Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC | ₹2.3 Cr Quoted ₹2.0 Cr | L1 | Accepted-AOC OK |
| 2 | L2₹2.5 Cr+₹51.9 L (26.2%)Rejected-AOC 184 NEAR GOODWAY TAILORS PRITHVIPURA RASAL ROAD BRIDGE JODHPUR RAJASTHAN 342006 | JODHPUR | RAJASTHAN | 342006 | ₹2.5 Cr+₹51.9 L (26.2%) | L2 | Rejected-AOC NOT OK |
| 3 | L3₹2.5 Cr+₹53.5 L (27.0%)Rejected-AOC UNIT NO 12 4 MERLIN ACROPOLIS 12TH FLOOR 1858 1 RAJDANGA MAIN ROAD KOLKATA 700107 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700107 | ₹2.5 Cr+₹53.5 L (27.0%) | L3 | Rejected-AOC NOT OK |
| 4 | Rejected-Technical RNB ROAD KOKRAJHAR ASSAM | KOKRAJHAR | ASSAM | 783331 | - | - | Rejected-Technical Non Responsive |
Tender Value
₹2.5 Cr
EMD Value
₹5 L
Closing Date
20 Feb 2024, 10:00 amClosed
Chief General Manager(PPD)
BIJULEE BHAWAN (FIRST FLOOR) PALTANBAZAR GUWAHATI - 781001
Turnkey Construction of a 132kV Line Bay for supply of power to Dalmia Cement (Northeast)Limited, Umrangso at 132kV Umrangso GSS, AEGCL
2024_AEGCL_35563_1
AEGCL/Tech-1099/Umrangso/BID
Open Tender
Electrical Works
Works
270 days
Umrangso
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
₹5 L
7 Aug 2024
20 Jan 2024
22 Feb 2024
20 Jan 2024
20 Feb 2024
20 Jan 2024
Amount
Circuit Breakers with mounting structures and terminal connectors etc.as applicable as per specification
145 kV, 3150 A, 31.5 KA for 3 sec outdoor SF6 Breakers
Control & Relay Panel with Automation (Simplex Type) complete with BCU, ethernet switch and all accessories as required for SAS integration.
For 132 kV Feeder Capable of integration into Existing SAS (ERL) at Umrangsu GSS
Current Transformers (1-phase) with terminal connectors etc. as per specification
132 kV, 400-200/1-1-1 Line CT
Isolators with insulators, terminal connectors, structures complete etc. as per specification
132 kV horizontal centre break isolator With Single Earth Switch (3-phase)
132 kV horizontal centre break isolator Without Earth Switch (3-Phase)
132 kV horizontal centre break isolator Without Earth Switch (3-Phase)(Tandem type)
Lightning Arrester with terminal connectors etc. as per specification
132 kV Lightning Arrester
Post Insulator with terminal connectors etc. as per specification
132 kV Post Insulator
132 kV CVT with terminal connectors etc as per specfication.
Supply of Mounting structures with mounting & foundation bolts as per drawings supplied for
132 kV Line CT
132kV Isolator With Single Earth Switch
132kV Isolator Without Earth Switch
132kV Isolator Without Earth Switch (Tandem Type)
132kV Lightning Arrester
132kV Post Insulator
132kV CVT
Supply of Power Cables
Supply of Control Cables
Supply of ACSR Panther Conductor
Disc Insulator Strings complete with all hardware fittings, clamps etc.
10 Disc Tension Insulator String for single panther
10 Disc Tension Insulator String for twin Panther
9 Disc Suspension Insulator String for single panther
9 Disc Suspension Insulator String for twin panther
Spacer for panther
Supply of Earthing System Materials
65x12 GI flat for risers, equipment earthing, column earthing etc.
50x6 GI flat Earthing conductor for earthing of indoor L.T & control panels, Junction box, Marshalling boxes, cable trenches etc.
40 mm Dia. 3mtr long M.S. rod earth electrode (driven) with test link for each tower with earth peak, LAs & CVTs.
Supply of Bay Marshalling Kiosk along with mounting structure
Clamps and Connectors
Breaker Clamp with connectors and all hardware fittings suitable for ACSR Panther conductor
CT Clamp with connectors and all hardware fittings suitable for ACSR Panther conductor
Tee connector rigid through type alongwilh all hardware fittings For 132kV LA and suitable for ACSR Panther conductor
Tee connector rigid through type alongwith all hardware fittings for 132kV CVT and suitable for ACSR Panther conductor
T clamp suitable for twin clamp ACSR panther conductor alongwith all hardware fittings
PG Clamp with connectors and all hardware fittings suitable for ACSR Panther conductor
Isolator Pad Clamp with all hardware fittings suitable for ACSR Panther conductor
Post insulator Clamp with all hardware fittings suitable for ACSR Panther conductor
T- Clamp twin Panther to Single Panther Conductor aiongwith all hardware fittings
Suspension Clamp with connectors and all hardware fittings suitable for ACSR Panther conductor
Supply of 110 V Battery bank, Charger, DC DB & 415 V ACDB
Supply of 110 V VRLA Battery bank with battery stand and all other fittings and accessories as per specification
Supply of 110 V Battery charger with all fittings and accessories as per specification
Supply of 110 V DCDB
Supply of 415 V ACDB
Supply and Design of Bay Steel Structures except equipment mounting structures
Column
Column Type 'C1A' ( 2 Nos.) [ 3748.84 Kg/ per Column ]
Column Type 'C2' (4 Nos.) [ 1022.96 Kg/ per Column ]
Beams
Beam Type 'B1' ( 1 Nos) [ 867.89 Kg/ per Column ]
Beam Type 'B2' ( 2 Nos) [ 867.89 Kg/ per Column ]
Supply of ABT meter with cubicle as per specification (SAMAST Complaince)
Supply of Fire Fighting Equipments
25kg capacity FE DCP type, trolley mounted
FE CO2 6.5KG capacity, wall mounted
Foam type 9 Ltr capacity, wall mounted
Mandatory Spares
For 132 KV Circuit Breakers
Interrupter
Tripping Coil
Closing coil
SF6gas filled cyliner-12 Kq
For Control & Relay panels
Over current relay
Earth fault relay
Distance protection Relay
Master Trip Relay
Others
132 KV Lightning Arrester
132kV Isolator moving and fixed contact
132 KV, 400-200/1-14 single phase Line CT
Terminal connectors for 132 KV CT
Terminal connectors for 132 KV isolator
Description of Work / Item(s)
Amount
Circuit Breakers with mounting structures and terminal connectors etc.as applicable as per specification
145 kV, 3150 A, 31.5 KA for 3 sec outdoor SF6 Breakers
Control & Relay Panel with Automation (Simplex Type) complete with BCU, ethernet switch and all accessories as required for SAS integration.
For 132 kV Feeder Capable of integration into Existing SAS (ERL) at Umrangsu GSS
Current Transformers (1-phase) with terminal connectors etc. as per specification
132 kV, 400-200/1-1-1 Line CT
Isolators with insulators, terminal connectors, structures complete etc. as per specification
132 kV horizontal centre break isolator With Single Earth Switch (3-phase)
132 kV horizontal centre break isolator Without Earth Switch (3-Phase)
132 kV horizontal centre break isolator Without Earth Switch (3-Phase)(Tandem type)
Lightning Arrester with terminal connectors etc. as per specification
132 kV Lightning Arrester
Post Insulator with terminal connectors etc. as per specification
132 kV Post Insulator
132 kV CVT with terminal connectors etc as per specfication.
Supply of Mounting structures with mounting & foundation bolts as per drawings supplied for
132 kV Line CT
132kV Isolator With Single Earth Switch
132kV Isolator Without Earth Switch
132kV Isolator Without Earth Switch (Tandem Type)
132kV Lightning Arrester
132kV Post Insulator
132kV CVT
Supply of Power Cables
Supply of Control Cables
Supply of ACSR Panther Conductor
Disc Insulator Strings complete with all hardware fittings, clamps etc.
10 Disc Tension Insulator String for single panther
10 Disc Tension Insulator String for twin Panther
9 Disc Suspension Insulator String for single panther
9 Disc Suspension Insulator String for twin panther
Spacer for panther
Supply of Earthing System Materials
65x12 GI flat for risers, equipment earthing, column earthing etc.
50x6 GI flat Earthing conductor for earthing of indoor L.T & control panels, Junction box, Marshalling boxes, cable trenches etc.
40 mm Dia. 3mtr long M.S. rod earth electrode (driven) with test link for each tower with earth peak, LAs & CVTs.
Supply of Bay Marshalling Kiosk along with mounting structure
Clamps and Connectors
Breaker Clamp with connectors and all hardware fittings suitable for ACSR Panther conductor
CT Clamp with connectors and all hardware fittings suitable for ACSR Panther conductor
Tee connector rigid through type alongwilh all hardware fittings For 132kV LA and suitable for ACSR Panther conductor
Tee connector rigid through type alongwith all hardware fittings for 132kV CVT and suitable for ACSR Panther conductor
T clamp suitable for twin clamp ACSR panther conductor alongwith all hardware fittings
PG Clamp with connectors and all hardware fittings suitable for ACSR Panther conductor
Isolator Pad Clamp with all hardware fittings suitable for ACSR Panther conductor
Post insulator Clamp with all hardware fittings suitable for ACSR Panther conductor
T- Clamp twin Panther to Single Panther Conductor aiongwith all hardware fittings
Suspension Clamp with connectors and all hardware fittings suitable for ACSR Panther conductor
Supply of 110 V Battery bank, Charger, DC DB & 415 V ACDB
Supply of 110 V VRLA Battery bank with battery stand and all other fittings and accessories as per specification
Supply of 110 V Battery charger with all fittings and accessories as per specification
Supply of 110 V DCDB
Supply of 415 V ACDB
Supply and Design of Bay Steel Structures except equipment mounting structures
Column
Column Type 'C1A' ( 2 Nos.) [ 3748.84 Kg/ per Column ]
Column Type 'C2' (4 Nos.) [ 1022.96 Kg/ per Column ]
Beams
Beam Type 'B1' ( 1 Nos) [ 867.89 Kg/ per Column ]
Beam Type 'B2' ( 2 Nos) [ 867.89 Kg/ per Column ]
Supply of ABT meter with cubicle as per specification (SAMAST Complaince)
Supply of Fire Fighting Equipments
25kg capacity FE DCP type, trolley mounted
FE CO2 6.5KG capacity, wall mounted
Foam type 9 Ltr capacity, wall mounted
Mandatory Spares
For 132 KV Circuit Breakers
Interrupter
Tripping Coil
Closing coil
SF6gas filled cyliner-12 Kq
For Control & Relay panels
Over current relay
Earth fault relay
Distance protection Relay
Master Trip Relay
Others
132 KV Lightning Arrester
132kV Isolator moving and fixed contact
132 KV, 400-200/1-14 single phase Line CT
Terminal connectors for 132 KV CT
Terminal connectors for 132 KV isolator
Description of Work / Item(s)
Amount
Erection, testing & commissioning of Circuit Breakers including laying & terminating of LT power and control cables as required
132 kV Gang operated SF6 Breakers
Erection, testing & commissioning of Control & Relay Panels including laying & terminating of LT power and control cables as required
For 132 kV Feeder compatible with existing SAS (ERL) at Umrangso GSS
Erection, testing & commissioning of Current transformers including laying & terminating of control cables as required
132 kV, 400-200/1-1-1 Line CT
Erection, testing & commissioning of Isolators including laying & terminating of LT power and control cables as required
132 kV With Single Earth Switch
132 kV Without Earth Switch
132 kV Without Earth Switch (Tandem Type)
Erection, testing & commissioning of Lightning Arrester including including laying & terminating of control cables as required
132 kV Lightning Arrester
Erection, testing & commissioning of Post Insulator including including laying & terminating of control cables as required
132 kV Post Insulator
Erection, testing & commissioning of CVT including including laying & terminating of control cables as required
132kV CVT
Erection of Mounting structures for different terminal equipments as required for
132 kV, 400-200/1-1-1 Line CT
132kV Isolator With Single Earth Switch
132kV Isolator Without Earth Switch
132kV Isolator Without Earth Switch (Tandem Type)
132kV Lightning Arrester
132kV Post Insulator
132kV CVT
Erection testing and Commissioning of 110 V Battery bank, Charger, DC DB & 415 V ACDB
Supply of 110 V VRLA Battery bank with battery stand and all other fittings and accessories as per specification
Supply of 110 V Battery charger with all fittings and accessories as per specification
Supply of 110 V DCDB
Supply of 415 V ACDB
Erection of Switchyard Lattice Steel Columns and Beams
Column Type 'C1A' ( 2 Nos.) [ 3748.84 Kg/ per Column ]
Column Type 'C2' (4 Nos.) [ 1022.96 Kg/ per Column ]
Beam Type 'B1' ( 1 Nos) [ 867.89 Kg/ per Column ]
Beam Type 'B2' ( 2 Nos) [ 867.89 Kg/ per Column ]
Integration of Control Relay Panel into the existing Substation Automation System (SAS) at 132kV Dullavcherra GSS.
Hoisting of Insulator strings, Stringing of Conductors, GI shield wire etc including supply of disc insulator strings, clamps, GI stranded shield wire, connectors etc. As required for whole scope of works
Installation of earthing system with GI flats, electrodes etc. For present scope of area
Illumination
Design, supply and installation of outdoor illumination system for the 132 KV Bay Area (Consisting of minimum 6 nos of Led lamps with fittings etc) including supply of all materials
Erection of Bay Marshalling Kiosk as per drawings and specifications including construction of foundation inclusive of supply of all foundation Materials and Labour as directed.
Erection, testing and Commissssioning of ABT Meter as per specification
Dismantling of existing structures including foundation.
ET&C of Fire Fighting Equipments
25kg capacity FE DCP type, trolley mounted
FE CO2 6.5KG capacity, wall mounted
Foam type 9 Ltr capacity, wall mounted
Description of Work / Item(s)
Amount
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Circuit Breaker (1 Set)
Excavation
Filling
Brick Soiling
Formwork
Reinforcement
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Current Transformer ( 3 Nos.)
Excavation
Filling
Brick Soiling
Formwork
Reinforcement
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV CVT (3 Nos.)
Excavation
Filling
Brick Soiling
Formwork
Reinforcement
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Isolators With/ Without Earth Switch/Tandem ( 3 Sets)
Excavation
Filling
Brick Soiling
Formwork
Reinforcement
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Lightning Arresters( 3 Nos)
Excavation
Filling
Brick Soiling
Formwork
Reinforcement
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Post Insulator
Excavation
Filling
Brick Soiling
Formwork
Reinforcement
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for Lattice Steel Column ( Column Type (C2), 4Nos.)
Excavation
Filling
Brick Soiling
Formwork
Reinforcement
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for Lattice Steel Column ( Column Type (C1), 2Nos.)
Excavation
Filling
Brick Soiling
Formwork
Reinforcement
Description of Work / Item(s)
Amount
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 graded stone aggregate upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well including getting out and disposal of excavated earth lead upto 50 m as directed by Engineer-incharge
Filling with available sand and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-111) derived from natural sources : 6 graded stone aggregate 20min nominal size derived from natural sources)
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Supplying fitting and fixing chain link fencing of 10 S.W.G, G.I Wire 50mm x 50mm mesh fitted into MS Angle iron post at 2500nun apart , including supplying , fitting and fixing hooks, eye bolt with nuts, staples and bols including three horizontal lines of GI wire including painting to M.S angle post and wire in PCC base etc
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.0 (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specifiedi). 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm,
Pipes, Bends, Junction tees etc. Price 6kg/sqm (im length) and 110 mm dia . PCC (00 in) & weep holes (150 m)
Providing 100mm thick gravelling of switchyard as per speification & drawings inluding supply of all materials
Site preparation & necessary cleaning for consturction for approach road
Construction of sub grade and earthen shoulders with approved material obtained from borrow pits with all lift and leads transporting to site, speading, grading to required slope and compacted to meet requirement of table 300.2 with lead upto 1000 m as pe technical specification clause 303.1 i) private land 200 mm thick
Granular Sub Base with well graded material: A) Bs Mix in place method Construction of granular sub base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator t OMC , and compacting with smooth wheel roller to achieve the desired density, compaction as per technical specification clause 401 A) for grading I materials
Water Bound Macadam Sub-base/base: 1) WBM grading 1 Using stone screening type-A 13.2 mm for Gr. I Providing, laying, spreading and compacting stone aggregates of specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and chamber , applying nad brooming, stone screeiting/ binding materials to fillup the interstices of coarse aggregate, watering and compacting to the required density grading 1 as per technical specification clause 404 A) By manual means
Prime Coat: i) Providing and applying Primer coat with bitumenous emulsion (SS 1) on the prepared surface of granular base in
Tack Coat : iii) Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
Bituminous Macaddam: i) Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per table 500.4 premixed with bitumious binder, transported to site upto a lead od 1000 m laid over a previously prepared surface with paver finisher to to required grade, level and alignment and rolled to achieve the desired compaction as per Technical specification Clause 504.
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using type A, type B and type C as per technical specification clause 510 A Manual means Case I Type A 1 Bitumen (S -90)
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface: Providing and laying of hot applied thermoplastic compound 2.5 aim thick including reflectorising glass beads (4. 250 gins per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per 1RC:35 The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications
HI-TECH CORPORATION
Lumino Industries Limited
Lumino Industries Limited
HI-TECH CORPORATION
Lumino Industries Limited
HI-TECH CORPORATION
Lumino Industries Limited
HI-TECH CORPORATION
Lumino Industries Limited
HI-TECH CORPORATION
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .