Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹32.0 L+₹1.1 L (3.62%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹35.0 L+₹4.1 L (13.2%)Rejected-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹38.5 L+₹7.6 L (24.5%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
13 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer(N) Mamun
Garrison Engineer(N) Mamun Pin-145001
REPAIR/ MAINTENANCE OF SECURITY LIGHTS AND OTHER CONNECTED ITEMS FOR CENTRAL AMENITIES UNDER AGE E/M-I OF GE (N) MAMUN
2023_MES_575329_1
GE(N)/M-59/2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer(N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N) Mamun
₹70,000
21 Mar 2023
16 Jan 2023
15 Feb 2023
16 Jan 2023
13 Feb 2023
31 Jan 2023
Amount
Taking down light fitting from pole including shifting to MES store yard for disposal action complete all a specified and directed.
Supply, fixing, connecting and testing LED Street light luminaire in replacement, 45 watts, 230 volts,50 Hz, pressure die-cast, lluminium housing, Polyster powder coated grey after phosphochromate treatment with top opening cover with powder coated metallic grey finish, Ambient temperature 35° C, Operating temperature: -10° C to + 50° C, system lumen not less than 120/watt, colour temperature 5700 ± 300 K , High efficiency polycarbonate UV stablized cover optics, integrated Lens to ensure high efficiency, LED package modules on MCPCB. Operating voltage range: 140 V - 270 V, isolated electronic LED potted driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit Voltage protection, 10 kV surge protection & other safety tests as per IS 15885 Part-2/Sec13 Average life L70B50: 50000 hours , suitable for mounting bracket arm ID 50 mm complete all as specified and directed.
All as mentioned in item No 2 here in above but 60 watts
All as mentioned in item No 2 here in above but 90 watts
S&F LED Flood light, 100 watts, operating voltage 140 V-270 V,Die-cast aluminium housing, operating temperature -10° C to +45° C, Average life L70B50: 50000 hours, Epoxy powder coated die-cast aluminium housing , High efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen efficacy of LED >120 lm/W, PC Lens with toughened glass, independent Potted IP67 electronic LED driver with APFC,lower THD, Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10 kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1, Colour temp (CCT) 5700 K ±300K complete all as specified and directed.
All as mentioned item No 5 but 150 watts complete all as specified and directed.
All as mentioned item No 5 but 200 watts complete all as specified and directed.
Taking out old U/S Gate light/ post top light fitting and shifting to MES store for further disposal action.
Supply, fixing in replacement LED gate light , 40 watts, 230 watt volts AC, outdoor type, IP-65, spun aluminium die cast landscape luminaire with high power LEDs as light source, . Opal Covers clear cover with impact and corrosion resistant, input voltage 150-270 volts, complete with all accessories all as specified and as directed.
All as mentioned item No 09 but 15 watts.
S&F Post top light fitting , Crown shaped, moon finish made up of Polycarbonate, suitable and including 01 x 09 watts LED lamp with B-22 base holder. Mounting pole dia 60 mm OD complete all as specified and directed.
Taking down street light junction box from steel/ PCC pole including shifting to MES store yard for further disposal action all a specified and directed.
S & F in replacement pole mounted junction box made out of CRCA sheet 3.15 mm thick, side hinged door, Powder coated with 7 tank process, outdoor type suitable for fixing on PCC/Steel poles including Aluminium bus bar, 4 wire, 200 Amps, MCB SP, 230 volts,10 Amps, "C" curve -01 No, minimum internal dimension 300 x 200 x 150 mm with printed sign of skull and bones for danger notice all as specified and as directed. Note: MS clamps for fixing box with pole will be measured and paid seperately.
Taking down street light mounting bracket from steel/ PCC pole including shifting to MES store yard for further disposal action all as specified and directed.
Supply and fixing in replacement street light mounting bracket ,fabricated, made out of GI pipe, light grade, 40 mm bore,120 cm long for mounting on PCC/Steel poles incl 02 X MS clamps of 25x5mm size with nut, bolt, washers etc and painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
All as per item 15 but 32 mm bore pipe
Taking down old U/S street light connection wire from pole including shifting to MES store yard for further disposal action .
M&L in replacement PVC insulated, FR PVC round sheathed, stranded Copper flexible conductor industrial cable, 1100 volts grade, confirming to IS 694, 3 core, 1.5 sqmm for connecting light fitting with junction box drawn through pole all as specified.
All as per item 18 but single core, 2.5 sqmm for connecting light fitting with OH line.
Dismantling old unserviceable street light time switch/contactor from timer panel including shifting to MES store yard for further disposal action.
S&F Astronomical Time Switch, 16A, with 1 changeover (1 CO) suitable to fixing in existing street light control timer panel all as specified and directed.
S&F Time switch,16A, with 1 changeover (1 CO) suitable to fixing in existing street light control timer panel all as specified and directed.
S&F in 3 pole power contactor, 32 Amps, type MNX 32, 415 volts AC Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1, 50 HZ all as specified and directed.
Dismantling old unserviceable street light timer panel from pole including shifting to MES store yard for further disposal action.
S&F in replacement street light timer panel with all components, 415 volts AC, 50 Hz, contactor AC 3 rating 32 A , 3 Pole, Astronomical type, Conforms to IS/IEC 60947-4-1, provided with Protection Degree IP 54, In-built Short-Circuit Protection complete all as specified and directed.
All as per item 25 but digital type.
Repair to existing street light timer control panel at site by inspecting serviceability of each component, rectify the faults if any including replacement of unserviceable parts with new one complete all as specified and as directed. Note: Cost of new components shall be measured under relevant item
Supply and fix in repairs traffic signal of size 300 mm dia, red colour, polycarbonate body, UV stabilized , moulded, water clear polycarbonate, water proof, full circle LEDs, 12 watts, 1.5mm glass epoxy sheet LED PCB, input volts 230 volts AC, visibility 300-500 metres, pf 0.9 complete all as specified and directed.
Dismantling old unserviceable concrete pole/Strut any size and shifting n.exceeding 50 meters, setting aside for disposal action all as specified and directed .
Material and labour for Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l2mm x 279mm at bottom, class 10 complete, erected truly in vertical position and painting the poles with alternate layer of 30 cm with two coats of synthetic enamel paint over a coat of primer upto 1.5 mtr above from bottom complete all as specified and directed.
Dismantling old unserviceable steel poles/Strut any size and shifting n.exceeding 50 meters ,setting aside for re-use or for disposal action all as specified and directed.
Material and labour for erection of steel tubular swaged street light single arm pole 9 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, applying two coats of aluminium paint over a coat of primer after preparation of surfaces duly sanded or etched with including writing pole number and 300 mm strip painting in alternate colour with two coats of synthetic enamel paint over a coat of red oxide primer upto 1.5 mtr above from the coping complete all as specified and directed.
All as per item 32 above but steel tubular swaged for street light,11 mtr long.
Dismantling LT panel from site by removing all cable connections, earthing strip/wires, floor/wall mounting supports including making good disturbed surface matching with existing surface/provisions and shifting to MES store for further disposal action complete all as specified and as directed.
Supply, install, testing and commissioning in replacement LT feeder pillar box, outdoor type, floor mounted, made out of CRCA sheet 3.15 mm thick, CPRI approved, weather proof,dust and vermin proof, IP-54, powder coated with 7 tank process, with common elecrolytic, sleeve insulated Aluminium bus-bar of capacity not less than 1.5 times of main switch gear, 3 phase ,4 wire system, 415 volts AC, both sides openable, double door and locking arrangements for each compartment, prewired with Copper cable not less thatn 4.0 sq mm, provided with danger notice plate, panel mounted on angle iron frame fabricated out of 40x40x6mm size with leg 90 cm long, 30 cm embedded and secured in foundation of PCC 1:2:4 type B1 using 20mm graded stone aggregate (600x300x300mm -02 Nos). Size of panel shall suitable to accommodate and comprising the following components :- (a) MCCB 63 Amps, 4 pole,16 KA, 415 volts, 50 Hz with spreaders - 01 No (Incomer) (b) MCB TP 20 Amps, 16KA, 415 volts, 50 Hz - 02 Nos (Outgoing). (c) MCB SP 20 Amps, 16KA, 230 volts, 50 Hz - 02 Nos (Outgoing). Note:(a) MCCBs shall be, CE marked confirming to IEC-60947-2, maximum operational voltage (Ue) 550 volts (AC 50/60 HZ), Insulation voltage (Ui) of 800 Volts and rated Impulse with stand voltage (Uimp) not less than 8000 volts. Ambient temperature of 50 degree centigrade. MCCB operated by a rotary handle with indication the three distinctive positions(ON/OFF/TRIPPED). (b) MCBs shall have bi connect terminals on the bottom terminals for looping with insulated sliding shutters for making it IP-20 protected & with two position DIN rail clamp for easy mounting.
Supply, install, testing and commissioning in replacement LT feeder pillar box, outdoor type, floor mounted, made out of CRCA sheet 3.15 mm thick, CPRI approved,weather proof,dust and vermin proof, IP -54, powder coated with 7 tank process, with common elecrolytic, sleeve insulated Aluminium bus-bar of capacity not less than 1.5 times of main incomer switch gear, 3 phase, 4 wire system,415 volts AC, both sides openable,double door and locking arrangements for each compartment, prewired with Copper cable not less thatn 4.0 sq mm, provided with danger notice plate, panel mounted on angle iron frame fabricated out of 40x40x6mm size with leg 90 cm long, 30 cm embedded and secured in PCC foundation. Size of panel shall suitable to accommodate and comprising the following components :- (a) MCCB 63 Amps, 4 pole,16 KA, 415 volts, 50 Hz with spreaders - 01 No (Incomer), (b) MCB TP 20 Amps, 16KA, 415 volts, 50 Hz - 01 No (Outgoing). (c) MCB SP 20 Amps, 16KA, 230 volts, 50 Hz - 02 Nos (Outgoing). Note:(a) MCCBs shall be, CE marked confirming to IEC-60947-2, maximum operational voltage (Ue) 550 volts (AC 50/60 HZ), Insulation voltage (Ui) of 800 Volts and rated Impulse with stand voltage (Uimp) not less than 8000 volts. Ambient temperature of 50 degree centigrade. MCCB operated by a rotary handle with indication the three distinctive positions(ON/OFF/TRIPPED). (b) MCBs shall have bi connect terminals on the bottom terminals for looping with insulated sliding shutters for making it IP-20 protected & with two position DIN rail clamp for easy mounting.
All as per item 36 but Size of panel shall suitable to accommodate and comprising the following components :- (a) MCCB 100 Amps, 4 pole,16 KA, 415 volts, 50 Hz with spreaders - 01 No (Incomer) (b) Contactor , 4 pole ,40 Amps, 415 volts AC, with auxiliary contact NO NC - 02 Nos (c) Relay for 15 sec-30 sec time delay contactor change over - As required (d) Rotary switch with 3 mode - 03 Nos (e) Time switch astronomical type - 01 No (f) MCB SP 20 Amps, 16KA, 230 volts, 50 Hz - 18 No (Outgoing). Make of MCB: Legrand (DX3)/Schneider (Acti-9)/Siemens (Betagard) (g) MCBs for control wiring - Qty - 08 Nos Note:(a) MCCBs shall be, CE marked confirming to IEC-60947-2, maximum operational voltage (Ue) 550 volts (AC 50/60 HZ), Insulation voltage (Ui) of 800 Volts and rated Impulse with stand voltage (Uimp) not less than 8000 volts. Ambient temperature of 50 degree centigrade. MCCB operated by a rotary handle with indication the three distinctive positions(ON/OFF/TRIPPED). (b) MCBs shall have bi connect terminals on the bottom terminals for looping with insulated sliding shutters for making it IP-20 protected & with two position DIN rail clamp for easy mounting
S&F in replacement MCCB 3 pole 415 volts , fixed type 25 Amps to 100 Amps with breaking capacity 16 KA, thermal release adjustable from 80 to 100% & fixed magnetic release with Ics = 100% Icu, including spreadres after taking out old U/S one all as specified and directed. Note:(a) MCCBs shall be, CE marked confirming to IEC-60947-2, maximum operational voltage (Ue) 550 volts (AC 50/60 HZ), Insulation voltage (Ui) of 800 Volts and rated Impulse with stand voltage (Uimp) not less than 8000 volts. Ambient temperature of 50 degree centigrade. MCCB operated by a rotary handle with indication the three distinctive positions(ON/OFF/TRIPPED). (b) MCBs shall have bi connect terminals on the bottom terminals for looping with insulated sliding shutters for making it IP-20 protected & with two position DIN rail clamp for easy mounting.
All as mentioned in item No 38 here in above but 125 amps
All as mentioned in item No 38 but 4 pole 415 volts fixed type 25-100 Amps
All as mentioned in item No 40 here in above but 125 amps
Material and labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including dismantling and removal complete all as specified and as directed.
Taking out cable LT 1100 volts grade, heavy duty aluminium conductor upto 10-16 Sqmm, any core from trenches, wall pole or pipe for rectification of faults or replacement including seggregating serviceable/un-serviceable cable and stacking aside for reuse or removing to MES store for disposal action.
All as per Srl Item 43 here in above but of size 50 Sqmm
Supply, laying testing and commissioning in replacement cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 10 Sqmm 2.0 core with provision of termination lugs complete all as specified and directed.
All as above mentioned in item No 45 here in above but Size 16 sqmm 4.0 core
All as above mentioned in item No 45 here in above but Size 50 sqmm 3.5 core
M&L for Cable end termination jointing kit, heat shrinkable, 1100 volts grade complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 sq mm, 3.5 core all as specified and directed.
Taking out old unserviceable GI tubing of 25/40/50 mm bore including shifting to MES store for disposal action.
Supply and fixing GI tubing, light grade 25 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed. (clamps for fixing pipe, nuts, bolts washers shall be measured separately )
All as mentioned in item No 50 here in above but 40 mm bore
All as mentioned in item No 50 here in above but 50 mm bore
Taking out old unserviceable MCCB of any type and capacity including shifting to MES store for disposal action.
M&L for Painting on steel tubular pole, 9 meter long after sanded or etched and primed coated with applying two coats of aluminium paint over a coat of primer after preparation of surfaces duly sanded or etched with including writing pole number and 300 mm strip painting in alternate colour with synthetic enamel paint upto 1.5 mtr above from the coping complete all as specified and as directed.
All as per item 54 but for pole 11 meter long.
Excavating in trenches in soft / loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, trenches for laying of cable, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
All as mentioned in item No 56 here in above but n exc 1.5 m wide and exc 1.5 m and n exceeding 3.0 m in depth
Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required and directed.
Material and Labour for PCC 1:4:8 type D-2 using 40 mm graded stone aggregrate for foundation filling as mass concrete including necessary form work complete all as specified.
Material and Labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregrate for coping of poles and foundation of stay complete all as specified.
Supply and laying in repairs Double Wall Corrugated pipe, 75 mm dia, SN 8 for drawing electric cable in trench all as specified and directed
All as per item 62 but 100 mm dia pipe.
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected by 25X4 mm GI strip as earth lead by means of nuts and bolt, thimbles, check nuts, washers of GI or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20 mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x 300 mm dia,15 mm thick plaster in CM 1:4 funnel with wire guage mesh ,CI cover 10mm thick, hinged to CI frame of 320x320mm size made out 5mm thick angle iron. Charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part -1 (2009) and specified including provision of GI strip upto 7.5 metre long protected by 40 mm dia light grade pipe and watering pipe shall be 20 mm bore medium grade ,including all excavation and earth work and connecting the earthing to an earthing test point and to main switch board as specified and testing on completion complete including Taking up old U/S earthing including all accessories complete all as specified and directed.
Deduct Total amount of SCHEDUL 'A' SECTION-II (SCH OF CREDIT) Rs 93854.00 ( to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
KULBHUSHAN AGGARWAL
M/S SHRI RAM BUILDERS
M/s USHA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .