Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.3 LAccepted-AOC BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹48.9 L+₹98,412.70 (2.05%)Rejected-Finance VILL PUILLYA PO UNSANI DISTT HOWRAH PIN 711302 | HOWRAH | WEST BENGAL | 711302 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹49.8 L+₹1.8 L (3.81%)Rejected-Finance TIORKHALI MAHESHGANJ NADIA | NADIA | NADIA | WEST BENGAL | 790804 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹49.8 L+₹1.9 L (3.89%)Rejected-Finance PO CHANDL PS BISHNUPUR DIST SOUTH 24 PGS PIN 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹50.4 L+₹2.4 L (5.03%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹45.6 L
EMD Value
₹91,140
Closing Date
7 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
PROVN OF BOUNDARY WALL FROM MES PUMP HOUSE UPTO TURN ON ROAD NEAR COMD LIBRARY AND SPL REPAIR TO BLDG NO. O-6 FG AND SINGLE LIVING ACCN OF BLDG NO. O 9 INCLUDING ELECTRIFICATION WORK AT INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2022_MES_507833_2
8828/E8
Open Tender
Civil Works
Item Rate
180 days
GE(FW) Kolkata
Ref tender documents
6 documents required · 6 mandatory
₹500
GE(FW) Kolkata
₹91,140
21 Mar 2022
22 Feb 2022
8 Mar 2022
22 Feb 2022
7 Mar 2022
28 Feb 2022
60 days
Amount
SCHEDULE 'A' PART-I (B/R WORKS) Dismantling of wall board as in lining, panelling etc, of any gauge or any thickness including cover fillets complete all as specified and directed.
Dismantling of ceiling board incl snap grid frame of any thickness including cover fillets complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting any gauge or any thickness in roof covering including stacking serviceable materials of re-use and removing unserviceable materials complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description in any position not otherwise specially provided for complete all as specified and as directed..
Demolition of brick work or stone boulder masonry built in cement mortar including all quaries, arches pillars etc and removing off the site complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key and scrubbing down with water complete All as specified and as directed.
Dismantling stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc.4.00 Sqm each wooden all as specified and directed.
Dismantling timber scantling 40 sq cm and over in section in any position (framed work) and removing off the site all as specified and directed.
Taking down shutters of any description exc 1.00 sqm but n.exc 2.00 Sqm each and removal from site complete all as specified and directed.
Taking down shutters of any description exc 1.00 sqm but n.exc 2.00 Sqm each and re-fixing in the same opening complete all as specified and directed.
Excavation in trenches n exc 1.50 m wide and n exc 1.50m depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes etc not exc 10 Sqm on plan and not exc. 1.50 Metre in depth and getting out as in soft/loose Soil, complete all as Specified and as directed.
All as per Item No. 14 above, but in road/hardstanding etc and getting out
Removing excavated materials to a distance outside MOD land and disposing off as per municiplaity instructions complete all as specified and as directed.
Returning filling in incl spreading , levelling , watering and well ramming in layers not exc 25 cm as in soft/ loose Soil, complete all as Specified and as directed.
M&L for providing Plain Cement Concrete (1:4:8) type D2 using 40mm graded stone aggregate as in sub base of floor, foundation filling and mass concrete etc complete all as specified and directed.
M&L for Cement Concrete type B-1, (1:2:4) using 20mm graded crushed stone aggregate in copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including use and waste formwork (straight or curved) complete all as specified and as directed.
M&L RCC design mix (M-25 grade) using 20 mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concretecomplete all as specified and directed. (NOTE: MS reinforcement shall be measured and paid seperately)
M&L RCC design mix (M-25 grade) using 20 mm graded stone aggregate) in Columns, pillars, piers, posts and struts complete all as specified and directed. (NOTE: MS reinforcement shall be measured and paid seperately)
M&L RCC design mix (M-25 grade) using 20 mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. (NOTE: MS reinforcement shall be measured and paid seperately)
M&L Brick Work with fly-ash Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
M&L Brick Work with fly-ash Bricks Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed.
M&L for cutting holes in brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required, depth of embedded portion of holdfasts not exc half brick complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of column, raft and raft beams, side and soffit (if any) for foundation and plinth beams etc, vertical or to batter for fair finished surfaces complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves etc for fair finished surfaces complete all as specified and directed.
M&L for formwork to side of pillars, posts, struts, piers, columns for fair finished surfaces complete all as specified and directed.
S&F for 2nd class hardwood, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, moulded or chamfered, put together with glue, pinned at joints complete all as directed.
S&F Factory made 35mm thick with 2nd class hard wood, rail and style factory made plain framed panelled shutter(two panel) with lock, rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail & style as per IS:1003(Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 35mm thick Factory made 2nd class hard wood glazed & skleton shutters, open rebated and prepared to received glass, gauge etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.20(a) complete all as specified and directed.
S&F 30mm thick Factory made 2nd class hard wood glazed & skleton shutters, open rebated and prepared to received glass, gauge etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.20(a) complete all as specified and directed.
S&F 30mm flush shutter, solid core construction, with block board core and both faces covered with decorative face veneers with lipping/frame to match complete all as specified and directed.
S&F, Powder coated (minimum thickness of powder coating 50 micron) three trackwith 1.8 mm thick channel section and shutter frame thickness 1.65mm, without sash bars, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed. Notes: 1) Size of window shall be as per site requirement. 2) Glass and wire cloth shall be measured seperately.
S&F in repair powder coated aluminium window grill of size 100 mm X 100 mm having section width 6 mm and 3 mm thickness, fixed on aluminium section weighing not less than 0.55 kg/sqm including necessary jointing, fitting etc all as per manufacturer's instruction complete all as specified and directed.
S & F PVC solid door frame of size 50 x 47 mm made out of 5 mmthick prelaminated single side PVC sheet reinforced with MS square tube complete all as specified and as directed.
S & F 30 mm thick factory made both side prelaminated solid panel PVC door shutter consisting of frame made out of MS tube of 19 gauge thickness and size of 19mm X 19mm for stiles, top and bottom rails, treated with a coat of metal primer, MS frame covered with heat moulded prelaminated PVC 'C' channel for stiles and both side prelaminated PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; stiles and rails feathered at edges, panelling of both side prelaminated PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement and fixing in frame complete all as specified and directed.
S&F Butt hinges, medium weight, cold rolled mild steel, size 100 mm complete all as specified and directed.
S&F Extruded aluminium alloy handles, fabricated type, anodised, 150 mm complete all as specified and directed.
S&F for Aluminium anodised barrel tower bolts of extruded sections, 150 mm long complete all as specified and directed.
S&F for Aluminium anodised barrel tower bolts of extruded sections, 200 mm long complete all as specified and directed.
S&F 300mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy all as directed complete all as specified and directed.
S&F in repair rubber gasket of 50 x 6mm as approved by accepting officer for fixing to door/window shutter complete all as specified and as directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
. - ditto - all as per item No. 44 here-in-before, but fixed in repair.
S&F Floor door stopper of brass body and tongue, anodised, with hard drawn steel spring, fixed in floor, overal length of cover plate 140 mm complete all as specified and directed.
S&F in repairs Chromium plated 20mm dia chromium plated brass curtain rod with fixing brackets, stops, rollers etc of approved design complete all as specified and directed. (NOTE: Brackets will be measured and paid seperately)
Supply and fixing Brass bracket for curtain rod decorative type fixed as in repair complete all as specified and as directed.
M&L mild steel bands and straps support or stays holdfast and similar articles conforming complete all as specified and directed.
M&L for Mild steel framed works such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for structural steel work Fe 410-W (Gde-E-250) quality-A in roof trusses (framed), trussed, purlins, crane gantries, rials and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed by the Engineer-in-Charge. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M&L TMT Bars 6-8 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M&L for TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups , spacers and binders cut to length , bent to shape required as in reinforcement and binding with MS wire ( annealed ) not less than 0.90 mm dia complete all as specified and directed .
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
-ditto- but using serviceable sheets obtained from dismantling
All as per Item No. 55 above but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof.
Removal of existing water proof treatment of any description from roof surface including cement plaster/screed bed carefully from the surfaces, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debris complete all as specified and as directed.
M&L for brushing cement slurry @ 2.75 Kg/sqm over cleaned roof surface prior to application of concrete complete all as directed by Engineer - in - charge .
M&L for Providing Cement Concrete, type B-0, 1:2:4 (using 12.50 mm graded Stone aggregate), as in roof padding, of thickness as required on site, for making good depression/undulation, roof kerb etc, finished even and fair complete all as directed.
M&L 10 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M & L for cutting Grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 or cement concrete 1:2:4 type-B1 as required complete all as specified and directed.
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying bitumen primer conforming to IS:3384-1968 over the cleaned base @ 0.50 litre per sqm. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyster matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (iv) Applying two coats of bitumen based UV reflective paint with aluminium finish @ 0.10 litre per sqm over APP membrane.
M&L for false ceiling with 'E' board "Classic", reinforced, designer series, board with HPSC of size 600 mm x 600 mm x 4 mm thick fixed on and including aluminium snap grid to support the boards/files with aluminium anodised main 'T' section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides, fixed to ceiling with hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and as directed. (NOTE: Quoted rate shall be deemed to be inclusive of the cost of ceiling board)
Supply and Fixing PVC solid wall lining consisting of 5 mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per manufacturer’s specification and instruction and as directed.
Supply and Fixing 5mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing.
Supply and fixing 4.8 mm thick sheet glass frosted on one side, area in squares exc 0.5 sqm in each pane, fixed to aluminium frame work / snap beading complete all as specified and as directed by the Engineer-in-Charge
M&L Rendering 5mm thick, on concrete surfaces of walls in cement mortar 1:3, finished even and smooth without using extra cement complete all as specified and directed.
M&L Rendering 15mm thick, on fair faces of brick or concrete surfaces of walls in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick built in cement mortar (1:4) in two layers (10mm + 5 mm) on fair faces of brick work or concrete surfaces finished even & smooth (without using extra cement) and 2nd layer mixed with water proofing compound as per mnufacturer's instruction for bldg height upto 4 storey complete all as specified and directed. (NOTE : Water proofing compound shall be measured and paid seperately).
Supply only liquid water proofing compound all as specified and as directed.
M&L for 75mm thick PCC (1:3:6) type 'C-2' (using 40mm graded crushed stone aggregate) as in floor, plinth protection etc, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L Non Skid joint free ceramic coloured tiles 7-8mm thick, area of each tiles exc 0.11 Sqm but n. exc 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 20 mm thick screed bedding in cement mortar 1:6 complete all as specified and directed.
M&L for glazed coloured ceramic tiles in vertical surface 300 X 450 X 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles, laid over and including 10mm thick screed bed in cement mortar 1:3 complete all as specified and directed.
M & L for pre-polished Chequered cement concrete tiles (coloured) of size 30cmx30cmx25mm thick , set , jointed and pointed in neat cement slurry in floor and pointed with white/coloured cement & pigment to match the surface laid over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for granite (of any type) work, 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, urinal partition and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and making moulds on edges laid over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for 18-20 mm thick coloured granite Slab, machine cut, as in vertical surfaces such as skirting, dado, wall cladding etc, fixed over and including 10 mm thick backing layer in cement mortar 1:3, set and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite tiles including rubbing and polishing complete all as specified and directed..
M&L for complete removal of old distempered surfaces of walls and applying 2 mm thick wall putty over plastered surfaces, finishing surfaces even and smoooth and applying two coats of acrylic distemper over a coat of alkali resistant primer as per manufacturer's instructions complete all as specified and directed.
M&L for applying one coat of acrylic distemper to old decorated surfaces of wall including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed.
M&L for applying one coat of acrylic distemper to old decorated surfaces of ceilings including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying 2 mm thick wall putty over plastered surfaces, finishing surfaces even and smoooth and applying two coats of acrylic distemper over a coat of alkali resistant primer as per manufacturer's instructions complete all as specified and directed.
M&L for applying one coat of weather proof exterior emulsion paint to old decorated surfaces of wall including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed by Engineer -in-Charge.
M&L for preparing newly plastered surfaces of wall and applying Two Coats of weather proof exterior emulsion paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and as directed.
Preparing new surface of wood or wood based material of any description and in any position not otherwise described n.exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of wood primer complete all as directed.
M&L for preparation of old painted wooden surface of any description over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&l for preparation of old painted steel surfaces exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, treating ends of posts, back of chowkhats etc, with tar or coal tar black paint, area tarred exc 0.1 sqm but n. exc 0.5 sqm each complete all as specified and directed.
-ditto- but treating small articles such as holdfasts, ends of posts, back of chowkhats, etc, area n exc 0.1 sqm each
SCHEDULE 'A' PART-II (INTERNAL ELECTRIFICATION WORKS) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets, light fitting etc for reuse or removing from site and making good disturbed surface of walls, floors etc.complete all as specified and directed.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
M&L for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping medium duty complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed.
All as per item No. 93 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (surface type point wiring with terminal box).
All as per item No. 93 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (surface type point wiring with terminal box).
All as per item No. 93 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (surface type point wiring with terminal box).
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No. 97 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 97 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 97 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
S&F switch piano flush button AC 230 V Single pole 5/6 Amp one way complete all as specified and directed.
S&F socket outlet 2-in-1, 3 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination, 5 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 6 and 16 Amps flush type universal complete all as specified and directed.
S&F socket outlet 6/16 Amps, 6 in 1, flush type complete all as specified and directed.
S&F switch piano flush button AC 230 V Single pole 15/16 Amp one way complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/bakelite, three terminals complete all as specified and directed.
S&F electronic type stepped speed regulator, 100 watts, AC 230 Volts for ceiling fan, complete all as specified and directed.
S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
-ditto- as per Item No. 109 but of 1 X 9/10 Watt capacity in polycarbonate housing with lumen output not less than 105 lumen per watt
S&F in repairs LED Bulkhead fitting 10 watt, mounted on wall /ceiling connected with insulated unsheathed flexible copper wire of suitable size (length not exceeding 0.5 m) from ceiling rose complete all as specified and directed.
Taking down and re-fixing ceilings fans, any sweep, complete with blades, down rods and accessories with new flexible copper wire including cleaning, greasing & oiling complete all as specified and directed.
Taking down and re-fixing exhaust fans, any sweep, complete with blades, louvers and accessories with new flexible copper wire including cleaning, greasing & oiling complete all as specified and directed.
M&L for sub main wiring with 2 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through and including PVC casing-caping of suitable size, surface type complete all as specified and directed. (NOTE : Three runs of single core 6.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 114 above but with two runs of 4.0 Sqmm cable and one run of 4.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
S&F TPN DB, IP 43 protection, double door (premium quality), 415 volts, 4 way (8+12), with 100 Amps copper bus bar for each phase complete all as specified and directed. (MAKE : L&T, Cat No. DBTPN004DD / LEGRAND, Cat No: 507670 / SCHNEIDER, Cat No. A9HTND04 / ABB, Cat No: E-SHDB M4 / PANASONIC, Cat No: BQS 304H / HAGER, Cat No: VYT04DH)
S&F, Double Door, Sheet Metal Enclosure for DBs (Premium Quality), for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN008DD / LEGRAND, Cat No: 507611 /ABB, Cat No. E-SHC M 8 / SCHNEIDER, Cat No. A9HSND08 / HAGER, Cat No: VYS08D)
S&F MCB (premium quality), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (premium quality), 'C' series, SPN, 40-63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (premium quality), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (Premium Quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
PRABIR TRADERS
SHEIKH ENTERPRISE
UNITED ENGINEERS
MS AP CONSTRUTION AND CO
S.M.CONSTRUCTIONS
B & R CONSTRUCTION
RAJ ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .