Facilities Management Division, Bangalore
HINDUSTAN AERONAUTICS LIMITED Facilities Management Division, Bangalore
Proposed Construction of LCH Full Motion Simulator Building for MCSRDC Division HAL DC
25451
TENDER NOTICE/NCP/01/26-27
Limited
Works
Contract Section Civil-FMD-Bangalore
| # | Company Name | Location | Address |
|---|---|---|---|
| 1 | H A Vinodkumar | Mysore,India | H A VINODKUMAR NO.49/A ,4TH MAIN ,MARUTHI TEMPLE ROAD, KUVEMPUNAGAR, MYSURU,,Mysore,Karnataka,India,Pin-570009 |
| 2 | M/s JYOTI SARUP MITTAL | NEW DELHI,India | C 1483 WAZIR NAGAR KOTLA MUBARAKPUR NEW DELHI,28-29/205A LINK ROAD LAJPAT NAGAR III NEW DELHI,NEW DELHI,Delhi,India,Pin-110024 |
| 3 | RAWALI CONSTRUCTION PRIVATE LIMITED | GHAZIABAD,India | GROUND FLOOR, FLAT NO-02, KM-46, HAPUR ROAD, KAVI NAGAR, GHAZIABAD, UTTAR PRADESH, 201002,,GHAZIABAD,Uttar Pradesh,India,Pin-201002 |
H A Vinodkumar
Mysore,India
H A VINODKUMAR NO.49/A ,4TH MAIN ,MARUTHI TEMPLE ROAD, KUVEMPUNAGAR, MYSURU,,Mysore,Karnataka,India,Pin-570009
M/s JYOTI SARUP MITTAL
NEW DELHI,India
C 1483 WAZIR NAGAR KOTLA MUBARAKPUR NEW DELHI,28-29/205A LINK ROAD LAJPAT NAGAR III NEW DELHI,NEW DELHI,Delhi,India,Pin-110024
RAWALI CONSTRUCTION PRIVATE LIMITED
GHAZIABAD,India
GROUND FLOOR, FLAT NO-02, KM-46, HAPUR ROAD, KAVI NAGAR, GHAZIABAD, UTTAR PRADESH, 201002,,GHAZIABAD,Uttar Pradesh,India,Pin-201002
₹0
₹23.4 L
23 May 2026
18 Apr 2026
18 Apr 2026
23 May 2026
HINDUSTAN AERONAUTICS LIMITED BANGALORE FACILITIES MANAGEMENT DIVISION
NAME OF THE WORK: “Proposed Construction of LCH Full Motion Simulator Building for MCSRDC Division, HAL [DC]." CONTRACT NO. HAL/FMD/C-01/26-27
Name of the Contractor :
Sl. No. Specification Quantity Unit Rate in Figs [Excluding GST] Rate in Words Amount
Preamble: (1) The subject work has been called on works contract basis and prevailing GST for same is 18%. Any change in GST +/- during the currency of contract shall be on HAL account. The Tenderer shall abide by prevailing GST act. (2) L1 (lowest quote) will be determined based on the total quoted amount including GST. (3) This BOQ specification has to be read in conjunction with detailed technical specification and tender drawings if any.
Part 'I' - Civil Works
1 Removing / transporting the surplus excavated earth including debris, vegetation waste, concrete waste, etc., to a distance upto 5000m from HAL premises to contractor's own yard including loading, unloading, depositing, spreading, levelling, etc., all complete as directed by Engineer-in-Charge. 1211.37 Cu m #NAME? 0.00
2 Carriage / Transportation of dismantled steel mechanically including stanchions, purlins, etc., to a distance upto 1km within HAL premises / to the Maintainance Dept including loading, unloading and stacking, etc., all complete as directed by Engineer-in-Charge. 25.55 M T #NAME? 0.00
3 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas in all kinds of soft / hard soil for foundations, footings, column pedestals or members as per the drawing or as per directions of EIC, etc., (exceeding 30cm in depth, 1.50m in width as well as 10Sq m on plan) including removal of vegetation and in-equalities, shoring, strutting for protecting the sides of foundation if required, removing slips or falls in excavation, forming steps in sides of deep excavations and their removal or covering up, levelling, ramming the bottom of excavation, getting out and disposal of excavated earth lead upto 50m for all lifts with all labour, tools & tackles, plant & machinery, hire & fuel charges, etc., all complete as directed by Engineer-in-Charge. 3661.00 Cu m #NAME? 0.00
4 Returning / Filling in available useful excavated earth (excluding rock) free from salts, organic or other deleterious matter (Other than black cotton soil & rock, etc.,) in trenches, plinth, sides of foundations, etc., in layers not exceeding 20cm in depth, consolidating each deposited layer by watering, breaking / removing clods exceeding 50mm, ramming and consolidation, etc., with all labour, tools & tackles, plant & machinery, etc., lead up to 50m and lift upto 1.50m, etc., all complete as directed by Engineer-in-Charge. 2449.63 Cu m #NAME? 0.00
5 Supplying and filling with sand under floors, footings, etc., including watering, ramming, consolidating and dressing, etc., all complete as directed by Engineer-in-Charge. 4.00 Cu m #NAME? 0.00
6 Providing and laying in position cement concrete excluding the cost of centering and shuttering for all work up to plinth level including base cources in flooring of 1:2:4 (1 cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources), etc., all complete as directed by Engineer-in-Charge. 39.00 Cu m #NAME? 0.00
7 Providing and laying in position cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20mm nominal size derived from natural sources) - All work up to plinth level, including mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions, etc., but excluding the cost of centering and shuttering, etc., all complete as directed by Engineer-in-Charge. 259.00 Cu m #NAME? 0.00
8 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth, etc., all complete as directed by Engineer-in-Charge. 156.00 Sq m #NAME? 0.00
9 Supplying, mixing and placing plain cement concrete (1:2:4) of required thickness using 20 mm nominal size down graded hard stone/granite aggregate in accordance with IS 456 in Cills, fillets, coping,etc upto floor five level, including formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc., but excluding the cost of centering, shuttering and finishing, all complete as directed by the Engineer-in-Charge. 14.00 Cu m #NAME? 0.00
10 Formwork (Centering and shuttering including strutting, propping, etc., and removal of form) for the following RCC members which are defined as below, in fair finished by providing timber, wooden planks, runners / M.S. sheets with all supports, struts, braces, wedges, scaffolds, bracings, ladders, gangways, dressing with oil including M.S. bolts nuts and washers, temporary openings, filleting for a stop, chamfered edges, internal / external splayed, rounded angles or grooves for forming throating including making temporary openings in the forms for pouring concrete, etc., all complete as directed by the Engineer-in-Charge for the sub-items mentioned below. Note: Formwork material is contractor's own property and shall be removed after completion of work.
a) Foundations, footings, bases of columns,bed concrete, ramp concrete, pedestal, etc., for mass concrete 855.54 Sq m #NAME? 0.00
b) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses, cable trench walls, etc., 648.00 Sq m #NAME? 0.00
c) For Roofs, landings,suspended floors, Slabs supported on walls, roofs, landings, balconies, access platforms, Gutters, decks, etc., up to 3.50m. 238.00 Sq m #NAME? 0.00
d) For Roofs, landings,suspended floors, Slabs supported on walls, roofs, landings, balconies, access platforms, Gutters, decks, etc., @ 4.20m 711.00 Sq m #NAME? 0.00
e) For Roofs, landings,suspended floors, Slabs supported on walls, roofs, landings, balconies, access platforms, Gutters, decks, etc., @ 5.00m 184.00 Sq m #NAME? 0.00
f) For Roofs, landings,suspended floors, Slabs supported on walls, roofs, landings, balconies, access platforms, Gutters, decks, etc. @ 10.80m 36.00 Sq m #NAME? 0.00
g) For Roofs, landings,suspended floors, Slabs supported on walls, roofs, landings, balconies, access platforms, Gutters, decks, etc., @ 16.00m 88.00 Sq m #NAME? 0.00
h) Plinth beams, Lintels beams, room beams, beams, girders, bressumers and cantilevers, etc., 2343.00 Sq m #NAME? 0.00
i) For Columns, Pillars, Piers, etc., 1255.37 Sq m #NAME? 0.00
j) Stairs, (excluding landings) 74.00 Sq m #NAME? 0.00
k) Small lintels not exceeding 1.50m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 85.00 Sq m #NAME? 0.00
l) Chajja, Weather shade, Canopies, Corbels, etc., including edges 146.42 Sq m #NAME? 0.00
m) Edges of slabs and breaks in floors and walls under 20cm wide 451.00 R m #NAME? 0.00
11 Supplying, straightening, fabricating (cutting & bending), placing in position and binding steel reinforcement of TMT bars of not less than Fe 500 D conforming to IS 1786 for all concrete reinforcment members / works above/below plinth level, including cutting to length, bending to shape required, including cranking, bending spirally for hooping for column, hooking ends and binding with mild steel wire (Annealed) not less than 0.90mm dia or securing with clips, including fixing and bracing, wastage, welding, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it, etc., complete all as per specifications, drawings and as directed by the Engineer-in-Charge. Note: a) Only authorized laps, chairs etc. shall be considered for measurement. b) The exposed Reinforcement bars shall be coated with cement slurry. 138349.00 Kgs #NAME? 0.00
12 Providing and laying in position ready mixed or site batched M25 Grade with minimum cement content of 330 kg/m3 design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, consolidation, levelling, curing, scaffolding, all materials, labour, carriage for all leads & lifts but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-Charge. Note: (i) Site design mix to be obtained from Govt. / NABL laboratory for site batching concrete. (ii) Small quantity is as approved by EIC in volumetric proportion.
a) All works upto plinth level including necessary openings and packing if any for laying pipes, cables, etc., 850.00 Cu m #NAME? 0.00
b) All works above plinth level upto floor V level including necessary openings and packing if any for laying pipes, cables, etc., 713.00 Cu m #NAME? 0.00
13 Providing and fixing expansion hold fasteners on CC / RCC / Brick masonry surface backing including drilling necessary holes and the cost of bolt of Wedge expansion type, etc., all complete as directed by Engineer-in-Charge.
a) Fastener with threaded dia 6mm each 50.00 Each #NAME? 0.00
b) Fastener with threaded dia 10mm each 190.00 Each #NAME? 0.00
14 Supplying, fabricating and fixing second class teak wooden plain, solid, straight chowkats and frames of doors, windows, partitions, wall panelling frames and other frames, wrought framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed to wall or in position with hold fast lugs or with dash fasteners of required dia & length, etc., all complete as directed by the Engineer-in-Charge. 0.48 Cu m #NAME? 0.00
15 Providing, fabricating and fixing 35mm thick flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood & lipping with 2nd class teak wood battens 25mm minimum depth on all edges and well matched commercial 3 ply veneering with vertical grains or cross bands including ISI marked Stainless Steel butt hinges with necessary screws and face veneers on both faces of shutters and provision of rebates, suitable blocks for taking mortice locks, latches or other fittings, fitting to frames / chowkats, etc., all complete as directed by the Engineer-in-Charge. Note: Fittings / hardware shall be paid separately. 11.76 Sq m #NAME? 0.00
16 Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with CP brass screws and PVC sleeves, etc., wherever necessary, etc., all complete as directed by the Engineer-in-Charge. 6.00 R m #NAME? 0.00
17 Providing and fixing M.S. grills of required pattern to steel windows / walls / in frames of windows, ventilators, etc., and approved design using MS structurals such as M.S flats, angles, round / square bars, etc., including necessary cutting, welding, embedding in concrete, masonry, etc.,including priming coat with approved steel primer, etc., all complete as directed by the Engineer-in-Charge. 2119.00 Kgs #NAME? 0.00
18 Providing [40 x 5]mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block [30 x 10 x 15]cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size), etc., all complete as directed by the Engineer-in-Charge. 27.00 Each #NAME? 0.00
19 Providing and fixing bright finished brass butt hinges [125 X 70 X 4]mm with necessary screws, etc., all complete as directed by the Engineer-in-Charge. 14.00 Each #NAME? 0.00
20 Supplying and fixing the Polished (bright finished) brass barrel type tower bolts 250mm long X 10mm with barrel of extruded sections of brass, of approved make and rolled or drawn brass bolt, design to door with all required screws, bolts, nuts, washers, etc., conforming to IS 204 (Part 2) all complete as directed by the Engineer-in-Charge. 4.00 Each #NAME? 0.00
21 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc, all complete as directed by the Engineer-in-Charge. 4.00 Each #NAME? 0.00
22 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kgs to 80 kgs and door width from 701mm to 1000mm), with double speed adjustment with necessary accessories and screws, etc., all complete as directed by the Engineer-in-Charge. 34.00 Each #NAME? 0.00
23 Providing chromium plated brass 100mm mortice latch and lock with 6 levers and a pair of lever handles / single handles of approved quality with necessary screws, etc., of approved quality, suitable for respective Wood / Aluminium door of approved manufacture to door with all necessary screws, bolts, nuts and washers of approved manufacture, etc., all complete as directed by the Engineer-in-Charge. 11.00 Each #NAME? 0.00
24 Providing and fixing aluminium sliding door bolts(aldrop) of [250 x 16]mm , ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws, etc., all complete as directed by the Engineer-in-Charge. 4.00 Each #NAME? 0.00
25 Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, etc., all complete as directed by the Engineer-in-Charge. 16.00 Each #NAME? 0.00
26 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section [90 x 45]mm having single rebate of [32 x 15]mm to receive shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame, etc., all complete as directed by the Engineer-in-Charge. 34.65 R m #NAME? 0.00
27 Providing and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels, including provision of internal wood lipping, rebates, suitable blocks for taking mortice locks, latches or other fittings, fitting to frames / chowkats, etc., conforming to IS: 14856, etc., all complete as directed by the Engineer-in-Charge. 14.04 Sq m #NAME? 0.00
28 Providing and fixing Fixed Partition with using R3 series with frame (55mm & above ) x (45mm & above) & mullion (55mm & above) x (65mm & above) factory made uPVC glazed / wire mesh windows / doors comprising of lead free uPVC multi-chambered frame, sash and mullion / coupler (where ever required) extruded profiles having minimum wall thickness of 1.70mm for Series R1 and R2 profiles and 2.10mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded / mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water, etc., After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, etc., all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge including all fixures except Glass. (Height upto 1.2 metre) 12.10 Sq m #NAME? 0.00
29 Providing and fixing factory made uPVC glazed doors using R3 series with frame (55mm & above) x (50mm & above) & sash (55mm & above) x (85mm & above) & French (False) mullion (55mm & above) x (60mm & above) comprising of lead free uPVC multi-chambered frame, sash and mullion / coupler (where ever required) extruded profiles having minimum wall thickness of 1.70mm for Series R1 and R2 profiles and 2.10mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded / mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water, etc., After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, etc., all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. (Height upto 2.5 metre). Note:- The rate quoted is Including all fixures except Glass. 16.56 Sq m #NAME? 0.00
30 Providing and fixing zinc alloyed (white powder coated) Touch lock for UPVC / Aluminium sliding window with necessary screws, etc., all complete as per the architectural drawings and the directions of Engineer-in-Charge. 33.00 Each #NAME? 0.00
31 Providing and fixing fire resistant door frame of section [50 x 60]mm on horizontal side & [35 x 60]mm on vertical sides having built in rebate made out of 1.60mm thick GI sheet (Zinc coating not less than 120 gm/Sq m) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled with mineral wool Insulation having density minimum 96Kg/Sq m. The frame will have a provision of G.I. anchor fastners 14 nos (5 each on vertical style & 4 on horizontal style of size M10 x 80) suitable for fixing in the opening along with factory made template for SS ball bearing hinges of size [100 x 89 x 3]mm for fixing of fire rated glazed shutter. The frame shall be finished with an approved fire resistant primer or powder coating of not less than 30 micron in desired shade, etc., all complete as directed by the Engineer-in-Charge. (Cost of SS ball bearing hinges is excluded). 74.00 R m #NAME? 0.00
32 Providing and fixing 60mm thick glazed fire resistant door shutters of 120 minutes Fire rating conforming to 1S:3614 (Part Il) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail [60 x 60]mm wide and bottom rail of [110 x 60]mm made out of 1.60mm thick G.I. sheet (zinc coating not less than 120 gm/Sq m) duly filled mineral wool insulation having density minimum 96 kg/Cu m and fixing with necessary stainless steel ball bearing hinges of size [100 x 89 x 3]mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron, etc., all complete as directed by the Engineer-in-Charge. [Supply of hinges to be paid extra]. 39.00 Sq m #NAME? 0.00
33 Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions, etc., with G.I. beading made out of 1.60mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) of size [20 x 33]mm screwed with M4 x 38mm SS screws at distance 75mm from the edges and 150mm c/c , including applying a coat of approved fire resistant primer / powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of [5 x 20]mm size, etc., complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-Charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report / certificationof fire glass and the glass should have the stamp showing the value of E, EW & El. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredited labs as per ISO / IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than [1100 x 2200]mm (w xh) or 2.42 Sq m, etc., all complete as directed by the Engineer-in-Charge. 1.00 Sq m #NAME? 0.00
34 Providing of SS Ball Bearing Hinges of size [100 X 89 X 3]mm for the door frame to door shutter, etc., all complete as directed by the Engineer-in-Charge. 48.00 Each #NAME? 0.00
35 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, etc., all complete as directed by the Engineer-in-Charge. 12125.00 Kgs #NAME? 0.00
36 Fixing only Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, etc., all complete as directed by the Engineer-in-Charge. 25552.00 Kgs #NAME? 0.00
37 Steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel, etc., as required. In stringers, treads, landings, etc., of stair cases, cable trench covers with chequered plate as per the requirement, etc., all complete as directed by the Engineer-in-Charge. 3934.00 Kgs #NAME? 0.00
38 Providing and fixing stainless steel (Grade 304) railing of approved size/design by welding etc. made of Hollow tubes, channels, plates, etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts, etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-Charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners, etc.,), etc., all complete as directed by the Engineer-in-Charge. 1143.00 Kgs #NAME? 0.00
39 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing, welding in position for supporting structures and applying a priming coat of approved steel primer all complete, etc., all complete as directed by the Engineer-in-Charge. 4010.00 Kgs #NAME? 0.00
40 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) total thickness of 40mm with 20mm nominal size stone aggregate finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps, etc., all complete as directed by the Engineer-in-Charge. 141.00 Sq m #NAME? 0.00
41 Cement concrete pavement / flooring with 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size), including finishing, forming of contruction joints / grooves, etc., all complete as directed by the Engineer-in-Charge. 11.00 Cu m #NAME? 0.00
42 Providing and laying Double Charged vitrified floor tiles polished finish size of tile Size of [600 X 600]mm or nearest available size in floors over a screed of cement mortar (1:4) 20mm thick for Paper Joint (Thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 course sand), including grouting the joints with grey cement slurry @ 3.3 Kg/Sq m including grouting the joints with white cement and matching pigments, etc., all complete as directed by the Engineer-in-Charge. 396.80 Sq m #NAME? 0.00
43 Providing and laying Glazed vitrified tiles Matt / Anti skid polished finish size in floors as indicated below for Paper Joint of tile size of [600 X 600]mm (Thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 course sand), including grouting the joints with grey cement slurry @ 3.3 Kg/Sq m including grouting the joints with white cement and matching pigments, etc., all complete as directed by the Engineer-in-Charge. Note: Quoted rate shall be inclusive of screed, pointing, etc., 73.87 Sq m #NAME? 0.00
44 Providing and laying Vitrified tiles in Skirting / Dadoo for walls / wall clad over a screed of cement mortar (1:3) -Size of Tile [600 x 600]mm or nearest size available (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/Sq m including grouting the joint with white cement & matching pigments, etc., all complete as directed by the Engineer-in-Charge. 209.28 Sq m #NAME? 0.00
45 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing, providing anti slip grooves in steps / stairs, etc., all complete as directed by the Engineer-in-Charge. Note:- Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 20.00 Sq m #NAME? 0.00
46 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing, including nosing, providing anti slip grooves in steps / stairs, etc., all complete as directed by the Engineer-in-Charge. Note: Polished Granite stone slab of all colour and texture except Black, Cherry / Ruby Red. 132.06 Sq m #NAME? 0.00
47 Providing, fixing, testing and commissioning single socketed pipes of 75mm dia, on wall face unplasticised Rigid PVC water pipes of 6 kg/cm² SWR grade and of approved make conforming to IS : 13592 Type A, including jointing together with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion and all necessary fittings & specials, bends, branches, sockets, clamps, pipe cutting and wastages, cutting and making good the walls, connecting to existing lines, etc., along with removal of existing rain water pipes, etc., all complete as directed by the Engineer-in-Charge. 22.50 R m #NAME? 0.00
48 Providing, fixing, testing and commissioning single socketed pipes of 110mm dia, on wall face unplasticised Rigid PVC water pipes of 6 kg/cm² SWR grade and of approved make conforming to IS : 13592 Type A, including jointing together with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion and all necessary fittings & specials, bends, branches, sockets, clamps, pipe cutting and wastages, cutting and making good the walls, connecting to existing lines, etc., along with removal of existing rain water pipes, etc., all complete as directed by the Engineer-in-Charge. 352.00 R m #NAME? 0.00
49 Supplying and fixing of Trapezoidal roofing and Wall cladding sheet: Supply of pre-painted Zincalume trapezoidal sheets shall be made of 0.50mm TMT (0.50mm TCT excluding paint), (min 240 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return. The steel sheet is having high tensile sheet (Fy=Min 240Mpa), metallic coated with Zinc-Aluminium alloy (i.e. 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min 150 gm/m2 total on both side), pre-painted with Ultra Durable Polyester (UDP) Colorbond XRW quality paint with stable inorganic pigment with no lead contents for colour durability (High SRI-”Thermatech technology”). The steel sheet shall have total paint coating thickness of 35microns as 20 microns on exposed surface and 5 micron reverse polyester coat on back surface over 5 micron primer coat on both surfaces of apporved color. The exposed paint system shall have stable inorganic pigments for better color performance conforming to AS/NZS 2728 type-4 / IS15965 class 3 for the durability. The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. 562.00 Sq m #NAME? 0.00
The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. The steel sheet shall be fastened with 25 μm zinc-tin alloy coated, Hex head, self-drilling screw as per AS 3566 Class 4 fasteners of approved make (Buildex / Roofix) with EPDM washer as per the requirement considering the profile shape and design load. The fastener size shall be calculated as per the design or manufacturers recommendations. The profile sheet, fastener size etc. shall be approved by the concern authority. All the accessories like gutter / flashing / capping shall be made from the same material (or manufacturer’s recommendation) which is used for main cladding application. The measurement shall be based on finished / covered surface area.
50 Providing and fixing pre-painted galvalume steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with with AZ150 (min 150 gm/m2 total on both side), pre-painted with Ultra Durable Polyester (UDP) Colorbond XRW quality paint , in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling / self tapping screws, etc., all complete as directed by the Engineer-in-Charge.
a) Ridge Plain for width up to 600mm. 17.00 R m #NAME? 0.00
b) Flashings upto 600mm width 66.00 R m #NAME? 0.00
c) Crimp Curve 20.00 Sq m #NAME? 0.00
d) Gutter with overall girth of 600mm. 34.00 R m #NAME? 0.00
51 Providing, applying and laying 12mm thick cement plaster work in for Internal / External areas of Ceilings, Chajjas bottoms, slabs in floor, etc., in CM (1:4) including forming grooves n.exc 10mm wide and not exceeding 10mm deep as per requirement as directed including preparation of surface by hacking, etc., at all levels with necesary materials, labour, scaffoldings, curing, tools and tackles, plants, etc., threading if any as directed, etc., all complete as directed by the Engineer-in-Charge. 134.42 Sq m #NAME? 0.00
52 Providing, applying and laying cement mortar (1:6) plastering 15mm thick on brick / solid blocks / lath plastering/concrete, below tiles for matching the height surfaces, finished even and smooth with trowel for Internal / External walls, etc., including supply and fixing of hexagonal chicken mesh minimum 150mm wide having opening [20 x 20]mm of 26 gauge at juncitons of concrete & brick work or between different material, including making grooves as per the requirement not exceeding 10mm width and not exceeding 10mm deep with necesary materials, labour, scaffolding, curing, tools and tackles, etc., all complete as directed by the Engineer-in-Charge. [For Height up to 10.0m] 3273.00 Sq m #NAME? 0.00
53 Providing, applying and laying cement mortar (1:6) plastering 15mm thick on brick / solid blocks / lath plastering / concrete, below tiles for matching the height surfaces, finished even and smooth with trowel for Internal / External walls, etc., including supply and fixing of hexagonal chicken mesh minimum 150mm wide having opening [20 x 20]mm of 26 gauge at juncitons of concrete & block work or between different material, including making grooves as per the requirement not exceeding 10mm width and not exceeding 10mm deep with necesary materials, labour, scaffolding, curing, tools and tackles, etc., all complete as directed by the Engineer-in-Charge. [For Heights Between 10-13m] 568.00 Sq m #NAME? 0.00
54 Providing, applying and laying cement mortar (1:6) plastering 15mm thick on brick / solid blocks / lath plastering / concrete, below tiles for matching the height surfaces, finished even and smooth with trowel for Internal / External walls, etc., including supply and fixing of hexagonal chicken mesh minimum 150mm wide having opening [20 x 20]mm of 26 gauge at juncitons of concrete & block work or between different material, including making grooves as per the requirement not exceeding 10mm width and not exceeding 10mm deep with necesary materials, labour, scaffolding, curing, tools and tackles, etc., all complete as directed by the Engineer-in-Charge. [For Heights Between 13-16m] 491.00 Sq m #NAME? 0.00
55 Providing, applying and laying cement mortar (1:6) plastering 15mm thick on brick / solid blocks / lath plastering / concrete, below tiles for matching the height surfaces, finished even and smooth with trowel for Internal / External walls, etc., including supply and fixing of hexagonal chicken mesh minimum 150mm wide having opening [20 x 20]mm of 26 gauge at juncitons of concrete & block work or between different material, including making grooves as per the requirement not exceeding 10mm width and not exceeding 10mm deep with necesary materials, labour, scaffolding, curing, tools and tackles, etc., all complete as directed by the Engineer-in-Charge. [For Heights Between 16-19m] 204.00 Sq m #NAME? 0.00
56 Providing, applying 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge including supply and fixing of hexagonal chicken mesh minimum 150mm wide having opening [20 x 20]mm of 26 gauge at juncitons of concrete & brick work or between different material, along with mixing of water proofing material (material is paid separately), with necesary materials, labour, scaffoldings, curing, tools and tackles, plants etc., threading if any as directed, etc., all complete as directed by the Engineer-in-Charge. [For Height up to 10.0m] 3365.00 Sq m #NAME? 0.00
57 Providing, applying and 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge including supply and fixing of hexagonal chicken mesh minimum 150mm wide having opening [20 x 20]mm of 26 gauge at juncitons of concrete & brick work or between different material, along with mixing of water proofing material (material is paid separately), with necesary materials, labour, scaffoldings, curing, tools and tackles, plants, etc., threading if any as directed, etc., all complete as directed by the Engineer-in-Charge. [For Height from 10.0m-13.0m] 281.72 Sq m #NAME? 0.00
58 Providing, applying and 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge including supply and fixing of hexagonal chicken mesh minimum 150mm wide having opening [20 x 20]mm of 26 gauge at juncitons of concrete & brick work or between different material, along with mixing of water proofing material (material is paid separately), with necesary materials, labour, scaffoldings, curing, tools and tackles, plants, etc., threading if any as directed, etc., all complete as directed by the Engineer-in-Charge. [For Height from 13.0m-16.0m] 195.40 Sq m #NAME? 0.00
59 Providing, applying and 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge including necessary preparation of surface, at all levels including supply and fixing of hexagonal chicken mesh minimum 150mm wide having opening [20 x 20]mm of 26 gauge at juncitons of concrete & brick work or between different material, along with mixing of water proofing material (material is paid separately), with necesary materials, labour, scaffoldings, curing, tools and tackles, plants, etc., threading if any as directed, etc.,all complete as directed by the Engineer-in-Charge. [For Height from 16.0m-19.0m] 183.00 Sq m #NAME? 0.00
60 Providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers per bag of 50kg cement used in the mix, etc., all complete as directed by the Engineer-in-Charge. 600.00 per bag of 50kg cement used in the mix #NAME? 0.00
61 Painting newly plastered external surfaces with two or more coats applied at 1.43 litre / 10 Sq m / as per manufacturer specifications of 100% premium acrylic emulsion paint having VOC less than 50 grams / litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint with silicon additives of approved make, colour, shade, tint & pattern at all levels, over and including a coat of approved acrylic primer including preparing the surface by removing loose dirt and any organic growth, filling of cracks, necessary scaffolding, etc., all complete as directed by the Engineer-in-Charge. Note: The paint shall have anti-algal, anti-fungal, UV resistant & anti-tarnishing qualities with 100% acrylic base and silicon or elastomeric additives. 4016.12 Sq m #NAME? 0.00
62 Painting Steel surfaces of any description with two coats of synthetic enamel paint of approved colour, brand and manufacture to give an even shade, including preparation of surface by rubbing with fine grade of abrasive paper to ensure smooth, etc., all complete as directed by the Engineer-in-Charge. 1666.00 Sq m #NAME? 0.00
63 Painting newly plastered interior surfaces of Walls and Ceiling with two coats of premium acrylic emulsion paint of interior grade having VOC (Volatile Organic Compound) content less than 50 grams / litre conforming to IS 15489 of approved make, brand, colour, shade, tint, manufacture & pattern at all levels, including preparing the surface by removing loose dirt and any organic growth, smoothening the surface by using suitable emery paper, filling crevices and finishing even and smooth by providing and applying white cement based putty of average thickness of 1mm in 2 coats of approved brand and manufacture over the plastered wall surface and followed by the applying priming coat with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content With water thinnable cement primer on applied putty having VOC content less than 50 grams / litre, necessary scaffolding, etc., all complete as directed by the Engineer-in-Charge. 3297.00 Sq m #NAME? 0.00
64 French Polishing on wood work on New work with two or more coats including a coat of wood filler, etc., all complete as directed by the Engineer-in-Charge. 12.00 Sq m #NAME? 0.00
65 Demolishing Nominal cement concrete 1:3:6 or richer mix (including equivalent design mix) manually / by mechanical means including disposal of material within 50 metres lead, etc., all complete as directed by the Engineer-in-Charge. 48.00 Cu m #NAME? 0.00
66 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead, etc., all complete as directed by the Engineer-in-Charge. 43.00 Cu m #NAME? 0.00
67 Demolishing brick work built in cement mortar manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead, etc., all complete as directed by the Engineer-in-Charge. 48.00 Cu m #NAME? 0.00
68 Demolishing stone rubble masonry built in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead, etc., all complete as directed by the Engineer-in-Charge. 26.00 Cu m #NAME? 0.00
69 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding including dismembering and stacking, etc., all complete as directed by the Engineer-in-Charge. 20937.43 Kgs #NAME? 0.00
70 Extra for marking of structural steel work required to be re-erected, etc., all complete as directed by the Engineer-in-Charge. 20937.43 Kgs #NAME? 0.00
71 Dismantling roofing sheets including ridges, hips, valleys and gutters, rolling shutters with curtain etc., and stacking the material within 50 metres lead, etc., all complete as directed by the Engineer-in-Charge. 322.00 Sq m #NAME? 0.00
72 Dismantling and stacking within 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of made out of "T’ or ‘L’ iron or pipe or structural steel members, etc., all complete as directed by the Engineer-in-Charge. 25.00 Each #NAME? 0.00
73 Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead, etc., all complete as directed by the Engineer-in-Charge. 166.00 Kgs #NAME? 0.00
74 Dismantling precast concrete or stone slabs like granite platforms, etc., of thickness up to and including 40mm in walls, partition walls, over platforms, etc., including stacking within 50 metres lead / hading over to maintenance department, etc., all complete as directed by the Engineer-in-Charge. 5.00 Sq m #NAME? 0.00
75 Dismantling G.I. pipes (external work) of 15mm to 40mm nominal bore including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking of pipes within 50 metres lead, etc., all complete as directed by the Engineer-in-Charge. 50.00 R m #NAME? 0.00
76 Taking out CI cover with frame from RCC top slab of inspection chambers of various sizes including demolishing of RCC work manually / by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead, etc., all complete as directed by the Engineer-in-Charge. 2.00 Each #NAME? 0.00
77 Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead / to the maintainance dept / stores, etc., all complete as directed by the Engineer-in-Charge. 32.00 Sq m #NAME? 0.00
78 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50m initial lead, for all leads including all lifts involved, etc., all complete as directed by the Engineer-in-Charge. 330.00 Cu m #NAME? 0.00
79 Providing and laying design mix cement concrete of M-30 grade, in roads / taxi tracks / runways, hard standing using cement content as per design mix, Cement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transit mixer using coarse sand and graded stone aggregate of approved nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve / tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope / camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10mm wide x 50mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, etc., all complete as directed by the Engineer-in-Charge. (Item of joint fillers, sealants, dowel bars with sleeve / tie bars to be paid separately). 162.00 Cu m #NAME? 0.00
80 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints/construction joints in roads / pavements / floorings / hard standings, etc., all complete as directed by the Engineer-in-Charge. [To be applied only in Non PU Flooring and Granite/Vitrifed Floor Area]. 232.79 per 1cm X 5cm depth per m length #NAME? 0.00
81 Supplying, Laying and compacting of granular sub-base in flooring, subbases, ramps, etc., upto plinth level of requisite grading by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, etc., all complete as per specifications and directions of Engineer-in-Charge. 206.00 Cu m #NAME? 0.00
82 Taking out existing kerb stones of all types from footpath / central verge, including removal of mortar, etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead, etc., all complete as directed by the Engineer-in-Charge. 66.00 R m #NAME? 0.00
83 Providing and fixing White Vitrious China Wash Basin of size round [630 X 450]mm with C.I. brackets / fastners, 15mm C.P. brass pillar tap [Quarter turn with aerator for taps], 32mm CP brass waste of standard pattern, 32mm dia semi-rigid PVC waste pipe including fittings and brackets, cutting and making good the walls, connecting to floor trap and with all necessary fittings and accessories, etc., wherever required, etc., all complete as directed by the Engineer-in-Charge. 5.00 Each #NAME? 0.00
84 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings, along with all the necessary fittings, fixtures and other accessories including PVC waste fitiings,PVC semi rigid type waste pipe, etc., all complete as directed by the Engineer-in-Charge. 5.00 Each #NAME? 0.00
85 Providing and fixing, testing and commissioning 8mm dia CP / SS Jet (health faucet) with flexible tube upto 1 metre long with SS triangular plate to Eureopean type WC of quality and make as approved with necessary fittings, etc., all complete as directed by the Engineer-in-Charge. 6.00 Each #NAME? 0.00
86 Providing and fixing of toilet paper holder of CP brass type, etc., all complete as directed by the Engineer-in-Charge. 6.00 Each #NAME? 0.00
87 Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms, etc., all complete as directed by the Engineer-in-Charge. 5.00 Each #NAME? 0.00
88 Providing and fixing white vitreous china extended wall mounting water closet of size around [780 x 370 x 690]mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre / 6 litre (adjustable to 4 litre / 8 litres), including seat cover and cistern fittings, nuts, bolts and gasket, etc., all complete as directed by the Engineer-in-Charge. 6.00 Each #NAME? 0.00
89 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approximate size [610 x 390 x 370]mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets embedded in cement mortar (1:3), connecting the waste pipe to floor trap with all necessary fittings and accessories like 32mm dia semi-rigid PVC waste pipe (concealed in the wall) including PVC waste fittings, clamps, etc., all as per manufacturers specification and direction of Engineer-in-Charge. 2.00 Each #NAME? 0.00
90 Providing and fixing trap of self cleansing design with screwed down or hinged with 100mm dia SS grating of approved deisgn complete for including cost of cutting and making good the walls and floors, etc., all complete as directed by the Engineer-in-Charge. 9.00 Each #NAME? 0.00
91 Providing and fixing trap of self cleansing design with screwed down or hinged 100mm to 75mm dia SS grating of approved deisgn complete for including cost of cutting and making good the walls and floors, etc., all complete as directed by the Engineer-in-Charge. 8.00 Each #NAME? 0.00
92 Providing and fixing Concealed Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, fixing the pipe with clamps at 1.00m spacing, necessary reducers, tank adaptors etc. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints and making good the walls, etc., all complete as directed by the Engineer-in-Charge.
a) 15mm dia 48.00 R m #NAME? 0.00
b) 20mm dia 50.00 R m #NAME? 0.00
c) 25mm dia 15.00 R m #NAME? 0.00
93 Providing and fixing 25mm dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints, etc., all complete as directed by the Engineer-in-Charge. 40.00 R m #NAME? 0.00
94 Supplying, jointing, testing and commissioning, approved make 25mm dia GM body gate valves with C.I wheel and screwed ends, etc., all complete as directed by the Engineer-in-Charge. 6.00 Each #NAME? 0.00
95 Providing and fixing of ball valve (brass) 25mm nominal bore dia, of approved quality, High or low pressure, with plastic floats, screwed for iron pipe or brass ferrule and fixed,including necessary fittings i.e flynut, etc., all complete as directed by the Engineer-in-Charge. 4.00 Each #NAME? 0.00
96 Providing and placing in position at terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes along with necessasry accessories, etc., all complete as directed by the Engineer-in-Charge. 3000.00 Per litre #NAME? 0.00
97 Providing and fixing PTMT angle stop cock 15mm nominal bore [With aerator], weighing not less than 85 gms fixed to the health faucet, etc., all complete as directed by the Engineer-in-Charge. 5.00 Each #NAME? 0.00
98 Providing and fixing C.P. brass bib cock of 15mm nominal bore dia [Quarter turn with aerator] and approved quality conforming to IS:8931, etc., all complete as directed by the Engineer-in-Charge. 6.00 Each #NAME? 0.00
99 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour, etc., all complete as directed by the Engineer-in-Charge.
a 20mm dia 8.00 Each #NAME? 0.00
b) 25mm dia 4.00 Each #NAME? 0.00
100 Providing and laying non-pressure NP2 class (light duty) 300mm dia RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints, etc., all complete as directed by the Engineer-in-Charge. 2.50 R m #NAME? 0.00
101 Constructing brick masonry manhole in with inside size of [120 X 90]cm and 90cm deep including CI cover with frame (Medium Duty) 500mm internal diameter, total weight of cover and frame not less than 116 kgs (weight of cover 58 kgs and weight of frame 58 kgs) built with Burnt Brick of class designation 7.5 with cement mortar 1:4 (1 cement : 4 coarse sand) with foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design, etc., all complete as directed by the Engineer-in-Charge. 2.00 Each #NAME? 0.00
102 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12mm dia steel bar conforming to IS: 1786, having minimum cross section as [23 x 25]mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in Water Tanks / Manholes with [30 x 20 x 15]cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design, etc., all complete as directed by the Engineer-in-Charge. 15.00 Each #NAME? 0.00
103 Providing and fixing in position pre-cast RCC manhole cover and frame Light Duty Rectangular in shape [600 X 450]mm internal dimentions and of approved quality, etc., all complete as directed by the Engineer-in-Charge. 2.00 Each #NAME? 0.00
104 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain, etc., complete for pipes of 100 to 250mm diameter, etc., all complete as directed by the Engineer-in-Charge. 2.00 Each #NAME? 0.00
105 Constructing brick masonry chamber for underground CI inspection chamber and bends Inside dimensions [455 X 610]mm and 45cm deep for pipe line with three or more inlets with common burnt clay FPS (non modular) bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) [455 x 610]mm internal dimensions, total weight of cover with frame to be not less than 38 kgs (weight of cover 23 kgs and weight of frame 15 kgs), RCC top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete, etc., complete as per standard design, etc., all complete as per the drawings and the directions of Engineer-in-Charge. 2.00 Each #NAME? 0.00
106 Providing, fabricating and fixing aluminium work for partitions, Curtain wall frames, flats, covers, Ventilators, Windows, louvers, doors, etc., frame work. (Min. thickness of powder coating 50 microns) made up of aluminium extruded sections in fixed position. Ventilators: conforming to designaton 63400 of IS 1285 and of approved make, partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, The glazing and prelaminated particle board shall be fixed with tapered aluminium interlocking screwless snap on type glazing clip not less than 0.90mm thick. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, CP brass / stainless steel screws, etc., all complete as per architectural drawings and the directions of Engineer-in-Charge. (Glazing, Panelling, fly proof mesh will be paid seperately). 585.60 Kgs #NAME? 0.00
107 Aluminium work for shutters of doors i.e Powder coated Aluminium Door Frames (minimum thickness of powder coating 50 micron) & ventilators in moving position including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required including necessary accessories, etc., all complete as per the architectural drawings and the directions of Engineer-in-Charge. 403.00 Kgs #NAME? 0.00
108 Providing and fixing glazing in aluminium door, window, ventilator, Louvers, shutters and partitions, etc., With float glass panes of 5mm thickness (weight not less than 12.50 kg/Sq m) along with EPDM rubber / neoprene gasket, etc., all complete as per the architectural drawings and the directions of Engineer-in-Charge. 134.05 Sq m #NAME? 0.00
109 Providing and laying integral cement based water proofing treatment With average thickness of 120mm and minimum thickness at khurra as 65mm including preparation of surface as required for treatment of roofs: (a) Applying a slurry coat of neat cement using 2.75 kg/Sq m of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-Charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks / brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge over 20mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/Sq m of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge. (d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of [300 x 300]mm square 3mm deep. 392.00 Sq m #NAME? 0.00
(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge. Note: (i) A performance guarantee bond for 5 years on non-judicial stamp paper of Rs. 500/- shall be given by the contractor. The 10% of completed value of this item shall be dedcuted as defect liability deposit and the same shall be returned after sucessful completion of 5 years from the date of completion of contract / project as a whole. (ii) Plan area shall be measured for payment. (iii) The quoted rate shall be for the entire work and nothing extra shall be paid on this account.
110 Supplying, filling, spreading & leveling stone boulders of size range 5cm to 20cm, below footings/ in floors / in recharge pit, in the required thickness, for all leads & lifts, etc., all complete as directed by the Engineer-in-Charge. 20.00 Cu m #NAME? 0.00
111 Supplying, filling, spreading and levelling Gravels of size range 5mm to 10mm in recharge pit over the existing layer of boulders in the required thickness for all leads and lifts, etc., all complete as directed by the Engineer-in-Charge. 1.00 Cu m #NAME? 0.00
112 Supplying, filling, spreading and levelling coarse sand of size range 1.50mm to 2mm in recharge pits, in the required thickness over gravel layer for all leads and lifts, etc., all complete as directed by the Engineer-in-Charge. 1.00 Cu m #NAME? 0.00
113 Providing and fixing false ceiling with 15mm thick Tegular edged light weight calcium sliciate false ceiling tiles or Mineral Fibre Tiles at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size [595 x 595]mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick(galvanized @ 120 grams per Sq m including both sides) comprising of main-T runners of size [24 x 38]mm of length 3000mm, cross - T of size [24 x 32]mm of length 1200mm and secondaryintermediate cross-T of size [24 x 32]mm of length 600mm to formgrid module of size [600 x 600]mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per Sq m) i.e. [12 x 50]mm long dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size [76 x 25 x 25 x 1.60]mm fixed with grid and Z cleat of size [25 x 37 x 25 x 1.60]mm thick with precut hole on both 25mm flange to pierce into [12 x 50]mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size [24 x 24 x 0.40]mm of length 3000mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 1425.30 Sq m #NAME? 0.00
114 Providing and laying factory made Precast concrete solid blocks of 200 mm thickness of grade M10 made of Normal resources / C & D Waste from approved manufacturer in superstructure above plinth level up to floor V level built in CM (1:6), etc., all complete as directed by the Engineer-in-Charge. 367.00 Cu m #NAME? 0.00
115 Providing and fixing factory made 18mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer numeric control) routed of approved design by Engineer- in- Charge which are machine cut for duct / shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium corbonate and natural fibers (wood powder / rice husk / wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/Cu m and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water / moisture proof and fire retardant and fixing on M.S (mild steel) frame made of [25 x 25 x 1.50]mm square hollow box section including applying a priming coat of approved steel primer, placed at grid made at [1.0 x 1.0]m or as per requirement at site with necessary stainless steel fasteners and SS screws, etc., all complete as directed by Engineer-in- Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately. 60.00 Sq m #NAME? 0.00
116 Supplying and fixing terracotta external wall tiles of approved colour & pattern, laid with cement based high polymer modified quick set tile adhesive (Water based) conforming to IS 15477, in average 3mm thickness and pointed with epoxy grout of approved colour, including roughening the surface, curing, etc., all complete as directed by the Engineer-in-Charge. 135.00 Sq m #NAME? 0.00
117 Providing and fixing of Motoorized G.I Rolling Shutter of approved make and made to required size For Opening of Size around [3.0 X 3.50]m. The curtain shall be constructed from Tata Bluescope / JSW 150gsm single skinned galvalume steel laths with natural finish of min 1.25mm thickness and interlocking distance of min 75mm. Side guides shall be made of min 2 to 3.15mm thick heavy duty TG galvanised steel, as per site requirment, along with necessary fixtures like cleats (spacing shall not exceed 0.75m) or suupports brackets for attachments to the walls or columns by screws or bolts and necessary seals. The size of the guide channels shall be confirming to IS: 6248-1979. Single piece G.I Heavy, etc., all complete as directed by Engineer-in-Charge. Note:- Clear Opening Size will be measured for payment. The quoted rate shall be for the entire work and making it operational. 10.35 Sq m #NAME? 0.00
118 Providing and fixing of Motoorized G.I Rolling Shutter of approved make and made to required size. For Opening of Size around [4.50 X 4.50]m. The curtain shall be constructed from Tata Bluescope / JSW 150gsm single skinned galvalume steel laths with natural finish of min 1.25mm thickness and interlocking distance of min 75mm. Side guides shall be made of min 2 to 3.15mm thick heavy duty TG galvanised steel, as per site requirment, along with necessary fixtures like cleats (spacing shall not exceed 0.75m) or suupports brackets for attachments to the walls or columns by screws or bolts and necessary seals. the size of the guide channels shall be confirming to IS: 6248-1979. Single piece G.I Heavy, etc., all complete as directed by Engineer-in-Charge. Note:- Clear Opening Size will be measured for payment. The quoted rate shall be for the entire work and making it operational. 41.00 Sq m #NAME? 0.00
119 Providing and fixing of Motoorized G.I Rolling Shutter of approved make and made to required size. The curtain shall be constructed from Tata Bluescope / JSW 150gsm single skinned galvalume steel laths with natural finish of min 1.25mm thickness and interlocking distance of min 75mm. Side guides shall be made of min 2 to 3.15mm thick heavy duty TG galvanised steel, as per site requirment, along with necessary fixtures like cleats (spacing shall not exceed 0.75m) or suupports brackets for attachments to the walls or columns by screws or bolts and necessary seals. the size of the guide channels shall be confirming to IS: 6248-1979. Single piece G.I Heavy, etc., all complete as directed by Engineer-in-Charge. Note:- Clear Opening Size will be measured for payment. The quoted rate shall be for the entire work and making it operational. Approx.Size of Opening : [6.0 X 6.0]m 75.60 Sq m #NAME? 0.00
120 Providing and fixing factory made 3 track UPVC glazed wire mesh windows comprising of lead free UPVC multi-chambered frame, shash and mullion coupler (wherever required) extruded profiles having minium wall thickness of 1.50mm and up to 2.10mm for using R3 series with frame approx. size of 98mm & above up to 112mm X 40mm & above and upto 52mm or nearest available both glased and fly scren sash approx. size of (55mm & above and upto 66mm) X (30mm & above up to 43mm) including all fxitures and fitting, etc., all complete as directed by Engineer-in-Charge. 75.80 Sq m #NAME? 0.00
121 Providing and fixing of 6mm thick Tough121ned Glass in glazing for aluminium / UPVC doors, windows, partitions, etc., at all heights with EPDM rubber / neoprene gasket and necessary packing material, etc., all complete as per the drawings / site requirments and directions of Engineer-in-Charge. Note:-Frosted flim to be provided wherever required) 93.00 Sq m #NAME? 0.00
122 Trussless Roof System: Deisgning, supplying and laying of Trussless Roofing comprising of min 1.25mm thick Prepainted Galvalume Sheeting consiting of min 1.20mm thick Bare Metal Thickness (BMT) for span of approx.19.60m and arch.rise of approx.3.92m at a height of approx.16.20m. The Base material shall confirm to ASTM A792M with coating mass of AZM 150 and min yield strength of 350 MPa including consumables like anchor fastners, washers, epoxy paint lacquer, etc., all complete for the entire system. The intersection at the gable end system and roof shall be provided with flashing sheet of suitable deisgn. Note:- the Truss Less Roofing System shall be provided with Hooks at every 1.20m for supporting the false ceiling load of approx.10kg/Sq m. 851.00 Sq m #NAME? 0.00
123 Profiled Sheeting gable Cladding: Deisgning, supplying and fixing of gable end cladding system for the Truss Less Roof System. The end cladding sheet shall be made out of Pre-painted Galvalume Sheet of min Total Coated Tickness of 0.85mm and Bare Metal Thickness of 0.8mm confirming to IS 15961 with coating mass of AZM 150 with min yield strength of 350 MPa. The send system shall be fixed with frame work made out of MS tubular structure. The structural elements will be paid seperately. 115.00 Sq m #NAME? 0.00
124 PU Flooring: Providing and applying seamless, jointless 3-4mm thick Heavy Duty Polyurethane Concrete Floor Topping comprising with High Resistance to arresive chemicals over the prepared floor surface including cleaning, moisture testing and scarifying and other suitable surface preparation. Surface Preparation: Existing surface substratemust be prepared mechanically using scarifying or grinding equipment to remove cement laitance and acheive an open textured surface. Weak Concrete must be removed and surface defects such as blowholes and voids must be fully exposed. Repairs: Repairs to the substrate, filling of blow holes/voids and surface levelling must be carried out using appropriate repair product. It must be ensured that the moisture content of surface is below 4%./as per manufacturer specification. New concrete or cement substrate on which the system is likely to be applied should be 28 days old and have moisture content less than 4%. Priming: The prepared surface to be primed with 1mm thick Smooth protective polyurethane scratch coat as per manufacturers specification and coverage. Over Coat: Application of 3mm top HPU on the proime surface and spread uniformly with anotched trowel: care shoould be taken not to over work the resign. After spreading immediately the floor should be firmly rolled taking care to avoid pounding. Applying the material around the edges of areas and into grooves. The floor topping to acheive a compressive strength of approx. 40 n/mm2 (BS 6319) and the tesnsile strength after curing approx.8n/mm2 (IS 9162) : Flexurale strength : approx. 21 N/mm2 ( IS 9162). 648.00 Sq m #NAME? 0.00
125 Supplying, laying, testing and commissioning the following dia PVC pipes of 6 kg/cm2 SWR grade and of approved make (Supreme or Finolex) with rubber ring loints conforming to lS 5382, jointed together with solvent, in trenches and floors, including all necessary fittings & specials, bends, branches, sockets, pipe cutting and wastages, cuttlng and making good the floors, etc., all complete as directed by the Engineer-in Charqe.
a) 75mm dia 10.00 R m #NAME? 0.00
b) 110mm dia 60.00 R m #NAME? 0.00
126 Providing and fixing bright flnished brass handles of 200mm size with screws, etc., all complete as directed by the Engineer-in-Charge. 4.00 Each #NAME? 0.00
Sub Total of Part 'I' - Civil Works #NAME? 0.00
Part 'II A' - Electrical Works
Totally type tested panels(TTA)
1 Supply, Installation, Testing & commissioning of indoor type Main LT TTA Panel. 1.00 Each #NAME? 0.00
Design, fabrication, supply, installation, testing and commissioning of the following Indoor type Modular construction TTA (Totally Type tested Assemblies) Switch Board as per IEC 61439- Part-I & II for Voltages up to 1100 V, degree of protection shall be IP-42, suitable to be mounted on the floor/cable duct as per site requirement including supply & fixing/grouting M.S channel frame work for erection of panel, with cable entry from bottom/top as per drawing coordination by EIC conforming to technical specification complete.
Note:-1)a) All ACB's in the LT panels shall be Manually drawout(MDO)/Electrical drawout(EDO) type as specified. Air Circuit breaker of approved make suitable for 415V 3 Ph & N supply with microprocessor based tripping device comprising of overload, short circuit and instantaneous ground fault protection(LSIG) including suitable range CTs and separate LED indications for overload, short circuit and ground fault along with release and also micro switches for service, isolated and locking positions for the breaker, door interlock, secondary isolating contacts, auxiliary contacts as required including ON/OFF indications, trip push button, trip indication, front operating handle and other connected accessories complete in all respects. b) All ACB's should be rated for minimum 50KA breaking capacity as detailed in BOQ (Icu=Ics=Icw for 1sec)
2)The operating height of the Panel shall not exceed 2.1 mtr. from FFL.
3)Aluminium bus bar size for carriying out specified current shall be as per type test certificate.
4)All MCCBs 400A & above shall be with Micro processor based and below 400A shall be adjustable with thermal settings(80% to 100%), overload and short circuit releases including door interlocking device, front operating handle complete,ON and OFF indication of LED indication lamps etc., complete in all respects.
i) 1No - 2000A, 415V gr. 50KA, 4P EDO Type ACB
ii) Lot - 2500A TP + N, 415V, short circuit rated 50KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
iii) 1No - Multi function meter (MFM/MDM)suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1,RS 485 Port Digital MFM/MDM of power logic PM2230 of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
iv) 1Set of - 2000/5A current transformers of class 1 and suitable burden for metering.
v) 1No - (0-500V) range 96x96mm flush type analog voltmeter with RYB selector switch
vi) 1No 6A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
vii) 1Set - RYB indicating lamps of LED module with 6A SP MCB.
viii) 1Set- 6A, MCB for the protection of measuring instruments.
i) 1 No - 1000 A 415V gr. 50KA, TP+NL MDO Type ACB
ii) 2 Nos - 800 A 415V gr. 50KA, TP+NL MDO Type ACB
iii) 4Nos - 200A, 415V gr. 50KA, TP+NL MCCB
2 Partially type tested panels(PTTA)
Design, fabrication, supply, installation, testing and commissioning of cubicle type Indoor LT Panel with front lockable door arrangement, suitable to be mounted on the existing brick pedestal/cable duct inlcuding M.S channel frame work, with cable entry from bottom/top with removable gland plates with required knock-outs, panel fabricated out of CRCA sheet steel folded and braced as necessary to provide a rigid support for all components, totally enclosed, dust and vermin proof and degree of protection shall not be less than IP-54, multi-tier cubicle type formation with front hinged lockable doors for the individual feeders/ compartments, preparation of surface and treatment by seven tank process, powder coated with approved colour for not less than 50 microns and all doors and covers shall be fully gasketed using good quality EPDM gasket and/or rubber strips and ensure good lockable, durable door opening & closing mechanism, suitable meshed ventilator louvers with suitable cover,canopy type covering and Aluminium bus bars for three phases and neutral, bus bar insulators, heat shrinkable PVC sleeves etc., with necessary interconnections as specified in Technical specifications for electrical & mechanical works, comprising of following switchgear and accessories complete in all respects and as directed by Engineer-in-charge.
1)a) All ACB's in the LT panels shall be Manually drawout(MDO)/Electrical drawout(EDO) type as specified. Air Circuit breaker of approved make suitable for 415V 3 Ph & N supply with microprocessor based tripping device comprising of overload, short circuit and instantaneous ground fault protection(LSIG) including suitable range CTs and separate LED indications for overload, short circuit and ground fault along with release and also micro switches for service, isolated and locking positions for the breaker, door interlock, secondary isolating contacts, auxiliary contacts as required including ON/OFF indications, trip push button, trip indication, front operating handle and other connected accessories complete in all respects. b) All ACB's should be rated for minimum 50KA breaking capacity as detailed in BOQ (Icu=Ics=Icw for 1sec)
2) Current density shall not exceed 0.8A/sq.mm for Aluminium bus bars in LT Panel
3)The operating height of the Panel shall not exceed 2.1 mtr. from FFL.
2.1 Supply, Installation, Testing & commissioning of Indoor type HVAC LT PTTA Panel. 1.00 Each #NAME? 0.00
i) 1No - 1000A, 415V gr. 50KA, 4P EDO Type ACB
ii) Lot - 1000A , 415V, short circuit rated 50KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
iii) 1No- Multi function meter (MFM/MDM)suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1,RS 485 Port Digital MFM/MDM of power logic PM2230 of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
iv) 1Set of - 1000/5A current transformers of class 1 and suitable burden for metering.
v) 1No- (0-500V) range 96x96mm flush type analog voltmeter with RYB selector switch
vi) 1No 6A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
vii) 1Set - RYB indicating lamps of LED module with 6A SP MCB.
viii) 1Set- 6A, MCB for the protection of measuring instruments.
i) 3Nos - 200A, 415V gr. 50KA breaking capacity, TP+NL MCCB
ii) 4Nos - 160A, 415V gr. 50KA breaking capacity, TP+NL MCCB
iii) 4Nos - 80A, 415V gr. 50KA breaking capacity, TP+NL MCCB
iv) 2Nos - 63A, 415V gr. 50KA breaking capacity, TP+NL MCCB
v) 3Nos - 63A, 415V gr. 10KA breaking capacity, TPN MCB
vi) 5Nos - 40A, 415V gr. 10KA breaking capacity, TPN MCB
2.2 Supply, Installation, Testing & commissioning of UPS Output LT PTTA panel. 1.00 Each #NAME? 0.00
i) 2Nos - 800A, 415V gr. 50KA, 4P EDO Type ACB
1No - 800A, Four Pole, Automatic transfer switch with controller
ii) Lot - 1000A TP + 500A N, 415V, short circuit rated 50KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
iii) 2No- Multi function meter (MFM/MDM)suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1,RS 485 Port Digital MFM/MDM of power logic PM2230 of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
iv) 2Sets of - 800/5A current transformers of suitable class and VA burden for metering.
v) 2No - (0-500V) range 96x96mm flush type analog voltmeter with RYB selector switch
vi) 2 Nos 13A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
vii) 2Set - RYB indicating lamps of LED module with 6A, 230V,10KA, SP MCB.
viii) 2Set- 6A, 230V, 10KA SP MCB for the protection of measuring instruments.
i) 2Nos - 200A, 415V gr. 50KA breaking capacity, TP+NL MCCB
ii) 4Nos - 80A, 415V gr. 50KA breaking capacity, TP+NL MCCB
iii) 4Nos - 63A, 415V gr. 50KA breaking capacity, TP+NL MCCB
iv) 2Nos - 63A, 415V gr. 10KA breaking capacity, TPN MCB
v) 4Nos - 63A, 415V gr. 10KA breaking capacity, DP MCB
vi) 6Nos - 32A, 415V gr. 50KA breaking capacity, TP+NL MCCB
vii) 2Nos - 32A, 415V gr. 10KA breaking capacity, TPN MCB
3 Supply, Installation, Testing & commissioning of Timer panel (IEC 60439 standard PTTA panel) (Outdoor type) 1.00 Each #NAME? 0.00
Design, fabrication, supply, installation, testing and commissioning of the following weatherproof cubicle type Outdoor LT Panels with front lockable door arrangement, mounted on the floor/cable duct/with MS stand as per site requirement using MS angle/channel frame work including supply, fixing & painting of suitable size M.S angle/channel iron frame work, with cable entry from bottom with removable gland plates with required knock-outs, panel fabricated out of CRCA sheet steel folded and braced as necessary to provide a rigid support for all components, totally enclosed, dust and vermin proof and degree of protection shall not be less than IP-55, multi-tier cubicle type formation with front hinged doors lockable doors for the individual feeders/compartments, preparation of surface and treatment by seven tank process, powder coated with approved colour for not less than 50 microns, with front lockable door(Double leaf), and all doors and covers shall be fully gasketed using good quality EPDM gasket and/or rubber strips and ensure good lockable, durable door opening & closing mechanism, suitable meshed ventilator louvers with suitable cover, canopy type top cover to avoid rainwater collection/entry, Aluminium bus bars for three phases and neutral, bus bar insulators, heat shrinkable PVC sleeves etc., with necessary interconnections as specified in Technical specifications for electrical & mechanical works, comprising of following switchgear and accessories complete in all respects and as directed by Engineer-in-charge.
1)(i)All the MCBs shall be suitable for inductive loads and Lighting load. ii)All MCBs shall have overload and short circuit releases. iii) All MCBs shall be rated for 10kA breaking capacity, C curve.
i) 1no - 32A 415V gr TPN 10KA, MCB
ii) 1No- Modular digital time switch for street light/Building light control of Legrand Alpha Rex 3 D21 or equivalent approved make with two channel daily cycle unit suitable for daily programming to switch ON & OFF and operate on 230V single phase supply.
iii) 1No-25A, Modular type Power contactor with suitable NO & NC to operate on 230V Single phase supply.
i) 2Nos - 16A 415V gr. 10KA SP MCB
ii) 1No - 10A 415V gr. 10KA SP MCB
Uninterrupted Power supply(UPS)
4 Supplying, installation, Testing & Commissioning of 400kVA capacity at full load (Unity Power Factor) at operating temperature 0 to 40oC, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be <5% at 50 %load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power
factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. . Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance.
The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display /LED) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage. f) Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. As per CPWD Specification. 1.00 Each #NAME? 0.00
Light fixtures, fans and exhaust fans
5 Supply, fixing to existing MS perlins/MS truss/Truss less roof system at approx. 16-18 mtr height using suitable MS angle frame work with required fixing hardwares etc., as per site requirement, testing & commissioning of industrial type highbay LED lighting fixture of wattage not exceeding 200watts made out of high pressure diecast aluminium housing, diffuser made of high grade toughened glass, integral control gear, eye hook etc., (as per OEM standards). The technical parameters of lighting fixtures are as below: The luminaire should have Lumen efficacy ≥ 160lm/watt and lumen output not less than 32000 lumens, PF>0.90 and Colour temprature shall be ≥5700K, CRI≥70, THD <10%, IP66/65, minimum 50000 Burning Hours, Minimum 5 year OEM warranty and operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures and other standard accessories complete in all respects and as directed by Engineer in-charge. The fitting may be of Bajaj model no: Novabay 200W WH NB PC SD XE/ Equivalent model in other approved makes. LED used in the lighting fixtures should be one of the approved make. LM79 certification for luminares & LM80 certificate for LED shall be produced. 20.00 Each #NAME? 0.00
6 Supply, fixing to existing MS perlins/MS Truss at approx. 8-10 mtr height, including using suitable MS angle frame work with required fixing hardwares etc., as per site requirement, testing & commissioning of industrial type highbay LED lighting fixture of wattage not exceeding 100watts made out of high pressure diecast aluminium housing, diffuser made of high grade toughened glass, integral control gear, eye hook etc., (as per OEM standards). The technical parameters of lighting fixtures are as below: The luminaire should have Lumen efficacy ≥ 160lm/watt and lumen output not less than 16000lumens, PF>0.90 and Colour temprature shall be ≥5700K, CRI≥70, THD <10%, IP66/65, minimum 50000 Burning Hours, Minimum 5 year OEM warranty and operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures and other standard accessories complete in all respects and as directed by Engineer in-charge. The fitting may be of Bajaj model no: Novabay 100W WH NB PC SD XE/ Equivalent model in other approved makes. LED used in the lighting fixtures should be one of the approved make. LM79 certification for luminares & LM80 certificate for LED shall be produced. 6.00 Each #NAME? 0.00
7 Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of Extruded aluminium Body(Thickness > 1.20 mm) material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). As per CPWD Specification. 78.00 Each #NAME? 0.00
8 Supplying, installation, Testing & Commissioning of following wattage LED Recessed/surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with river as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim. As per CPWD Specification.
a) 6 Watt 9.00 Each #NAME? 0.00
b) 15 Watt 6.00 Each #NAME? 0.00
c) 18 Watt 70.00 Each #NAME? 0.00
9 Supplying, installation, Testing & Commissioning of following wattage LED surface mounted Batten light of Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). As per CPWD Specification.
a) 40 Watt 15.00 Each #NAME? 0.00
b) 20Watt 10.00 Each #NAME? 0.00
10 Supplying, installation, Testing & Commissioning of 72W Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Supply, fixing & bending to shape as per site requirement of suitable dia Class B GI pipe on the wall including necessary acccessories for installation of light fixture as per E-I-C. As per CPWD Specification. 12.00 Each #NAME? 0.00
11 Supply & fixing above the building using min 1500mm long 20mm dia class B GI pipe including necessary fixing harware, testing and commissioning of outdoor type 10W LED aviation light. The light fixture may be of Bajaj make and model no: BGAV 302 LED or equivalent in other HAL approved makes including necessary interconnections complete in all respects as directed by E-I-C. 2.00 Each #NAME? 0.00
12 Supply, Installation, Testing and Commissioning of 1200mm Sweep ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, suitable length down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/Min/Watt) > 6.0, minimum air delivery 210CM/Min, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. As per CPWD Specification. 6.00 Each #NAME? 0.00
13 Supply, installation, testing & commissioning of 300mm dia 900 rpm heavy duty exhaust fan of any approved make with louvers, connecting cord with 6A, 3 pin plug top and with all necessary accessories, including making wall openings and replastering to smooth finish with matching paint etc., complete in all respects and as directed by Engineer-in-charge. 5.00 Each #NAME? 0.00
14 Supply and fixing of weather proof cable junction box with terminals of size 104 mm x 104 mm x 70 mm Hensel Cat. No. DK 0402G or equivalent in Legrand/ Schneider/ Hagar make only. The Box shall be mounted on the wall/truss using suitable size MS angle frame work with painting as per EIC, with cable entry knock-outs, including rigid support for all components, Din channel, required fasteners totally enclosed, dust and vermin proof and degree of protection shall not be less than IP-65 complete in all respects and as directed by Engineer-in-charge. 40.00 Each #NAME? 0.00
15 Supplying, Installation, Testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 3 meter and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. As per CPWD Specification. 6.00 Each #NAME? 0.00
16 Supplying, Installation, Testing and commissioning of Microwave technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 3 meter and for 5m X 20m coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. As per CPWD Specification. 6.00 Each #NAME? 0.00
17 Distribution Boards
Supply, fixing, testing & commissioning of the following factory built powder coated Double door MCB/MCCB DB of any approved make fabricated out of M.S. sheet steel enclosure & necessary cutouts for operating the MCB knobs & comprising of 200 amps tinned copper busbars & earthing bus with tapped holes including internal wiring with stranded copper PVC wires or suitable size copper strips etc. & fixing the DB in flush with wall/ on wall as per site requirement including with necessary M.S. angle supports, chipping the wall and replastering to smooth finish etc., wherever required as per site condition, complete in all respects, as directed by Engineer-in-charge and comprising the following as detailed below:
a) 8way VTPN MCCB DB. 1.00 Each #NAME? 0.00
b) 6way VTPN MCCB DB. 4.00 Each #NAME? 0.00
c) 6 way HTPN MCB DB 4.00 Each #NAME? 0.00
d) 4 way HTPN MCB DB 5.00 Each #NAME? 0.00
18 MCCBs, MCBs & RCBO
Supply, fixing, testing & commisisoning of following rating MCCB/MCB/RCBO in the existing Distribution board/powder coated enclosure as directed by Engineer-in-Charge.
a) 200A, 25KA, FP 415V, MCCB 1.00 Each #NAME? 0.00
b) 63-100A, 25KA, FP 415V, MCCB 4.00 Each #NAME? 0.00
c) 40-63A, FP MCB, 10kA, C Curve 11.00 Each #NAME? 0.00
d) 25-32A, FP MCB, 10kA, C Curve 2.00 Each #NAME? 0.00
e) 40-63A TP MCB, 10kA, C Curve 7.00 Each #NAME? 0.00
f) 5A to 32A TP MCB 10kA , C Curve 8.00 Each #NAME? 0.00
g) 5A to 32A SP MCB 10kA , C Curve 190.00 Each #NAME? 0.00
19 Supply, installation(surface/recess), testing and commissioning of 2/3/4 Way Powder coated Enclosure with provision to mount MCB/RCCB/RCBO and other modular devices complete in all repects and as per Engineer in Charge. 4.00 Each #NAME? 0.00
20 Supply, laying, testing & commissioning of following size Aluminium LT armoured power cables.
Supply & laying in the already excavated cable trench/cable tray/fixing on wall/duct wall with necessary M.S clamps / encasing in pipes etc., testing & commissioning of following size XLPE insulated Aluminium (Al) conductor(stranded) 1.1 KV grade confirming to IS: 7098 ( part-I)/1998 with upto date amendment earthed Armoured (Arm)U.G cables and as per technical specification including stacking at site, proper storage complete etc., as required. (Note:- Excavation, sand & Brick Protection, concrete cutting, reconcreting, casing pipes will be measured separately.)
a) 3.5CX 300 Sqmm Aluminium armoured conductor 950.00 Mtrs #NAME? 0.00
b) 3.5CX 240 Sqmm Aluminium armoured conductor 60.00 Mtrs #NAME? 0.00
c) 3.5CX 120 Sqmm Aluminium armoured conductor 170.00 Mtrs #NAME? 0.00
d) 3.5CX 70 Sqmm Aluminium armoured conductor 300.00 Mtrs #NAME? 0.00
e) 3.5CX 25 Sqmm Aluminium armoured conductor 125.00 Mtrs #NAME? 0.00
f) 4CX 16 Sqmm Aluminium armoured conductor 70.00 Mtrs #NAME? 0.00
g) 4CX 10 Sqmm Aluminium armoured conductor 60.00 Mtrs #NAME? 0.00
21 Supply, laying, testing & commissioning of following size Copper LT armoured power cables.
Supply & laying in the already excavated cable trench/cable tray/fixing on wall/duct wall with necessary M.S clamps / encasing in pipes etc., testing & commissioning of following size XLPE insulated Copper (cu) conductor 1.1 KV grade confirming to IS: 7098 (part-I)/1998 with upto date amendment earthed Armoured (Arm)/un Armoured (un Arm) U.G cables and as per technical specification including stacking at site, proper storage complete etc. as required. (Note:- Excavation, sand & Brick Protection, concrete cutting, reconcreting, casing pipes will be measured separately.)
a) 4C X 25 Sqmm Copper armoured conductor LT Cable 150.00 Mtrs #NAME? 0.00
b) 4C X 16 Sqmm Copper Unarmoured conductor LT Cable 50.00 Mtrs #NAME? 0.00
c) 4C X 10 Sqmm Copper armoured conductor LT Cable 60.00 Mtrs #NAME? 0.00
d) 4C X 6 Sqmm Copper armoured conductor LT Cable 440.00 Mtrs #NAME? 0.00
e) 3C X 2.5 Sqmm Copper armoured conductor LT control Cable 850.00 Mtrs #NAME? 0.00
22 Supply, laying, testing & commissioning of following size Copper LT Unarmoured power cables.
Supply & laying in the already excavated cable trench/cable tray/fixing on wall/duct wall with necessary M.S clamps / encasing in pipes etc., testing & commissioning of following size XLPE insulated Copper (cu) conductor 1.1 KV grade confirming to IS: 7098 (part-I)/1998 with upto date amendment earthed un Armoured (un Arm) U.G cables and as per technical specification including stacking at site, proper storage complete etc. as required. (Note:- Excavation, sand & Brick Protection, concrete cutting, reconcreting, casing pipes will be measured separately.)
a) 1C X 300 Sqmm Copper Unarmoured conductor LT cable 230.00 Mtrs #NAME? 0.00
23 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE armoured aluminium conductor cable of 1.1 KV grade as required. As per CPWD Specification.
a) 3.5C X 300 sq. mm Al arm cable 14.00 Each #NAME? 0.00
b) 3.5C X 240 sq. mm Al arm cable 6.00 Each #NAME? 0.00
c) 3.5C X 120 sq. mm Al arm cable 8.00 Each #NAME? 0.00
d) 3.5C X 70 sq. mm Al arm cable 10.00 Each #NAME? 0.00
e) 3.5C X 25 sq. mm Al arm cable 8.00 Each #NAME? 0.00
f) 4C X 16 sq. mm Al arm cable 6.00 Each #NAME? 0.00
g) 4C X 10 sq. mm Al arm cable 6.00 Each #NAME? 0.00
24 Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE armoured copper conductor cable of 1.1 KV grade as required
a) 4Cx25Sqmm Armoured Copper cable 12.00 Each #NAME? 0.00
b) 4Cx16Sqmm Unarm/Armoured Copper cable 4.00 Each #NAME? 0.00
c) 4Cx10Sqmm Armoured Copper cable 4.00 Each #NAME? 0.00
d) 4Cx6Sqmm Armoured Copper cable 20.00 Each #NAME? 0.00
e) 3C X 2.5 Sqmm Copper Armoured LT Cable End Joint 80.00 Each #NAME? 0.00
25 Supplying and making end termination with Nickel plated brass gland and Copper lugs for 1Cx300 Sqmm Copper Unarmoured cable of PVC/XLPE insulated and PVC sheathed / XLPE unarmoured copper conductor cable of 1.1 KV grade as required. 32.00 Each #NAME? 0.00
26 Wiring for light point / fan point / exhaust fan point/call bell point from nearest switch box with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, fan regulator, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (as per detailed CPWD specifications for Group C wiring). As per CPWD Specification.
a) Wiring to single light point/Fan point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects. 24.00 Pts #NAME? 0.00
b) Wiring to two light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects. 66.00 Pts #NAME? 0.00
c) Wiring to three light point controlled by 1 No 6A, 250V gr. flush modular type SP switch complete in all respects. 13.00 Pts #NAME? 0.00
d) Wiring to exhaust fan point using 6A, 250V gr. flush type modular SP switch housed along with other lighting switches/separate switch box if required and 3pin 6A, 250V gr. modular type socket housed near the exhaust fan complete in all respects. 5.00 Pts #NAME? 0.00
e) Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 6.00 Pts #NAME? 0.00
f) Wiring for twin control light point(for two lights) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 3.00 Pts #NAME? 0.00
g) Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required As per CPWD Specification. 8.00 Each #NAME? 0.00
h) Supplying and fixing following suitable size GI Box with modular plate and cover on front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16A modular socket outlet and 15/16 A modular switch, connections etc., as required. As per CPWD Specification. 72.00 Each #NAME? 0.00
i) Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3sets of 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. As per CPWD Specification. 40.00 Each #NAME? 0.00
27 Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. As per CPWD Specification.
a) 3 x 2.5 sq. mm 1000.00 Mtrs #NAME? 0.00
b) 3 x 4 sq. mm 2100.00 Mtrs #NAME? 0.00
28 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. As per CPWD Specification.
a) 20MM PVC Conduit 300.00 Mtrs #NAME? 0.00
b) 25MM PVC Conduit 1050.00 Mtrs #NAME? 0.00
c) 32MM PVC Conduit 20.00 Mtrs #NAME? 0.00
29 Supply, fabricating and installing of Following size perforated GI cable trays with cover including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling/fixing to the wall/RCC beam/iron structures as per site requirement complete in all respects and as directed by Engineer in charge. (Note:-M.S. angle supports will be measured separately).
a) 100 x 50 x 2mm thick cable tray with 1.6mm thick cover. 140.00 Mtrs #NAME? 0.00
b) 200 x 50 x 2mm thick cable tray with 1.6mm thick cover. 180.00 Mtrs #NAME? 0.00
c) 300 x 50 x 2mm thick cable tray with 1.6mm thick cover. 25.00 Mtrs #NAME? 0.00
d) 450 x 75 x 2mm thick cable tray with 1.6mm thick cover. 100.00 Mtrs #NAME? 0.00
e) 600 x 50 x 2mm thick cable tray with 1.6mm thick cover. 30.00 Mtrs #NAME? 0.00
a) Supply & providing earth stations using 600x600x3.15mm thick copper plate electrode complete at 2.5 mtr. below the ground level with 20mm dia class B G.I pipe for watering, G.I funnel etc. & Cement concrete base of minimum size 750x750x100mm thick shall be provided using 1:2:6 CC after necessary excavation, refilling of soil, consolidating, ramming, leveling of soil etc. and providing cement concrete chamber of inside dimension 300x300x300mm with a wall thickness of 120mm using 1:2:6 CC above the base concrete including providing 50mm thick RCC cover including required salt & charcoal, 2runs of 50x6 mm(300mm) copper strip from plate electrode upto top of the chamber etc. as per technical specification enclosed with the tender documents & as per IS 3043 complete in all respects. 4.00 Sets #NAME? 0.00
Copper Chemical Earthing
b) Supply & providing earth stations using 600x600x3.15mm thick copper plate electrode complete at 2.5 mtr. below the ground level with 20mm dia class B G.I pipe for watering, G.I funnel etc. & Cement concrete base of minimum size 750x750x100mm thick shall be provided using 1:2:6 CC after necessary excavation, refilling of soil, consolidating, ramming, leveling of soil etc. and providing cement concrete chamber of inside dimension 300x300x300mm with a wall thickness of 120mm using 1:2:6 CC above the base concrete including providing 50mm thick RCC cover including required salt, charcoal, 10kg Bentonite powder and 2runs of 50x6 mm(300mm) copper strip from plate electrode upto top of the chamber etc. as per technical specification enclosed with the tender documents & as per IS 3043 complete in all respects. 4.00 Sets #NAME? 0.00
c) Supply & providing GI earth stations using 600 x 600x 6.3 mm thick G.I plate electrode at 2.5 mtr below the ground level with 20mm dia class B G.I pipe for watering, G.I funnel etc. & Cement concrete base of minimum size 750x750x100mm thick shall be provided using 1:2:6 CC after necessary excavation, refilling of soil, consolidating, ramming, leveling of soil etc. and providing cement concrete chamber of inside dimension 300x300x300mm with a wall thickness of 120mm using 1:2:6 CC above the base concrete including providing 50mm thick RCC cover including required salt & charcoal, 2 runs of 50x6 mm G.I strip from plate electrode upto top of the chamber etc. as per technical specification enclosed with the tender & as per IS 3043 complete in all respects. 10.00 Sets #NAME? 0.00
d) Supply, fixing & connecting the 50X6mm size G.I strip on wall / clamping to the existing duct wall / fixing on steel structures/ laying 2 ft. below the ground level with necessary excavation, concrete cutting & re-concreting, refilling, consolidation & levelling of soil after laying for interconnection between the earth pits and the LT & HT panels earthing & Transformer body earthing as directed by Engineer-in-charge. Note:- Excavation, concrete cutting & re concreting will be measured separately. 230.00 Mtrs #NAME? 0.00
e) Supply, fixing & connecting the 40X6mm size Copper strip on wall / clamping to the existing duct wall / laying in cable tray/ laying 2 ft. below the ground. level with necessary excavation, concretecutting & re-concreting, refilling, consolidation & levelling of soil after laying for interconnection between the earth pits and transformer neutral as directed by Engineer-in charge. Note:- Excavation, concrete cutting & re-concreting will be measured separately. 200.00 Mtrs #NAME? 0.00
f) Supplying & laying 25 mm X 5 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm) 250.00 Mtrs #NAME? 0.00
g) Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm). As per CPWD Specification. 50.00 Mtrs #NAME? 0.00
h) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. As per CPWD Specification. 100.00 Mtrs #NAME? 0.00
i) Supply & fixing on the top of the building 3 pronged lightning conductor finials fixed on 20 mm dia copper tube 2 mtrs. long with Copper plate base 300x200x5mm thick. Base & fixing arrangements for the down conductors/GI strip complete in all respects and as directed by the Engineer-in-charge. Note: Base to be installed/clamped on porcelian insulators. 3.00 Sets #NAME? 0.00
j) Supply, fixing & connecting the 25x3mm(75 sqmm) size G.I strip on parapet wall / clamping to the existing duct wall / fixing on cable tray/ clamping on wall with suitable size epoxy insulators at a spacing of minimum 0.8mtr (between 2 insulators) including fixing hardware complete in all respects and as directed by the Engineer-in-charge. 400.00 Mtrs #NAME? 0.00
31 Sand & Brick Protection
a) Supplying and providing 75mm thick sand around the LT/HT grade armoured UG cables including providing the well burnt brick covering extreme ends, in between the cables and top of the cables as per standard practice for 4Runs of cable. 120.00 Mtrs #NAME? 0.00
b) Supplying and providing 75mm thick sand around the LT/HT grade armoured UG cables including providing the well burnt brick covering both sides and top of the cable as per standard practice for 1Run of cable. 180.00 Mtrs #NAME? 0.00
32 Supply and laying of 32mm dia size PN8, PE-80 HDPE pipe of approved make confirming to IS 4984:1995 with necessary connecting / welding sockets / couplings / Tees/Bends in the excavated trench/duct/at road crossings for encasing OFC cables complete and as directed by Engineer-in-charge. 400.00 Mtrs #NAME? 0.00
33 Supply and laying of 50mm dia, PE-80, PN6 ISI marked HDPE pipe confirming to IS 4984:19955 including suitable jointing using welding as required in the excavated trench/duct/at road crossings for encasing cables complete in all respect as directed by Engineer-in-charge. 150.00 Mtrs #NAME? 0.00
34 HT cable rerouting
a) Supply & laying 3Cx400Sqmm HT cable(11kV earthed) in the already excavated cable trench/cable tray/fixing on wall/duct wall/HDD HDPE Pipe with necessary M.S clamps / encasing in pipes etc., testing & commissioning of following size XLPE insulated Aluminium (Al) conductor(stranded) 11 KV grade confirming to IS: 7098 ( part-I)/1998 with upto date amendment earthed Armoured (Arm)U.G cables and as per technical specification including stacking at site, proper storage complete etc., as required. (Note:- Excavation, sand & Brick Protection, concrete cutting, reconcreting, casing pipes will be measured separately.) 400.00 Mtrs #NAME? 0.00
b) Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 400sqmm, 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 2.00 Each #NAME? 0.00
c) Carrying out Mechanized Horizontal directional drilling(HDD) of soil under the existing road/gate way for laying 1run of HDPE pipe including supply and laying 1 run of 125 mm dia PE100 PN08 HDPE pipe with ISI mark and conforming to IS 4984:1995 including suitable jointing using welding as required, providing pull tapes in the laid HDPE pipe, ends brought out, the brought out ends shall be sealed with suitable material to prevent soil and water entry and buried under soil. A cement concrete route marker shall be grouted in the soil above both the end of pipes with mark "End of pipes 1Rx125mm"complete as directed by Engineer in charge. 280.00 Mtrs #NAME? 0.00
35 Excavation in all types of soil for Cable trench including refilling, consolidating of soil after laying the cable including ramming and levelling to smooth finish as per the Technical specifications enclosed and as directed by the Engineer-in-charge. 176.00 Cu.Mtrs #NAME? 0.00
36 Concrete cutting/Chipping/Bitumen Road the existing 1:2:4 cement concrete road /pavements / flooring / rock/stone etc., including removing debris from the work site and depositing in the place as directed by EIC. As per CPWD Specification. 10.00 Cu.Mtrs #NAME? 0.00
37 Re-concreting the cut portion/closing the dummy cable duct at same area with 1:2:4 cement concrete by employing 20mm graded aggregate granite to smooth finish including curing and form work if any complete in all respects and as directed. As per CPWD Specification. 8.00 Cu.Mtrs #NAME? 0.00
38 Fabrication, supply, fixing / welding / grouting to the existing wall/cable duct/truss using suitable size MS angles/channel/flats with cross supports, clamps etc. for cable tray & Highbay light fixtures including fixing hardwares & painting with two coats of black paint over a coat of zinc chromite primer complete in all respect and as directed by Engineer in charge. As per CPWD Specification. 1300.00 Kgs #NAME? 0.00
39 Supply and laying of 160mm dia, PE-100, PN8 ISI marked HDPE pipe confirming to IS 4984:1995 including suitable jointing using welding as required in the excavated trench/duct/at road crossings for encasing cables complete in all respect as directed by Engineer-in-charge. 18.00 Mtrs #NAME? 0.00
a) Supplying and drawing single mode 12 Core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db/ km) at Operational Wavelength 1310 nm and ± 0.22. As per CPWD Specification. 500.00 Mtrs #NAME? 0.00
b) Supplying and fixing of 15U Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. As per CPWD Specification. 2.00 Each #NAME? 0.00
c) Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel.24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. As per CPWD Specification. 5.00 Each #NAME? 0.00
d) Supply and fixing 12 port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single /Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required. As per CPWD Specification. 3.00 Each #NAME? 0.00
e) Supply and fixing 24 port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required. As per CPWD Specification. 1.00 Each #NAME? 0.00
f) Supplying, drawing, Installation, Testing and commissioning of 2 runs of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. As per CPWD Specification. 1200.00 Mtrs #NAME? 0.00
g) Supply, Fixing in flush with wall/on Aluminium partition as per site condition, testing & Commissioning of 2 nos of RJ-45 modular type sockets for Data points including supply of suitable size modular MS/PVC surface mounting box with base plates, glossy finish front covers, labelling etc., with necessary interconnections and chipping the wall, replastering to smooth finish etc., wherever required complete as directed by Engineer-in-charge. As per CPWD Specification. Approved Make: COMMSCOPE TYCO/ PANDUIT/ MOLEX/Legrand/ Schneider/ HAL approved makes 43.00 Each #NAME? 0.00
h) Supplying, Installation, Testing and commissioning of 1 mtr length CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. As per CPWD Specification. 43.00 Each #NAME? 0.00
i) Supplying, Installation, Testing and commissioning of 3mtr CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. As per CPWD Specification. 86.00 Each #NAME? 0.00
j) Supply and fixing of Route Markers made up of 35x35x5mm Langle (600mm - 700mm length) with name plate of size(200x300x5mm). 2coats of red oxide and one coat of suitable approved colour painting for angle/ plate/markings. Route marker shall be 300mm below the ground level. Rate shall include necessary excavation and concreting for route marker complete in all respects as directed by Engineer-in-charge. 25.00 Each #NAME? 0.00
k) Supply, shifting & positioning of Cement Chamber of size 2.5'X2.5' with cover Lid as per site requirements complete in all respects as directed by Engineer-in-charge. 4.00 Each #NAME? 0.00
l) Supply and laying of 80mm dia class B GI.Pipe for encasing cable across the road/ drainage crossings and as per standard practice & as directed by Engineer-in-charge. 12.00 Mtrs #NAME? 0.00
m) Supply, fixing and termination of OFC cables in Splicing Enclosure -12 Port (Single/multi Mode as per site requirement) including all accessories to complete jointing of OFC cables in all respects as directed by Engineer-in-charge. Approved Make: COMMSCOPE TYCO/ PANDUIT/ MOLEX 3.00 Each #NAME? 0.00
a) Supply & fixing on wall/grouted to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer & providing 20 pair krone type telephone connector junction box including krone connector with necessary mounting frame housed in suitable size FRP box with hinged lockable cover complete in all respects. 2.00 Each #NAME? 0.00
b) Supply & fixing on wall/grouted to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer & providing 10 pair krone type telephone connector junction box including krone connector with necessary mounting frame housed in suitable size FRP box with hinged lockable cover complete in all respects. 1.00 Each #NAME? 0.00
c) Supply, laying in the already excavated cable trench/existing duct/fixing on wall/cable tray/iron structure using suitable clamps etc./ encasing in pipe, testing and commissioning of 20 pair jelly filled armoured copper conductor of 0.5mm dia polyethylene insulated cover, twisted into pairs, colour coded, pairs laid up, fully filled with petroleum jelly as a moisture barrier, core wrapped with non-hygroscopic polyester tape to contain the jelly, covered with aluminium poly-laminates screen, polyethylene sheath extruded over aluminium screen, polyethylene tape over the above sheath, armoured with galvanised steel tape and outer polyethylene sheath underground telecommunication cable including both end terminations on the existing krone type junction box complete in all respects. 170.00 Mtrs #NAME? 0.00
d) Supply, laying in the already excavated cable trench/existing duct/fixing on wall/cable tray/iron structure using suitable clamps etc./ encasing in pipe, testing and commissioning of 10 pair jelly filled armoured copper conductor of 0.5mm dia polyethylene insulated cover, twisted into pairs, colour coded, pairs laid up, fully filled with petroleum jelly as a moisture barrier, core wrapped with non-hygroscopic polyester tape to contain the jelly, covered with aluminium poly-laminates screen, polyethylene sheath extruded over aluminium screen, polyethylene tape over the above sheath, armoured with galvanised steel tape and outer polyethylene sheath underground telecommunication cable including both end terminations on the existing krone type junction box complete in all respects. 20.00 Mtrs #NAME? 0.00
e) Supply & drawing of 0.5 mm dia copper conductor PVC insulated 4 pair colour coded and twisted unarmoured telecommunication cables in the existing PVC conduit as per standard practice including necessary inter connections & end terminations. As per CPWD Specification. 500.00 Mtrs #NAME? 0.00
f) Supply, Fixing, in flush with wall/on Aluminium partition as per site condition, suitable size modular MS box with base plate, glossy front cover for supply and housing of 1 No. of RJ-11 telephone socket outlets with necessary interconnections, chipping the wall and replastering to smooth finish complete in all respects and as directed by Engineer-in-charge. As per CPWD Specification. 18.00 Each #NAME? 0.00
42 Access Control System
a) Access Control System with 2.8" display (without Face Recognition Readers) Supplying, Installation, Testing and Commissioning of Access control system comprising of fingerprint, card, and password authentication and having following specifications: · Authentication Methods: Fingerprint, Card & Password with Capacitive Touch screen. · Fingerprint Detection: Fake Fingerprint Detection Technology. · Display: 2.8" TFT touch Screen display. · Capacity: 10,000 Fingerprint storage (1:N). · Logs: 200,000 transaction logs. · Power: 12V DC. (UL listed) · Communication Protocols: TCP/IP, WiFi, USB, Wiegand Out / IN, RS 485. · Additional Features: User-wise authentication modes, Built-in Lock Control. · Certifications: CE, FCC, RoHS, BIS. · Environmental: IP 54 Ingress Protection. · Mounting: Suitable for metal surfaces/frames, wooden frames, walls, and flap barriers. As per CPWD Specification. 1.00 Each #NAME? 0.00
b) Software for Web based Access Control System Supplying, Installation, Testing and Commissioning of Web based Access Control Enrolment and Device Configuration Software, Should be independent of OS (Windows), Unified Management of Biometric, Card, and Controllers, Import Functionality for bulk user details, Biometric Template Retrieval for Data Recovery, User Management, Logs and Terminal Management, Support for IP-based and USB Biometric Devices, User-specific Access Policies, Different User Policies on the Same Terminal, Assignment of Specific Access Schedules, Pushing Users to Terminals or Groups, Admin Authority Management to define rights of each user to perform, Blacklist User Management, Access Schedule Creation, Real-Time Log Retrieval, Real- Time User Identification, Secure Storage of Biometric/Users Data, Capable to integrate with 3rd party applications over Web API's, MQTT protocol support. As per CPWD Specification. 1.00 Each #NAME? 0.00
c) Supplying, Installation, Testing and Commissioning of Electromagnetic locks (fail safe type) for following type of Doors suitable for operation on 12 V DC having holding force 600 lbs for Single Leaf Door and 1200lbs for Double leaf door with suitable feedback i/c connection complete etc. as required. As per CPWD Specification. 1.00 Each #NAME? 0.00
d) Supplying, Installation, Testing and Commissioning of Heavy Duty SS Finish Exit Push Button for releasing access doors with all necessary installation accessories i/c connection complete etc. as required. As per CPWD Specification. 1.00 Each #NAME? 0.00
e) Supplying, Installation, Testing and Commissioning of Door Position Sensor i/e connection complete etc. as required. As per CPWD Specification. 1.00 Each #NAME? 0.00
43 Removal of existing services and existing Automobile shop Dismantling/Disconnecting/removal/re-laying/ rerouting/shifting/ re-erection of the following items as-is-basis not withstanding to below details without any damages shifting and handing over the same to the place as shown by Engineer-in-charge/Plant Maintenance department within ARDC/MCSRDC Division (not exceeding 2Km) complete as in all respects as per site conditions and as directed by the engineer-in-charge. Note: 1. The quantity indicated are only approximate. 2. The tenderers are requested to visit the site and acquaint themselves with the present conditon and quote accordingly. 3. No extra claims will be entertained at a later stage. 1.00 LS #NAME? 0.00
4runs of 3.5C x 300Sqmm AL arm LT cable i) Disconnecting, removal on both sides of LT panels (at Sheet metal shop & LS3 Substation of ARDC) including end terminations and existing gland plates for both feeders. New gland plates shall be supplied and fixed for both the feeders.
1run of 3C x 400Sqmm AL arm HT cable i) Disconnecting, removal on both sides of HT panels (at LS main Substation & LS3 Substation of ARDC) including end terminations and existing gland plates for both feeders. New gland plates shall be supplied and fixed for both the feeders.
OFC cable i) Disconnecting, removal of OFC cable, LIU at heat treatment shop of ARDC.
Street light Pole Disconnecting, removal of street light pole(7mtr approx) and street light fixture and handing over to the MCSRDC.
Automobile shop Disconnecting the following items automobile shop and handing over the same to the ARDC plant maintenance dept. 1. LT panel(1.5mtrx1.5mtr approx): 1No 2. Disconnecting and removal of incoming and outgoing cables in the panel. 3. Distribution boards including MCBs: 2Nos 4. Starter board including isolators and starters: 1No 5. Highbay lights: 6Nos 6. Aircirulators(750mmdia): 4nos 7. Tubelight/ceiling fan: 5nos 8. Switch boards: 11nos 9. Associated conduits and wiring for all the above items.
Proposed Automobile shop Shifting of the following dismantled items at proposed location of Automobile shop and installation, testing & commissioning of the same as is basis. 1. LT panel(1.5mtrx1.5mtr approx): 1No 2. Aircirulators(750mmdia): 4nos
Fire alarm System
44 INTELLIGENT FIRE ALARM SYSTEM
a) Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. As per CPWD Specification. 1.00 Each #NAME? 0.00
b) Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. As per CPWD Specification. 66.00 Each #NAME? 0.00
c) Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or separate) complete of suitable range (min 40mtr) with emitter and receiver including connections with remote test features etc complete as required. As per CPWD Specification. 2.00 Each #NAME? 0.00
d) Supply and installation of PVC type response indicators with LED indications for above false ceiling detectors and shall comply to BS-5839/EN54/IS2189 standards for installation and product shall be UL / FM / Vds approved. 32.00 Each #NAME? 0.00
e) Supplying, installation, testing & commissioning of fault isolator complete with base as required. As per CPWD Specification. 7.00 Each #NAME? 0.00
f) Supplying, installation, testing & commissioning of addressable manual call point complete as required. As per CPWD Specification. 7.00 Each #NAME? 0.00
g) Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. As per CPWD Specification. 7.00 Each #NAME? 0.00
h) Supply, installation, integrating with the existing main FACP, testing & Commissioning of Auto dialer with addressable control module connected to main control panel with minimum 10 telephone nos. connectivity working on 24volts supply including connected cabling/wiring complete in all respects, as per technical specification. 1.00 Each #NAME? 0.00
i) Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V(with ISI mark) rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. As per CPWD Specification. 600.00 Mtrs #NAME? 0.00
Sub Total of Part 'II A' - Electrical, Data, Voice & Fire Alarm Works #NAME? 0.00
Part 'II B' - AC Works
1 Design, supply, loading, transportation, unloading, installation,commissioning and testing of factory assembled, microprocessorcontrolled Air-cooled, screw chiller package of minimum capacity of 65 TR at actual condition( ambient temperature is 35 degree celsius) conditions. Each package chiller will comprise of the following:Single / Multiple semi hermetic/hermetic type compressors operating on eco-friendly refrigerant such as R-134a or equivalent eco friendlyrefrigerant complete with controls and accessories,crankcase heaters and relays, automatic modulating capacity control,suction and discharge ports, forced feed lubrication system with oil seperator, acoustic enclosure etc. The unit shall also contain safety devices as prescribed by the OEM. The motor shall be refrigerent cooled in case of semi-hermetic/hermetic type, and shall be ofsquirrel cage type.Air-cooled condensor(s) made of copper tubes mechanicallyexpanded into aluminium fins,statically and dynamically balanced low noise condensor fans and motors.The condensor shall be with relief valve,purge valve,receiver of adequate storage capacity,shut-off valves complete in all respect etc.Shell and tube DX/flooded type chiller with steel shell and copper tube and complete with drain points. Chiller shall be insulated with Nitrile rubber faced with aluminium foil of adequate thickness or as per company standard.Chiller shall be with suitable baffles and adequate tube surface area and complete with cooling and antifreeze thermostats. Antifreezethermostat shall be factory set and sealed at 37 degF or as required for opertaing chiller .Microprocessor based control centre unit in fully enclosed steel cabinet (IP 55 Protection) with power
and safety operating controls in separate compartments and complete with monitoring facilities for suction/Discharge pressure, oil pressure, suction line super heat etc.Power supply panel (IP 55 protection) housing comprising of Factory built MS Supporting framework, suitable spring type vibration isolators shall be provided. Necessary spring type vibration isolators shall be provided for the Units as a whole.Initial first fill charge of refrigerant R134a or equivalent and oil.all main power connection(s), for compressor(s). and condensor(s), factory wiring for compressor(s), condensor(s). The type of starter shall be VFD.Note:1) Detailed specification of chillers have been brought out in the technical specifcation.This specification has to be read in conjunction with technical specification provided in the tender. It is spelled out that, any discrepancies in BOQ / technical specifcation have to be brought out before quoting, later no claims will be entertained in this regard. 2)2no of chillers are working and 1no is standby) The actual tonnage of chiller to be arrived after applying deration factor of brine solution in chiller. The quantity /percantage of brine solution to be added to get the chilled water outlet not more than 2 degree centigrade Note:Inlet water temperature:7 degree celsius Outlet water temperature : 2 degree celsius Ambient temperature: 35 degree celsius 3.00 Sets #NAME? 0.00
2 Supply, Installation, Testing, Commissioning and handing over of Chilled water pumps End suction Top Discharge pumps of min capacity 185 USGPM at 25 Meters , along with Mechanical seal and bronze impellar including all necessary accessories etc., complete in all respect including necessary rubber bellows at inlet and out let connection of piping for water circulation pumping. (2W+1S).The noise level shall be limited to 65 dBA at a distance of 1.8 m. The unit shall be factory mounted on a common base frame and suitable for outdoor application. The quoted price shall also include cost of thermal insulation, cladding as per site condition and Spring vibration isolator etc complete in all respect . 3.00 Sets #NAME? 0.00
3 Design, supply, loading, transportation, unloading, installation, commissioning and testing of20000 CFM capacities (50 ton COOLING COIL LOAD) INDOOR type AHU made of minimum 45 mm thick PUF insulated double skinned panel of density 40kg/cu.m(±2kgs)of sectionalised sheet steel construction with Outer sheet of panels shall be made of pre-plasticised/ powder coated GSS sheet of 0.6 mm thick and inner sheet of 0.6 mm plain GI. The entire unit shall be fitted with double skin panels. AHU is complete with filter section, minimum 6 row deep chilled water coil of copper tube & aluminium fins construction, direct driven SISW backward plug fan, filters, coil size shall be selected for a maximum face velocity of 500 feet/minute, required face area of the coils to meet humidity level and external static pressure as 70 mm wc or higher as requird at site . Motor shall be with TEFC Squirrel Cage IP 55 Protected VFD Compatible induction motor minimum IE - 2 class efficiency suitable for 415 +/- 10% volts, 50 cycles, 3 phase power supply. The AHU comprisies of plenum to accomodate Fine filters from 99% down to 3.0 microns and Pre filter from 90% down to 10.0 microns.The AHU's shall also contain Magnehelic gauges with necessary interconnection.Scope of work includes SITC of these filters, 1 set of pre-commissioning filters to be supplied for each AHU complete in all respect and as directed by OIC/EIC.(Note: Number of cooling coils indicated for each AHU is indicative. Incase more number of coils are required, same to be provided wihtout any extra claims.) 2.00 Sets #NAME? 0.00
4 CSU (CEILING SUSPENEDED UNIT): Design, Supply, loading, transportation, unloading, installation, commissioning and testing of ceiling suspended minimum 3200 CFM (with suitable cooling coil load) capacities Air Handling Unit (AHU) made of 40 mm thick (±2mm), 40kg/cu.m(±2kgs)density PUF insulated double skinned air handling unit of sectionalised sheet steel construction with outer sheet of panels shall be made of pre-plasticised GI sheet of 0.6 mm thick and inner sheet of 0.6 mm plain 304 grade stainless steel sheet. The entire unit shall be fitted with double skin panels with frame work of thermal-break profile complete. AHU is complete with filter section,minimum 4 rows deep chilled water cooper cooiling coils (Number of rows of cooling coil shall be as per OEM design to meet the specification).Fan section with plug fan mounted on spring vibration isolators, Fan-motor assembly (as a whole) shall be statically & dynamically balanced, double hinged type/suitable type access doors for both motor and filters as per site requirement, cabin light fixure with door interlocking limit switch, Drain pan made out of SS 304 18G stainless steel duly insulated, including pressure testing of refrigerant piping complete. The coil size shall be selected for a maximum face velocity of 500 feet/minute and minimum 50mm WC external static pressure or as required to overcome pressure drop in the systems. Motor shall be with TEFC Squirrel Cage IP 55 Protected VFD Compatible induction motor minimum IE -2 class efficiency suitable for 415 +/- 10% volts, 50 cycles, 3 phase power supply. The AHU shall be supplied with filter section to accomodate Fine filters from 99% down to 3.0 microns and Pre filter from 90% down to 10.0 microns. The AHU's shall
also contain Magnehelic gauges with necessary interconnection and required Temperature sensors.AHU noise level shall be as per OEM standard (Scope of work include SITC of pre and fine filters).Corded remote controller for operating CSU is also in scope of work. 3.00 Sets #NAME? 0.00
5 Supply installation testing and commissioning of Sequence control panel for automatic controling, sequencing the AHUs, Chillers, Water Pumps etc including all control logic, copper wiring, termination of control copper wiring laying in the MS conduit including all accessories and fixing arrangement complete in all respect as per technical specification and as directed by Engineer in charge etc. 1.00 Set #NAME? 0.00
6 Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fitting but excluding valves, strainers, gauges ect.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/ or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specification and as required complete in all respect with aluminium claddingof 26G. Note: The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS:1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350mm dia. and from minimum 7mm thick MS sheet for pipes of 400 dia. and from minimum 7mm thick MS sheet for pipes of 400mm dia and above. As per CPWD Specification.
a 125 mm dia. (32 mm thick insulation) 60.00 RMtrs #NAME? 0.00
b 100mm dia. (32 mm thick insulation) 40.00 RMtrs #NAME? 0.00
c 80mm dia. (32 mm thick insulation) 100.00 RMtrs #NAME? 0.00
d 50mm dia. (32 mm thick insulation) 35.00 RMtrs #NAME? 0.00
e 40mm dia. (32 mm thick insulation) 20.00 RMtrs #NAME? 0.00
7 Supplying, fixing, testing and commissioning of BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot water circulation as specified.The valve should be dul insulated and cladded with 26 guage aluminium sheet. As per CPWD Specification.
a 125 mm dia 5.00 Nos #NAME? 0.00
b 100 mm dia 4.00 Nos #NAME? 0.00
c 80 mm dia 20.00 Nos #NAME? 0.00
d 50 mm dia 6.00 Nos #NAME? 0.00
e 40 mm dia 12.00 Nos #NAME? 0.00
8 Supply,installation,testing and commissioning of 80 mm dia motorised shutoff valves(PN-16) complete in all respect.It SHOULD GIVE SIGNAL Tto chiiler to switch off when not in use
a) 80 mm dia motorised shutoff valves complete in all respect. 3.00 Nos #NAME? 0.00
9 Supply, installation, testing and commissioning of NON - RETURN VALVE with duel plate of C I body SSplates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. As per CPWD Specification.
a) 80 mm dia NON - RETURN VALVE 3.00 Nos #NAME? 0.00
10 Supply, installation, testing of Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. As per CPWD Specification.
a) 40 mm dia 3.00 Sets #NAME? 0.00
b) 80 mm dia 5.00 Sets #NAME? 0.00
11 Supply , installation testing and commissioning of BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I boby flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled/ hot water circulation as specified. As per CPWD Specification.
a) 40 mm dia 3.00 Each #NAME? 0.00
b) 80 mm dia 5.00 Each #NAME? 0.00
12 Supply, installation , testing and commisisoining of 80 mm dia Rubber Bellows 6.00 Nos #NAME? 0.00
13 Supply , installation , testing and commisisoining of 3 way mixing valve with actuator, thermostat and other required aceessories
a) 3 way mixing valve of 40 mm dia for ceiling suspeneded unit 3.00 Nos #NAME? 0.00
b) 80 mm dia 3 way mixing valves for AHU 2.00 Nos #NAME? 0.00
14 Supply, fixing, testing of 100mm dia, dial size Pressure gauges with syphon & cock and isolation valve etc complete. 22.00 Nos #NAME? 0.00
15 Supply, fixing, testing of 100mm dia, Dial type Temperature guage with syphon & cock and isolation valve etc complete. 22.00 Nos #NAME? 0.00
16 Supply, fixing, testing of auto air vents 13.00 Nos #NAME? 0.00
17 Supply,Installation,Testing of suitable dead threaded plug 16.00 Nos #NAME? 0.00
18 Supply, fixing , testing & commissioning of Water flow switch with stem type sensing element probe for flow sensing(NOTE 3 FOR 65 TR CHILLERS ) 3.00 Nos #NAME? 0.00
19 Supply, fixing, testing and commissioning of 32mm dia GI condensate drain pipe with GI Class B with 9 mm thick Nitrile Rubber with 26 Gauge aluminum sheet sealed with adhesive and Tape as per detailed specification for the following sizes 60.00 RMT #NAME? 0.00
20 Supply, installation & commissioning of Closed expansion tank of 1000L capacity with AIR SEPARATOR made of mild steel and has a synthetic rubber membrane. Nitrogen gas or compressed air is filled in space between the membrane and the wall of the tank. The tank should be supplied complete with pump of 2 nos (1W+1S), isolating valve, check valve, strainer, necessary wiring , drain valve & pressure gauge along with Air-separator. Before connecting the tank to water system, the gas pressure should be checked through the charging valve and adjusted according to the requirements. It shall be suitable for outdoor installation and pump motor IP-55,mounted on existing duly painted MS frame work for installation the expansion tank. Complete in all respect and as directed by engineer in charge. Make:-Grundfos, Anergy. 1.00 SET #NAME? 0.00
21 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet connection system and overflow pipes,making it operation with final flow check to toilets. note: Rate to be quoted for 1 no of tank capacity of 1000 litres. As per CPWD Specification. 1.00 nos #NAME? 0.00
22 DUCTING : Design, supply, installation & testing and commissioning of factory fabricated or at site fabricated GSS ducting as per IS 655 with zinc coating of minimum class VIII i,e. 120GSM total on both sides as per IS 277, zincchromate painted angle iron flanges/Transverse duct, bolts and nuts,gaskets, stiffeners, canvas connections, fixing of anchor grip boltsconnectors etc., supported on suspenders of Mild steel (MS) rods / MSwall brackets, cradles, angle iron supports, (All duct supports shall be measured separately) including chipping and plastering of opening madein wall/wall GI sheet with suitable sealant for crossing the duct and for duct supports complete as per specifications and as directed byEngineer-in-charge. Note: Duct for outside air intakes shall be complete with bird screen,damper,collar, rough filters etc., for which no seprate payment will made.
a) 24 G 180.00 SQM #NAME? 0.00
b) 22 G 640.00 SQM #NAME? 0.00
c) 20 G 80.00 SQM #NAME? 0.00
d) 18 G 100.00 SQM #NAME? 0.00
23 Design, supply, installation, commissioning and testing of CO2 sensor with controller, necessary cables and aceesories.CO2 sensor to be fixed in the room .The fresh air damper(approx 1000mm *500mm) is fixed on the AHU wall with actutor .The actuator on taking signal from CO2 sensor should actuate and control the volume of fresh air from outside.The fresh air damper on wall will be connected to cowl with pre filter .The cowl with pre filter is included in sccope of duct work. 1.00 Set #NAME? 0.00
24 Supply, fabrication, installation and testing the flexible connections constructed of fire resistance flexible double canvas zipped sleeve as per required size complete in all respect for outdoor/ INDOOR type AHU units. 6.00 Sets #NAME? 0.00
25 SUPPLY JET DIFFUSER/RETURN GRILL
a) Supply & installation, testing and balancing of circular jet diffuser of power coated Aluminum to deliver not less than 1000cfm each, suitable dia with jet nozzle section mounted on aluminium square plate covered by flanges mounting on existing supply air duct including suitable volume control damper complete in all respect and as directed by Engineer in Charge. 40.00 Nos #NAME? 0.00
b) Supplying, Fixing, installation, testing andcommissioning of supply air diffusers of powder coated aluminium with aluminium volume controldampers with anti smudge ring & removabl core inconfirmation to SMACNA/IS and as per specifications complete etc. as required. As per CPWD Specification. 6.50 Sq.Mtrs #NAME? 0.00
c) Supplying, Fixing, installation, testing andcommissioning of Return air diffusers of powder coated aluminium without volume control damperswith anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required. As per CPWD Specification. 6.50 Sq.Mtrs #NAME? 0.00
d) Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specifications complete etc. as required. As per CPWD Specification. 20.00 Sq.Mtrs #NAME? 0.00
26 Supplying, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages,flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required. As per CPWD Specification. 8.00 Sq.Mtrs #NAME? 0.00
27 Supply,installation,testing and commissioning 150mm depth fire dampers fabricated out of minimum 16 gauge GI sheet construction and 18 gauge GI blades complete with chrom plated spindle, self lubricating bushes with 90-120Minutes fire rating as per UL 555 with 600mm extended sleeves as applicable with fusible link, complete in all respect 8.00 SQM #NAME? 0.00
28 Ducting Acoustic Insulation: Supply & Installation of Acoustic insulation for existing Supply air ducts with 15 mm thick open cell nitrile rubber with OEM recommended adhesive and density 140 kg / cum having open cell foam structure of Class 1 fire category as per technical specification. 134.00 SQM #NAME? 0.00
29 Supply, Fixing of Acoustic insulation for AHU room on the existing wall using 25 mm thick nitrile rubber open cell insulation with OEM recommended adhesive and density 140kg/cum having open cell foam structure of class 1 fire category provided in the suitable GI frame work as per site requirement. Complete in all respect as directed by Engineer in Charge. 210.00 SQM #NAME? 0.00
30 Supply, installation, testing and commissioning of thermal insulation of Closed cell fire retardant(FR) Cross linked Polyethylene Foam (XLPE) with Aluminium face. The Insulation Material shall be UL CERTIFIED / FM Approved & shall have fire performance such that it passes Class “O” as per BS 476 Part 6 for Fire Propagation and Class "O" as per BS 476 Part 7 for surface spread of flame.
a 13 mm for Supply Ducts 600.00 SQM #NAME? 0.00
b 9 mm for Return Ducts 400.00 SQM #NAME? 0.00
31 Supply and Fixing of Underdeck insulation for AHU room roof using 13mm thick Closed cell chemically cross linked polyethelene foam density of 30 kg/cum insulation material with one side factory laminated aluminium sheet to fix the insulation on the ceiling with additional support of GI frame/strip works for entire insulated area using GI washers and tie wires on perlins including all accesseries and required hardware as per site requirement and as directed by Engineer in charge. Note : Contractor should make sure that there should not be any sag after fixing the insulation. 110.00 SQM #NAME? 0.00
HEATER BANKS AND PAN HUMIDIFIER
32 Supply, installation, testing and commissioning of min 60 kw capacity Stainless steel Pan humidifier kit with control panel to be provided for seasonal operation comprising of immersion heater, float valve assembly, inlet, make up and drain water pipe connections, necessary piping with GI class `B' pipe, LT cabling & earthing etc., and complete as required with controls. The Inlet pipe connections along with valves, accessories to pan humidifier from nearby water point using 20mm dia CPVC pipe of approximate 20mtrs length shall also be part of the scope. 2.00 Sets #NAME? 0.00
33 Supply, installtion, testing & commissioning of Heating kit with control panel comprising of strip heaters, safety thermostat, contactors including cabling and interconnections. The heaters should be arranged in three independently operating banks of 20kw each in the main supply air duct at suitable location and complete as required. Strip heater capacity should cater for all seasional variations and changes in equipment/product load from 0% to 100%. total kw required is 60 kw or higher . Note :the heater set is for 1 no AHU of 20000 cfm 2.00 Sets #NAME? 0.00
34 Supply, installtion, testing & commissioning of Heating kit with control panel comprising of strip heaters, safety thermostat, contactors including cabling and interconnections. The heaters should be arranged in three independently operating banks of 3 kw each in the main supply air duct at suitable location and complete as required. Strip heater capacity should cater for all seasional variations and changes in equipment/product load from 0% to 100%. total kw required is 9 kw or higher as required as per site condition . note the heater set is for proposed CSU of 3200 cfm 3.00 Sets #NAME? 0.00
35 Supply, installation, testing and commissioning of MINIMUM 9 KW capacity Stainless steel Pan humidifier kit with control panel to be provided for seasonal operation comprising of immersion heater, float valve assembly, inlet, make up and drain water pipe connections, necessary piping with GI class `B' pipe, LT cabling & earthing etc., and complete as required with controls. The Inlet pipe connections along with valves, accessories to pan humidifier from nearby water point using 20mm dia CPVC pipe of approximate 20mtrs length shall also be part of the scope. 3.00 Sets #NAME? 0.00
ALLIED CIVIL WORKS
36 Supply and laying of Brick work with common burnt clay bricks of class designation 7.5 in superstructure above plinth level in all shapes and sizes, including hoisting and setting in position with cement mortar 1:6 (1 cement : 6 coarse sand) and along with necessary finishing, making or leaving holes & chases and making good etc., and also including necessary openings for fire damper/ duct, etc., all complete as directed by the Engineer-in-Charge. As per CPWD Specification. 1.50 Cu.Mtrs #NAME? 0.00
37 Providing, applying and laying cement mortar (1:6) plastering 15 mm thick on brick/solid blocks/concrete surfaces, finished even and smooth with trowel for Internal/External walls etc., including supply and fixing of hexagonal chicken mesh minimum 150 mm wide having opening 20 mm x 20 mm of 26 gauge at juncitons of concrete & brick work or between different material, including making grooves as per the requirement n.exc 10mm width and n.exc 10mm deep with necesary materials, along with the labour, scaffolding, curing, tools and tackles etc., at all heights, all complete as directed by the Engineer-in-Charge. As per CPWD Specification. 7.00 Sq.Mtrs #NAME? 0.00
38 Suppply and Painting newly & Old plastered interior surfaces with two coats of premium acrylic emulsion paint of interior grade having VOC (Volatile Organic Compound) content less than 50 grams/ litre conformingto IS 15489, of approved make, brand, colour(matching the existing colour, shade & tint), manufacture & pattern at all levels, including preparing the surface by removing loose dirt and any organic growth, smoothening the surface by using suitable emery paper, filling crevices and finishing even and smooth by providing and applying white cement based putty of average thickness of 1mm in 2 coats of approved brand and manufacture over the plastered wall surface and followed by the applying priming coat with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content With water thinnable cement primer on applied putty having VOC content less than 50 grams/litre, necessary scaffolding etc., all complete as directed by the Engineer-in-Charge. As per CPWD Specification. 70.00 Sq.Mtrs #NAME? 0.00
FILTER/FLEXIBLE DUCT/DAMPER/ MIXING BOX/ AHU CONDENSATE PUMP
39 Supply, Installation, Testing & Commissioning of Back draft damper (BDD). The Back draft damper with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1mm thick aluminum and with necessary flanges for connection and as per specifications. (Used in AHU Supply air Mouth).TO BE USED FOR 2 AHUS OF 20000 CFM FOR SIMULATOR DOME AREA 3.30 Sq.Mtrs #NAME? 0.00
40 Supplying, Fixing, installation, testing andcommissioning of thermal insulated flexible duct of 200mm dia duly supported at regular interval as per site requirement etc. in confirmation to SMACNA/IS and as per specifications complete etc.as required. As per CPWD Specification. 22.00 RMtrs #NAME? 0.00
41 Supply and fixing of size 200 dia or as per site condition Round butterfly dampers of GI construction at the takeoffs for the supply air ducts with indication of open & close positions. Complete and as per standard practice. 18.00 Nos #NAME? 0.00
42 Supply, installation & testing of spill air mixing boxes made out of GSS(Min. 120 GSM) sheet of size 500x500x300 mm to be mounted on the supply diffuser and connect to 200 mm dia flexible duct inlet with suitable cutouts and insulated with 13 mm Nitrile Rubber insulation. 18.00 Nos #NAME? 0.00
43 Supply , installation and testing of 1 HP pump with rotational moulded polyethelyne 50 liters minImum capacity water storage tank for collecting condensate water from AHUs and CSUs.Cost also includes min 100 litre polyethylene water tank which is to be placed suitably at ground floor .The condensate drain pipe from2 AHUs and 3 CSUs should connect to 50 lites capcity tank or higher as per site condition as indicated in the schematic drawing . The 50 litres tank hall have float switch/sensor which should give signal to pump to start once water is at certain level and stop once the water has been emptied from the 50 litres tank .The schematic drawing to be refered.The cost of cpvc pipe with insulation will be measured separately. 1.00 Set #NAME? 0.00
44 Supplying, Installation, Testing and Commissioning of following minimum capacity 4-way compact VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter,fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation,Corded remote control etc., suitable for operation on single phase 230V ± 10%, 50Hz AC supply, complete, as required. The Indoor units mustshut down upon receiving a singal from the BMS System/Fire Singnals.The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 °C DB and 19 °C WB temperature. (Make will be same as of Outdoor). As per CPWD Specification.
a 1.6 TR 3.00 Each #NAME? 0.00
45 Supplying, Installation, Testing and Commissioning of following minimum capacity Double way VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation,Corded remote control etc., suitable for operation on single phase 230V ± 10%, 50Hz AC supply, complete, as required. The Indoor units mustshut down upon receiving a singal from the BMS System/Fire Singnals.The cooling capacity of indoor unit will be at air inlet conditions of 27 °CDB and 19 °C WB temperature. (Make will be same as of Outdoor. As per CPWD Specification.
a 2.0 TR 6.00 Each #NAME? 0.00
b 3.3 TR 8.00 Each #NAME? 0.00
46 Supply , installation , testing and commissioining of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100%Hermetically sealed inverter type twin Rotary/Scroll Compressor(s),, microprocessor based Controller, top discharge type condensing Unit, with R-410-A Refrigerant or equivalent, vibration Isolators with Suitable foundation etc. complete as required. To have better efficiency Condenser fan shall be capable to operate at different speed with respect to Load. The unit shall deliver the rated capacity and in confirmation as per IS18728:2024 and CPWD Specifications and work even at 50°C ambientTemperature without tripping. The system shall be able to deliver 100% ofThe rated capacity up to 39 Degree Celsius. The unit shall be suitable to workon 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use asrequired. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overallperformance and durability. The Indian Seasonal Energy Efficiency Ratio(ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWDspecification, connections, inter connections etc. as required.For capacity<40 kwr ISEER 7.4, Capacity > 40 and <70 ISEER 7.5, Capacity > 70 ISEER 7.6 for super ECSBC Building). As per CPWD Specification.
a 20 HP 2.00 Sets #NAME? 0.00
b 16HP 1.00 Set #NAME? 0.00
47 Design, Supply, installation, testing and commissioning of suitable size hard/soft refrigerant copper pipe as required with required pipe fittings , accesories, filter drier and couplings by good quality pipe joints which laid between ODU and IDU The Minimum copper pipe gauge shall be as per the gauges indicated by manufacturer. The Pipe sizes to be used as per OEM design recommendation. The Refrigerant pipe shall be insulated with Class O nitirle rubber of 19 mm thick for Gas line and 19 mm thick for liquid line. The piping shall be laid on walls / roof / ceiling well supported at specific intervals with metallic support, Cable tray with cover and required hardwares etc., for fixing copper pipes. All the necessary accessories, jointing / brazing etc shall be carried out as required. The pressure testing of refrigerant piping has to be done as per manufacturer design recommendation. All the copper fittings shall be suitable for R 410 A/R 407R 134a//R-32 refrigerant. Make: Mandev/Piyush/Totaline (Note: 1. Irrespective of diameter both gas and liquid piping shall be measured as a single item. The single item measurement comprising of gas line, liquid line, insulation and its accessories. Contractor make a note of it and quote accordingly. 2. Before commencement of work, shop drawing to be submitted to OIC/EIC for approval. ) 165.00 RMtrs #NAME? 0.00
48 Design,supply,Installation testing & commissioning of suitable sizes as per OEM recommonadation not less than 2mm thick CPVC drain water / fresh air arrangement pipe including U-traps, vlaves for AHU drain,reducer, bends, collars & elbow etc, all complete and duly insulated with 9 mm thick tubular insulation of closed cell elastomeric nitrile rubber as required.The PVC drain water pipe/fresh air pipe shall be complete with fittings, accessories and duly insulated using bends, elbows, tees, wall sleeves, hangers, supports, anchors etc.(Note:.1 Pipe used for fresh air intake to IDU shalll be coverd with mesh as per site conditioin. 2. Necessary wall openings and closing the same using cement mortar and matching paint finish after taking out pipes is included in the scope of work. ) Make: Supreme/Finolex/Hycount/Saroplast 200.00 RMtrs #NAME? 0.00
Sub Total of Part 'II B' - AC Works #NAME? 0.00
Part 'II C' - EOT Crane Works
1 Design, Manufacturing, transport, Erection, Testing and Commissioning of 3 Ton capacity box type double girder, E.O.T crane with a span of 17.5 mtrs (approx), lift height of 12.5 mtrs, complete in all respect and comprising of Crab hoist, electrical controls, cabling as per standard practice and other required accessories. 1.00 Set #NAME? 0.00
2 Supply, Fixing, Testing and Commissioning of shrouded bus bar 125A- 4 row GI DSL system with all required accessories complete in all respects and as per the technical specifications Annexure-I and as directed OIC/EIC. 35.00 RMtrs #NAME? 0.00
3 Supply, Erection and commissioning of 50 MM bright Square bar for above crane with all necessary accessories complete in all respect on both sides of bay length and as per the technical specifications Annexure-I and as directed OIC/EIC. 70.00 RMtrs #NAME? 0.00
Sub Total of Part 'II C' - EOT Crane Works #NAME? 0.00
Sub Total of Part 'II A' + 'II B' + 'II C' - Electrical Works #NAME? 0.00
Total of Part 'A' - Civil Works + 'II A' + 'II B' + 'II C' - Electrical Works #NAME? 0.00
Add 18% GST #NAME? 0.00
Grand Total (Including GST) #NAME? 0.00
HINDUSTAN AERONAUTICS LIMITED
Facilities Management Division
Pre-Qulification Profile (To Be uploaded along with Part A)
Tender Ref No. or Contract No.: HAL/FMD/C-01/26-27
Name of Work: Proposed Construction of LCH Full Motion Simulator Building for MCSRDC Division, HAL [DC].
Estimated Amount in Lakhs.: 1344.7
Tender Notice Date:(DD/MM/YYYY) 18.04.2026 Can we give in DD/MM/YYYY
Completion Period(In months) 14
PROVISIONAL GST ID NO. for HAL 29AAACH3641R1Z3 Kindly mention at Col I J &K as " Any Other related Information"
Sl.No Description Details Enclosed / Not Enclosed Any Other Related Information Remarks
1 Name of the Individual / Firm / Company: * Mandatory Pls enter name
2 Type of ownership Related Document to be Uploaded to eProcurement Portal
3 Year of Estblishment of Company/Business
4 If Other, please specify
5 Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, etc., If not enclosed reasons be to recorded here
6 Address for correspondence:
8 PAN no and Name of Holder
9 PF number (If any)
11 (a) Service Tax Registration No
11 (b) Goods and Service Tax ID No.
12 Contact details
Contact person name Pls
Ph. No. with STD code
FAX No. with STD code 5 6
13 Registered Contractor
If Registered Contractor with HAL Yes/ No Pls Enter Related Document to be Uploaded to eProcurement Portal * Category: A = Above 25 Crores B = 15Crore to 25 Crores C = 5Crore to 15 Crores D = 1 Crore to 5 Crores E = Lessthan 100 Lakhs to 75 Lakhs F = 75 Lakhs to 50 Lakhs 0 7 .A1 1
Name of Organisation 199999 7 A 2
Category and Registration No. 200000 6 B 3
PEMD Amount ( If paid ) 499999 6 C 4
not required Need to Fill Column 19 no comparision 500000 5 D 5
14 I.T Returns for past 03 years 999999 5 E 6
2025-26 Pls Select 'Yes','No' for IT Returns for all the 3 years 2499999 4
15 Maximum value of works excuted during the followinf 5 years. . (In Lakhs)
2020 - 2021 Pls enter Finiancial Turnover in Rupees for all the years NOTE: The value of max work to be supported with the details of Works executed for each year including name of the organisation with period of execution. Here last 3 years cells to be considered to Check Annual Turn Over for 30 % value of Estimation given above 1 6.00 7.00 0 0
Avg Annual Turnover criteria is not met
16 DETAIL OF WORK ON HAND UPTO N-Months (N-contract period) [For Bid capacity calculation] NOTE : PROVISION for 10 works are given. If more, a separate similar sheet to be made showing all the works with all details as per this FORMAT and same to Uploaded. However, 9 works details to be provided and balance work value of other works to be added and to be provided in 10th row as OTHER works.
Sl.No(work No) Name of Organization with address Name of the work on hand Amount of Contract Rs (in Lakhs) Period of CONTRACT in months Date of Commencement of work as Work Order in dd/mm/yyyy Probable date of Completion as Agreed Actual progress achieved till date of Tender Notification Rs (in Lakhs) Balance value of work on hand [Col.(3)-Col.(7)] Rs (in Lakhs) Remarks If Any 0.00
8 0.00 Max Turn Over 07-08 8500000
9 0.00 Current Level to be brought by adding 10% for every year 10-11 8500000 X 1.1 X 1.1 X 1.1
10 0.00 Turn Over to considered A 11313500
0.00 Balance Work On Hand 207452000
Bid Capacity 0.00 Bid Capacity Criteria is not Met this shouldf be hidden while uploading
17 Work Schedule for completion of works with in stipulated time [Please enclose action plan / bar chart as to indicate the completion of work, within the scheduled time (contract period)] Bid Capacity (2 X A X N) - B
Related Document to be Uploaded -162198000
18 Quantity of work Excuted during the last three years
Earthwork [in Cum]
Concrete work [in Cum]
Reinforcement steel [in MT]
Any other quantity of items tenderer would like to mention
19 Bank(s) details: [Copy of the cheque leaf to be uploaded]
19a Bank Account No. Related Document to be Uploaded to eProcurement Portal (Note Canceled cheque leaf to be uploaded)
Name of the Bank
Type of Account
19b Bank Statement for past three month
19c Latest Over draft Facilties with Bank enter Name of Bank, Date of Issue and Value of Over Draft
20 Latest Bankers Solvency Certificate from Nationalized/ scheduled Bank issued NOT before 12 months from the date of Tender Notice. SOLVENCY solvency cal
Name of Bank & Branch Pls Related Document to be Uploaded to eProcurement Portal 18.04.2026 1-Jul 0 40000
Date of Issue(dd-mm-yyyy) #VALUE! 200000 40000
Value Rs. In Lakhs 200001 150000
Solvency value is as per NIT
21 Experience of having successfully completed similar works during last 7 years ending on the previous day of submission of tender. [Work experience certificates / Completion certificates should be uploaded for verification]. [Latest work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of the estimated cost. [Amount put to the Tender] 40000 500001 250000
Completed similar works during last 7 years You are Not Eligible Pls Select Works Completed during last 7 years 1000000 250000
Work NoI Type of Work [ Incase of private works the same shall be supported with TDS certificate] Related Document to be Uploaded to eProcurement Portal 1000001 500000
Name of The organisation
Brief Description of Work: 2000000 500000
Completed value of Work in Rs. Lakh: 2000001 1000000
Date of Commencement of Work [DD/MM/YYYY]: 4000000 1000000
Date of Actual Completion of Work[DD/MM/YYYY]: 4000001 2000000
Work No II Type of Work [ Incase of private works the same shall be supported with TDS certificate] Related Document to be Uploaded to eProcurement Portal 10000000 2000000
Name of The organisation
Brief Description of Work
Completed value of Work in Rs. Lakh:
Date of Commencement of Work [DD/MM/YYYY]:
Date of Actual Completion of Work[DD/MM/YYYY]: work done
Work No III Type of Work and Organisation name [ Incase of private works the same shall be supported with TDS certificate] Related Document to be Uploaded to eProcurement Portal 18.04.2026 2555
Name of The organisation
Brief Description of Work: #VALUE!
Completed value of Work in Rs. Lakh:
Date of Commencement of Work [DD/MM/YYYY]:
Date of Actual Completion of Work[DD/MM/YYYY]:
Work Competion is NOT with in 7 years
Valid Class I Electrical Licence [or] Undertaking for engaging Electrical Contractor possessing valid Class I Electrical Licence Please Enter Electricial Licence No Electricial Licence valid upto Related Document to be Uploaded to eProcurement Portal
22 DEAILS OF TECHNICAL PERSONNEL AVAILABLE( if space provided is insufficant separate sheet to be uploaded with the same format as below)
Sl.No Name of members or technical personllel avalable in the organization Qualification of similar nature number of years of experience
23 DETAILS OF MACHINERY AVAILABLE
Sl.No Name of Mechinery No Make Year of Manufacture
1 Concrete Mixers - Type etc
2 Vibrators - Diesel - Electrical
3 Weiding equipment's
4 a) Rectifiers
5 b) Welding Generators
6 Erection equipment's
10 Water Lifting motor pumps
13 Drilling Equipment's
16 Stone crushers
17 Bitumen hot mixture plant
18 Bitume boiler
20 Batching plants
21 Vibratory rollers
23 Cranes-Details
24 Concrete pumps
26 Rock breakers
27 Transit mixers
29 Weight batches
24 Details of person holding the power of Attorney (If different from contact person)
Name Related Document to be Uploaded to eProcurement Portal
Ph. No. with STD code
FAX No. with STD code
I/We declare and confirm that - 1. All information and attachments submitted in this application are true and correct. 2. I/We are aware that any false information provided herein will result in the rejection of my application and suspension of any registrations granted. 3. I/We shall not make refund claims of expenditure incurred in processing this application. Pls enter
26 Tender Document Cost and EMD details
Descipttion Enclosed / Not enclosed Valid upto [in case of BG] Related Document to be Uploaded to eProcurement Portal
Tender cost Enclosed
27 Average annual financial turn over during the last 3 years, ending 31st March 2025 [ should not be less than 30% of amount put to tender] and details for last 5 years to be provided to assess the bid capacity. The values provided to be supported by uploading Balance Sheet along with Profit & loss account statement. . (In Lakhs)
2024-25 Pls Select 'Yes','No' for Annual financial turn over for all the 3 years
Average 0.00 FALSE
Balance sheet and Profit & loss statement for last 05 years
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
TN01.pdf
TENDER_DOCUMENT • 0.45 MB
01Amendment.pdf
CORRIGENDUM_DOCUMENT • 0.35 MB
ElectricalTenderDrawings.pdf
TENDER_DOCUMENT • 4.25 MB
01ECSForm.pdf
TENDER_DOCUMENT • 0.48 MB
01PB.xlsm
TENDER_DOCUMENT • 0.22 MB
01PQF.pdf
TENDER_DOCUMENT • 0.20 MB
01CHECKLIST.pdf
TENDER_DOCUMENT • 0.19 MB
01PQnew.xlsm
TENDER_DOCUMENT • 0.04 MB
01UNDERTAKING.pdf
TENDER_DOCUMENT • 0.57 MB
01TBF.pdf
TENDER_DOCUMENT • 5.80 MB
01PBF.pdf
TENDER_DOCUMENT • 0.80 MB
MechanicalTenderDrawings.pdf
TENDER_DOCUMENT • 3.01 MB
CivilTenderDrawing.pdf
TENDER_DOCUMENT • 0.62 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .