Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAdmitted-Finance | ₹7.2 L | L1 | Admitted-Finance |
| 2 | L2₹7.2 LAdmitted-Finance 0 DHANA TEJA BARARI DHANA TEJA MATHURA MATHURA UTTAR PRADESH 281005 UDYAM UP 54 0007790 | MATHURA | UTTAR PRADESH | 281005 | ₹7.2 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical DUE TO INVALID DOCUMENTS |
| 4 | Rejected-Technical | - | - | Rejected-Technical DUE TO INVALID DOCUMENTS |
| Sl No | Description | Qty | Unit | K MAA ENTERPRISES L1 | M/s S.K. CONSTRUCTION L2 |
|---|---|---|---|---|---|
| 1.00 | Testing of 33 KV Feeder panel breakers including testing of CTR both the primary injection Works includes cleaning and adjustment of relay contacts & springs checking of closing and tripping protection trip command through CT (By means of primary of breakers on remote/manual and injection) | 30 | JOB | 2,480 ₹74,400 | 2,500 ₹75,000 |
| 2.00 | Testing of 33/11 KV power Transformer panel marshaling box and breakers by primary injection method. Testing of wiring Temperature. Oil Temperature, Oil level indicators, Buchholz relay, Surge Relay for alarm and tripping Testing of relay, works includes cleaning and adjustment of relay contacts and springs and checking of breakers operations for remote/local closing tripping and protection, trip command generated by primary injection. | 30 | JOB | 2,550 ₹76,500 | 2,500 ₹75,000 |
| 3.00 | Testing of 11 KV incoming/outgoing panels including testing of CTR by primary injection, testing of relay works includes cleaning of relay contacts and adjustment of springs Checking operations and tripping of VCB/OCB on remote/manual and protection trip command generated through primary injections. | 145 | JOB | 2,480 ₹3.6 L | 2,500 ₹3.6 L |
| 4.00 | Testing of 33/11 KV 5/10 MVA Power Transformers installed at various Sub-station under EUTD-VRINDAVAN, Lesa Lucknow including following test | 30 | JOB | 7,000 ₹2.1 L | 7,000 ₹2.1 L |
| 4.01a-No load/ratio test | |||||
| 4.02b-Short circuit test | |||||
| 4.03c-Magnetization current Test | |||||
| 4.04d-Magnetic balance Test | |||||
| 4.05e-Insulation test by Megger | |||||
| 4.06f-Buchholz OTI/WTI Circuit Test | |||||
Tender Value
₹7.3 L
EMD Value
₹7,300
Closing Date
7 Apr 2025, 5:00 pmClosed
SE-EUDC-VRINDAVAN, LUCKNOW.
33/11 KV SECTOR-5D, VRINDAVAN COLONY, LUCKNOW.
TESTING OF 33/11 KV BREAKERS AND POWER TRANSFORMERS INSTALLED AT 33/11 KV S/S IN THE AREAR OF VRINDAVAN UNDER JURISDICTION OF EE EUTD-VRINDAVAN LUCKNOW, AGAINST O AND M 2024-25 SCHEME
2025_MVVNL_989281_4
34/EUDC-VRINDAVAN/LESA/2024-25
Open Tender
Electrical Works
365 days
VRINDAVAN
AS PER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹1,180
A/C NO. 1277784945 IFSC CBIN0280140
₹7,300
17 Sept 2025
1 Apr 2025
8 Apr 2025
1 Apr 2025
7 Apr 2025
1 Apr 2025
Amount
Testing of 33 KV Feeder panel breakers including testing of CTR both the primary injection Works includes cleaning and adjustment of relay contacts & springs checking of closing and tripping protection trip command through CT (By means of primary of breakers on remote/manual and injection)
Testing of 33/11 KV power Transformer panel marshaling box and breakers by primary injection method. Testing of wiring Temperature. Oil Temperature, Oil level indicators, Buchholz relay, Surge Relay for alarm and tripping Testing of relay, works includes cleaning and adjustment of relay contacts and springs and checking of breakers operations for remote/local closing tripping and protection, trip command generated by primary injection.
Testing of 11 KV incoming/outgoing panels including testing of CTR by primary injection, testing of relay works includes cleaning of relay contacts and adjustment of springs Checking operations and tripping of VCB/OCB on remote/manual and protection trip command generated through primary injections.
Testing of 33/11 KV 5/10 MVA Power Transformers installed at various Sub-station under EUTD-VRINDAVAN, Lesa Lucknow including following test
a-No load/ratio test
b-Short circuit test
c-Magnetization current Test
d-Magnetic balance Test
e-Insulation test by Megger
f-Buchholz OTI/WTI Circuit Test
g-Neutral to earth & Body to earth resistance
G.S.T. Extra as per rules.
M/s S.K. CONSTRUCTION (BID ID -5107479)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid