| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.8 LAccepted-AOC | ₹47.8 L Quoted ₹48.0 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹49.6 L+₹1.6 L (3.34%)Rejected-Finance KTA ROAD LAMBA LINE JUNGLIGHAT PO PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹49.6 L+₹1.6 L (3.34%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹50.5 L+₹2.5 L (5.18%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹50.5 L+₹2.5 L (5.18%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹51.4 L+₹3.4 L (7.12%)Rejected-Finance | ₹51.4 L+₹3.4 L (7.12%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹52.5 L+₹4.5 L (9.36%)Rejected-Finance MES WORKS SITE CARNICOBAR ANDAMAN NICOBAR ISLAND PIN 744301 | CARNICOBAR | NICOBAR | ANDAMAN AND NICOBAR ISLANDS | 744301 | ₹52.5 L+₹4.5 L (9.36%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹48.4 L
EMD Value
₹97,000
Closing Date
26 Sept 2022, 6:00 pmClosed
Garrison Engineer Haddo Port Blair
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
PROVN OF OFFICE AND STORAGE SPACE FOR SPB, TWO WHEELER PARKING INSIDE NSRY AND SERVER ROOMS FOR IUHDSS AT NSRY WHARF UNDER GE HADDO, PORT BLAIR
2022_MES_550639_1
8676/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
Class D Category a (i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹97,000
Yes
21 Oct 2022
7 Sept 2022
3 Oct 2022
7 Sept 2022
26 Sept 2022
21 Sept 2022
9 Sept 2022 - 14 Sept 2022
Amount
Excavation in post holes(or similar holes) each n. exc 0.5 Cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers n. exc 25 cm watering and removing surplus soil to a distance n exc 50 m and making good surface as in hard/dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation etc., or for shafts, wells, cess pits, manholes, pier holes etc not exc. 10 Sqm on plan and getting out in hard/dense soil complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for Cement concrete P.C.C (1:4:8) Type D2 (using 40 mm graded aggregate) as in sub base 100 mm thk complete all as specified.
S&F for glossy finished chequered cement concrete tiles 30cmx30cmx25mm thick set jointed with grey cement and pigment and pointed in neat cement slurry including 15 mm thick screed bed of CM(1:6) in floors complete all as specified and directed.
M&L for PCC type D2 (1:4:8) (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for PCC type C2 (1:3:6) (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
S&F for joist, channel,angle,or tee sections, fixed independently, without connecting plates,etc (cut to ordinary length i.e., with in 20 mm of the length indicated conforming to Fe 410 -W-(Gde-E-250) Quality- A complete all as specified and as directed
S & F rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates Fe 410-w(Gde-E-250 ) quality A complete all as specified and as directed.
S & F for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde E-250) Quality -A complete all as specified and as directed.
S&F for pre painted Galvalume aluminium zinc coating GI based corrugated / trapezoidal section of steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa (AZ 150) as in roof covering fixed with self tapping screws complete all as specified and as directed.
S&F for pre painted Galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa (AZ 150) as in roof covering fixed with self tapping screws complete all as specified and as directed.
M&L for aluminium wind tie of any size fixed with self tapping screws with integral EPDM washer in roof covering complete all as specified and as directed.
M&L for preparation of new steel surfaces over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 8 to 10 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, for work on vertical surfaces such as skirting, dados and risers to steps etc., including 10mm thick backing coat in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Demolition of cement concrete (un reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for design mix reinforced cement concrete M-30 grade (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc., basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for design mix reinforced cement concrete M-30 grade (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for design mix reinforced cement concrete M-30 grade (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for design mix reinforced cement concrete M-30 grade (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, cooking platforms and in shelves and the like complete all as specified and as directed.
M & L for design mix reinforced cement concrete M-30 ( Using 20 mm graded stone aggregate) as in Chajjas complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for 100mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in floorings and pavings finishing concrete surfaces even & smooth using extra cement including making impression of expanded metal while concrete is green complete all as specified and as directed.
M&L for 4mm thick epoxy floor with Anti static grid with copper strip 40mm x 0.5mm thick 1mtr grid intervals and connected to earth pit etc complete all as specified and directed as Engg-in-Charge.
M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to sides of sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to chajjas, chullah hoods, troughs and similar items including edges for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
M & L for hardcore of gauge exc 63 mm but n.exc 100mm deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface of broken stone or boulders complete all as specified and directed,
M&L for rendering 15mm thick in two coats 5mm thick in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement over 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete surfaces of walls finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L for rendering 5mm thick in CM (1:3) on fair faces of brick work or concrete surfaces in ceiling finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L for preparation of newly plastered wall surfaces, & applying with 3mm average thick wall care putty and applying two coat of oil bound distemper over one coat of primer including leveling the surface which undulation found with cement putty etc complete all as specified and directed.
Material & Labour for preparing newly plastered wall surface and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
M&L for preparation on newly plastered external wall surface and applying two coat of weather proof (exterior grade) acrylic emulsion paint with anti fungal property over a coat of primer of the same manufacturer as that of paint complete all as specified and as directed. (Make: Dulux Weather Shield Max or Apex Ultima from Asian Paints or Berger weather coat All guard) complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling surface, & applying with 3mm average thick wall care putty and applying two coats of distemper oil emulsion over a coat of primer including levelling the surface complete all as specified and as directed.
M&L for powder coated anodised aluminium partition, window and door/ventilator with frame and shutters and grill fully or partly glazed, sliding/openable/fixed fully glazed and panels fixed with panels inserts 12 mm thick pre-laminated particle board/sheet glass including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts etc. The size of aluminium section shall be all as specified in relevant IS Code and SSR Part-I complete all as specified and as directed. NOTES: (i) Supply only floor spring, glass, Imax hinges, SS friction hinges, particle board, aluminium fly proof mesh will be measured and paid separately under relevant items of this BOQ. (ii) Weight of aluminium section only shall be accounted for the purpose of payment. However unit rate quoted shall be deemed to include for cost of rubber beading, neoprene packing, fittings such as handles, butt hinges, tower bolts, rollers for sliding windows, locking arrangement and fixing only of panel inserts of glass/ particle board/aluminium fly proof mesh etc. (iii) Weight of aluminium handle, butt hinges, tower bolts shall not be accounted for payment purpose.
Supply only plain sheet glass, 4.0mm thick ordinary quality and glazing with aluminium glazing clips in square not exceeding 0.5 Sqm in each pane in aluminium window shutter complete all as specified and as directed.
SUPPLY ONLY 5.5 mm thick sheet glass, ordinary quality and glazing with aluminium glazing clips in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only aluminium expanded metal fly proof mesh, cut to required size and shape, with 0.45mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.
S&F 12mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side with balancing white lamination complete all as specified and as directed.
S&F powder coated aluminium grill of approved pattern, anodised powder coated, cut to required size and shape, fixed in position with aluminium beading & frame made of aluminium F-section fixed to aluminium windows/ventilators complete all as specified and as directed.
M&L for seamless gypsum board false ceiling 12 mm thick including for any sunk or raised moulding with 25mm long self drilling/tapping screws having Philips head with joining compound and 48 mm wide fibre tape to provide seam less finish and including GI frame work of seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flange of 20mm and 30 mm, web of 27 mm, fixed to surrounding wall using nylon sleeves and screws at 450 mm c/c / intermediate channel 0.9 mm thick having two equal flanges of 15 mm suspended from soffit at approx 900 mm c/c with GI cleats and steel expansion fasteners with and including ceiling section (not exceeding 1.2 m length) of 0.55 mm thick having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting across the intermediate channel at 457 mm c/c including hangers 6 mm dia GI adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size, 60 mm long & expansion hold fasteners 12.5 mm dia, 40 mm long and finally applying two coats of oil bound distemper with roller finish over a coat of primer complete all as specified and as directed.
S&F venetian blinds for windows/doors, vertically hanged from powder coated steel track with hand drawn control mechanism, thread interconnected, solid pattern, including fixtures and fittings with 90° rotation of blinds to allow light to pass or to fold up on one side of a window/door complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints, laid in trenches/fixed to walls/placed in weep holes using synthetic rubber adhesive cement solvent complete all as specified and as directed.
S&F PVC (SWR) bends any radius, diameter of outlet 110 mm complete all as specified and as directed.
S&F PVC (SWR) bends with oval access door, any radius, diameter of outlet 110 mm complete all as specified and as directed.
M&L for screed bed 10mm thick in CM (1:4) on RCC roof slab, surfaces finished even and smooth without using extra cement duly mixed with water proofing compound @ 3% by weight of cement complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
M&L for preparing plastered surfaces and applying a coat of cold applied bituminous primer over cleaned roof/ sunken surface @ 0.30 Kg/sqm and applying one coat of hot blown bitumen 85/25 grade @ 1.2 Kg/Sqm over primer followed by 3 mm thick APP modified 5-layered polymeric water proofing membrane weighing not less than 3.0 Kg/sqm reinforced with polyester non-woven fabric weighing not less than 150 grams/sqm laid as per the manufacturer instructions with side over lap of 100mm & end over lap of 150mm & tucked into the chases on roof, sunken slabs, edges and vertical surfaces complete all as specified and directed. MAKE: STP Limited/ PIDILITE INDUSTRIES LIMITED (Dr. FIXIT TORCHSHIELD P3160)/ IWL INDIA LTD
M&L for applying a coat of bituminous aluminium paint @ 0.15 Kg/sqm over bituminous surface complete all as specified and directed. MAKE: STP Limited/ PIDILITE INDUSTRIES LIMITED/ IWL INDIA LTD
Supply only integral water proofing compound.
M&L for anodised aluminium snap grid frame work for false ceiling with size of grid 605mm x 605mm all as specified in SSR Part-I 2009, hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat iron 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including cutting, drilling, jointing etc., 4mm thick non-asbestos fibre cement building design boards fixed or laid/ inserted to aluminium frame work with screws and including preparation of surfaces with two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
Demolition of reinforced cement concrete in any position, not exc 15cm thick above & below ground level complete all as specified and as directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 3mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for Make of wire : Polycab / Gloster / Anchor / Havells / Finolex / Anchor Make of PVC Casing & Caping : Modi / Precision / Supreme / Finolex / Polycab
ONE LIGHT/FAN point controlled by one, one way 6 Amps modular switch.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on independent board.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on same board.
M&L for Point wiring complete with two 4.0 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps modular switch on independent board. Make of wire : Polycab / Gloster / Anchor / Havells / Finolex / Anchor Make of PVC Casing & Caping : Modi / Precision / Supreme / Finolex / Polycab
S&F switch piano, flush type, single pole, one way, 6 Amps, 240 volts complete all as specified and as directed. Make : Anchor / Cona / Legrand
S&F switch piano, flush type, single pole, one way, 15/16 Amps, 240 volts complete all as specified and as directed. Make : Anchor / Cona / Legrand
S&F switch socket outlet, 2-in-1, 3 pin, 6A, flush type, multipurpose, 240 volts complete all as specified and as directed. Make : Anchor / Cona / Legrand
S&F switch socket outlet, 2-in-1, 3 pin, 15/16A, flush type, multipurpose, 240 volts complete all as specified and as directed. Make : Anchor / Cona / Legrand
M&L for ceiling rose, three terminal, 65x20mm size, PVC/Polycarbonate, insulated body, 6A, 240 volts complete all as specified and as directed.
S&F Tube light fittings LED 20 watts 4 feet including all accessories and fixing arrangements complete all as specified and directed Make :CG Cat Part No : CCS-100-20-65-HL2-DP-NWH/ Philips Cat Part No : Astra line plus/C&S/Havells
S&F ceiling fan of 1200mm sweep 5 star, suitable for AC 220 volts, 50 Hz and including all electric connection from ceiling rose to ceiling fan complete all as specified and as directed. MAKE: CG Model No.: Briz Air Deco / Havells/ Usha/ Orient
S&F SPN DB sheet metal enclosure double door suitable (IP-43) Protection 4 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete. Make : Havells/L&T/Indo Asian/Legrand/Schneider
S&F MCB, DP, "C" series, 240 volts, 40 Amps, 10 KA rupturing capacity complete all as specified and as directed. Make : Indo Asian Cat Part No. 811154 / Havells/L&T/Legrand/Schneider
S&F MCB, SP, "C" series, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811122 to 811129 or equivalent in L&T/ LEGRAND/ HAVELLS
S&F new GI brackets of GI pipe light grade of size 25mm dia including nuts, bolts and washers for building security light complete all as specified and directed.
S&F 25 watts LED building security light fittings IR 65 luminaire. Pressure die cast aluminium housing powder coated graphite grey and toughened glass of IP 65 including necessary fixing arrangements as per site requirements complete all as specified and directed. Make : C&S Model No. LTESSE25WLED/ Philips Model No. BRP020LEDHP/CW240V25/ CG Cat No - LSTO-25-CDL/ Havells/ Luker Cat Part No : LOHY210 WH
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 2 core, 10 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed. Note: (i) Necessary test results like continuity test, megger tests shall be submitted to Engg-in-Charge before the cable is laid. (ii)Excavation earth work will be measured and paid separately Make : Gloster / Havells / Anchor / Polycab / Finolex.
M&L for HDPE DWC (Double wall corrugated) pipe of size 40mm (Outer diameter) x 32mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed. Make : REX POLYEXTRUSION LTD or its equivalent as approved
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
M&L for Sub main wiring complete with two runs (1P+1N) of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 2.50 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 4.0 Sqm copper conductor, One run of 2.50 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
Kakolil Trade Agencies
Sree Tirumala Enterprises
SHUBHAM SHANKAR GAIKWAD
ASHOK BISWAS
bansal construction
V KARTHICK
M/s Ramesh Lal
BABBAR ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .