| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC OLD HASIMARA PO HASIMARA DISTT ALIIPURDUAR WB PIN 735215 | HASIMARA | ALIPURDUAR | WEST BENGAL | 735215 | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹36.4 L+₹42,620 (1.19%)Rejected-Finance MES CHOWPATTI HASIMARA DIST JALPAIGURI WB PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹36.8 L+₹84,267 (2.34%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹37.9 L+₹1.9 L (5.26%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹38.6 L+₹2.6 L (7.22%)Rejected-Finance INDEX NO D 35 ADG NEI GUWAHATI OLD HASIMARA POST HASIMARA DIST ALIPURDUAR WB PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
8 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) HASIMARA
GE (AF) HASIMARA PO HASIMARA DIST ALIPURDUAR PIN 735215 (WB)
REPAIR/MAINT OF COOLING APPLIANCE AND MISC WORK, REPAIR/MAINT OF STREET LIGHT INCLUDING REPLACEMENT OF STREET LIGHT PANEL, TIMER, JUNCTION BOX AND OTHER CONNECTED WORKS IN OMQ AREA AND REPAIR/MAINT INCLUDING REPLACEMENT OF BUILDING SECURITY LIGHTS I
2023_MES_596524_1
C/8671/23-24/E8
Open Tender
Civil Works
Item Rate
210 days
GE(AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) HASIMARA
₹72,000
Yes
30 Jun 2023
18 May 2023
15 Jun 2023
18 May 2023
8 Jun 2023
1 Jun 2023
Amount
Taking down and servicing of window type AC of 1.5 to 2 TR capacity, any type/size/make/model cleaning and washing of condenser assembly with chemical and high pressure jet pump, checking and retightening of all electrical connections, replacement of nuts, bolts, screws, washers, internal wiring and refixing properly after servicing, complete all as specified and directed. Note : (i) Spare parts & gas charging shall be measured & paid seperately under respective items.
Taking down and servicing of split (outdoor and indoor unit) type AC of 1.5/2 TR capacity of any type/size/make/model cleaning and washing of inddor and outdoor unit assembly by chemical and high pressure jet pump, checking, retightening of all electrical connections, replacement of nuts, bolts, screws, washers, internal wiring, gas charging valve,reassembling, realignment/refixing indoor and outdoor unit properly, refixing properly after repair, complete all as specified and directed. Note : (i) Spare parts & gas charging shall be measured & paid seperately under respective items.
Taking down and servicing of defective water cooler of capacity 40 to 80 Ltr of any type/make/model and cleaning, washing condenser assembly with high pressure jet pump and cleaning, rubbing and washing of storage water tank, draining of dirty water silt, checking, retightening, all electrical connections, replacement of nuts, bolts, screws, washers, drainpipe, internal wiring and reassembling properly after repair, complete all as specified and directed. Note : (i) Spare parts & gas charging shall be measured & paid seperately under respective items.
Taking down and servicing of refrigerators of 165 Ltr to 320 Ltr capacity, any type/size/make/model including replacement of unserviceable parts and cleaning, washing, condenser assembly, retighening all electrical connections, replacement of nuts, bolts, screw, washers, internal wiring, fixing properly bracket housing of capacitors and reassembling properly after repair, complete all as specified and directed. Note : (i) Spare parts & gas charging shall be measured & paid seperately under respective items.
Material and labour for testing leakage of gas and replacement of damaged portion of copper pipe of any dia upto 30cm length, brazing by oxyaccetelene gas welding and good quality copper brazing rods or soldering damaged portion, flaring copper pipe, replacement of flare nut and pouring the nitrogen gas flushing to check the leakage in copper pipe lines, recharging suitable gas fully after complete removal of nitrogen gas on satisfactorily completion of leak test, reassembling and testing cooling of whole refrigerator of any capacity/type and make, complete all as specified and directed.
All as per item No 5 here-in-above but for window type AC with R-22 gas of any capacity/make/type/model, complete all as specified and directed.
All as per item No 5 here-in-above but for water cooler with R-134 gas of any capacity/make/type/model, complete all as specified and directed.
All as per item No 5 here-in-above but for split type AC with R-22 gas of any capacity/make/type/mode/model, complete all as specified and directed.
Supply and fixing power unit with 20 Amps starter incl 4 model plate, 20A plug and socket, PVC box for mounting of power unit suitable for 20 Amps power unit and connection of electric supply and testing, complete all as specified and directed.
M&L for sub main wiring of two run 4 Sqmm single core PVC insulated, unsheathed multistranded copper conductor cable FRLSH 1100 Volts grade, drawn through and including PVC conduit of suitable size medium duty including all conduit accessories (ISI marked) to the surfaces of the wall/ceiling including one run of 4 Sqmm single core PVC insulated unsheathed copper earth continuity conductor FRLSH 1100 Volt grade including making good disturbed surface, complete all as specified and directed. (Note : Two runs of single core cable with one run of earth continuity conductor including PVC conduits accessories shall be measured and paid as one length.)
M&L for sub main wiring of two run 6 Sqmm single core PVC insulated, unsheathed multistranded copper conductor cable FRLSH 1100 Volts grade, drawn through and including PVC conduit of suitable size medium duty including all conduit accessories (ISI marked) to the surfaces of the wall/ceiling including one run of 6 Sqmm single core PVC insulated unsheathed copper earth continuity conductor FRLSH 1100 Volt grade including making good disturbed surface, complete all as specified and directed. (Note : Two runs of single core cable with one run of earth continuity conductor including PVC conduits accessories shall be measured and paid as one length.)
Dismantling and taking down from existing position window type AC 1.5/2 ton capacity and refixing the same in new position including necessary cutting opening, fixing, connecting, testing and making good disturbed surface of old position and new position etc, complete all as specified and directed.
Dismantling and taking down from existing position split type AC of capacity 1.5/2 ton and refixing the same in new position including necessary cutting opening, fixing, connecting, testing and making good disturbed surface of old position and new position etc, complete all as specified and directed. Note : Necessary gas charging, mounting stand, drain pipe and copper tube will be paid and measured seperately.
Taking down and dismantling the unserviceable blower motor from 1.5/2 TR window/split AC of any type including opening all outer case and rewinding,heat varnishing the blower motor with super enamel copper wire of suitable gauge by taking out burnt winding and cleaning the iron core, complete all as specified and directed.
All as per item No 14 here-in-above but blower motor of water cooler of capacity 40 to 80 Ltr, complete all as specified and directed.
S & F in repair potential relay box suitable for refrigerator of any make/model/capacity, complete all as specified and directed.
S & F in repair auto defrost thermostate switch suitable for refrigerator, complete all as specified and directed. Make:Ranutrol/Indfos/Denfos
S & F in repair pigmay bulb (thick/thin thread) 230 Volt suitable for refrigerator, complete all as specified and directed.
S & F in repair strainer as per sample suitable for refrigerator, complete all as specified and directed. Make: Ranutrol/Indfos/Denfos
S & F in repair harmetic sealed type compressor suitable for 180/230/310 Ltr refrigerator , complete all as specified and directed. Make : LG/Samsung/BPL/Hitachi
S & F in repair freezer fan motor single phase 230 Volt, 50 Hz suitable for refrigerator of capacity 280 to 310 Ltr, complete all as specified and directed. Make : Marathon Electric/Frac Master/M Bajaj Electric
S & F in repair cooling coil assy suitable for 180 to 310 Ltr capacity refrigerator, complete all as specified and directed.
S & F in repair defrost heater suitable for 180 to 310 Ltr refrigerator, complete all as specified and directed.
S & F in repair timer switch suitable for 180 to 310 Ltr refrigerator, complete all as specified and directed.
S & F in repair bimetal unit assy suitable for 180 to 310 Ltr refrigerator, complete all as specified and directed.
S & F in repair overload protector relay as per sample for window type AC of any make/model 1.5 -2.0 TR capacity, complete all as specified and directed.
S & F in repair potential relay box type suitable for window AC, complete all as specified and directed.
S & F in repair thermostate switch suitable for window type AC, complete all as specified and directed.
S & F fan motor, single phase 230 Volt, 50 Hz suitable for window AC, complete all as specified and directed.
S & F in repair strainer of capillary tube suitable for window AC, complete all as specified and directed.
S & F in repair harmetic sealed type compressor suitable for window AC of capacity 1.5 TR, complete all as specified and directed. Make : LG/Emerson/Hitachi/Voltas/BPL/Samsung/Carrier
S & F in repair rotary compressor of 1.5 ton capacity suitable for split type AC of any make/model 1.5 TR capacity, complete all as specified and directed. Make : LG/Emerson/Hitachi/Voltas/BPL/Samsung/Carrier
S & F in repair rotary compressor of 2.0 ton capacity suitable for split type AC of any make/model 2.0 TR capacity, complete all as specified and directed. Make : LG/Emerson/Hitachi/Voltas/BPL/Samsung/Carrier
S & F in repair power contactor suitable for 1.5/2 ton capacity split / window AC, complete all as specified and directed.
S & F in repair outdoor fan motor, single phase 230 Volt, 50 Hz suitable for split AC 1.5/2.0 TR capacity, complete all as specified and directed.
S & F in repair strainer of capillary tube suitable for split AC 1.5/2.0 TR capacity, complete all as specified and directed.
S & F in repair PCB of non invertor AC with complete accessories of any make/capacity, complete all as specified and directed. Make : LG/Samsung / Carrier / Weather Maker / Voltas
S & F in repair multi terminal capacitor (50 + 6/50 + 4mfd) suitable for split AC (stating, running and fan combined), complete all as specified and directed. Make : LG/Samsung/Carrier/Weather Maker
Supply & Fixing in repair PVC medium grade 15mm dia drain pipe for split AC as per existing, complete all as specified and directed.
Supply & Fixing in repair PCB for outdoor unit of invertor AC model and make as per existing, complete all as specified and directed.
Supply & Fixing in repair PCB for indoor unit of invertor AC model and make as per existing, complete all as specified and directed.
Supply & Fixing in repair blower motor, Indoor unit, single phase 230 V suitable for window type AC 1.5 ton, complete all as specified and directed.
S & F in repair in repair copper tube 1/4", complete all as specified and directed.
S & F in repair in repair copper tube 1/2", complete all as specified and directed.
S & F in repair in repair insulation tube 1/4", complete all as specified and directed.
S & F in repair in repair insulation tube 1/2", complete all as specified and directed.
S & F in repair in repair copper tube 5/8", complete all as specified and directed.
S & F in repair in repair insulation tube 5/8", complete all as specified and directed.
S & F in repair remote control suitable for 1.5/2 ton split/window type AC as per existing make, complete all as specified and directed.
S & F in repair overload protector relay suitable for 40 to 80 Ltr water coolers of any make/model, complete all as specified and directed.
S & F in repair potential relay box suitable for 40 to 80 Ltr water cooler, complete all as specified and directed.
S & F in repair thermostate switch suitable for 40 to 80 Ltr water cooler, complete all as specified and directed.
S & F in repair chromium plated brass push cock 1/2" (inner/outer thread) dia suitable for water cooler of any capacity, complete all as specified and directed.
S & F in repair 15mm dia PVC ball valve high pressure with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe suitable for water cooler of any capacity , complete all as specified and directed.
S & F in repair 15mm dia stop cock, cast copper alloy chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union suitable for water cooler of any capacity, complete all as specified and directed.
S & Fin repair fan motor, single, phase 230 volts 50 Hz suitable for water cooler of 40/80 ltr cooling capacity, complete all as specified and directed. Make: Marathon Electric/Frac Master/M Bajaj Electric
S & F in repair condenser unit assembly suitable for 40/80 ltr capacity water cooler, complete all as specified and directed. Make: Universal/Sarada/Keltron
S & F in repair drain pipe PVC medium grade 25mm dia with 23mm GI clamp complete for water cooler, complete all as specified and directed.
S & F in repair 15mm dia PVC cold water pipe with both ends brass/chromium coated socket suitable for water cooler, complete all as specified and directed.
S & F in repair harmetic sealed compressor suitable for cooling capacity 40/80Ltr water cooler, complete all as specified and directed. (Make: LG/Samsung/Carrier)
S & F in repair condensor unit assembly suitable for split AC 1.5 /2 ton capacity, complete all as specified and directed.
S & F outdoor blower fan blade suitable for split AC 1.5/2 ton, complete all as specified and directed.
Repair/maintenance of voltage stabilizer of capacity upto 5 KVA including replacement of driving transformer input 160 to 280 Volts and output 240 volts (+ 1%) and automatic change over circuit etc, complete all as specified and directed. Note : Minor defective parts shall be replaced by the contractor and the rate of the same shall deemed to be included in quoted rate.
Repair/maintenance of voltage stabilizer of capacity upto 2 KVA including replacement of driving transformer input 160 to 280 Volts and output 240 volts (+ 1%) and automatic change over circuit etc, complete all as specified and directed. Note : Minor defective parts shall be replaced by the contractor and the rate of the same shall deemed to be included in quoted rate.
Supply and filling of refrigerant gas R-22 in factory sealed cylinder, complete all as specified and directed.
Supply and filling of refrigerant gas R-134a factory sealed cylinder, complete all as specified and directed.
Supply and filling of refrigerant gas R-32 factory sealed cylinder, complete all as specified and directed.
Supply and filling of refrigerant gas R-410A factory sealed cylinder, complete all as specified and directed.
S & F in repair split AC outdoor mounting stand as per existing, complete all as specified and directed.
S & F in repair starting capacitor 50-100 Mfd, complete all as specified and directed. Make : Keltron/Sarada/Usha
S & F in repair running capacitor 30-50 Mfd, complete all as specified and directed. Make : Keltron/Sarada/Usha
S & F in repair flexible PVC insulated 3 core 4 Sqmm FR PVC multistranded cables with copper conductor for voltage grade upto 1100 V, complete all as specified and directed.
Supply & fixing in repair MCB single pole (SP) of capacity 6 Amps to 32 Amps, 240 Volts AC, breaking capacity 10 KA, 'C' series, fixed in proper position, complete all as specified and directed.
Supply & fixing in repair MCB Single Pole and Neutral (SPN) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position, complete all as specified and directed.
M & L for repairing of PCB of split/window type AC with changes of necessary item as required, complete all as specified and directed. Note for SL item No - 01 to 75 contractor has to arrange the Comprehensive maintenance of day to day maintenance of cooling appaliances at techical area of AF Stn Hasimara consisting of following and maintaining the records like details of complaints , completion of Job card/complaint slip on standard format and inluding completion reports of Job card from users/department and including required tools and plants , minor electrical sparers like small piece of wire, insulaton tape, screws etc required to rectifify the complaints and attending complaints in various technical Accn/LABs, etc including and replacing the spare parts in summer/cooling appliances, spares required shall be measured and paid seperately under respective items in BOQ complete as per the job card, complete all as specified and directed. Note (i): Contractor shall employ minmum one skilled technician with helper for 08 Hrs (one shift) per day (from 09.00 Hrs to 17: 00 Hrs) for 6 days in a week during contract period except on sundays and public holidays approved by GE (AF) Hasimara irrespective of number of Job cards issued to contractor. (ii) The person employed by the contractor has to check the fittings/fixtures, equipments and wiring as per the complaints/Job card, spares for replacement shall be measured and paid as supply only under respective items and no extra payment shall be done for checking/inspection of fittings .
Supply and fixing LED street light fitting 40/45 Watt 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
S & F junction box made from SMC/FRP sheet ready made of size 350X 250 X138mm with aluminium bus bar of 100 Amp capacity for RYB and half for neutral made in suitable size fixed inside the junction box with necessary supporting insulators fixed on hylem sheet, MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete, entire assembly fixed to pole /Wall with MS clamp 25 X 5mm and nuts & bolts, or inside the Copping of pole /Post top including MCB SP 6 Amp 10 KA 240 V - 1 No, with necessary size copper lugs for connecting cables from junction box to fittings, complete all as specified and directed.
S & F junction box made from SMC/FRP sheet ready made of size Junction box of size 450 X 375X 200mm with aluminium bus bar of 200 Amp capacity for RYB and half for neutral made in suitable size fixed inside the junction box with necessary supporting insulators fixed on hylem sheet ,MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete , entire assembly fixed to pole/wall with MS clamp 25 X 5mm and nuts & bolts, including MCB SP 6 Amp 10 KA 240 V - 1 No, with necessary size copper lugs for connecting cables from junction box to fittings, complete all as specified and directed.
S & F in repair cable 3 core PVC insulated unsheathed multistranded copper conductor of sie 1.5 Sqmm passing through PVC conduit from junction box to fitting, complete all as specified and directed. Note : PVC conduit shall be measured and paid seperately.
S & F in repair rigid PVC non metalic conduit 20mm dia on pole with necessary bend elbow, couplers, check nuts, FI clamp 40 x 4mm and nuts & bolts, PVC flexible conduit, connected to junction box to fitting etc including painting to clamps, complete all as specified and directed.
S & F in repair power contactors for street light after dismatling existing contactors from panel and connecting new contactors and making connection with incoming and outgoing MCCB/MCB for 3 pole power contactors, 40 Amp, ML- 3 ,2 NO+2 NC, complete all as specified and directed.
All as per item No 83 here-in-above but 3 pole power contactors, 70 Amp , ML- 4 ,2 NO+2 NC, complete all as specified and directed.
Supply and fix in repair timer for 24 hrs, complete all as specified and directed.
Supply and fix in repair MCB 63 Amp 4 pole, 10 KA 'C' series, complete all as specified and directed.
Supply and fixing post top lantern LED type 20/25 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed. Make: Bajaj Cat No : BGCTNP 20 LED WH or Crompton Cat Part No: CPB-610 - 2557SL CA -NBK or equivalent model of make : Havell's/Wipro/Philips
Supply and fixing post top lantern LED type 40/45 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed. Make: Bajaj Cat No : BGCTNP 40 LED WH or Crompton Cat Part No: CPB-610 -40- 57SL CA -NBK or equivalent model of make : Crompton/Havell's/Wipro/Philips
Supply and fixing bollard LED type 9/10/12 watt 230 watt volts AC outdoor type with necessary foundation and connection strip complete with driver and lamp, complete all as specified and directed. Make: Bajaj Cat Part No : BGBOS 650 9W LED ww or Havell's Cat Part No CONEBLS8WLED 830PSYMTOPC or Crompton Cat Part No: LBLA1-10-CDL or equivalent model of make Philips
S & F in repair driver for out door type LED fitting of capacity 40/45 Watt, complete all as specified and directed.
All as per item No 90 here-in-above but LED driver 60/75 Watt, complete all as specified and directed.
All as per item No 90 here-in-above but LED driver 90/100 Watt, complete all as specified and directed.
All as per item No 90 here-in-above but LED driver 120/150 Watt, complete all as specified and directed.
Supply, install, testing and commissioning of outdoor type cubical panel board, factory made, powder coated, provided with suitable gasket to make it dust/vermin proof for street light control panel. Incomming :- (i) MCCB 63 Amp,4 pole 16 KA - 01 No. ( ss incomming) Make: Havell's/Legrand/L & T/Siemens Outgoing :- (i) MCCB 63 Amp,4 pole 16 KA - 01 No. ( as incomming) Make: Havell's/Legrand/L & T/Siemens (ii) One No panel mounted astronomical timer with automatic On/Off through 65 Amp TP contactor and by pass function 63 Amp MCB TP for manual On-Off (iii) Indication lamp for each incoming and ougoing. (iv) Digital voltmeter 0-500 Volt. 01 No. (v) Digital Ammeter 0-100 Amp -01 No. Note: The outer shell shall be made out of 3.15mm thick CRCA sheet powder coated and suitable size MS angle section frame, factory fabricated with front openable locable/openable by keys at front side.
M & L for replacement of submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, cables 1.5 Sqmm drawn through in and including rigid PVC conduit surface type including 1.5 Sqmm 1100 Volts grade, FRLSH type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals, complete all as specified and directed. Note :- (i) Three runs of cables drawn in conduit shall be measured as one length of sub main. (ii) PVC conduit and its accessories is deemed to be included in this item rates.
S & F in repair PVC rectangular block for mounting, switches, with PVC sheet cover on top with necessary cutting for mounting switches and fixing accessories for mouting switches complete of size 100mm x 100mm and 50mm deep, complete all as specified and directed.
Supply and fixing in repair of switch piano flush button 5 Amp single pole, one way 230 volts white finish, complete all as specified and directed.
S & F junction box made from SMC/FRP sheet ready made of size 140 X 140 X 95mm with 2 way aluminium bus bar of 50 Amp capacity for made in suitable size fixed inside the junction box with necessary supporting insulators fixed on hylem sheet complete, entire assembly fixed to pole/wall with MS clamp 25 X 5mm and nuts & bolts, or inside the copping of pole/post top with necessary size copper lugs for connecting cables from junction box to fittings, complete all as specified and directed.
Supply and fixing LED flood light 50 Watt, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant , with necessary fixing arrangement with MS clamp, with suitable size bolts, nuts, washers complete of fixing arrangement on bulding wall/pole/bulding sunshade PCC block foundations at ground complete with driver and lamp, complete all as specified and directed.
All as per item No 99 here-in-above but LED flood light 100 Watt, complete all as specified and directed.
All as per item No 99 here-in-above but LED flood light 150 Watt, complete all as specified and directed. Note : An amount of Rs.27122.00 on account of credit schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
BHARAT ELECTRIC
Shri T P ANIL KUMAR
M/S RATHIN ENTERPRISES
M/S ANNI ENTERPRISE
M/S SARKAR ELECTRIC
M/S. NARENDRA KUMAR GARG
M/S BISHAL ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .