| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-Finance | ₹40.4 L | L1 | Accepted-Finance BEING L1 |
| 2 | L2₹43.0 LAccepted-Finance | ₹43.0 L | L2 | Accepted-Finance BEING NOT L1 |
| 3 | L3₹44.3 LAccepted-Finance | ₹44.3 L | L3 | Accepted-Finance BEING NOT L1 |
| 4 | L4₹45.3 LAccepted-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | ₹45.3 L | L4 | Accepted-Finance BEING NOT L1 |
| 5 | L5₹45.4 LAccepted-Finance SR NO 331 2B PLOT NO 43 R H NO 02 BALDEWA RAO BUNGLOW NEWA NMC WATER TANK PATHARDI SHIVAR NASHIK 422 009 INDEX NO E 84CWE AF LOHEGAON PUNE | NASHIK | MAHARASHTRA | 422009 | ₹45.4 L | L5 | Accepted-Finance BEING NOT L1 |
| Sl No | Description | Qty | Unit | MAHIMA CONSTRUCTION L6 | United Enterprises L2 | SHRI SULAI ELECTRICALS L3 | Shree Sai Samarth Enterprises L5 | YASHRAJ ELECTRICALS L7 | VINIT ASHOK KORE L1 | DURGAI ELECTRICALS L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for taking down Window type air conditioner of any type/make/capacity after disconnecting all electric connection from site (either in ground / any floor), transporting to work site if required, cleaning of air filter, front panel, suction grill, De-dusting of coupler unit, checking electrical connection, cleaning the condenser, brush cleaning the whole unit with electric blower, cleaning with water, descaling with non corrosive acid on both side of cooling coil and components, identifying the fault/ trouble in the unit and their redressal, reassembling and refixing the covers and making electrical connections, installation the machine in same position, testing and commissioning complete all as specified and as directed by Engineer-in-Charge (Note: Repair/Replacement of the component required shall be paid under relevant item of schedule here-in-after). (Note:- For Sl No 1 - 112, if any complain not rectified within 24 hrs with user's satisfactory working report penalty of Rs 500 per defect per day shall be recovered from the contractor in FB) | 3 | EACH Job | 494 ₹1,482 | 370 ₹1,110 | 540 ₹1,620 | 571 ₹1,713 | 555 ₹1,665 | 350 ₹1,050 | 431 ₹1,293 |
| 2.00 | Supply & Fix in repairs air filter elemant pads for window type A/C for 1.5 TR/ 2 TR of size and make during the maintenance complete all as specified & as directed by Engineer-In -Charge. | 3 | Each | 135 ₹405 | 100 ₹300 | 170 ₹510 | 145 ₹435 | 140 ₹420 | 100 ₹300 | 167 ₹501 |
| 3.00 | Supply & Fix in repairs louvers swing motor suitable for window type AC of cap 1.5/2.0 ton cap in situ as per existing make and compatible model, necessary electrical connection and testing after fixing to entire satisfaction of user and Engr-in-Charge. | 3 | Each | 282 ₹846 | 175 ₹525 | 210 ₹630 | 223 ₹669 | 220 ₹660 | 180 ₹540 | 256 ₹768 |
| 4.00 | Supply and fix in repairs blower drum, suitable for window type AC 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed by Engineer-in-Charge | 3 | Each | 951 ₹2,853 | 825 ₹2,475 | 1,000 ₹3,000 | 849 ₹2,547 | 1,035 ₹3,105 | 725 ₹2,175 | 784 ₹2,352 |
| 5.00 | Repairs to Micro-processor electronic circuit board (PCB) suitable for 1.5/2.0 ton window type AC including disconnection and taking out unsv PCB and and fixing after repairs, testing complete as per existing make/model complete all as specified & as directed by Engineer-In -Charge. | 3 | Each | 933 ₹2,799 | 795 ₹2,385 | 1,010 ₹3,030 | 979 ₹2,937 | 815 ₹2,445 | 800 ₹2,400 | 795 ₹2,385 |
| 6.00 | Supply & Fix in repairs Condensor fan motor double shaft 1/6Hp, 1/8Hp, 1/10Hp for Window type AC of 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and directed by Engineer In Charge | 3 | Each | 1,724 ₹5,172 | 980 ₹2,940 | 1,810 ₹5,430 | 1,682 ₹5,046 | 1,735 ₹5,205 | 900 ₹2,700 | 1,771 ₹5,313 |
| 7.00 | Supply & Fix in repairs blower motor single phase AC 200/230 volts suitable for window type A/C for 1.5 TR/ 2 TR complete all as specified & as directed by Engineer-In -Charge. | 3 | Each | 1,121 ₹3,363 | 630 ₹1,890 | 1,070 ₹3,210 | 1,032 ₹3,096 | 1,105 ₹3,315 | 600 ₹1,800 | 885 ₹2,655 |
| 8.00 | Supply & Fix in repairs Air filter suitable for window type AC 1.5 /2.0 TR capacity as per existing make and model complete all as specified & as directed by Engineer-In -Charge. | 3 | Each | 383 ₹1,149 | 190 ₹570 | 340 ₹1,020 | 308 ₹924 | 310 ₹930 | 180 ₹540 | 361 ₹1,083 |
| 9.00 | Supply & Fix in Repairs new sealed unit compressor of 1.5 TR window type room air conditioner (Make: As Per Exisiting or Equivalant) complete all as specified & as directed by Engineer-In -Charge. Note - Cost of Refrigerant gas and Gas charging is deemed to be included in the unit rate quoted of this item. | 3 | Each | 5,386 ₹16,158 | 3,865 ₹11,595 | 4,460 ₹13,380 | 5,911 ₹17,733 | 5,460 ₹16,380 | 3,500 ₹10,500 | 6,002 ₹18,006 |
| 10.00 | Supply and Fix in Repairs new sealed unit compressor of 2.0 TR window type room air conditioner (Make: As Per Exisiting or Equivalant) complete complete all as specified & as directed by Engineer-In -Charge. Note - Cost of Refrigerant gas and Gas charging is deemed to be included in the unit rate quoted of this item. | 3 | Each | 5,943 ₹17,829 | 4,840 ₹14,520 | 7,380 ₹22,140 | 5,642 ₹16,926 | 6,675 ₹20,025 | 4,500 ₹13,500 | 6,320 ₹18,960 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 Apr 2026, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR AIR FORCE STATION OJHAR Dist NASHIK PIN 422221
REPAIR AND MAINT OF SUMMER APPLIANCES AND REPLACEMENT TO UNSERVICEABLE PIPE LINE/ PUMP SET/ BOREWELL IN EXTERNAL WATER SUPPLY AND MAINT PUMP HOUSE AT 11 BRD AF STN OJHAR UNDER GE AF OJHAR
2026_MES_758985_2
8396/E8
Open Tender
Miscellaneous Works
270 days
GE AF OJHAR
As per tender documents
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹80,000
Yes
13 May 2026
17 Apr 2026
1 May 2026
17 Apr 2026
29 Apr 2026
24 Apr 2026
17 Apr 2026 - 23 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for taking down Window type air conditioner of any type/make/capacity after disconnecting all electric connection from site (either in ground / any floor), transporting to work site if required, cleaning of air filter, front panel, suction grill, De-dusting of coupler unit, checking electrical connection, cleaning the condenser, brush cleaning the whole unit with electric blower, cleaning with water, descaling with non corrosive acid on both side of cooling coil and components, identifying the fault/ trouble in the unit and their redressal, reassembling and refixing the covers and making electrical connections, installation the machine in same position, testing and commissioning complete all as specified and as directed by Engineer-in-Charge (Note: Repair/Replacement of the component required shall be paid under relevant item of schedule here-in-after). (Note:- For Sl No 1 - 112, if any complain not rectified within 24 hrs with user's satisfactory working report penalty of Rs 500 per defect per day shall be recovered from the contractor in FB) | - | EACH Job | - | - |
| 2 | Supply & Fix in repairs air filter elemant pads for window type A/C for 1.5 TR/ 2 TR of size and make during the maintenance complete all as specified & as directed by Engineer-In -Charge. | - | Each | - | - |
| 3 | Supply & Fix in repairs louvers swing motor suitable for window type AC of cap 1.5/2.0 ton cap in situ as per existing make and compatible model, necessary electrical connection and testing after fixing to entire satisfaction of user and Engr-in-Charge. | - | Each | - | - |
| 4 | Supply and fix in repairs blower drum, suitable for window type AC 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed by Engineer-in-Charge | - | Each | - | - |
| 5 | Repairs to Micro-processor electronic circuit board (PCB) suitable for 1.5/2.0 ton window type AC including disconnection and taking out unsv PCB and and fixing after repairs, testing complete as per existing make/model complete all as specified & as directed by Engineer-In -Charge. | - | Each | - | - |
| 6 | Supply & Fix in repairs Condensor fan motor double shaft 1/6Hp, 1/8Hp, 1/10Hp for Window type AC of 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and directed by Engineer In Charge | - | Each | - | - |
| 7 | Supply & Fix in repairs blower motor single phase AC 200/230 volts suitable for window type A/C for 1.5 TR/ 2 TR complete all as specified & as directed by Engineer-In -Charge. | - | Each | - | - |
| 8 | Supply & Fix in repairs Air filter suitable for window type AC 1.5 /2.0 TR capacity as per existing make and model complete all as specified & as directed by Engineer-In -Charge. | - | Each | - | - |
| 9 | Supply & Fix in Repairs new sealed unit compressor of 1.5 TR window type room air conditioner (Make: As Per Exisiting or Equivalant) complete all as specified & as directed by Engineer-In -Charge. Note - Cost of Refrigerant gas and Gas charging is deemed to be included in the unit rate quoted of this item. | - | Each | - | - |
| 10 | Supply and Fix in Repairs new sealed unit compressor of 2.0 TR window type room air conditioner (Make: As Per Exisiting or Equivalant) complete complete all as specified & as directed by Engineer-In -Charge. Note - Cost of Refrigerant gas and Gas charging is deemed to be included in the unit rate quoted of this item. | - | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TENDER8396.pdf
Tender Documents • 0.99 MB
BOQ_852051.xls
BOQ • 1.09 MB
Download all tender documents and submit your bid