Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC 3 1 4 GOPINATH BAZAR DELHI CANTT 110 010 | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC ACCEPTANCE | |
| 2 | L2₹32.6 L+₹4.7 L (16.8%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹34.3 L+₹6.4 L (23.1%)Rejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹34.4 L+₹6.5 L (23.3%)Rejected-Finance | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹35.5 L+₹7.6 L (27.3%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹40.7 L
EMD Value
₹81,480
Closing Date
4 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL BHUPINDER SINGH CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
AUGUMENTATION OF EXTERNAL ELECTRIC SUPPLY FOR MISSILE TESTING POINTS OF L7 L8 L9 B5 B6 AT INS VAJRAKOSH UNDER GE(SB) KARWAR
2024_MES_645532_1
85743/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOC
9 documents required · 9 mandatory
₹500
GE (SB) KARWAR
₹81,480
Yes
1 Jun 2024
7 Mar 2024
6 Apr 2024
7 Mar 2024
4 Apr 2024
21 Mar 2024
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/taking out cable and getting out in soft/loose soil all as specified and directed.
Returning, filling in soil including spreading leveling, watering and well ramming in layers not exceeding 25cm thick all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Supply and spread dry river sand in trenches for cable cushioning all as specified in clause 19.75 of SSR Part-I. Note:- Punned thickness of sand only will be measured & paid
Supply and laying un-reinforced pre-cast concrete cable cover, class HV, type 1, flat, size 300mm x 180mm x 40mm complete all as specified and directed.
Supply and laying galvanised iron tubing, light grade of size 80 mm dia with all fittings as in cable protection, laid in trenches complete all as specified.
Supply, laying, testing and commissioning XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, earthed electric power cables (Heavy duty) aluminium conductor 11/635 kV Earthed grade suitable earthed system cross sectional area 95 Sqmm, 3 core HT UG Cable laid in trenches/through GI pipe /fixed along with pole complete all as specified and as directed. Note:- a) Excavation and earth work shall be measured and paid seperately under relevant items of schedule b) High voltage test to be conducted at site with suitable voltage after laying of HT cable and reading to be recoreded jointly and test report to be submitted in triplicate,the cost of the same is deemed to be included in unit rate of subject item. (c) The HT cable route indicator as specified by Engr-in- Charge is also included in the rate quoted.
M&L cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed.
M&L cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed.
Supplying installation, testing and commissioning of Indoor Vaccum Circuit breaker Consisting of VCB triple pole 630 amps having rupturing capacity 350 MVA, 13.1 KA for 3 seconds, horizontal isolation and horizontal draw out type 11 KV totally enclosed extensible pattem with automatic drop down and independent spring charging type motor operated closing mechanism including motor suitable for operation on 230 volt single phase 50 cycle AC supply system and manually operating system with 30 volt DC shunt trip coil with Auxiliary switches mechanical ON/OFF indicator with protective relays and conforming to IS: of 1991 and IS 3427 of 1997 complete all as specified with and including following items:- (a) 3 Nos vacuum interrupters of rating 11 KV, 3 phase 50 Hz. 630 Amps having rupturing capacity 350 MVA mounted on common base segregated Epoxy body for higher electrical insulation and to maintain pole discrepancy as per IEC 56 and self aligned type isolating contacts
(b) Self powered microprocessor controlled numeric relay comprising of two over current, one earth fault protection relay with high set for both phase and earth and with fault memory. universal auxiliary supply as per IS-3231, 8686 The setting for over current shall be 50-200% of 5A (in the step of 10%) and for earth fault element from 20-80% of 5A (in the step of 10%) Make ABB/SIEMENS/ L&T/ Crompton/Ashida (c) Current transformer(CT's) one set of three of ratio 50/25/5+5 Amps having 15 VA burden class 1.0, for metering and class 5P10 for protection- 01 Set of 03 Nos (d) Cast resin Potential transformer dry type having minimum 200 VA burden, ratio 11 KV/110V.
(i) RED/GREEN. VCB ON-OFF Indication (ii) AMBER: Trip Indication (iii) WHITE: Trip Circuit Healthy Indication with Push Button (iv) BLUE: VCB Mechanism Spring Charged Indication (j) 11 KV, 350 MVA 800 Amps Three Phase busbars of aluminium with Rear cable termination ie. Provision for terminating 3 core165 sq mm. XLPE Cable. (k)1 No Strip heater-100W (continuously rated) with thermostat control for breaker/CT compartment with manual ON-OFF switch-1 set.. (l) Structural steel frame including PCC foundation and earthwork as per manufacturer specifications. (m)1 No 3 way breaker control switch with positions TRIP-NEUTRAL-CLOSE (n) Manual charging/operating arrangement. (o) Fuses for metering and protection system
(p) (i) Auto trip. (ii) Motor/manual charged spring operating/closing mechanism. (iii) Fault alarm (iv) Manual tripping (q) All wiring necessary for the above including interconnection to trip coil. The wire should be FRLS type in all panels. (r) Test Terminal Block (TTB) to test meters and relays with sealing arrangement.
NOTE:- 1. The HT panel comprising of VCB to be manufactured by OEM 2. Contractor shall produce manufacturer's test certificate for all routine and type test of VCB's 3. Rate quoted is deemed to be inclusive for above provisions and Civil works for foundation as per manual of manufacturer 4.Any spare/item required at site for functional of above VCB shall be done without any extra cost to the department 5.Auxillary supply voltage for thr Relay/Close/Trip coil 30 volt DC. 6.Proposed VCB shall be fixed with existing VCB panel at substation 1 with all necessary extension of busbar chamber in order to use VCB as buscoupler. Rate is inclusive of extension of busbar chamber.
JAI SHREE GOPAL ELECTRICALS
DURGAI ELECTRICALS
SRI GURUPRASAD INFRATECH
ANKIT SHIP REPAIRERS AND SUPPLIERS
Shree Ayyappa Engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .