Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹31.3 L+₹4.0 L (14.5%)Rejected-Finance | L2 | Rejected-Finance HIGHER | |
| 3 | L3₹34.4 L+₹7.1 L (25.9%)Rejected-Finance | L3 | Rejected-Finance HIGHER | |
| 4 | L4₹35.4 L+₹8.0 L (29.3%)Rejected-Finance S NO 41 4K JAIHIND SOCIETY GANESH NAGAR NEAR ANAND PARK VADGAON SHERI PUNE 411 014 | PUNE | PUNE | MAHARASHTRA | 411014 | L4 | Rejected-Finance HIGHER |
Tender Value
₹38.0 L
EMD Value
₹75,980
Closing Date
13 Jun 2024, 6:00 pmClosed
GE Amritsar
GARRISON ENGINEER AMRITSAR CANTT PIN 143001
ADDN/ALTN TO BLDG NO P-77 MED OPD, MI ROOM AND DISPENSARY, P-26 GYNAE OPD, P-24 PAED OPD, SKIN AND ENT OPD OF MH AMRITSAR UNDER GARRISON ENGINEER AMRITSAR CANTT
2024_MES_654385_1
GE/ASR-47/2024-25
Open Tender
Civil Works
Works
180 days
GE Amritsar
CLASS D CATEGORY a i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹75,980
21 Sept 2024
16 May 2024
14 Jun 2024
16 May 2024
13 Jun 2024
30 May 2024
Amount
Material and Labour for Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m ; Complete all as specified and as directed by the Engineer -in-charge.
Material and Labour for Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, ; Complete all as specified and as directed by the Engineer -in-charge.
Taking down Chowkats or frames from the opening of size exceeding 1.5 sqm and not exc 4 sqm each with shutters ( without taking off shutters from the frames) ; Complete all as specified and as directed by the Engineer -in-charge.
Taking down Chowkats or frames from the opening of size not exceeding 1.5 sqm each with shutters ( without taking off shutters from the frames) ; Complete all as specified and as directed by the Engineer -in-charge.
Demolition of brickwork, built in cement mortar including all quoins, arches, pillars, etc. ; Complete all as specified and as directed by the Engineer -in-charge.
Material and Labour brick work with sub class 'B' bricks straight curved on plan exc 6 mean radius built in CM 1:6 ; Complete all as specified and as directed by the Engineer -in-charge.
Taking down cement plaster of any description on brick walls, etc including raking out joints, hacking for key scrubbing down with water etc ; Complete all as specified and as directed by the Engineer -in-charge.
Material and Labour for Rendering 15 mm thick on fair/unfair faces of brick work or concrete surfaces in CM 1:6 and to be finished even and smooth ( without using extra lime or cement) ; Complete all as specified and as directed by the Engineer -in-charge.
Material and Labour Providing and applying plaster of paris putty of 1 mm thickness over plastered surface toprepare the surface even and smooth. ; Complete all as specified and as directed by the Engineer -in-charge.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 5489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. ; Complete all as specified and as directed by the Engineer -in-charge.
Material and Labour fpr Rendering 15 mm thick on fair/unfair faces of brick work or concrete surfaces in CM 1:4 and to be finished even and smooth ( without using extra lime or cement) ; Complete all as specified and as directed by the Engineer -in-charge.
Material and Labour Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including preparation of new surfaces ; Complete all as specified and as directed by the Engineer -in-charge.
Material and Labour Finishing walls with Acrylic Smooth exterior paint of required shade : old work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including preparation of old surfaces ; Complete all as specified and as directed by the Engineer -in-charge.
Dismantling boarding , any description , fixed in any position with screws. ; Complete all as specified and as directed by the Engineer -in-charge.
Anodised aluminium snap grid 600mmx600mm frame work for false ceiling ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over aluminium snap grid 600mmx600mm frame work, or metal frame work and reinforced with G.I. wiremesh (Fillets, metal frame work and G.I. wire mesh paid separately) ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and fixing factory made uPVC white colour fixed glazed window/ventilator of any size (as required) fixed type or openable type made of frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Net opening will be measured for payment purpose.
Supply and Fixing hollow PVC wall lining consisting of Plain colour PVC sheet inclusive of solvent cement, PVC frame and all necessary items for fixing at site ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box,main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing powder coated aluminium glazed shutter(for doors) Al-section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading. ( Min. thickness of powder coating 50 micron) ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing Prelaminated particle board, exterior grade, prelaminated both sides with decorative choice laminations fixed in aluminium frame ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing Sheet glass, 5.5mm thick ordinary quality, in squares,exceeding 0.50 sqm in each pane including rubber packing and aluminium beading ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing solar control film 25 Micron reflective type sticked to glass panes as per instructions of manufacturer ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed to door shutter of size 150mm. ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing Brass mortice lock, 4 levers, verticle type, size 100 mm, ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing Brass mortice lock, 2 levers, verticle type, size 100 mm, ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing 450mm long Brass handles, cast type ; Complete all as specified and as directed by the Engineer -in-charge.
Material and Labour for frosted to toughned glass of any thickness ; Complete all as specified and as directed by the Engineer -in-charge.
Material and Labour for Embossed any type of emblem of size 0.45x0.45M on frosted glass door ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing in reapair 25mm dia stainless steel Curtain rods/ rails with Brass brackets, stops, rollers, finials, 1 pair of Brass decorative knobs for each curtain rod etc. ; Complete all as specified and as directed by the Engineer -in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises. ; Complete all as specified and as directed by the Engineer -in-charge.
Material and Labour for Vitrified ceramic dark/light shade non staining tiles 10mm thick (Square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm in floors and skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of cement mortar(1:6) 15mm thick for laying floor finishes ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing non skid ceramic light coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over and including 15mm thick screed bed in CM 1:6 & ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing glazed ceramic coloured designer tiles 450x300mmx6/7mm thick, etc. on vertical surfaces such as skirting , dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match over and including 10mm thick rendering plaster in CM 1:4 on brick surface ; Complete all as specified and as directed by the Engineer -in-charge. Note: Colour and design of tiles as per approval of Engineer-in-charge.
Supply and Fixing in repairs of One piece ceramic floor/wall mounted EWC with features like twin flush system, noisless soft close seat cover, anty-bacterial surface white with PVC(SWR) 'P' / 'S' trap 110/110mm bore ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing in repairs PVC Jet spray suitable for EWC. ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and fixing Chromium plated Health faucet in repairs with 1.5 metre long chain. ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing in repairs glass shelve assembly 60cm in oval shape consisting 5.5mm to 8mm thick glass including CP guard railing with double rail. ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing Sheet glass corner shelf assembly consisting of three nos 5.5mm to 8mm thick sheet glass corner shelf with chromium plated bracket guard and railing. ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing PVC connection 15mm size with PTMT nuts of length 600mm. ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing 15mm bore Concealed type stop cock cast copper alloy CP screwed down high pressure with crutch or butterfly handle ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing 15mm bore type angle cock cast copper alloy CP screwed down high pressure with crutch or butterfly handle ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing of brass cromium brass plated fancy type bib taps 15 mm bore long nose screwed down screwed for iron pipe or for brass ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing in repairs WHB mixture Pillar taps elbow oprated 15mm bore, cast copper alloy , with capstan heads, chromium plated , screwed down high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe and fixed. ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing in repairs PVC waste pipe 32mm dia fixed to WHB/Urinals. ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing in repairs 100mm dia CP grating with or without hole type ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing Vanity of size 820x450mm with vitreous China wash basin white,with suitable size including CP waste coupling 32mm bore,waste PVC pipe ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing in rfepairs CP brass towel rail of 20mm dia and 600mm long ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing Vitrous china white (Box type) toilet paper holder fixed to walls with chromium plated (CP) brass screws ; Complete all as specified and as directed by the Engineer -in-charge.
Taking up or down 15mm bore steel tubing and connections , including cleaning for re-fixing or removal of store. ; Complete all as specified and as directed by the Engineer -in-charge.
Taking up or down 20mm bore steel tubing and connections , including cleaning for re-fixing or removal of store ; Complete all as specified and as directed by the Engineer -in-charge..
Supply and Fixing 15mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing 20mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down ; Complete all as specified and as directed by the Engineer -in-charge.
Supply & Fixing rotational moulded polythene water storage tanks of 1000 litre capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-1 including Ball valves high pressure PTMT with epoxy coated Aluminium rod & High density plastic ball screwed for iron pipe and fixed to GI pipe of 20mm bore. ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing 110mm bore PVC(SWR) pipes single socketed in any length fixed to walls with dash true nut and bolt at every 2mtr length including) including all fittings complete all as specified and directed by Engineer-in-charge
Supply and Fixing 110mm bore PVC (SWR) bends any radius . ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing 110mm PVC (SWR) junction single, (Single T) equal or unequal ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing in repairs 100mm bore PVC (SWR) gully trap, plain with grating including jointing with solvent cement ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing framed work as door, chowkhats, and Grill gates of angle frame work fixed with Nut & bolt to wall or other section complete drilling or fixing welding be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging also festering and fixing ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240. ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws ; Complete all as specified and as directed by the Engineer -in-charge.
Material and Labour two coats of synthetic enamel painting on steel surfaces of any description over 10 cm in width or girth not otherwise described above priming coat of red oxide including prepration of previously untreated surfaces. ; Complete all as specified and as directed by the Engineer -in-charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc. ; Complete all as specified and as directed by the Engineer -in-charge.
Material and Labour for point wiring for One light point controlled by one switch complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly ; Complete all as specified and as directed by the Engineer -in-charge. NOTE: (i) Modular metal flush boxes concealed in wall with suitable cover plate for mounting switch, sockets, regulator etc. and cost of cutting chases & making good as existing to disturbed surface with cement mortar, if required any shall be deemed to included in the quoted rates. (ii) Modular fittingSupply and Fixingixtures such as switch, socket, regulator, etc., shall be measured and paid separately as under relevant item.
Material and Labour for point wiring for One Fan point controlled by one switch & regulator complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly ; Complete all as specified and as directed by the Engineer -in-charge. NOTE: (i) Modular metal flush boxes concealed in wall with suitable cover plate for mounting switch, sockets, regulator etc. and cost of cutting chases & making good as existing to disturbed surface with cement mortar, if required any shall be deemed to included in the quoted rates. (ii) Modular fittingSupply and Fixingixtures such as switch, socket, regulator, etc., shall be measured and paid separately as under relevant item.
Material and Labour for point wiring for One 5 Amps outlet point on same board with other switches/sockets complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly ; Complete all as specified and as directed by the Engineer -in-charge. NOTE: (i) Modular metal flush boxes concealed in wall with suitable cover plate for mounting switch, sockets, regulator etc. and cost of cutting chases & making good as existing to disturbed surface with cement mortar, if required any shall be deemed to included in the quoted rates. (ii) Modular fittingSupply and Fixingixtures such as switch, socket, regulator, etc., shall be measured and paid separately as under relevant item.
Material and Labour for point wiring for One 3 pin 5 Amps socket outlet on independent board. complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly ; Complete all as specified and as directed by the Engineer -in-charge. NOTE: (i) Modular metal flush boxes concealed in wall with suitable cover plate for mounting switch, sockets, regulator etc. and cost of cutting chases & making good as existing to disturbed surface with cement mortar, if required any shall be deemed to included in the quoted rates. (ii) Modular fittingSupply and Fixingixtures such as switch, socket, regulator, etc., shall be measured and paid separately as under relevant item.
All as per ser item No. 69 here in above but point wiring with 2.5 Sqmm FRLS cable and 2.5 sqmm cable earth continuity wire for one 3 pin socket outlet,15 Amps on independent board.
Supply and Fixing modular switch 1 way 6A, 240 volts, 1 module ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing modular switch 1 way 16A, 240 volts, 1 module ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing modular socket, 6A, 240 volts, 2/3 pin combined 2 module, flush type ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing modular socket, 6A/16A, 240 volts, 2/3 pin combined 2 module flush type ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing ceiling rose surface PVC/Polycarbonate, isolated body with face Bakelite 65 x 50 mm three terminal, 240 volts, AC single phase ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing sheet steel metal enclosure single pole & neutral with a 2 pin and earth plug and socket complete with one single pole MCB SP 20 Amp, 240 volts ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing Lamp holder angular type, PVC/Polycarbonate type with back plate suitable for batten fittings including 10cm x 10cm presto plastic board for resting to holder including Supply and Fixing 01 x 10/12 watts LED lamp, 230 volts ; Complete all as specified and as directed by the Engineer -in-charge.
Material and Labour for distribution board, vertical, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, VTPN 4 way, 415 volts grade with insulated rated bus bar assembly with isolated neutral bar,door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCCB, MCB TPN/TP/SPN/SP etc, including dismantling of old UNSV one from site ; Complete all as specified and as directed by the Engineer -in-charge..
Material and Labour for distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, TPN 4 way, 415 volts grade with 200 Amps insulated rated bus bar, earth bar IP- 43 & IK-09, door earthing flush to wall, including testing suitable for fixing MCB SPN, SP etc, ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing MCB of SP 5 to 32 Amps current carrying capacity, 240 V, 10KA 'C' curve fixed in the MCB DB complete with connection testing & commissioning ; Complete all as specified and as directed by the Engineer -in-charge.
All as per ser item No. 80 above but for MCB TP 40 Amps, 415 V grade ; Complete all as specified and as directed by the Engineer -in-charge.
All as per ser item No. 80 above but for MCB TPN 63 Amps, 415 V grade ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing MCCB triple pole and neutral (four pole) 100 Amps, 415 volts, 50 Hz, having thermal setting range 70% to 100% and adjustable magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and fixing sub main wiring with 4 runs of 16.0 sqmm single core, multi-stranded PVC insulated, FRLS sheathed cable 1100 Volts grade with copper conductor drawn through and including non metalic PVC conduit, medium grade, not less than 25mm dia, ISI marked, with conduit fittings and accessories not less than 25mm dia concealed in wall/ceiling/floor including 2 runs run of 16.0 Sqmm multistranded PVC insulated FRLS, copper conductor cable as earth continuity conductor and connecting to common earth dolly ; Complete all as specified and as directed by the Engineer -in-charge. NOTE: Four runs of 16.0 sqmm copper cable and two run of 16.0 sq mm copper cable alongwith non metallic PVC conduit/conduit accessories not less than 25mm dia will be measured as one unit length
All as per ser item No. 84 above but for sub main wiring with 2 run of 6 sqmm & 1 run of 6 sqmm as earth wire ; Complete all as specified and as directed by the Engineer -in-charge.
All as per ser item No. 84 above but for sub main wiring with 2 run of 4 sqmm & 1 run of 4 sqmm as earth wire ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing LED lights fitting 1x 20W, 220V, AC, 5700K, decorative box type with driver, double sided connection, CRI> 80, PF>95%, THD<10%, Lumen>2100 lm including LED tube light connecting up with 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing Wall mounted, indoor, HELIOS Mirror Light LED with aluminium die cast, suitable for and including 10 watt 6000K, WH LED light, prewired with 3 core flexible copper cable (1.0 mm² size/core) from connector to light fittings and connecting up ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing Dusk & dawn roadway luminaries 35 Watt, 230 V AC, 5700K outdoor type with epoxy black powder coated sheet, high pressure die-cast aluminum hosing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optics, PF>95%, THD<10%, Lumen>4500 lm with IP 65/66 protection complete incl connecting wire with flexible PVC insulated copper cables from ceiling rose to fitting including driver, lamp bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length not exceeding 1.5 mtr, through mild steel clamp of 25mm width and four Nos. nuts, bolts & washers of 12mm dia, 100mm long fixed to wall with all other fittings complete and testing ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing PLUTO NEO LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases (1.0 mm² size/core) ; Complete all as specified and as directed by the Engineer -in-charge.
Supply and Fixing ceiling fan 1200mm sweep complete with blades, down rod as per site requirement, electronic regulator & accessories (i.e. PVC canopy, rubber bush, split pin, hanging clamp, holdfasteners etc.) 230 Volts, white colour, with min air delivery 210 CFM, BEE 5 star rated with brushless direct current motor (BLDC) technology and connecting up with & including 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose to ceiling fan and writing MES No. ; Complete all as specified and as directed by the Engineer -in-charge.
Supply, install & testing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, single phase, 1200 RPM, Copper winding of sweep 300mm complete fixed/grouted to wall with suitable bolts, nuts etc., and connecting up with & including 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose to exhaust fan and writing MES No. including cutting hole suitable for fixing exhaust fan ; Complete all as specified and as directed by the Engineer -in-charge.
Material & Labour in repairs earthing complete with galvanised earth plate electrode 600mm X 600mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 metres below ground level) with top edge of earth plate not less than 1.5metres below normal ground level, connected to GI Wire of size 4mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No.3 of MES SSR 2009, Part – I (Specifications) and connected to main switch board/LT feeder panel including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in alternate layers with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150mm both ways center to center with suitable lifting handle to cover, earth pit made of PCC 1:3:6 type C-1, GI protection pipe light grade 20 mm bore up to 7.5metres length from earth electrode including testing ; Complete all as specified and as directed by the Engineer -in-charge. NOTE: (i) Earth lead and protection pipe beyond 7.5 m shall be measured and Paid separately. (ii) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt. (iii) Rate quoted shall be inclusive of excavation and earth work and PCC all as specified in the item (iv) Earthing work will be carried out in the presence of MES representative
GEE EMM ASSOCIATES
M/s AKG Engineers & Contractors
Om Infra
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .