Loading…
Loading…
Tender Value
₹3.7 Cr
EMD Value
₹1.9 L
Closing Date
13 Jul 2026, 5:30 pm
Similar tender results from the same govt authority in the past 3 years.
RAMBABU DINKAR
GWALIOR MUNICIPAL CORPORATION
SMART LOAD MANAGEMENT OF 2 x 1250 kVA with Electrical infrastructure with Wireless and SCADA Automation Online Monitoring WEIGH BRIDGE AUTOMATION FOR DATA UPDATING AND ONLINE MONITORING File No- 74/26x6/4.
2026_UAD_515148_1
MPGMC/74/26x6/4/VIDUt/2026-27
Open Tender
Miscellaneous Works
60 days
ELECTRICITY DEPARTMENT
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹1.9 L
11 Jun 2026
11 Jun 2026
15 Jul 2026
12 Jun 2026
13 Jul 2026
29 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Supply of support for overhead line RS joist of I.S. standard including drilling of required hole etc. complete as required.
H - Beam 152x152mm, Std weight 37.1 Kg/Mtr | - | Metre | - | - | BI01010001010000000000000515BI0100001113 |
| 2 | Erection of RS Joist pole/'H' beam/steel tubular/steel rail pole of length 10 metres but not exceeding 15 metres in cement concrete 1:3:6 (1 cement : 3 core sand: 6 graded stone aggregate 40mm nominal size) base, foundation, muffing including excavation and back refilling etc. as required. | - | Each | - | - | BI01010001010000000000000515BI0100001113 |
| 3 | Supply, fabrication and erection of ngle/channel/flat iron fitting for overhead line & sub-station etc such as 'D' bracket, cross arms, top clamp, 'V' cross arms, back/support clamp or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of aluminium paint as required as per specification. | - | KG | - | - | BI01010001010000000000000515BI0100001113 |
| 4 | Supply, laying and fixing of G.I. earth coil of 4mm dia G.I. wire having 120 turns of nearly 50mm dia. and 3 mt. long tail in existing pit duly earthed with pole etc complete as required as per specification. | - | Each | - | - | BI01010001010000000000000515BI0100001113 |
| 5 | Supplying, installing, testing and commissioning of 33/0.4 KV 3 Phase 50 cycle oil immersed, naturally cooled, outdoor type transformer connected delta on H.T. side and star on L.T. side, hand operated off load Tap changer switch, rating and diagram plate, two earthing terminal, lifting lugs, oil level gauge, drain valve with plug, temperature not exceeding 50ºC on load, temperature dial gauge, Bucholz relay, oil conservator with drain plug, oil filling hole with plug, dehydrating silica gel breather on eye level, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on H.V. side and cable box on LV side, first filling of oil upto desired level and transformer installing on existing structure with all required materials arrangement as required ISI marked & as per IS specification. Energy efficiency level -3 (New level-2) Copper wound 1250 KVA | 0.49 | Each | - | - | BI01010001010000000000000515BI0100001113 |
| 6 | Supply & fixing fencing of chain link mesh 100 x 100 mm, 12 SWG GI wire for for D.P. structure electric substation switch yard including single post of angle iron size 50x50x5mm, 2.5 mt long should be provided upto 2.00 mt. apart or as required. The panel frame with required angle iron/ flat iron members/cross members including mesh welded in frame panel shall be erectedbetween the posts. The angle iron post shall be erectedin cement concrete M-15 (1:2:4) (20 mm graded metal) foundation, including excavation of pit and refilling thesame. The fencing shall be provided with one entrancegate including locking arrangement as required as per specification. The height of fencing shall be 2 mt. above ground level. Fencing shall be painted with required shade. | - | sq Mtr | - | - | BI01010001010000000000000515BI0100001113 |
| 7 | Designing and construction of pedestal (plinth) fortransformer of desired size including excavation in hard rock/soft rock, base concrete M-7.5 (1:4:8), 20mm metal and pedestal of RCC M-15 (1:2:4) including required tar steel reinforcement for required height as per IE rules from base concrete including shuttering and finishing with 10mm thick plaster in cement mortar 1:3 curing & white washing etc. complete as per specifications. | - | Cu.Mt | - | - | BI01010001010000000000000515BI0100001113 |
| 8 | Collection and spreading of metal dust, murum and 40mm graded hard metal in sub-station yard or as
required as mentioned below
Metal dust | - | Cu.Mt | - | - | BI01010001010000000000000515BI0100001113 |
| 9 | Collection and spreading of metal dust, murum and 40mm graded hard metal in sub-station yard or as
required as mentioned below
Metal 40 mm | - | Cu.Mt | - | - | BI01010001010000000000000515BI0100001113 |
| 10 | Supplying and drawing all aluminium alloy conductor (AAAC) of approved make conforming to IS 398-1979 Pt. IV, including binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required including clearing of obstacles (if any)
AAAC 0.2 sq inch (232 sq.mm Al. EQ.)- (Panther) | 0.29 | Km. | - | - | BI01010001010000000000000515BI0100001113 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.55 MB
KedarpurRFP.pdf
Tender Documents • 0.76 MB
BOQ_620485.xls
BOQ • 0.32 MB
Estimet74.pdf
Additional Documents • 6.58 MB
Annexures.pdf
Additional Documents • 0.05 MB
Download all tender documents and submit your bid