Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L1 | Accepted-AOC THE ACCEPTANCE LETTER | |
| 2 | L2₹43.3 L+₹58,069.80 (1.36%)Rejected-Finance LODHI NAGAR NEAR TEACHERS COLONY GALI NO 4 MAHOLI ROAD MATHURA U P 281004 | MATHURA | MATHURA | UTTAR PRADESH | 281004 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹44.2 L+₹1.5 L (3.46%)Rejected-Finance 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
8 Nov 2022, 6:00 pmClosed
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
PROVN OF DEFICIENT EM APPLIANCES AT MD ACCN OF MATHURA MIL STN AND PROVN OF EM SERVICES INCL 250 KVA, 3 PHASE WITH NEUTRAL AT 440 VOLTS TRANSFORMER, WATER AND SEWAGE SUPPLY FOR PLANNED CT SCAN FACILITY BLDG AND MINOR WORK 3 AND 8 UNDER GE (E) MATHURA
2022_MES_552242_2
8200-1298/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE EAST MATHURA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE EAST MATHURA
₹95,000
26 Nov 2022
18 Oct 2022
10 Nov 2022
18 Oct 2022
8 Nov 2022
25 Oct 2022
18 Oct 2022 - 1 Nov 2022
Amount
M&L point wiring for one light point as fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC single core unsheathed multi strand copper conductor FRLS cable in and including concealed PVC conduit 20 mm dia, medium duty, ISI marked including PVC single core sheathed 1.5 Sqmm copper conductor cable FRLS as earth wire connected to common earth dully complete all as specified and as directed. Note : Sunken box plate with frame, switches, sockets etc shall be measured and paid for separately under appropriate items of Sch 'A'.
S&F modular switch, one way 6 Amp 240 Volt, 1 module etc complete all as specified and as directed.
S&F steel metal modular flush box 1/2 module having holes for 20 mm conduit entry, suitable for fixing modular cover plate of size 2 module complete all as specified and as directed.
S&F white modular cover plate with frame, 1 module suitable for fixing modular switch complete all as specified and as directed.
S&F modular switch socket combination 16 Amp 6 Pin, 3 module complete all as specified and as directed.
S&F steel metal modular flush box 3 module having holes for 20 mm conduit entry, suitable for fixing modular cover plate of size 3 module complete all as specified and as directed.
S&F modular white cover plate with frame, 3 module suitable for fixing modular switch and sockets complete all as specified and as directed.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and as directed.
S&F ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified and as directed.
S&F instant water heater (Geyser) storage type 3 liters capacity, 230 Volts, 50 Hz, vertical type, outer ABS rust free body, glass lined inner steel walled tank, including grouting of studs in wall clamps, nuts, bolts, washers and provision of two numbers flexible hot water PVC connection heavy duty 450mm long with brass nuts complete all as specified and as directed.
S&F electric water heater storage type with inner steel enamelled tank and heating element 2KW capacity 25 liter, BEE 5 star rated complete with all connections, such as safety valve, thermostate, NRV connection pieces etc including grouting studs in wall, clamps, nut, bolt washers and provn of two numbers flexible hot water PVC connection heavy duty 450mm long with brass nuts complete all as specified and as directed.
S&F mild steel tubes 15mm bore medium grade, galvanised with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F stop valve cast copper alloy, fancy type, chromium plated screwed down, high pressure with crutch or butterfly handle screwed both ends for 15mm bore dia pipe iron pipe or union complete as specified and as directed.
S&F Brass chromium plated mixer for mixing hot & cold water screwed down for 15mm bore dia iron pipe complete all as specified and as directed.
S&F sheet metal enclosures single pole with two pin socket and earth plug complete with and including SP 20 Amps 240 volts MCB etc complete all as specified and as directed.
S&F Sub main wiring with two run of single core cable PVC insulated copper conductor FR cable of size 4 sqmm, 1100 votls grade drawn through and including 20mm dia bore ISI marked PVC conduit including acessories such as Tee, bend, Elbow etc, with and including one run PVC insulated 4.0 sqmm single core sheathed FR copper conductor cable for earth continuity and connected to common earth dolly etc complete all as specified and as directed. Note : Three lengths of 4 Sqmm cable and one length of PVC pipe shall be measured as one unit length.
S&F Sub main wiring with two run single core cable PVC insulated copper conductor FR cable of size 2.5 sqmm, 1100 votls grade drawn through and including concealed 20 mm dia bore PVC conduit including acessories such as Tee, bend, Elbow etc, with and including PVC insulated 2.5 sqmm sheathed FR copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and as directed. Note : Three lengths of 2.5 Sqmm cable and one run of one pipe will be measured as one unit length.
S&F MCB 6 Amps to 32 Amps SP capacities 'C' series 10KA rupturing capacaity complete all as specified and as directed.
Supply, installation, testing and commissioning outdoor type, floor mounted step down non sealed type transformer, 11/0.433 KV, powder coated of capacity 250 KVA, core type, double copper wound, oil immersed, naturally cooled, oil natural-air natural with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with neutral brought out on secondary side (LV side) and having taping at ± 2.5%,+5.0% & ± 7.5 % on HV side to be changed by means of hand operated off load tap changing gear. the maximm temperature rise should not exceed 40 degree celsius in oil and 45 degree celsius in HV/LV winding when measured by resistance method after coontinuous full load run. The transformer shall be conforming to IS-1180 updated,level-2 (2 star). Dilectric strength of transformer oil not less than 40 KV and it has accessories such as LT Box at LT side, silica gel breather, oil level indicator conservator tank with oil level indicator, drain out valve (oil tank), exhaust vent, air release valve, temperature gauge and cast iron wheel etc complete all as specified and as directed.
Note : Quotated rate shall be inclusive of providing 100 mm PCC platform on top of brick masonry of Size 3.00 X 2.5 mtrs (outer dimensions) and 1.2 mtr high from ground level and 0.5 mtr below ground level for placing Transformer and steps complete as detail below and as directed. (i) Excavation and earth work for foundation, brick masonary including R/F and removing surplus soil. (ii) 100 mm thick cement concrete 1:4:8 type D-2 in foundation of brick masonary . (iii) Brick work with fly ash brick in CM 1:6 including 15mm thick plastering in CM 1:4 over exposed surfaces. (iv) 100mm thick hard core using brick bats of gauge n.exc 63mm. (v) 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base. (iv) 100mm thick PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) as in flooring finished even and fair. (vii) Two coats of cement base paint over a coat of cement primer over plastered surfaces complete. (viii) Earth filling including watering and ramming in layers of 25cm thick inside the platform complete. (Earth obtained from excavation shall be used for filling.
Supply and erecting steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts & washers as per IS 2713 (Part-II) 1980 made out of mild steel tubing, type 410 SP-55 (11.00 metre long) including marking pole No on pole including painting of poles with one coat of red oxide primer and two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and directed by Engr in Charge. Note : Earth work and PCC in foundation shall be measured and paid separately under relevent item(s) of BOQ.
Supply, installing and testing of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amp capacity for 11 KV complete all as specified and as directed.
M&L for fixing air break gang operated switch triple pole 11000(11KV) volt mechanically operated mounted on insulators horizontal/vertical type including MS galvanised steel frame with operating mechanism worked from ground level for current rating of cap 400 Amps complete all as specified and as directed.
S&F expulsion fuse single pole, upto 100 Amps for 11000(11KV) Volt working pressure complete all as specified and as directed.
Supply and erecting steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts & washers made out of mild steel tubing, type 410 SP -31 (9 Mtr long) including marking pole No on pole including painting of poles with one coat of red oxide primer and two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and as directed. Note : Earth work and PCC in foundation shall be measured separately.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation & laying of cable etc. and getting out in soft/loos soil complete all as specified and as directed.
All as per Serial item No 25 here-in-before but depth etc 1.5 m but n exc 3.00 m complete all as specified and as directed.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping complete all as specified and as directed.
M&L for cable route indicator built of cement concrete 1:2:4 type B1, (using 20mm graded stone aggragate) of size 40x50x20cm errected on 15cm below ground level on PCC plateform 1:4:8 type D2 of size 40x40x10cm, and 10mm thick rendering on concrete surface showing "HT Cable" and route/joint of cable with arrow, painted the plaster surface with synthetic enamel paint and arrow and works with different tint of paint complete all as specified and as diected.
M & L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending colt or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
Supply laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminum conductor,11000V earthed grade, of cross section area 95 sq mm 3 core complete all as specified and as directed.
M&L for filling fine river sand in trenches for protection of cable 8 cm before laying of cable and 15cm after laying of cable and punned to required depth complete all as specified and as directed. Note : Punned depth shall only be measured for payment.
Supply and laying reinforced precast concrete cable cover class HV type-I flat size 300 mmx180mmx40mm complete all as specified and as directed.
Supply and laying reinforced precast concrete cable cover class LV type-II flat size 250mmx150mmx40mm complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick using excavated hard/dense soil complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 sqmm complete all as specified and as directed.
Supply laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, heavy duty electric cables with aluminum conductor, 1100 volts grade, 3.5 core of cross sectional area 150 sqmm complete all as specified and as directed.
All as per serial item No 39 here-in-before but of cross section area 120 sqmm complete all as specified and as directed.
All as per serial item No 39 here-in-before but of cross section area 95 sqmm complete all as specified and as directed.
M&L mild steel tube 50 mm bore light grade, galvanised with all fitting for cable protection fixed on walls/poles/laid in trenches complete all as specified and as directed.
All as per serial item No 42 here-in-before but 80mm bore complete all as specified and as directed.
All as per serial item No 42 here-in-before but 100mm bore complete all as specified and as directed.
Supply and laying synthetic rubber insulation mats 25mm thick for voltage upto 11KV for electric pupose as per IS-15652-2006 (superseding IS-5424) suitable for electric shock safety of size 2 x 1m complete all as specified and as directed.
All as per serial item No 45 here-in-before but 20 mm thick complete all as specified and as directed.
Supply, installing, commissioning and testing of LT panel board outdoor type, cubical type made out CRCA sheet 3.15 mm thick CRCA and inner sheet 2.0mm thick suitable for 415 volt, 50HZ, 4 wire inculiding dust and vermin proof and angle iron of suitable size, pedestal flame grouted in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregated) thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminum bus bar of suitable size, (in separate chamber rating not less than the 1.5 times the rated capacity of incoming MCCB) including painting with two coats synthetic enameled paint over a coat of red oxide primer and consisting of the following complete all as specified and directed. (a) MCCB 400 Amp, 4 pole, 36 kA thermal adjustable & magnetic adjustable, ICS=100% Icu - 01 Each (b) MCCB 250 Amp , 4 pole, 16 kA - 02 Each (c) MCCB 100 Amp , 4 pole,16 kA - 01 Each (d) Digital Amp meter (0-250) - 01 Each (e) Digital Volt meter (0-500) - 01 Each (f) RYB Indicator - 01 Set Note : The drawing of panel shall be got approved from Engineer-in-Charge before placing order for procurement.
Supply, installing, commissioning and testing of LT Bus Bar board outdoor type, cubical type made out CRCA sheet 3.15 mm thick CRCA and inner sheet 2.0mm thick suitable for 415 volts, 50HZ, 4 wire including dust and vermin proof and angle iron of suitable size, pedestal flame grouted in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregated) thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminum bus bar of of suitable size, (in separate chamber rating not less than the 1.5 times the rated capacity of incoming MCCB) including painting with two coats synthetic enameled paint over a coat of red oxide primer and consisting of the following complete all as specified and as directed. (a) MCCB 250 Amp , 4 pole,16 kA - 01 Each (b) Digital Amp meter (0-250) - 01 Each (c) Digital Volt meter (0-500) - 01 Each (d) RYB Indicator - 01 Set Note : The drawing of panel shall be got approved from Engineering-in-Charge before placing order for procurement.
Supply and fixing V-TPN, 4 way, double door sheet metal enclosure made out of CRCA mild steel sheet concealed/surface mounting , 415 Volt, with 200 Amp rated bus bar suitable for fixing MCBs, isolators etc including 160 Amp MCCB, 4 pole complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode size 600mm x 600mm x 6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to GI earth strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40mm dia connected to main earth wire on pole or control board and GI pipe medium grade 20mm dia bore for watering funnel with wire mesh. RCC cover with concrete (1:2:4) type B-1 using 8mm bars @ 100mm C/C both way with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion including taking down existing earthing complete all as specified & directed. Note : The unit rate includes for protection pipe and GI Earth strip 32 x 6mm from top of earth plate upto 7.5m above ground level.
M&L for earthing complete with galvanized steel earth plate electrode size 600 mm x 600 mm x 6.3 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron wire 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth lead on pole or control board and GI pipe light grade 20 mm dia for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with cement concrete 1:3:6 type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on complete all as specified and as directed. Note : GI wire and protection pipe upto 7.5 Mtr length from earth electrode shall be included in quoted rate of item.
M&L for GI strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle complete all as specified and as directed.
Excavation in post hole (or similar hole) each n exc 0.5 cum,getting out,returning,filling in and ramming earth or broken rubble mixed with earth around,in layers not exceeding 25 cm in soft/loose soil complete all as specified and as direceted.
Supply only chain link fencing made out of 4mm dia mild steel galvanised wire of mesh size 40mm any size complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rail, straining bolts etc including provision of binding wire complete all as specified and as directed.
Supply and fixed mild steel section for post and struts in fencing including cutting top to shape as directed, drilling hole notching for wire etc or flat iron fillet (for security wire mesh etc) including all necessary drilling, bolting or riverting etc confirming to Fe-290 Gde E-165 complete all as specified and as directed.
Supply and fixed mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5 cm long & dia of shank 11 to 15 mm complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified and as directed.
Supply and laying crusted stone aggregate of gauge 45 mm at installation complete all as specified and as directed.
Supply and Fixing of desert cooler, 4000 CFM, cabinet locally fabricated with three side panels front, top and tank including vertical mention made out 22 SWG GI sheet of standard size with double diversion grills and grill box suitable for 450 mm sweep fan duly painted by super enamelled paint making holes with fixing arrangement incl 4 way PVC distributor assembly, PVC pipe for spray water, wood wool pads, electrical wiring, fan & pump set regulated with regulators complete controlled separately with 5 amp Piano type switch and indicator etc complete all as specified and as directed.
S&F in repair modular socket outlet 5 Pin 5 Amp 230 volts AC, 2 module complete all as specified and as directed.
S&F mild steel framework as in brackets, cooler stands etc. including cutting welding and fixing at any height in existing masonry walls including scaffolding required confirming to Fe-390 Gde E-165 complete all as specified and as directed.
Supply & fixing LED street light fittings of 70 Watt,230 V AC,outdoor type with high pressure die cast aluminium housing, heat resistant, corrosion resistant, toughened glass with IP66 protection including thermal management in multiple optics including suitable nut & bolts for fixing of fitting with GI brecket on pole, complete with all connections as specified and as directed. Note : GI bracket, MS clamps, nuts, bolts is including in quoted rates.
Supply and fixing junction box out door type of external dimensions 250 mm x 200 mm x 105 mm, single door type hinged with locking arrangement front operated, 3 phase and neutral bus bar including MCB SP 6 Amp and connecting the incoming/out going cables with nuts, bolts etc complete all as pecified and as directed.
Supply & laying of UG cable XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor 1100 volts grade cross section area 10 Sqmm x 4 core laid in trenches/ fixing on panels/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing complete all as specified and as directed.
Supply and fixing three core FRLS PVC insulated flexible stranded copper conductor cable of size 1.5 Sqmm for electric connections to Street lights from junction box complete all as specified and as directed.
Supply & fixing Automatic Security light control panel having sheet steel enclosure power coated CRCA sheet suitable for three phase,6 KW rating, outdoor installation,floor mounted, IP 54 protected including making all connections and grouted in PCC of type B-1 (1:2:4) with foundation should be 100mm above ground level complete with comprising of the following switch gears:- (i) MCB TPN 40Amp rating - 01 No (ii) Digital Timer Switch - 01 Nos (iii) Contactor with nominal current rating 32Amp TP (iv) Outgoing MCB SP with Suitable rating - 03 Nos (v) Auto/manual switch (vi) Incoming and outgoing terminal suitable for three phase supply. (vii) MS cable glands for entry & exist point of cables.
ISHWAR ENTERPRISES
shyam construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .