celling rose to building security light fittings complete all as specified and directed
S&F circular slim surface LED downlighter with housing made up of die cast aluminum for better thermal management, high transmitivity non yellowing PMMA diffuser for better light output and uniform light distribution without glare, power consumption <10W, luminaire lumen>1000lm, driver and accessories to be prewired, CRI>70, LED efficiency > 120 lm/W photo biological safety report as per IEC624718 & electrical insulation class I, LED life with L70 criteries -37000 hrs colour temp >6000K, Ingress protection IP-20, ambient temperature 0 to 450C, driver efficiency >85%, THD<10% as per IEC 61000-3-2, power factor >0.95, surge protection 2.5 KV, two stages isolatated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM79 & LM80 certification.
Supply and fix decorative wall mounting Engment light chrome finish fixture with textured glass including 11 watts Red and Green LED lamp complete all as specified and directed.
Exhaust Fan high quality engineering plastic, resistant to colour change with anti- statio properties (ventil air) 200 mm sweep 35 watt ,1200 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to exhaust fan motor complete all as specified and directed.
Exhaust fan of 450 mm sweep single phase 230 Volts AC, 900 RPM, light duty, star rating with louvered shutters including mounting frame and connecting the fan to ceiling rose including provn of three core flexible copper cable of size 1.5 Sqmm not less than 0.5 mtr long for connection complete all as specified and directed.
Ceiling fan 1200 mm sweep single phase 230V AC, five star rating and ISI marked alongwith steel down rod and connecting up the fan to ceiling rose including provn of three core flexible copper cable of size 1.5 Sqmm not less than 0.5 mtr long for connection complete all as specified and directed.
Ceiling fan 1400 mm sweep single phase 230V AC, five star rating and ISI marked alongwith steel down rod and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long for connection complete all as specified directed.
MCCB 4 pole ,415 V ,AC fixed type 200 amps with breaking capacity 10 KA complete all as specified and directed.
MCCB 4 pole ,415 V ,AC fixed type 125 amps with breaking capacity 10 KA complete all as specified and directed.
MCCB VTPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed.
MCB DB single pole with neutral sheet metal enclosure double door type, 240 Volts AC, with 200 Amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed.
MCB DB single pole with neutral sheet metal enclosure double door type, 240 Volts AC, with 200 Amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 8 way complete all as specified and directed.
MCB DB single pole with neutral sheet metal enclosure double door type, 240 Volts AC, with 200 Amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 12 way complete all as specified and directed.
MCB single pole and neutral 16 to 32 Amp rating 'B' Series 240 volt complete all as specified and directed.
MCB single pole 6 to 32 Amp rating 'B' Series 240 volt complete all as specified and directed.
MCB single pole and neutral 40 to 63 Amp rating 'B' Series 240 volt complete all as specified and directed.
Submain wiring with two single core 2.5 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including 2.5 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly complete all as specified. Note:- Two single core 2.5 sqmm copper conductor, one run PVC conduit and one run of 2.5 sqmm earth wire shall be considered & measured as one unit.
Submain wiring with two single core 4 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including 4 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly complete all as specified. Note:- Two single core 4 sqmm copper conductor, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit.
Submain wiring with two single core 6 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including 6 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly complete all as specified. Note:- Two single core 6 sqmm copper conductor, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit.
M&L for Earthing complete with galvanized earth plate electrode 600 x 600 x6.3 mm thick burned directly in ground (earth pit not less than 2.5 M below normal ground level ) with top edge of the plate not less than 1.75 M below normal ground level connected to and including galvanized steel wire 4mm dia as earth lead Earth plate to pole test point including 25mm GI light grade pipe for earth protection from earth point to earth plate surrounded by 150mm thick alternate layers of charcoal dust mix all with 35% common salt, 20mm bore medium grade GI Pipe for watering PCC pit type 1:3:6 type C-1 using 20mm graded stone aggregate, with RCC 50mm thick cover in 1:2:4 Type B-1 reinforced with 8mm dia TMT bars @ 8mm c/c both way. GI check nut, funnel with wire mesh necessary excavation and earth work in any type of soil all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 complete all as specified and directed.
Supply and fixing GI wire 4 mm dia as extension of earth continuity conductor beyond 7.5 mtr for a single earthing complete all as specified and directed.
Supply and fixing GI pipe 15 mm dia light grade for machinically protection of GI wire complete all as specified and directed.
INTERNAL WATER SUPPLY Jet with flexible head & brass nozzle for 15 mm bore complete all as specified and directed.
S& F CP Urinal Spreader for urinal 50mm bore fixed with iron pipe/ PVC pipe complete all as specified and directed.
S& F CP Health faucet 15 mm bore and CP flexible pipe of min 01 mtr length fixed complete all as specified and directed.
Stainless steel sink, 1 mm thick for kitchen or laboratory, with plug, waste pipe, washers including cantilever cast iron brackets connecting union etc overall size 495 mmx420mm with bowl size 410mm x330mm x160mm complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY Supplying,design, loading, unloading, installing, testing and commissioning outdoor type floor mounted step down transformer 11000/433 volts (at no load) capacity 250 KVA, AC 3 phase 50 HZ double copper wound oil immerged naturally cooled with external cooling tube core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol DYn-11 (Vector group) with neutral brought out on secondry side (LV side) and having tapping at 2.5% interval from -7.5% to + 7.5% on HV side having facility to be changed voltage by means of hand operated off load tap changing gear. The maximum temperature rise should not exceed 50 degree celsius in oil and 55 degree celsius in HV/LV winding from ambiant temp when measured by resistance method after continious full load run in ambient temp of 40 degree celcius. The transformer shall confirm IS : 1180 and latest relavent IS and ECBC marked and shall comprise of the following :-
One cable box on HV side (primary side) with 3 Nos porcelain bushing with arcing horn suitable for 11 KV complete with bushing copper rods, nuts and washers
One cable box on LT side (secondry side) consisting of four nos percelein bushing with copper rods, complete with nuts and washers with two nos cables glands, suitable for incoming/outgoing of 3 1/2 core 630 Sqmm LT 1100 volt grade XLPE insulated & PVC Sheathed armoured heavy duty cable including glands, joint and jointing materials complete.
Oil conservater with filter type drain valve and oil level indicator gauge.
De-hydrating breather (TRANSPARENT TYPE) with first fill dehyrating agent (silica gel)
Explosive vent.
Thermometer pocket with temperature indicator on tank cover.
Two earthing terminal's on tank cover to facilitate fixing of 32x6mm galvanised iron earth strip for earthing of neutral & body.
Rating plate and terminal marking plate.
Oil drain filter valve.
Lifting lugs
Oil filling hole with cap/plug with connecting plate complete.
Air release valve
Four plain solid cast steel detachable rollers.
Extra bushing for neutral, outside the LT cable box for providing indpendent earthing for neutral.
First filling of new and unused transformer oil IS-335/93 (fourth revision) marked filtered and tested for not less than 50 KV dielectric strength at 2.5 mm air gap between testing electrodes.
Brick work foundation suitable for 250 KVA Step down transformer,having 100 mm PCC on top type C1 (1:3:6) a
Note:- certificate of di electric strength will be provided by contractor after initial filling of oil.
Supply and fixing switch air break gang operated triple pole mechanically operated mounted on HT insulator (09 insulators),Non ferrous knife & steel frame with operating mechanism including spring loaded mechanism set of three working from ground level ,consisting of GI pipe of adequate length including locking arrangement with godrej lock of current rating 200 amps for 11000 volts complete all as specified and directed by Engineer in charge.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 10 Sqmm 2 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 16 Sqmm 4 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 25 Sqmm 4 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 25 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 50 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 95 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 400 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of cable XLPE insulated screened triple enameled PVC bedded,screened with earthed semi conducting compound in combination with copper tape,inner sheath or pvc tape galvanized steel strip or wire armoured, confirming to IS-7098 part-II electric power cable (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 95 Sq mm 3 Core through pipe/road crossing in ducts, on poles, trenches etc of size 95 Sqmm 3 core complete all as specified and directed.
Supply, erecting and installation of steel tubular, swaged, pole of overall length 11 meter having maximum tensile strength 42 Kgf/mm2 of type 410 SP-55 conforming to IS-2713-1980, single swan neck made out of 50 mm dia MS pipe 1.5 mtr long to be jointed on top of LT pole incl fabrication work for fixing street light. A through hole of 14 mm dia shall be provided at height of 2.5 mtr from base plate for inserting 2 core cable from junction box to top of the pole and top portion shall be fabricated for fixing street light fittings including earth work complete with cast iron base plate, having suitable dia of hole through the pole with nuts & bolts for earthing arrangement, bottom portion of tubular steel pole having 165.10 mm outer dia in 5 meter length, 4.5 mm wall thickness, middle portion having 139.70 mm outer dia in 2 metre length 4.5 mm wall thickness and top portion having 114.30 mm outer dia in 2 meter length, 3.65 mm wall thickness of pole wall, respectively, bottom MS square plate duly painted with two coat of black bituminous paint throughout, internally and externally up to planting depth and painting remaining portion of pole with two coats of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making / pasting three nos circular strips each of 100 mm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking / stencil writing of pole numbers with black paint including necessary excavation & earth work, removing excavated soil from site complete all as specified & directed. Note :- Necessary Excavation and earth work, PCC Work for foundation / erection of pole assembly will be deemed to be included in the unit rate.
Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm thick by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B1 using (20 mm graded stone aggregate), mild steel frame made out of angle iron of size 40 mm x 40 mm x 3 mm thick duly paint with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 15 mm dia light grade GI pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No. 3 connected to earthing test point all as specified and indicated including testing on completion as directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Earthing complete with galvansided steel earth plate electrode 600 x 600 x 6.0mm thick directly burried in the ground (Earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.50M below the normal ground level, GI wire 4.0mm dia from earth plate/ electrode to test point (upto max distance of 7.50M is included in unit rate) and connected to earth plate & earth test point by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15mm bore GI pipe light grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be renderd 12mm thick plaster in CM (1:4), funnel with wire mesh of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and connection from DB to earth electrode with same GI wire alongwith protection pipe and testing on completion complete all as specified and directed.
Supply, erecting and installation of steel tubular, swaged, pole of overall length 9 meter having maximum tensile strength 42 Kgf/mm2 of type 410 SP-31 conforming to IS-2713-1980, single swan neck made out of 50 mm dia MS pipe 1.5 mtr long to be jointed on top of LT pole incl fabrication work for fixing street light. A through hole of 14 mm dia shall be provided at height of 2.5 mtr from base plate for inserting 2 core cable from junction box to top of the pole and top portion shall be fabricated for fixing street light fittings including earth work complete with cast iron base plate, having suitable dia of hole through the pole with nuts & bolts for earthing arrangement, bottom portion of tubular steel pole having 165.10 mm outer dia in 5 meter length, 4.5 mm wall thickness, middle portion having 139.70 mm outer dia in 2 metre length 4.5 mm wall thickness and top portion having 114.30 mm outer dia in 2 meter length, 3.65 mm wall thickness of pole wall, respectively, bottom MS square plate duly painted with two coat of black bituminous paint throughout, internally and externally up to planting depth and painting remaining portion of pole with two coats of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making / pasting three nos circular strips each of 100 mm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking / stencil writing of pole numbers with black paint including necessary excavation & earth work, removing excavated soil from site complete all as specified & directed. Note :- Necessary Excavation and earth work, PCC Work for foundation / erection of pole assembly will be deemed to be included in the unit rate.
Supply and fixing solar street light 20 watt LEDluminaire (lumen 2100) type including 60 AH 12 V battery,charger controller,solar panel 100 Wp, 6 mtr hot dip galvanized tubular pole,and mounting accessories,and inclusive of one coat of zinc chromates primer,one under coat and one finishing coat of good quality of alumunium paint complete all as specified and directed. NOTE- Excavation,returning and filling,bricks and PCC work measured and paid for separately
S&F LED street light with aluminum pressure die cast housing, high purity PC fresneldiffuser with silicon gaskets for IP-66 protection, power consumption < 60 W and system efficiency > 130lm /W, in built electronic driver prewired upto terminal block with driver efficiency > 85% suitable for external pole upto 35mm LED Make :- Nichia/Cree/Osram, ambient temprature range 0-450c, THD<10%, colour tempreature 6600 K, surge protectionin cm 3.0 KV, multistage constant current constant voltage operated driver with range 150 -270 V AC and safety extra low volatge safe level < 60V DC as per IEC standard including GI pipe medium grade ISI mark of size 32 mm dia length not less than 1.5 mtrs bending to shape for fixing light and nuts, bolts, clamp as required to fix to wall complete all as specified and directed.
Supply, install, testing and commissioning of LT Panel board , as per IS 61439-1&2 outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system with rated fault level of 65 KA for 1 sec with internal arc having bus bars chamber with copper bus bars duly insulated by insulation of RYB colour 600 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X6 mm duly embedded in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following :-
INCOMING MCCB 4 pole 400 amps Icu=36 kA, Ics =100% of Icu with microprocessor release and adjustable overload (min 70% to 100%) - 01 No
OUT GOING MCCB 4 pole 100 amps Icu=16KA, Ics =100% of Icu with thermal magnetic release and adjustable overload (min 70% to 100%) -01 nos
MCCB 4 pole 63 amps Icu=16KA, Ics =100% of Icu with thermal magnetic release and adjustable overload (min 70% to 100%)-07 no
MCB SPN 20 amps C series -02 nos
Multifunctional VAF meter, PF meter - 1 No
RYB Neon indicating lamp -1 set for each outgoing and incoming
MS work incl angle iron frame and PCC work
Street light timer suitable for operation of street light with necessary switchgear such as contactor,timer inch necessary internal wiring.
Space for mounting of additional MCB In future.
Supply, install, testing and commissioning of Feeder pillar box, outdoor type,as per IS 61349 floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars duly insulated by insulation of RYB colour 400 Amps rating mounted on porcelain insulators .The board shall be double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40X40X6 mm duly embedded in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following:-
INCOMING MCCB 4 pole 100 amps Icu=16KA, Ics =100% of Icu with thermal magnetic release and adjustable overload (min 70% to 100%) -01 no
OUTGOING MCCB TPN 63 Amp 10 KA,C series-02 Nos
MCB SPN 20 Amp C series -02 Nos
Copper bus bar cap 200 amps rating mounting on insulator - 04 Nos
Multifunctional Energy mtr - 1 No for each outgoing and incoming.
RYB LED indicating lamp -01 Set
MS work incl angle iron frame and PCC work
Street light timer suitable for operation of street light with necessary switchgear such as contactor,timer inch necessary internal wiring.
Space for mounting of additional MCB In future.
Supply & Fixing 4 mm dia GI wire chain link fencing and size of mess 100 x 100 mm fixed to any type of post with straining bolts etc inch provn of binding wirecomplete all as specified and directed.
Provision of cable route indicator fabricated from 50/6 mm angle iron of minimum length 450 mm including CI disc of size 100 mm dia duly engraved (in casting ) HT/LT cable duly reveted with angle iron at one end and other end duly grouted in ground with PCC (C 1:3:6) of minimum size 30cm x 20 cm x20 cm. complete all as specified & directed.
M&L for provision of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 2.5 sqmm drawn in and including steel rigid conduit medium grade not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 1.5 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:- (i) Finished sub main wiring with two runs of 2.5 sqmm cable & one run of 1.5 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Boring of hole under road, pavement, hard standing by tranchless technology using ultra sounding technique and nessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed
EXTERNAL WATER SUPPLY Construction of brick masonary valve pit chamber of size 90cmx90cm x90cm (internal dimensions ) including necessary excavation and earth work, PCC work in the foundation and top of the wall, plaster on internal surfacess with CM 1:4 cement mortar, Mild steel cover 3.15 mm thick and angle iron 40mmx40mmx6mm frame , locking arrangements with lock and key /pad lock brass 4 levers with key in duplicate), duly painting the steel surfacess with two coat of synthetic enamel paint over on coat of Red oxide primer complete all as specified shown on drawing and as directed.
Construction of brick masonary valve pit chamber of size 50cmx50cm x50cm (internal dimensions ) including necessary excavation and earth work, PCC work in the foundation and top of the wall, plaster on internal surfacess with CM 1:4 cement mortar, Mild steel cover 3.15 mm thick and angle iron 40mmx40mmx6mm frame , locking arrangements with lock and key /pad lock brass 4 levers with key in duplicate), duly painting the steel surfacess with two coat of synthetic enamel paint over on coat of Red oxide primer complete all as specified shown on drawing and as directed.
Supply and laying of 80 mm bore centrifugally cast (spun) ductile iron pressure pipes for water mains with socket & spigot ends conforming to IS 8329/2000 any length for classification of K7 suitable for rubber gasket joint (push on type) with cement mortar lining inside the pipe with outside zinc coating complete all including existing connection with required size of Tee or MS clamp with rubber bush as specified and directed. Note :Cutting of pipe, fittings for pipe, lead joints shall be measured and paid separately under respective items of Sch 'A'
Discription all as per srl item no 44 above but 100 mm bore complete all specified and directed.
Discription all as per srl item no 44 above but 150 mm bore complete all specified and directed.
S&F LT 415 Volts 4 wire, AC 50 Hz cubical panel factory made confirming to IS-61439, indoor pedestal type feeder piller box double door weather & vermin proof with rain protection canopy front , back, top botton and both side fabricated out of 3.15 mm thick CRCA sheet and partition/supports/fabricated from 1.6mm thick CRCA sheet spray painted two coats inside and outside with appropriate paint over a coat of red oxide primer, necessary locking arrangement two earth terminals, suitable cable glands for all incoming and out going cables including grouting of fidder piller box 60 cm above ground level by providing 90 cm long angle of size 50x50x5mm embedded in PCC 1:2:4 type B-1 using 20mm stone aggrigate up to 30 cm complete all as specified and directed suitable to accommodate and including the following accessories:-
INCOMING MCCB 63 Amps, Icu=16ka, Ics=16ka, 4 Pole - 01 No (Incoming)
OUTGOING MCCB 32 Amps, 10 KA, 3 Pole - 02 Nos
MCB SPN 20 Amp C series -02 Nos
Digital type multifunctional measuring instrument - 01 Nos
DOL starter three phase 440 Volts, 50 Hz complete with MCB, over load relay, under volt/over relay, contactor, capacitor, Voltmeter, On & Off push button complete including fixing arrengment suitable for 5 HP monoblock pump complete all as specified & directed-02 Nos.
Supply and fixing reverse osmosis water purifing equipment wall mounted having capacity 15 Ltrs/Hrs & storage capacity tank 8 Ltrs including 11 Watt UV Lamp power, Filter of mocro sediment, Activated carbon, water Level Incicator, Spin Welded RO Membrane, ABS construction body, filter change alarm, auto start and auto shut, Method of Purification of UF Reverse Osmosis, UV with TDS Controller, Wall Mounted installation. complete all as specified and directed.
Supply and fixing monoblock pumping set 5 HP capacity confirming to IS-12469 : 1988 with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable to operate on 415 Volts 50 HZ AC supply, head range 15-24 Mtr discharge range 850-450 LPM and suction/ discharge pipe 80x65 including PCC foundation as per complany desin complete all as specified and directed.
RAIN WATER HARVESTING MS slotted pipe 152 mm dia of slot size 1.5mm to 3 mm as required bore as in recharge well including threaded cap with air vent pipe complete all as specified and directed.
Bore/Drilling under reaming developing of bore 380 mm dia by mechanical pressure complete all as specified and directed.
PVC well cap for 150 mm dia pipe complete all as specified and directed.
25 mm dia PVC (SWR) bend/Tee heavy duty, fixed and jointed with solvent adhesive etc complete all as specified and directed.
25 mm dia PVC (SWR) bend/Tee heavy duty, fixed and jointed with solvent adhesive etc complete all as specified and directed.
Stone aggregate 10-20 mm graded for filter medium complete all as specified and directed.
PVC pipe 25 mm dia air vent pipe complete all as specified and directed.
S&F cable joint kit for 11 KV (earthed) grade cable for outdoor termination heat shrinkable type with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor of size 95 sqmm connecting and testing complete all as specified and directed.
M/s Khanna Enterprises
GOYALA INFRA PROJECTS PVT LTD.
M/s Jatindra Construction Company
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd.
Pawansut Infra Projects Pvt. Ltd.
M/s Pragmatic Infrastructure Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid