| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | L1 | Accepted-AOC Admitted | |
| 2 | L2₹12.6 L+₹3,770 (0.30%)Rejected-AOC 109 D ALLAI SALT COMPOUND OLD LAKSHMI THEATRE KRISHNAPURAM COONOOR 643102 THE NILGIRIS | COONOOR | THE NILGIRIS | TAMIL NADU | 643102 | L2 | Rejected-AOC Admitted | |
| 3 | L3₹13.6 L+₹99,545 (7.91%)Rejected-AOC CHENNAI | CHENNAI | TAMIL NADU | 600001 | L3 | Rejected-AOC Admitted | |
| 4 | L4₹14.8 L+₹2.2 L (17.5%)Rejected-AOC H NO 111 553 64 CATTLE POUND TOWARDS AVA HILL CAMP ROAD ARUVANKADU NILGIRIS DIST TAMIL NADU 643 202 | THE NILGIRIS | TAMIL NADU | 643202 | L4 | Rejected-AOC Admitted | |
| 5 | L5₹16.3 L+₹3.7 L (29.7%)Rejected-AOC 20 1 CHANDRA NIVAS APPLEBY ROAD WELLINGTON COONOOR NILGIRIS 643 232 | COONOOR | NILGIRIS | TAMIL NADU | 643232 | L5 | Rejected-AOC Admitted |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
26 May 2021, 6:00 pmClosed
GE Wellington
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
ROOF TREATMENT AT KENDRIYA VIDYALAYA UNDER GE WELLINGTON
2021_MES_434921_1
8630/E8
Open Tender
Civil Works
Item Rate
120 days
Wellington
As per Tender Documents
4 documents required · 4 mandatory
₹500
GE Wellington
₹26,000
Yes
3 Jun 2021
7 Apr 2021
28 May 2021
8 Apr 2021
26 May 2021
21 Apr 2021
Amount
Demolition of brick tiles or terracing tiles, single layer on roofs all as specified and ditrected.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc ,complete all as specified and as directed
Providing plain cement concrete 1:2:4 type B0 using 12.5mm graded aggregate, 25mm thick as in levelling / padding course on roof slab, projections on silimar surfaces existing with slope, making the surface even and smooth without using extra cement all as specified and directed.
Rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished, laid over the RCC roof slab, parapet wall when the concrete is green at any hight and making the surface fair and even witout using extra cement including using liquid integral WPC as per manufacturers instructions complete all as specified and directed. Note: Supply of liquid integral water proofing compound will be measured and paid seperately.
Supply only liquid water proofing compound all as specified and directed.
APP modified prefabricated polymeric membrane 4mm thick and weighing not less than 4.5 kg/sqm reinforced with non-woven polyster matt black finished weighing not less than 100 gm/sqm having softning not less than 140 degree celsius longitudinal tensil strength not less than 300N/sqcm, side lap and end lap 10cm with torch application of membrane over compatible primer @ 0.40 Ltr/sqm and aluminium paint @ 0.10 kg/sqm on top complete all as specified and directed.
Pre-cast cement concrete block masnory with solid block exceeding 10cm in width and setting in mortar 1:4 type C1 1:3:6 using 20mm graded aggregate complete all as specified and directed
Rendering 10 mm thick in cement mortar 1:4 on fair faces of PCC block masonry finished even and fair all as specified and directed.
Forming 20mm thick expansion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound, grade A for 150mm thick concrete slab all as specified and directed.
Precast RCC (1:2:4) type B1 (using 20 mm graded granite/trap stone aggregate) as in slabs, set in cement mortar 1:4 including form work all as specified and directed.
Mild steel TMT bars 6 to 8mm dia cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers, binders, etc complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for 32mm bore all as specified and directed
Taking up or down steel tubing and connections including cleaning for 25mm bore all as specified and directed
GI pipe 32mm bore medium grade with all GI fittings fixed on wall, ceiling or laid in floors complete all as specified and directed.
GI pipe 25mm bore medium grade with all GI fittings fixed on wall, ceiling or laid in floors complete all as specified and directed.
Refixing old steel tubing 32mm bore pipes and connections in new or old positions (walls, ceiling, floors etc) all as specified and directed.
Refixing old steel tubing 25mm bore pipes and connections in new or old positions (walls, ceiling, floors etc) all as specified and directed.
Gunmetalglobe or gate valve with iron wheel head screwed both ends for iron pipe of size 32mm bore all as specified and directed.
Gunmetalglobe or gate valve with iron wheel head screwed both ends for iron pipe of size 25mm bore all as specified and directed.
Disconnecting existing tanks of capacity 2000 ltrs setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and refixing in position and cleaning and removing all scale and dirt, etc from tanks and from mouth of circulating pipes, etc all as specified and directed.
Disconnecting existing tanks of capacity 1000 ltrs setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and refixing in position and cleaning and removing all scale and dirt, etc from tanks and from mouth of circulating pipes, etc all as specified and directed.
Disconnecting existing tanks of capacity 500 ltrs setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and refixing in position and cleaning and removing all scale and dirt, etc from tanks and from mouth of circulating pipes, etc all as specified and directed.
Dismantling PVC water tank exceeding 500 ltrs and not exceeding 1000 Ltr capacity from existing position and removing to store all as specified and as directed.
Dismantling PVC water tank exceeding 250 ltrs and not exceeding 500 Ltr capacity from existing position and removing to store all as specified and as directed.
Rotational moulded polyethylene water storage tank of capacity 500 Ltr (cylindrical vertical with closed top) three layers hoisted and fixed in position with proper inlet and outlet connections all as specified and as directed
Rotational moulded polyethylene water storage tank of capacity 1000 Ltr (cylindrical vertical with closed top) three layers hoisted and fixed in position with proper inlet and outlet connections all as specified and as directed
Ball brass valve high pressure with polythene float and fly nut complete, screwed for iron pipe or for brass ferrule and fixed in repairs float valve of 20mm dia all as specified and directed.
Racking out joints to brick tiles 30cm by 15cm laid flat as in floors, roofs, ceilings, chajjas etc all as specified and directed.
Flush pointing in cement morter including waterproofing compound to 30cm by 15cm brick tiles, laid flat on roof complete all as specified and directed.
Plain cement concrete Type B0 1:2:4 using 12.50mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
K.AYYAPPAN
KRA Engineering and Construction
sree devi construction
P K ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .