| 1 | L1₹19.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹22.8 L+₹1.8 L (8.53%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹24.3 L+₹3.3 L (15.6%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹24.6 L+₹3.6 L (17.0%)Rejected-Finance MANOBAL 236 VARDMAN NAGAR SHOBAWATO KI DHANI PAL ROAD JODHPUR | L4 | Rejected-Finance Other than Lowest Bidder | |
| 5 | L5₹26.9 L+₹5.9 L (27.9%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
31 Jul 2023, 6:55 pmClosed
CWE Jalandhar Cantt
HQ CWE Nalwa Road Jalandhar Cantt PIN-144005
Please refer tender documents
2023_MES_606712_1
8323/34/E8
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
HQ CWE Jalandhar Cantt
Class D Category b(i) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
AGE (I) Suranussi
₹56,000
Yes
8 Sept 2023
28 Jun 2023
7 Aug 2023
28 Jun 2023
31 Jul 2023
19 Jul 2023
Amount
Dismantling of old unservicable bus bar chamber and Design, supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars (32mm x 5mm) for looping & branch connection system .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The bus bar chamber shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. (Note :- The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 500mm height (without base frame & canopy), 500mm width and 450mm depth).
Supply and fixing MCCB 3 pole 100 Amps rupturing capacity 16 KA, with connecting links on LT panel/feeder pillar including matching with existing with all necessaries arrangement items including dismantling/taking down existing unserviceable MCCB complete all as specified and directed. Make : Havells.
Supply and fixing MCCB 4 pole 160 Amps rupturing capacity 36 KA, with connecting links on LT panel/feeder pillar including matching with existing with all necessaries arrangement items including dismantling/taking down existing unserviceable MCCB complete all as specified and directed. Make : Havells.
Supply and fixing MCCB 4 pole 200 Amps rupturing capacity 36 KA, with connecting links on LT panel/feeder pillar including matching with existing with all necessaries arrangement items including dismantling/taking down existing unserviceable MCCB complete all as specified and directed. Make : Havells..
Supply and fixing MCCB 4 pole 400 Amps rupturing capacity 36 KA with connecting links on LT panel/feeder pillar including matching with existing with all necessaries arrangement items including dismantling/taking down existing unserviceable MCCB complete all as specified and directed. Make : Havells.
Supply and fixing MCCB 4 pole 630 Amps rupturing capacity 50 KA, with connecting links on LT panel/feeder pillar including matching with existing with all necessaries arrangement items including dismantling/taking down existing unserviceable MCCB complete all as specified and directed. Make : Havells.
Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size 200 x 160 x 98 mm , 5 way having terminals for termination of cable with necessary nuts and bolts , including -02 Nos polycarbonate cable gland Make :, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps Make - Legrand in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any type all as directed.
M & L for making earthing pit on existing old earthing where pit is completely damaged including cover 80mm thick pre-cast RCC 1:2:4, type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/sqm in lieu of CI cover, PCC 1:3:6 type C2 pit/chamber including all necessary excavation; and earth work.
M & L for making earthing pit chamber cover on existing old earthing of 80mm thick pre-cast RCC 1:2:4, type B-1 reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/sqm complete all as specified and directed.
Dismantling/ taking down of existing street light switching system and Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is < 30 lux and for switching off > 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall moutaed enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw Three phase load with contactor 25 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 32 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 10sqmm copper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts, complete all as specified and directed by the Engr-in-charge. Make of nature switch - Model No Swadeep-02EC8kw3P of Kakatiya Energy System or equivalent make of Bajaj/Healer, Make for Contactor- BCH/L&T/Schneider, Make of MCBs- Hager/Schneider/L&T/C&S, Enclouser - Sintax or equivalent
Disconnecting, dismantling of existing old unserviceable LT Panel and Design, supply, erection, commissioning and testing of outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 400 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complere and including the followings :- CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges. CABLE ALLEY : Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables, Make of LT Panel : Mc Layer Pvt Ltd, Tricolite, Asian Switchgear, Power System & Control pvt Ltd (PSC)
INCOMING :- MCCB 250 Amps, 4 pole, 415 volts, 35/36 kA, 50 Hz, Ics=Icu=100%, in ground fault Electronic release Micro Processor Make Havells , ABB, Seimens - 01 Nos. OUTGOING : (a) MCCB 100 Amps, 4 pole, 415 volts, 25 KA, 50 Hz, adjestable thermal & fixed magnetic release, Ics = 100%Icu, Make : Havells, Seimens - 04 Nos. (b) MCCB 63 Amps, 4 pole, 415 volts, 27 KA, 50 Hz, thermal magnetic adjestable thermal & fixed magnetic release, Ics = 100%Icu, Make : Havells, ABB, Seimens - 02 Nos. (c) MCCB 40 Amps, 4 pole, 415 volts, 16 KA, 50 Hz, thermal magnetic adjestable thermal & fixed magnetic release, Ics = 100%Icu, Make : Havells, ABB, Seimens - 02 Nos. (d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos. (e) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 Nos. (f) Current transformer (CT) of rating 250/5, tape wound, rated burden 5 VA - 03 Nos. (g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01). (h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos. (j) Copper bus bar 20mm wide,5mm thick, of suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos. (k) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (l) Danger Notice Plate -02 Nos. (m) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles. Of Make - Havells, L&T - 01 Nos (n) Time Astronomical Class + Digital time Switch Cat part No. DHDQB01016 of Havells -01 Nos (o) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 1.80 Sqm front area) ' Make of Panel - BAFNA ELECTRICAL CO JODHPUR/ Universal Switchgear Control/ Power System & Control pvt Ltd (PSC). Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurement of LT panel for approval alongwith CPRI approval. Foundation will prepared as per instructions of manufacturer and rate of fondation shall be deemed to be included in the quoted rates.
Demolition of cement concrete unreinforced in ground floors and paving n.exc 15cm thickness (below or above ground level).
M&L providing precast cement concrete type B1 1:2:4 (using 20 mm graded aggregate) for kerb stone and setting in cement mortar (1:4) complete joints to match as directed by Engr in Charge.
M & L for surface excavation, and spreading of new aggregate of size of 40mm evenly inside the transformer yard area, remove the all debris, hard soil upto a depth of 40 cm manually with causing damage to the LT/HT UG cables of any size and in the presence of UG cable loop carefully clearing the area with out using excavating tools like crowbar, spades, showel etc and depositing the excavated earth to a distance not exceeding 50 m complete all as specified and directed.
S&F change over switch 200 Amps ON load in sheet enclosure four pole to be fixed on wall with FI 32X6mm, nuts, bolts, washers etc. complete with all electric connection complete all as specified and directed. Make : Havells, L & T.
S&F change over switch 320 Amps ON load in sheet enclosure four pole to be fixed on wall with FI 32X6mm, nuts, bolts, washers etc. complete with all electric connection complete all as specified and directed. Make : Havells, L & T
Dismantling of old unserviceable doors, back sheets, side sheet of LT panels, bus bar chamber or feeder pillar box installed at various places by cutting/descrewing after making the system disconnected from Elect supply and M&L for fabrication of doors/frames/ partition, bottom sheet by bending hot or cold, making holes, notching, welding of MS black sheet for LT panel board, bus bar chamber, feeder pillar box made out of 2 mm thick mild steel sheet including providing hinges for opening or closing of door, making handles, locking arrangement and painting of sheet both side with superior quality smoke grey paint after applying a coat of red oxide and matching with the existing complete all as specified and directed by the Engr - in-charge at site. Note : The cost of disconnecting of LT cable and earth strip and reconnecting the same after repair work shall be deemed to be inclussive in the unit quoted rates.
Supply, stringing, streaching and binding in replacement with insulator, ACSR conductor for 6/7 strain (Weasel /ferret/Mink) on HT/LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around conductor etc all as specified & directed.
Stringing only aluminium conductor steel reinforced incl suitable binding wire for connecting the extg OH lines complete all as specified
M & L in repair/replacement for cradle hexagonal , rectangular fabricated with GI wire 4 mm dia on extg OH line in replacement all as specified and directed
M&L for galvanised iron ( GI ) strip 32 X 6 mm complete all as specified. Note : The unit rate includes earth strip in Per RM and work of connected earth point/test point .
M&L for Copper strip 32 X 6 mm complete all as specified. Note : The unit rate includes earth strip in Per RM and work of connected earth point/test point .
M & L for painting of extg panel board of size 1.5 m x 1 m out door type complete ( inner and outer side) (By hand)with two coats of synthetic enemelled paint over a coat of red oxide primer after preparation of surfaces incl scraping of patcy paint surfaces of various location as per site requirement all as specified.
M & L for spreading of stone aggregate of size 40 mm size complete all as directed.
M & L for cable lugs of sizes.
Copper lugs suitable for cable sizes 6 to 16 Sq mm.
Ditto but aluminium lugs for cable sizes 25 to 70 Sqmm.
Ditto but aluminium lugs for cable sizes 95 to 150 Sqmm.
M & L in replacement for contactor ML-4, 3pole, 415 volt 65 Amp coil voltage/ 230 volt complete for street light control including removing of old unserviceable contactor as specified and directed. Make : L & T , Havells
S & F in replacement On-Load Change over Switch 100 Amps complete all as specified and directed by Engr-in-Charge. Make: L&T/ Havells.
9. S & F in repairs cable junction box made of thermoplastic, halogen free, weather proof with metric Knock outs for cable entry including four/five pole terminals and cable entry glands for incomming, out going and connection cable with protection grade IP-66/67 of size 225x295x122 mm and suitable for LT under ground cable any size/capacity including bracing clamp,bolts,nuts & washers. (Make Hensel model No-KF 3500B or equivalent as approved).
Supply and Fixing Cable Jointing Kit for 1100 V grade earthed cable for indoor type termination cold shrinkable joint complete with jointing material, thimble and accessories suitable for XLPE insulated, screened, armoured aluminum conductor cable of size 70 sqm to 120 sqmm 3 core incl opening cable connections/ taking down, taking old unserviceable joint kit and re-fixing cable complete.
Supply and fixing Cable Jointing Kit for 11 00V grade earthed cable for outdoor type end termination cold shrinkable joint complete with jointing material and accessories suitable for XLPE insulated, screened, armoured aluminum conductor cable of size 70 sqmm to 120 Sqmm 3 core incl opening cable connections/ taking down, taking old unserviceable joint kit and re-fixing cable complete.
12. Material and labour for heat shrikable type multishrink brand LT kit for 1100 V XLPE cables of size 70-120 sqmm 3.5/4 core straight through joint complete including taking down old one. (Make : Denson/ Multishrink/ 3M)
S & F copper cable conductor of size 25 sqmm single core for connection of switches,MCCB & capacitor etc including suitable size of copper lugs as require and taking down old cable all as specified and directed. Make : Havells/Finolex
S & F copper cable conductor of size 16 sqmm single core for connection of MCCBs,Bushbar & capacitor etc including suitable size of copper lugs as require and taking down old cable all as specified and directed. Make: Havells/Finolex
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
M&L for earthing complete with galvanised steel earth plate electrode 600X600X6mm thick burried directly in ground (Earth pit not less than 2.25 mtr deep below the ground level with top edge of earth plate not less than 1.5 mtr below normal ground level) connected to galvanised earth wire 4mm dia as earthing lead by means of bolts, nuts, chuck nuts and washers of GI or steel all as shown in electrical plate No 3 of SSR-2009 (Part-I) including charcoal dust common salt, 20mm bore GI medium grade watering pipe funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth lead including PCC pit 1:2:4 type B-1 using 20mm graded stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm steel bars 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engr in charge and testing for required value complete. Note: If earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost.
DUGGAL CONSTRUCTION CO
GULSHAN SINGH GHAI AND SON
AMAN ASSOCIATES
PAWAN KUMAR GOVT. CONTRACTORS
Northern cable fault locatoers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .